Records from 1982 to 2017. Most recent: operational control imposed, 30 June 2017.
Inspection history · 139
29 June 2017
CCSSC Examination · Administrative Inspection · Deficiency Check · PII Safety Exam · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6182206
29 June 2017
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6191086
5 June 2017
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6166658
19 April 2017
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6128501
30 March 2017
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6110424
21 February 2017
PII Safety Exam · ISPS II Exam · CCSSC Examination · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6091741
22 August 2016
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5979521
2 August 2016
ISPS III Exam · CCSSC Examination · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5959240
17 April 2016
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5855763
2 April 2016
CCSSC Examination · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5845758
16 January 2016
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5798600
15 December 2015
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5781855
10 December 2015
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5779036
7 December 2015
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5776762
2 December 2015
ISPS II Exam · Deficiency Check · CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5773137
26 August 2015
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5226836
28 July 2015
ISPS III Exam · Ballast Water Examination · CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5196044
3 June 2014
ISPS III Exam · CCSSC Examination · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4877981
13 March 2014
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4815560
4 March 2014
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4809821
18 July 2012
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4384036
17 July 2012
ISPS II Exam · CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4381444
22 June 2012
ISPS II Exam · CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4351851
10 January 2012
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4224807
13 December 2011
CCSSC Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4206539
4 February 2011
Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3939096
25 January 2011
ISPS III Exam · Ballast Water Examination · CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3932365
28 October 2010
ISPS II Exam · Ballast Water Examination · CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3879623
2 March 2010
CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3688273
3 January 2010
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3657882
2 December 2009
ISPS III Exam · CCSSC Examination · NPV Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3643137
29 July 2009
ISPS II Exam · CCSSC Examination · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3549313
10 February 2009
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3415357
28 January 2009
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3401567
8 October 2008
PII Safety Exam · ISPS II Exam · CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3340931
17 September 2008
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3326839
13 July 2008
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3266225
25 June 2008
PII Safety Exam · ISPS II Exam · CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3247338
11 March 2008
STCW 95 Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3162406
20 February 2008
ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3160039
30 January 2008
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3138932
22 October 2007
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3084822
27 July 2007
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3009115
24 July 2007
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3007367
5 July 2007
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2983997
22 June 2007
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2970051
14 February 2007
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2871896
25 October 2006
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2808026
19 October 2006
Random ISPS/MTSA-No PSC
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2803023
18 October 2006
Random ISPS/MTSA/PSC
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2803254
19 September 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2781689
15 June 2006
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2680739
23 April 2006
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2631319
22 March 2006
ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2608701
20 January 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2569847
19 January 2006
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2569253
19 January 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2569416
13 September 2005
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2490984
28 June 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2406613
19 March 2005
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2317228
18 March 2005
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2311309
1 March 2005
PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2301524
18 February 2005
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2295115
8 January 2005
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2271075
16 December 2004
Random ISPS/MTSA/PSC
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2259649
3 December 2004
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2251856
19 November 2004
Random ISPS/MTSA/PSC
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2239241
12 September 2004
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2232892
18 August 2004
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2169549
15 August 2004
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2166287
30 June 2004
ISPS II Exam
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2116297
24 February 2004
MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2009021
26 November 2003
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1954960
14 November 2003
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1949206
4 November 2003
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1942016
4 November 2003
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1942335
27 August 2003
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1889068
12 August 2003
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1870208
18 June 2003
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1820505
24 March 2003
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1761109
21 February 2003
Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1747784
20 July 2002
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1648210
22 May 2002
Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1618987
31 January 2002
Re-Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1482587
10 April 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 289258
29 February 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 275854
21 September 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 433062
10 March 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 426387
2 February 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 425191
22 July 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 418406
6 July 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 210278
6 July 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 757595
15 April 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 414883
10 April 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 414701
7 April 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 414461
31 March 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 414331
12 January 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 411817
17 July 1997
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 405719
20 March 1997
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 401756
28 February 1997
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 401021
20 February 1997
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 649762
14 February 1997
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 400597
11 February 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 192479
11 February 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 757586
22 January 1997
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 399789
