MAURY USCG vessel records Sign in
← All vessels

ACADIAN EXPRESS

ACADIAN EXPRESS is a 1979 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 1985, most recently in June 1992, along with 15 deficiencies.

Records from 1985 to 1992. Most recent: inspection, 8 June 1992.

Built
1979
Last inspected
8 June 1992
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WAJ6889
Flag
UNITED STATES
—
Maury page id
psix-51492

Inspections, by type

Years with a record 8 calendar years (1985–1992)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 34 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it64 - Regulatory (Subpart C or D), Net Ton
95 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WAJ6889MMSI not assigned · cancelled · compulsorily equipped · granted 12 January 1995, cancelled 4 March 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 15

8 June 1992 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1268084
28 April 1992 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 946685
15 November 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1258974
8 January 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1226943
17 December 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1220056
22 November 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1257046
21 October 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 933138
20 October 1990 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1244778
6 October 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1323420
25 April 1989 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 889169
7 October 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 891490
29 September 1987 Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1014704
25 September 1986 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1007339
17 March 1986 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 997917
25 September 1985 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 993003

Deficiency record · 15

Fire Fighting
Issued 15 November 1991 Resolved
FILL EMPTY 100LB, CO2 CYLINDER (#5151380) FOR MACHINERY SPACE FIXED EXTINGUISHING SYSTEM.
Condition: Unknown
Due 15 November 1991
Resolved 15 November 1991
Fire Fighting
Issued 15 November 1991 Resolved
HAVE ALL THREE 100LB CO2 CYLINDERS PROPERLY HYDRO-TESTED (RSPA FACILITY) FOR MACHINERY SPACE FIXED EXTINGUISHING SYSTEM OR REPLACE WITH FILLED CYLINDERS PROPERLY HYDRO-TESTED WITHIN PAST 10 YEARS.
Condition: Unknown
Due 15 November 1991
Resolved 15 November 1991
Construction/Loadline
Issued 20 October 1990 Resolved
REMOVE EXISTING TOP SECTION OF HALF ROUND PIPE RUB RAIL ON STERN AND RENEW IN LIFE KIND AND QUALITY AS ORIGINAL APPROX 4 INCH BY 15 FT.
Condition: Unknown
Due 20 October 1990
Resolved 20 October 1990
Documentation
Issued 20 October 1990 Resolved
PERMANENTLY MARK THE VSL WITH FORWARD AND AFT DRAFT MARKS TO ENABLE OPERATORS TO COMPLY WITH DRAFT LIMIATION NOTED IN 17 DEC 1974 USCG STABILITY LETTER ISSUED BY [name withheld].
Condition: Unknown
Due 20 October 1990
Resolved 20 October 1990
Engineering
Issued 6 October 1989 Resolved
INSTALL A RELIEF VALVE OF NOT LESS THAN ONE INCH DIAMETER AND NOT MORE THAN50 PSI ON POTABLE WATER HEAD TANK.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Construction/Loadline
Issued 25 April 1989 Resolved
VESSEL NAME AND HAILING PORT REPAINTED ON TRANSOM WHERE MISSING.
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Construction/Loadline
Issued 25 April 1989 Resolved
MAKE PERMANENT THE TEMPORARY REPAIRS TO THE PORT AND STARBOARD AFT CORNERS WHERE INSET. CROP AND RENEW THE CORNERS, WITH INSERT TO EXTEND BEYOND THE VERTICAL STIFFENERS AT EACH SIDE FORMING THE TURN OF THE CORNER.
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Navigation
Issued 7 October 1988 Resolved
REPAIR RUDDER ANGLE INDICATORS ON BRIDGE TO SHOW FULL MOVEMENT OF RUDDERS.
Condition: Unknown
Due 7 October 1988
Resolved 7 October 1988
Engineering
Issued 7 October 1988 Resolved
FIT ALL RACOR FUEL FILTERS WITH MARINE KITS.
Condition: Unknown
Due 7 October 1988
Resolved 7 October 1988
Engineering
Issued 7 October 1988 Resolved
REPLACE GUARDS OVER PULLEYS/FLY WHEELS ON ALL THREE MAIN DIESEL ENGINES.
Condition: Unknown
Due 7 October 1988
Resolved 7 October 1988
Construction/Loadline
Issued 7 October 1988 Resolved
REMOVE SPLASH SHIELD FROM EMERGENCY ESCAPE HATCH IN THE FORWARD PASSENGER ACCOMODATION.
Condition: Unknown
Due 7 October 1988
Resolved 7 October 1988
Navigation
Issued 7 October 1988 Resolved
REPLACE EXISTING NAVIGATION LIGHTS WITH COAST GUARD APPROVED NAVIGATION LIGHTS.
Condition: Unknown
Due 7 October 1988
Resolved 7 October 1988
Deck/Cargo
Issued 7 October 1988 Resolved
REPLACE 110 FT ANCHOR LINE WITH ANCHOR LINE WHICH IS AT LEAST 600 FT LONG AND MAKE FWD ANCHOR WINDLASS OPERATIONAL.
Condition: Unknown
Due 7 October 1988
Resolved 7 October 1988
Construction/Loadline
Issued 7 October 1988 Resolved
PAINT VESSELS NAME AND HOME PORT STERN OF VESSEL. THIS SHOULD BE PLACED ON THE STERN IN SUCH A MANNER AS TO NOT BE OBSTRUCTED BY DOCKING FENDERS.
Condition: Unknown
Due 7 October 1988
Resolved 7 October 1988
Fire Fighting
Issued 7 October 1988 Resolved
REPLACE NON COAST GUARD APPROVED CHEMICAL FIRE EXTINGUISHERS WITH COAST GUARD APPROVED B-II DRY CHEMICAL EXTINGUISHERS.
Condition: Unknown
Due 7 October 1988
Resolved 7 October 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.