Records from 1982 to 1999. Most recent: inspection, 30 April 1999.
Inspection history · 35
30 April 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1126509
21 April 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 789531
14 January 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 194948
14 January 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 762490
7 January 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409811
28 August 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 144870
31 January 1997
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1435871
3 September 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 66610
3 September 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 207598
3 September 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 212154
3 September 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 221678
3 September 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 760576
10 May 1996
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1396515
9 January 1996
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1367605
23 July 1995
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 124959
21 February 1995
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1363197
25 January 1994
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401811
2 April 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1366810
29 June 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 646388
5 May 1992
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1262901
9 April 1991
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1231134
10 December 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1212191
7 November 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1226440
5 May 1989
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 892564
4 November 1988
Re-Inspection · MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 893692
21 July 1988
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1340459
16 June 1988
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1205328
19 November 1987
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1027729
16 December 1986
Re-Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1002553
28 April 1986
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1307709
23 January 1986
Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1303442
25 November 1985
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1300493
11 October 1985
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1302692
5 May 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280518
9 May 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964932
Deck/Cargo
Issued 9 January 1996
Resolved
MAKE READY FOR INSPECTION (INTERNAL) ALL DRY BULK TANKS. THIS REQUIREMENT IS TO BE COMPLETED AT NEXT DRYDOCKING.
Condition: Unknown
Due 9 January 1996
Resolved 9 January 1996
Deck/Cargo
Issued 2 April 1993
Resolved
MAKE FOUR (4) DRY BULK "P TANKS" AVAILABLE FOR INTERNAL INSPECTION NOT LATER THAN NEXT DRYDOCK DATE.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Deck/Cargo
Issued 2 April 1993
Resolved
REPLACE BURNED OUT MAGNETIC STARTER COILS AND PROVE PROPER OPERATION OF ANCHOR WINDLASS.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Engineering
Issued 5 May 1992
Resolved
REMOVE IMPROPER HYD. LINES & FITTINGS AFT OF BOTH ENGINES. REPLACES WITH PROPER APPROVED FITTINGS AND HOSES I.A.W. 46CRF56.60-25(C)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Documentation
Issued 5 May 1992
Resolved
PROVIDE COPY OF CURRENT ABS SURVEY TO COGNIZANT USCG OCMI (INSPECTOR)._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Electrical
Issued 5 May 1992
Resolved
COVER OPEN AREAS IN THE GALLEY BREAKER PANEL.
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Electrical
Issued 5 May 1992
Resolved
MAIN SWITCHBOARD IN E/R. PROPERLY INSTALL CIRCUIT BREAKER COVER. COVER ISNOW LOOSE AND LEAVES GAPS AROUND SIDES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Engineering
Issued 5 May 1992
Resolved
REMOVE EXCESSIVE ELECTRICAL WIRE "BUNDLE" ON BOTH MAIN ENGINES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Electrical
Issued 5 May 1992
Resolved
REPLACE TACHS ON BOTH GENERATORS AND PROVE OVER SPEED SETTINGS TO SATISFACTION OF USCG MARINE INSPECTOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Navigation
Issued 9 April 1991
Resolved
E1. INSTALL MEANS TO MONITOR THE SPEED OF MAIN PROPULSION SHAFTS (TACHOMETER SHAFTS), AS PER NVIC 1-78 ENCLOSURE (1).
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Deck/Cargo
Issued 16 June 1988
Resolved
INSTALL ADEQUATE SIZE/WEIGHT ANCHOR FOR CLASS OF VESSEL STARBOARD SIDE.
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Unknown
Issued 5 May 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL POURCIAU TIDE, DN619718.
Condition: Unknown
Due 5 May 1984
Resolved 5 May 1984
Navigation
Issued 5 May 1984
Resolved
PROCURE LATEST EDITION OF SAILING DIRECTIONS AND LIGHT LIST.
Condition: Unknown
Due 5 May 1984
Resolved 5 May 1984
Construction/Loadline
Issued 5 May 1984
Resolved
RENEW BALLAST AND OILY WATER SEPERATOR PUMP REMOTE SHUTDOWN SWITCH.
Condition: Unknown
Due 5 May 1984
Resolved 5 May 1984
Lifesaving
Issued 5 May 1984
Resolved
INSTALL A COAST GUARD CERTIFIED AND INSPECTED 25 MAN OCEAN LIFERAFT TO RE- PLACE THE BRAZILIAN INSPECTED 25 MAN LIFERAFT.
Condition: Unknown
Due 5 May 1984
Resolved 5 May 1984
Unknown
Issued 5 May 1984
Resolved
LABEL ALL FIRE STATIONS IN ACCORDANCE WITH 46 CFR 97.37-15.
Condition: Unknown
Due 5 May 1984
Resolved 5 May 1984
Unknown
Issued 5 May 1984
Resolved
REINSTALL FIXED CO2 BOTTLE FOR PAINT LOCKER AND PROVIDE SERVICE REPORT.
Condition: Unknown
Due 5 May 1984
Resolved 5 May 1984
Unknown
Issued 5 May 1984
Resolved
REPAIR AND REINSTALL GYROCOMPASS.
Condition: Unknown
Due 5 May 1984
Resolved 5 May 1984
Unknown
Issued 5 May 1984
Resolved
PLACE ON BOARD VESSEL A COMPLETE FIRST AID KIT.
Condition: Unknown
Due 5 May 1984
Resolved 5 May 1984
Electrical
Issued 5 May 1984
Resolved
STENCIL STOVE DISCONNECT OUTSIDE GALLEY POWER PANEL.
Condition: Unknown
Due 5 May 1984
Resolved 5 May 1984
Electrical
Issued 5 May 1984
Resolved
INSTALL BLANK COVERS FOR POWER PANEL IN GALLEY.
Condition: Unknown
Due 5 May 1984
Resolved 5 May 1984
Lifesaving
Issued 5 May 1984
Resolved
PROPERLY LABEL LIFERAFT STATIONS IN ACCORDANCE WITH 46 CFR 97.37-40.
Condition: Unknown
Due 5 May 1984
Resolved 5 May 1984