17 January 1997
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 649757
10 January 1997
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 399523
6 December 1996
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 398246
26 October 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 396798
11 March 1996
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 192480
11 March 1996
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 753442
1 February 1996
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 387623
6 November 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 385119
27 June 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 368112
27 June 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1356796
28 April 1994
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 366627
22 April 1994
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 366619
27 October 1993
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 174869
3 August 1993
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 649758
28 July 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 359871
16 July 1993
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 360133
7 July 1993
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 649759
2 July 1993
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 165487
15 December 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 355128
8 December 1992
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 649755
12 November 1992
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 355007
19 February 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 348893
22 August 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 649756
5 October 1988
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1200184
19 October 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 319214
24 March 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1034145
23 February 1987
COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015645
9 April 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1008084
28 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 981070
24 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983120
9 April 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974182
21 March 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1279401
20 March 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 965478
16 March 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1272949
Construction/Loadline › Hull › Hull Plating
Issued 29 June 2017
No resolution recorded
The Administration shall satisfy itself that the general structural strength of the hull is sufficient for the draught corresponding to the freeboard assigned. The material strength of the main bulkhead deck, is severely wasted and compromised; allowing water to drip directly into the main machinery space and lazerette. See Form B. ICLL 66, Annex I / Reg. 1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Deck/Cargo › Ballast › Tank
Issued 29 June 2017
No resolution recorded
The Administration shall satisfy itself that the general structural strength of the hull is sufficient. The aft ballast tanks, located in a passageway openly connected to the lazerette, are severely wasted and filled to the point of overflowing through the penetrations. The lazerette is not equpped with a bilge alarm. See Form B. ICLL 66 Annex I / Reg. 1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Operations/Management › Drills/Instruction › Fire
Issued 29 June 2017
Resolved
A ship when in a port of another Contracting Government is subject to control by officers duly authorized by such Government concerning operational requirements in respect of the safety of ships. The crew failed to adequately perform a fire drill during the course of the exam. See Form B. 74 SOLAS (2014) Ch. XI-1 / Reg. 4.1
Action required: 10 - Deficiency Rectified
Resolved 30 November 2018
Resolution: The temporary delivery crew performed satisfactory drills.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 29 June 2017
Resolved
Deficiencies which may be deemed to pose a danger to persons, property or the environment include the following: failure to comply with the applicable safe manning requirements of the Administration. The Minimum Safe Manning Certificate requires deck ratings of II/2 and II/1; both Master and Deck Officer hold II/3. STCW I/4.2.2
Action required: 10 - Deficiency Rectified
Resolved 30 November 2018
Resolution: The crew met the Minimum Safe Manning Document.
Personnel › Certificates/Documents/Licenses › MMD, GMDSS At-sea Maintainer
Issued 29 June 2017
Resolved
Deficiencies which may be deemed to pose a danger to persons, property or the environment include the following: failure to hold a certificate, to have an appropriate certificate, to have a valid dispensation or to provide documentary proof that an application for an endorsement has been submitted. The master did not have a valid endorsement for GMDSS or SSO training. STCW I/4.2.1
Action required: 10 - Deficiency Rectified
Resolved 30 November 2018
Resolution: Master had valid license.
Operations/Management › Vessel Safety Management › Resources and Personnel
Issued 29 June 2017
Resolved
Each Administration shall, for the purpose of preventing fatigue: establish and enforce rest periods for watch-keeping personnel and those whose duties involve designated safety, security and prevention of pollution duties. The vessel does not have a work rest schedule, and the master stated he had been awake without rest for 26 hours. STCW VIII/1
Action required: 10 - Deficiency Rectified
Resolved 30 November 2018
Resolution: The vessel will make a short voyage to dry-dock.
Stability › Weathertight Integrity › General
Issued 29 June 2017
Resolved
All access openings in bulkheads at ends of enclosed superstructures shall be fitted with doors of steel or other equivalent material, stiffened and fitted so that the whole structure is of equivalent strength to the unpierced bulkhead and weathertight when closed. The steel door connecting the galley to the cargo deck could not be sealed weathertight. ICLL 66 Annex I / Reg. 12(1)
Action required: 10 - Deficiency Rectified
Resolved 30 November 2018
Resolution: Door adjusted and new rubber gasket installed.
Fire Fighting › Ventilation Systems › Ducts
Issued 29 June 2017
Resolved
Satisfactory means, permanently attached, shall be provided for closing the openings of air pipes. The goose necks astern of the windlass are fitted with rubber tubing that would not satisfactorily close the vent in an emergency. ICLL 66 Annex I / Reg. 20
Action required: 10 - Deficiency Rectified
Resolved 30 November 2018
Resolution: Goosenecks would close vents.
Personnel › Training › GMDSS
Issued 29 June 2017
Resolved
The form of the endorsement used shall be that set forth in paragraph 3 of section A-I/2 of the STCW Code. The Deck Officer GMDSS endorsement does not include the number of the certificate for which it is attesting. STCW I/2.7
Action required: 10 - Deficiency Rectified
Resolved 30 November 2018
Resolution: The deck officer had GMDSS testing.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 29 June 2017
No resolution recorded
The electrical power available shall be sufficient to supply all those services that are essential for safety in an emergency. The emergency generator could not continue operating – without a load – for longer than 20 seconds before faltering and turning off, after more than a dozen attempts by the crew to start it and attempts to correct the issue. CCSSC 2.29.5
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Electrical › Electric Generation Source (emergency) › Generator
Issued 29 June 2017
No resolution recorded
Where the emergency source of power is a generator, it shall be automatically started and connected to the emergency switchboard within 45 s of the loss of the main source of electrical power. It shall be driven with an independent fuel supply having a flashpoint not less than 43 degrees Celsius. A standby emergency generator was brought onboard that is fueled by gasoline. CCSSC 2.29.8
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Lifesaving › Launching Appliances › Davit
Issued 29 June 2017
Resolved
Life-saving appliances required by this chapter shall comply with the technical specifications of the LSA Code and National Regulations as appropriate. The vessel's rescue boat davit relies on electric power and does not have the weighted brake to operate the winch. CCSSC 4.3.1 LSA 6.1.1.3
Action required: 10 - Deficiency Rectified
Resolved 30 November 2018
Resolution: The winch was operational.
