MAURY USCG vessel records Sign in
← All vessels

GULF FLEET NO. 39

GULF FLEET NO. 39 is a 1980 offshore supply vessel. The Coast Guard has recorded 16 inspections since 1985, most recently in November 1990, along with 42 deficiencies.

Records from 1985 to 1990. Most recent: inspection, 6 November 1990.

Built
1980
Last inspected
6 November 1990
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7923457 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
UNITED STATES
—
Maury page id
psix-51472

Inspections, by type

Years with a record 6 calendar years (1985–1990)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 36 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it196 - Regulatory (Subpart C or D), Net Ton
289 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 16

6 November 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1226904
26 March 1990 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1223055
6 October 1989 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1219986
1 June 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1201857
22 May 1989 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1034993
6 October 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 891800
27 June 1988 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1032039
12 March 1988 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1030279
21 December 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1314096
24 October 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1332721
15 October 1987 MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1327845
15 October 1987 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1327846
19 December 1986 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1001155
5 November 1986 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1329094
5 October 1986 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1329092
4 October 1985 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1305708

Deficiency record · 42

Fire Fighting
Issued 6 October 1989 Resolved
PROVIDE VESSELS NAME ON GALLEY FIRE AX.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Electrical
Issued 6 October 1989 Resolved
PROVIDE GREASE SCREEN ABOVE THE STOVE, REMOVE WIRING AND REPAIR FAN.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Electrical
Issued 6 October 1989 Resolved
FIX CREWS TOILET AND INSTALL LIGHT COVERS ABOVE CREW HEAD SINKS.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Electrical
Issued 6 October 1989 Resolved
REPAIR BUNK LIGHT IN MAIN DECK FORWARD CABIN PORT SIDE BOTTOM BUNK.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Electrical
Issued 6 October 1989 Resolved
INSTALL NEWLIGHT COVER TO OVERHEAD LIGHT IN MAIN DECK PORTSIDE AFT CABIN.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Electrical
Issued 6 October 1989 Resolved
PROVIDE BUNK LIGHT COVER TO FWD CABIN 01 LEVER.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Lifesaving
Issued 6 October 1989 Resolved
PROVIDE NEW LIFEJACKET LIGHTS ON ALL PFD'S AND 5 WHISTLES.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Fire Fighting
Issued 6 October 1989 Resolved
PROVIDE SPARE AIR BOTTLE TO SCBA AND HYDROSTATICALLY TEST THE ONE THAT IS ABOARD.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Lifesaving
Issued 6 October 1989 Resolved
PROVIED 3 USCG APPROVED TYPE 1 LIFEJACKET. UNTIL THIS REQUIREMENT IS COMPLIED WITH THE MAXIMUM NUMBER OF PERSONS ALLOWED ONBOARD IS 14.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Fire Fighting
Issued 6 October 1989 Resolved
PROVIDE UPDATED FIXED AND PORTABLE FIREFIGHTING EQUIPMENT CERTIFICATE TO OCMI.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Electrical
Issued 6 October 1989 Resolved
PROVIDE GLOBE FOR LIGHT IN MAIN DECK STBD SIDE LOCKER.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Deck/Cargo
Issued 6 October 1989 Resolved
SECURELY FASTEN ALL 02-ACYETOLINE BOTTLES TO MAIN DECK.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Engineering
Issued 6 October 1989 Resolved
PROVIDE LABELS FOR SHUTDOWNS OUTSIDE MAIN DECK STBD SIDE EMERGENCY ESCAPE HATCH.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Engineering
Issued 6 October 1989 Resolved
STENCIL EMERGENCY FUEL OIL SHUT OFFS ON MAIN DECK.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Fire Fighting
Issued 6 October 1989 Resolved
PROVIDE FIXED CO2 SYSTEM IN PAINT LOCKER.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Electrical
Issued 6 October 1989 Resolved
REPAIR LIFERFT LIGHT AFT OF 01 LEVEL.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Construction/Loadline
Issued 6 October 1989 Resolved
RESTENCIL ENGINE ROOM PASSAGEWAY GENERAL ALARM BELL STATION.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Fire Fighting