Lifesaving › Launching Appliances › Davit
Issued 29 June 2017
Resolved
Life-saving appliances required by this chapter shall comply with the technical specifications of the LSA Code and National Regulations as appropriate. The davit arm and winch should be rated for 7,227lbs and 9,636lbs, respectively. The rescue boat davit arm is stenciled with "SWL 2,000LBS" and davit winch is only rated to 4,000 lbs. CCSSC 4.3.1
LSA 6.1.1.6
Action required: 10 - Deficiency Rectified
Resolved 30 November 2018
Resolution: New davit arm was installed.
Lifesaving › Launching Appliances › Davit
Issued 29 June 2017
No resolution recorded
The owner or Master of every ship to which this Code applies shall ensure that: the condition of the ship is maintained to conform with the provisions of this Code. The owner or Master of every ship to which this Code applies shall ensure that: the condition of the ship is maintained to conform with the provisions of this Code. CCSSC 1.11.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 29 June 2017
No resolution recorded
Posters or signs shall be provided on or in the vicinity of survival craft and their launching controls. The rescue boat emergency instructions posted at the rescue boat davit are for a fast rescue boat which does not match the rescue boat onboard. 74 SOLAS (2014) Ch. III / Reg. 9.2.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Lifesaving › Rescue Boat › Markings
Issued 29 June 2017
No resolution recorded
Lifesaving appliances required by this chapter shall comply with the technical specifications of the LSA Code and national regulations as appropriate. The rescue boat's affixed approval plate does not state compliance with SOLAS/LSA or an equivalent, nor is there a certificate or declaration of conformity onboard. CCSSC 4.3.1 LSA 5.1.1.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Lifesaving › Rescue Boat › Propulsion Engine
Issued 29 June 2017
Resolved
The owner or Master of every ship to which this Code applies shall ensure that the condition of the ship and its equipment is maintained to conform with the provisions of this Code. The rescue boat motor is in poor condition and unable to run continuously without repeatedly restarting it underway. CCSSC 1.11.1
Action required: 10 - Deficiency Rectified
Resolved 30 November 2018
Resolution: The rescue boat was tested underway.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 29 June 2017
No resolution recorded
Administration shall provide the ship with an appropriate document as evidence of compliance of construction and equipment with the requirements of this regulation. The certificate allows Dangerous Goods to be stowed on the main open ro-ro deck centrally over the engine room which does not have A-60 structural fire protection insulation. 74 SOLAS (2014) Ch. II-2 / Reg. 19.4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 29 June 2017
Resolved
A fireman's outfit shall consist of personnel equipment comprising protective clothing of material to protect the skin from the heat radiating from the fire and from burns and scalding by steam. One fireman outfit is missing a flashhood which leaves exposed skin around the SCBA mask and the rigid helmet. CCSSC 3.11.2.1.1
Action required: 10 - Deficiency Rectified
Resolved 30 November 2018
Resolution: Firemen outfits were brand new.
Fire Fighting › Fire Main › Condition
Issued 29 June 2017
No resolution recorded
All fire protection systems and appliances shall at all times be in good order and available for immediate use while the ship is in service in line with Flag State requirements. The fire main piping in way of the ladder leading from the mess room to the central passageway was compromised and leaking water at a high pressure. CCSSC 3.6.12
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Fire Hoses › Condition
Issued 29 June 2017
Resolved
The owner or Master of every ship to which this Code applies shall ensure that: the condition of the ship and its equipment is maintained to conform with the provisions of this Code to ensure that the ship in all respects will remain fit to proceed to sea. Three fire hoses were observed deteriorated and excessively leaking. CCSSC 1.11.1
Action required: 10 - Deficiency Rectified
Resolved 30 November 2018
Resolution: Fire hoses were in good condition.
Accommodation/Occupational Safety › Ventilation › General
Issued 29 June 2017
No resolution recorded
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the spaces being ventilated. The starboard main engine room shaft does not seal tight when the fire damper steel plate is slid in place, and the hinged galley fire damper was missing its wing-nut prong making closure as designed impossible. CCSSC 3.17.6.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 29 June 2017
No resolution recorded
All ships shall be provided with a permanently exhibited fire control plan or equivalent to the satisfaction of the Administration. The fire control plan in the mess room is dated 1990, handwritten, and does not match the vessel’s current arrangement approved by the vessel's current and previous Recognized Organizations. CCSSC 3.13.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 29 June 2017
No resolution recorded
The owner or Master of every ship to which this Code applies shall ensure that: the condition of the ship and its equipment is maintained to conform with the provisions of this Code to ensure that the ship in all respects will remain fit to proceed to sea. The port side anchor chain is severely deteriorated with multiple spanner bars compromised or missing. CCSSC 1.11.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Deck/Cargo › Mooring/Anchoring › Anchoring Arrangement
Issued 29 June 2017
No resolution recorded
Moving parts of machinery which are so exposed as to cause accidents shall be properly guarded. The machinery guard on the windlass motor is wasted and subsequently is a rotational hazard. CCSSC 2.12.6
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 June 2017
No resolution recorded
A vessel shall carry a first aid kit approved by the Administration. There were two first aid kits onboard, not including the rescue boat's, and both were nearly empty. CCSSC 8.8.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Communications › Radio Communications › VHF Radiotelephone
Issued 29 June 2017
Resolved
The VHF radio installation, required by regulation 7.1.1, shall also be capable of transmitting and receiving general radio communications using telephony. The vessel does not have a telephony capable radio. CCSSC 5.1.1, 74 SOLAS (2014) Ch. IV / Reg. 8.2
Action required: 10 - Deficiency Rectified
Resolved 30 November 2018
Resolution: Tested VHF radio.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 29 June 2017
No resolution recorded
Every ship engaged in voyages beyond sea area A1, but remaining within sea area A2, shall be provided with: an MF radio installation capable of transmitting and receiving, for distress and safety purposes, on the frequencies 2, 187.5 kHz using DSC; and 2,182 kHz using radio telephony. The vessel is not equipped with an MF radio. CCSSC 5.1.1, 74 SOLAS (2014) Ch. IV / Reg. 9.1.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 29 June 2017
No resolution recorded
Ships of 300 gross tonnage and over to which this code applies shall comply with the provisions of Chapter IV of the SOLAS Convention as amended. The vessel was not equipped with a radio installation operating on the indicated working frequencies. CCSSC 5.1.1, 74 SOLAS (2014) Ch. IV / Reg. 9.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 29 June 2017
No resolution recorded
Ship owners shall effect a shore-based radio equipment maintenance contract with a service supplier authorised by the administration or recognized organsation for the performance of this function. The vessel does not have a shore-based maintenance contract. CCSSC 5.5.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 29 June 2017
No resolution recorded
Fire extinguishers under expected conditions of use gives off toxic gases in such quantities as to endanger persons shall not be used. A 50LB semi-portable bottle of CO2 has been placed onboard which, when discharged in the enclosed machinery space, would prove fatal to the responding crew member. CCSSC 3.6.7
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Documentation › Logs/Records › Logbook (official)
Issued 29 June 2017
No resolution recorded
The master shall ensure that the frequency of drills performed shall not exceed the following frequencies if weather and circumstances permit, Enclosed Spaces - quarterly. There is no record of enclosed space training documented in the official logbook, and the crew was unfamiliar with the requirement. CCSSC 7.4.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Documentation › Manuals/Policy Documentation › Steering Gear Changeover Instructions
Issued 29 June 2017
No resolution recorded
Simple operating instructions with a block diagram showing the change-over procedures for remote steering gear control systems and steering gear power units shall be permanently displayed on the navigation bridge and in the steering compartment. The vessel does not have a display with block diagrams on the bridge or steering compartment. 74 SOLAS (2014) Ch. V / Reg. 26.3.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Navigation › Piloting/Steering › Magnetic Compass
Issued 29 June 2017
No resolution recorded
All ships of 150 gross tonnage and upwards shall, in addition to the requirements of paragraph 2.1, be fitted with: a spare magnetic compass, interchangeable with the magnetic compass referred to in paragraph 2.1.1. The vessel is not equipped with a spare magnetic compass. 74 SOLAS (2014) Ch. V / Reg. 19.2.2.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Electrical › Electric Generation Source (emergency) › Metallic Enclosure/Frame
Issued 29 June 2017
No resolution recorded
Accumulator batteries shall not be located in sleeping quarters. The Administration may permit relaxation from this requirement where hermetically sealed batteries are installed. The vessel has backup batteries stored on the bridge where a bed is present and PSCOs witnessed the master take a nap during the exam. The batteries were not in the provided plastic box. CCSSC 2.27.9.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Documentation › Certificates/Documents › Caribbean Cargo Ship Safety Code Cert. (CCSSC)
Issued 29 June 2017
No resolution recorded
Caribbean Cargo Ship Safety Certificate shall comply with chapters 2, 3, 4, 5 and 6 and any other relevant requirements of this Code. The Caribbean Cargo Ship Safety Certificate lists the vessel's gross regulatory tonnage when it should list and be surveyed under the international tonnage as "gross tonnage," as defined in the Code. CCSSC 1.12.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Personnel › Training › Cargo Safety
Issued 29 June 2017
No resolution recorded
A hazmat employee must receive the training required by this subpart at least once every three years. Master's Hazmat training expired in December 2015. 49 CFR 172.704(c)(2)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Deck/Cargo › Ballast › Tank
Issued 29 June 2017
No resolution recorded
In all ships, means for sounding, to the satisfaction of the Administration, shall be provided: for all tanks and cofferdams. The ballast tanks do not have a means for sounding. CCSSC 2.8
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Communications › Alarms/Indicators › General Alarm
Issued 29 June 2017
No resolution recorded
The general alarm in machinery spaces shall be audible and visible (revolving red light). The silver disc which functions to create the "revolving effect" is stuck in place, and therefore the light bulb is not visible throughout the majority of the machinery space. CCSSC 4.15
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Operations/Management › Ballast Water Managment › Training
Issued 29 June 2017
No resolution recorded
The Ballast Water Management Plan requires periodic training; however, the master stated the crew has not been instructed on ballast water management procedures, and there is no record of such training onboard. 33 CFR 151.2050(h)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Navigation › Collision/Grounding Avoidance › Searchlight
Issued 29 June 2017
Resolved
All ships of 150 gross tonnage and upwards must be fitted with: a daylight signalling lamp, or other means, to communicate by light during day and night. The vessel's daylight signalling lamp does not operate as designed, and therefore does not meet the performance standards of Resolution MSC.95(72). 74 SOLAS (2014), Ch. V / Reg. 19.2.2.2
Action required: 10 - Deficiency Rectified
Resolved 30 November 2018
Resolution: The vessel has three operational daylight signaling lamps.