Issued 6 October 1989 Resolved
PROVIDE FIRE STATION STENCIL AND PROVIDE SPANNER WRENCH TO FIRE STATION TO AFT 01 LEVEL.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Lifesaving
Issued 6 October 1989 Resolved
PROVIDE NEW CARTRIDGES FOR LINE THROWING GUN.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Construction/Loadline
Issued 6 October 1989 Resolved
PROVIDE BALLAST VALVE HANDLES ON BOTH BALLAST PIPES FROM AFTER PEAK TANK INAFTER STEERING.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Engineering
Issued 6 October 1989 Resolved
PROVIDE MAIN ENGINE FUEL OIL DRIP SHIELDS.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Engineering
Issued 6 October 1989 Resolved
REPLACE BROKEN GLASS ON FUEL OIL SEPERATOR PUMP.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Electrical
Issued 6 October 1989 Resolved
PROVIDE PROOF OF PROPER OPERATION OF PORT TO STBD GENERATOR, REVERSE POWER RELAY.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Engineering
Issued 6 October 1988 Resolved
REMOVE TOW WINCH AIR RECEIVER FROM SERVICE OR PROVE ASME STD. AND HYDROSTATICALLY TEST TO 1.5 MAWP.
Condition: Unknown
Due 6 October 1988
Resolved 6 October 1988
Lifesaving
Issued 6 October 1988 Resolved
PROVIDE SERVICE REPORTS AND STATEMENT OF INSTALLATION FROM MASTER FOR LIFE RAFTS AND HYDROSTATIC RELEASES.
Condition: Unknown
Due 6 October 1988
Resolved 6 October 1988
Engineering
Issued 6 October 1988 Resolved
REPAIR PORT MDE HIGH J/W TEMP ALARM.
Condition: Unknown
Due 6 October 1988
Resolved 6 October 1988
Electrical
Issued 6 October 1988 Resolved
REPAIR L/D TEMP ALARMS ON #1 & 2 S/S GENERATORS.
Condition: Unknown
Due 6 October 1988
Resolved 6 October 1988
Engineering
Issued 12 March 1988 Resolved
PROVIDE PROPER PRESSURE RECEIVING DEVICE FOR TOWING WINCH AIR RECEIVER (HAND LIFTING DEVICE REQ).
Condition: Unknown
Due 12 March 1988
Resolved 12 March 1988
Engineering
Issued 12 March 1988 Resolved
CONDUCT 1.25 MAWP HYDROSTATIC TEST OF TOWING WINCH AIR RECEIVER.
Condition: Unknown
Due 12 March 1988
Resolved 12 March 1988
Documentation
Issued 15 October 1987 Resolved
PROVE TO THE SATISFACTION OF [name withheld] THAT THE VESSEL HAS HAD A CREDIT DRY- DOCK SINCE FEB 85. WITHOUT SATISFACTORY DOCUMENTATION OF THAT DRYDOCK, THE VESSEL MUST UNDERGO A CREDIT DRYDOCK ATTENDED BY A COAST GUARD MARINE INSPECTOR PRIOR TO 15 NOVEMBEAR 1987.
Condition: Unknown
Due 15 October 1987
Resolved 15 October 1987
Unknown
Issued 15 October 1987 Resolved
REPAIR S/P PHONE AND ATTACHED BELL TO PROPER OPERATION AND CLEAR COMMUNICA-TION TO WHEELHOUSE IN RUDDER ROOM.
Condition: Unknown
Due 15 October 1987
Resolved 15 October 1987
Engineering
Issued 15 October 1987 Resolved
PROVE PROPER OPERATION OF #1 AND #2 MDE HIGH JACKET WATER TEMPERATURE ALARM
Condition: Unknown
Due 15 October 1987
Resolved 15 October 1987
Navigation
Issued 15 October 1987 Resolved
REPLACE MISSING WINDOW WIPER ON BRIDGE.
Condition: Unknown
Due 15 October 1987
Resolved 15 October 1987
Navigation
Issued 15 October 1987 Resolved
PLACE "NOT UNDER COMMAND" LIGHTS IN POSITIONS IN ACCORDANCE WITH INTERNA- TIONAL RULES OF THE ROAD, ANNEX I, SECTION (2)(I).
Condition: Unknown
Due 15 October 1987
Resolved 15 October 1987
Engineering
Issued 15 October 1987 Resolved
REPLACE WASTED PIPING LOCATED IN THE AFT ENGINE CONTROL CONSOLE.
Condition: Unknown
Due 15 October 1987
Resolved 15 October 1987
Construction/Loadline
Issued 15 October 1987 Resolved
MAKE REPAIRS TO SOFT PATCHED PIPING WITH NEW PIPING LOCATED IN BALLAST PIPING TO NO. 11 AND 12 BALLAST TANK, PASSAGEWAY TO STEERING FLAT.
Condition: Unknown
Due 15 October 1987
Resolved 15 October 1987
Engineering
Issued 5 October 1986 Resolved
REPAIR SIGHT GLASS FOR STBD FUEL OIL TANK.
Condition: Unknown
Due 5 October 1986
Resolved 5 October 1986
Accommodation/Occupational Safety
Issued 5 October 1986 Resolved
CLEAN GALLEY VENT LOAD AND REPLACE MISSING VENT FAN.
Condition: Unknown
Due 5 October 1986
Resolved 5 October 1986
Electrical
Issued 5 October 1986 Resolved
REPAIR OUTLET BOX BEHIND ENGINEROOM WORKBENCH.
Condition: Unknown
Due 5 October 1986
Resolved 5 October 1986
Electrical
Issued 5 October 1986 Resolved
REPAIR OUTLET BOX BEHIND #2 MAIN ENGINE JUST BELOW BATTERY CHARGER.
Condition: Unknown
Due 5 October 1986
Resolved 5 October 1986
Accommodation/Occupational Safety
Issued 5 October 1986 Resolved
PROVIDE A COAST GUARD APPROVED FIRST AID KIT.
Condition: Unknown
Due 5 October 1986
Resolved 5 October 1986
Accommodation/Occupational Safety
Issued 5 October 1986 Resolved
PROVIDE BUNK CARDS FOR ACE BUNKS.
Condition: Unknown
Due 5 October 1986
Resolved 5 October 1986

Ownership record