Engineering › Steering Gear System › Ram
Issued 29 June 2017
No resolution recorded
The owner or Master of every ship to which this Code applies shall ensure that: the condition of the ship and its equipment is maintained to conform with the provisions of this Code. The vessel is fitted with chain and tackle as a tertiary means of steering. The hydraulic ram cylinder in way of the port rudder post is leaking at a rate of one drop per five seconds. CCSSC 1.11.1 (16bc)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 July 2017 — due date passed with no resolution recorded
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 29 June 2017
No resolution recorded
The certificate referred to in 1.12.1 shall be supplemented by a Record of Equipment and Ship Information. The record of equipment states a 50LB bottle of CO2 is required in the engine room contrary to CCSSC 3.6.7; it states the main engine kilo wattage is “1,400 each” when this figure is actually the horsepower (correct kilo wattage is 798 each). CCSSC 1.12.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 July 2017 — due date passed with no resolution recorded
Operations/Management › EPA Vessel General Permit (VGP) › 4.2 #8ii-Bilge Water Recordkeeping
Issued 29 June 2017
No resolution recorded
This permit is effective from December 19, 2013 to December 18, 2018 (i.e., five years). It provides NPDES permit coverage nationwide for discharges incidental to the normal operation of commercial vessels greater than 79 feet in length. The vessel does not have a Vessel General Permit. Vessel General Permit CG-543 Policy Letter 11-01, 33 U.S. Code 1251
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 July 2017 — due date passed with no resolution recorded
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 29 June 2017
No resolution recorded
Vessels greater than or equal to 300 gross tons or having the capacity to hold or discharge 8 cubic meters (2113 gallons) of ballast water must submit a Notice of Intent. The vessel meets the criteria; however, the crew were unaware of the requirement and did not submit a Notice of Intent. VGP Part 1.5.1.1, Part 10 - Appendix E – Notice of Intent (NOI)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 July 2017 — due date passed with no resolution recorded
Deck/Cargo › Ballast › Piping
Issued 29 June 2017
No resolution recorded
The arrangement of the bilge and ballast pumping system shall be such as to prevent the possibility of water passing from the sea and from water ballast spaces into the cargo and machinery spaces. The ballast piping manifold in way of the aft engine room bulkhead has deteriorated and is leaking water at a rate of approximately one gallon per minute. CCSSC 2.18.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Communications › Long Range Identification and Tracking (LRIT) › Transmission Unit
Issued 19 April 2017
Resolved
Subj. to paragraphs 4.1 & 4.2, this reg. shall apply to the following types of ships engaged on int'l voyages: cargo ships of 300GT (ITC) and upwards. A.494(XII)-ships of 300GT and above engaged on int'l voyages in sea areas A1 & A2 should be required to transmit LRIT info IAW the provisions of reg. V/19-1 as from 31 December 2009. 74 SOLAS (14), Ch. V/19-1.2.1.2, IMO Circular 1295, 5.2.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 5 June 2017
Resolution: Received LRIT Conf Report and Flag Report.
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 23 February 2017
Resolved
01 - 0725 - All fire protection systems and appliances shall at all times be in good order and available for immediate use. Portable fire extinguisher on "muster deck" found with gauge showing "recharge". - CCSSC(2015)3.6.12 - 16bc
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 March 2017
Resolved 9 March 2017
Resolution: Vessel showed recharged extinguisher.
Construction/Loadline › Structures › Door
Issued 23 February 2017
Resolved
02 - 1299 - The strength and construction of hull, superstructures, deck houses, machinery casings, companionways and any other structure shall be sufficient to withstand all foreseeable conditions of the intended service. PSCO observed excessive wastage throughout vessel, including weather tight door from deck to laundry and transverse hull stiffners in way of rudder room. -CCSSC(2015)2.4.1 -16b
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2017
Resolved 30 March 2017
Resolution: MSD St Thomas received attestation form vessel's administration showing reso;ution of deficiency.
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 2 August 2016
Resolved
A foreign Certificate of inspection may be accepted as evidence of lawful inspection. The Certificate of Registry onboard is expired. 46 USC 3303
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2016
Resolved 4 August 2016
Resolution: Received copy of valid Certificate of Registry.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 2 August 2016
Resolved
The fixed fire detection and fire alarm systems of approved type shall be installed in periodically unattended machinery spaces on existing ships. There is no method available to test the operation of the fire detection and alarm system in the engine room. CCSSC 3.17.7
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2016
Resolved 2 August 2016
Resolution: Vessel provided a heat gun to test fire detection system.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 2 August 2016
Resolved
All ships propelled by mechanical means shall be provided with at least two fireman’s outfits. One of the vessel’s two fireman’s outfits is worn, missing patches of outer protective material. CCSSC 3.11.1
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2016
Resolved 4 August 2016
Resolution: Verified purchase and placement on board of new fireman outfit.
Fire Fighting › Firemans Outfit › Axe
Issued 2 August 2016
Resolved
A fireman’s outfit shall consist of personal equipment comprising of an electric safety lamp and an axe. Outfits on board have no means to carry required equipment and hold a fire hose or portable extinguisher (missing outer belt). CCSSC 3.11.2
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2016
Resolved 4 August 2016
Resolution: Verified purchase and placement on board of a belt for each fireman outfit.
Communications › Radio Communications › EPIRB
Issued 2 August 2016
Resolved
EPIRB shall at intervals not exceeding 12 months be inspected and tested inclusive of their source of energy. No evidence of testing or inspection since 2014 is on board CCSSC 5.4
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2016
Resolved 4 August 2016
Resolution: Received report from service technician of a satisfactory inspection/test of the EPIRB.
Operations/Management › Pollution › Control of Garbage
Issued 2 August 2016
Resolved
Every ship over 100GT management plan which includes written procedures for collecting, storing, processing and disposing of garbage. There is no garbage management plan on board. CCSSC7.5.4
Action required: 705 - Other - as specified
Due 17 August 2016
Resolved 22 August 2016
Resolution: Verified documentation to clear deficiency.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 2 August 2016
Resolved
Instructions concerning the maintenance and operating of all equipment and installations on board for fighting and containment of fire shall be readily available in an accessible position. There is not maintenance log on board for fire safety systems. CCSSC3.13
Action required: 705 - Other - as specified
Due 17 August 2016
Resolved 22 August 2016
Resolution: Verified documentation to clear the deficiency.
Construction/Loadline › Markings › Load Line Mark
Issued 2 August 2016
Resolved
The ring lines, and letters shall be painted in white or yellow on a dark background. The vessel’s port side deck line is not a contrasting color. ILLC Annex I Reg 8
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 4 August 2016
Resolution: Verified deck line painted a contrasting color.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 3 April 2016
Resolved
Certificates of competency shall be issued only by the Administrations following verification of the authenticity and validity of any necessary documentary evidence. Master does not have national liceense from St Vincent and Grenadines on board. STCW Reg I/2.1 16c
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 April 2016
Resolved 17 April 2016
Resolution: New captain on board with proper licensing documentation.
Deck/Cargo › Cargo Stowage › General
Issued 15 December 2015
Resolved
Cargo, Cargo units and Cargo transport units shall be loaded, stowed and secured throughout the voyage in accotdance with the cargo securing manual approved by the administration. PSCO observed ship does not posses a cargo securing manual.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 January 2016
Resolved 16 January 2016
Resolution: Vessel recieved Statement of Compliance from PMDS and Interim Certificate for Cargo Securing Manual issued on December 15, 2015 not to exceed 45 days.
Documentation › Manuals/Policy Documentation › Cargo/Ballast System Instruction Manual
Issued 2 December 2015
Resolved
Cargo, cargo units and cargo transport units shall be loaded, stowed and secured throughout the voyage in accordance with the Cargo Securing Manual approved by the Administration. PSCO observed ship does not possess a Cargo Securing Manual.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2015
Resolved 15 December 2015
Operations/Management › Ballast Water Managment › Submission of Report
Issued 2 December 2015
Resolved
The master, owner, operator or person in charge of a vessel subject to this subpart and this section must provide information required by 151.2070 of this subpart in electronic or written form in the Commandment, US Coast Guard or the appropriate COTP. PSCO observed ship was not making the appropriate Ballast [name withheld] reports. 33CFR151.2060.
Condition: Improper/Lack of Maintenance
Due 2 December 2015
Resolved 2 December 2015
Resolution: Master of the vessel demonstrated proper BWM reporting procedures.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 2 December 2015
Resolved
The master, owner, operator or person in charge of a vessel bound for a port or place in the US must ensure the maintenance of written records in respect to Ballast Water Management. PSCO observed records were not being kept for BWM. 33CFR151.2070.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 December 2015
Resolution: PSCO went onboard and inspected ballast water management records and reporting documentation.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 2 December 2015
Resolved
Every ship of 150 gross tonnage and above should be provided with at least one fireman's suit comprised of protective clothing of material to protect the skin from heat. PSCO found the fireman's suit was torn in multiple locations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2015
Resolution: Vessel Mster was able to provide proof of the acquisition of a new Fireman's suit aspproved by Administration.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 2 December 2015
Resolved
A ship where oil fuel is used, the arrangements for the storage distribution and utilization of the oil fuel should be such as to ensure the safety of the ship and persons onboard. PSCO observed several inches of oil/water mixture in the engine room bilge estimated by Chief Engineer at 300 gallons. CCSSC Code 3.19.2.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 December 2015
Resolution: Master has provided proper documentation from Flag attesting to the cleaning of the oil from the vessel's bilge.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 2 December 2015
Resolved
The operator of a vessel with a capacity of 250 or more barrels shall provide transfer procedures that meet the requirements of this part, Part 155, and Part 156 of this Chapter. PSCO noted that vessel did not have oil transfer procedures. 33CFR155.720.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 January 2016
Resolved 15 December 2015
Deck/Cargo › Cargo Stowage › General
Issued 2 December 2015
Resolved
Compressed gas cylinders must always be stowed in a rack in an upright position. PSCO noted three Oxygen cylinders were improperly stowed at the Port side of the cargo deck. 46CFR147.60.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 December 2015
Resolution: PSCO went onboard and observed proper ballast water records and documentation.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 28 July 2015
Resolved
Life saving appliances required by this chapter should comply with the technical specifications of the LSA Code. Unless expressly provided otherwise, all life saving appliances prescribed in this part shall, if they are able to be used in a seaway, be capable of satisfactory operation in that environment. Life jackets found to be in a condition of extreme deterioration.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2015
Resolution: The vessel operator replaced 12 SOLAS approved life jackets.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 28 July 2015
Resolved
The position of the rudder, if power-operated, should be indicated on the navigation bridge. The rudder angle indicator should be independent of steering control system. Rudder angle indication on navigation bridge only indicated rudder angle when bridge controls were exercised. Rudder angle not indicated on bridge when controlled from engine room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2015
Resolution: The vessel operator repaired the rudder angle indicator.
Construction/Loadline › Structures › Door
Issued 28 July 2015
Resolved
The strength and condition of hull, superstructures, deckhouses, machinery casings, companionways, and other structure and equipment should be sufficient to withstand all foreseeable conditions of intended service. 01 deck of superstructure, aft weathertight door frame has gaps in welding and knife edge that allows water intrusion. (CCSS Code 2.4.1)
Condition: Improper/Lack of Maintenance
Due 27 August 2015
Resolved 26 August 2015
Resolution: Aft weather tight door frame has gaps in welding and knife edge that allows water intrusion - crew replace door and it is now weather tight.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 3 June 2014
Resolved
The Master and Chief Mate did not have a valid endorsement and have not provided proof that an application for an endorsement has been submitted to the administration. STCW 95 I/4. To the satisfaction of the certificate issuing authority and the Coast Guard.
Action required: 705 - Other - as specified
Resolved 15 July 2014
Resolution: Vesssel recieved a new Master and Chief Mate
Construction/Loadline › Structures › Deck Plating
Issued 3 June 2014
Resolved
The entire stern ramp was found to be severely corroded and plagued with broken welds. The starboard most hinge point on the stern ramp was broken and several hinge pins were missing their locking mechanism. CCSS CODE Part B Chapter 1.11. To the satisfaction of the certificate issuing authority and the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 July 2014
Resolution: Received attestation letter from Flag confirming that the ramp was completely rebuilt using new materials and that the ramp and hydraulic winch were lift tested to the satisfaction of the PMDS surveyor.
Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 3 June 2014
Resolved
The Chief Mate did not have a national license. The vessel is not currently compliant with their safe manning document. STCW 95 I/4. To the satisfaction of the certificate issuing authority and the Coast Guard.
Action required: 705 - Other - as specified
Resolved 15 July 2014
Resolution: Vessel recieved a new Chief Mate.
Lifesaving › Rigid Liferafts › Hydrostatic Release Unit
Issued 17 July 2012
Resolved
0699- Life-saving appliances shall be in working order and ready for immediate use. hydrostatic release unit is painted over top and side warnng "do not paint" label.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2012
Resolution: Ship''s crew requisitioned new hydrostatic release unit and installed prior to PSCO departure.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 July 2012
Resolved
1460- CCSSC chapter 2.12.6. Moving parts of machinery which are exposed as to cause accidents should be properly guarded. PSCO found the oily bilge pump and auxiliary diesel oil transfer pump without safety guard on shaft/coupling area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 July 2012
Resolved 18 July 2012
Resolution: Crew installed safety guards on oily bilge pump and auxiliary diesel oil transfer pump.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 July 2012
Resolved
1460- CCSSC chapter 2.12.6. Moving parts of machinery which are exposed as to cause accidents should be properly guarded. PSCO found #2 Ship's service diesel generator running without safety guard (prime mover end coupling)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 17 July 2012
Resolution: safety guard was removed and placed on working bench, crew re-installed safety guard on generator.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 22 June 2012
Resolved
Vessel is required to maintain fire detection systems. Three fire sensors in the engine room failed to activate.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 June 2012
Resolved 26 June 2012
Resolution: Vessel''s Administration provided documentation clearing deficiencies.
Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 13 December 2011
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 December 2011
Resolution: 29DEC2011 Vessel provided proper documentation satisfying the MSM Document.
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 13 December 2011
Resolved
The capacity of required portable carbon dioxide fire extinguishers should not be less than 3 KG. Fire extinguisher on aft deck, port side was found depleted. CCSS Code CH 3 Part A Reg 3.6.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 January 2012
Resolution: Vessel has replaced depleted fire extinguisher with a new one.
Engineering › Generator (propulsion-electric) › Cable
Issued 13 December 2011
Resolved
All machinery instalations and associated piping systems should be of design and construction to reduce to a minimum any danger. Improper insulation found on exhaust pipe on #1 generator. CCSS Code CH II Part A Reg 2.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 January 2012
Resolution: vessel has replaced wasted insulation with new insulation.
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 13 December 2011
Resolved
Vessels 300GT and above must submit a notice of intent to EPA for a Vessel General Permit. Vessel has not submitted notice of intent to EPA.
[name withheld] L Carvalho
[phone withheld]
Action required: 705 - Other - as specified
Due 13 December 2011
Resolved 13 December 2011
Resolution: Vessel was notified of requirements of VGP; Corrected on spot - 10c
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 25 January 2011
Resolved
Steering gear pump No.1 wheel house transfer solenoid and does not allow for bridge control. Pump No.2 can be effectively controlled from the bridge, but in order to use pump No.1 as an auxiliary means of steering, control has to be taken from the engine room.
Action required: 705 - Other - as specified
Due 4 February 2011
Resolved 4 February 2011
Resolution: Team visited vessel to clear deficiency. Conducted steering tests on both pumps from the bridge and the engine room. All systems worked properly. Agency action complete.
Lifesaving › Buoyant Apparatus › Float Free
Issued 25 January 2011
Resolved
EPIRB shall be capable of floating free if the vessel sinks. Vessel's EPIRB has an expired hydrostatic release.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2011
Resolution: New hydrostatic release was purchased and installed for the EPIRB
Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 28 October 2010
Resolved
Vessel crew is to meet the manning document onboard. The Chief Mate has proper endorsement but his National License was not present. Chief is to have his license on board prior to departing port.
Code: 0220
Cite: CCSSC Chap1 part A 1.7
Action: 17(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 November 2010
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 28 October 2010
Resolved
Under the sewage holding tank forward of the corridor under the ladder, there is excessive wastage of the deck. This is unsafe condition for the crew and vessel. Replace/ Repair the wasted area under the MSD.
Code: 1499
Cite: CCSSC Chap 1 part B 1.11.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 November 2010
Resolved 1 November 2010
Resolution: Coast Guard Inspector verified the replacing of the deck under the MSD, deficiency removed.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 2 March 2010
Resolved
0299- Vessel's officer in charge of engineering watch (second engineer) as per Minimum Safe Manning does not a Dominica flag endorsement to national license nor a valid application on file. Vessel shall provide a valid flag endorsement for engineering officer prior to departure. STCW 95 I/4.1.1 CCSS code CH1 PART 4 REG. 1.7.1
Action required: 17 - Rectify deficiencies prior to departure
Due 2 March 2010
Resolved 12 March 2010
Resolution: Second Engineer recieved the flag endorsement.
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 2 March 2010
Resolved
0940-Starboard storage tank for fuel is leaking due to a fracture of approximately 2 feet on bottom weld seem leading to passageway tunnel. Vessel shall repair leak to satisfaction of the administration prior to departure, in order to avoid fire hazard. CCSS code CH.1 Part B Reg 1.11
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 2 March 2010
Resolved 12 March 2010
Resolution: Vessel conducted welding to repair leaking tank seam. Flag reviewed and approved repairs, Coast Guard confirmed no further visible leaking.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 2 March 2010
Resolved
1499-While conducting engine room exam PSCO observed a fuel leak from vessel's auxiliary diesel oil transfer pump. fuel leak was being contained with a bucket at the time. Vessel shall repair fuel leak to the satisfaction of the administration prior to departure, to avoid fire hazard. CCSS code CH.1 Part B Reg. 1.11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 March 2010
Resolved 12 March 2010
Resolution: Vessel repaired diesel transfer pump. Flag confirmed acceptable repairs made and Coast Guard confirmed no further visible fuel leak.
Electrical › Electric Generation Source (emergency) › Generator
Issued 2 March 2010
Resolved
1430-Vessel's emergency generator is inoperable due to broken starting pull cord. Vessel shall repair equipment prior to departure. CCSS code ch.2 Part B Reg. 2.29.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 March 2010
Resolved 12 March 2010
Resolution: Vessel replaced old generator with new generator. Flag confirmed new generator meets vessel requirements and Coast Guard confirmed operation of the generator.
Engineering › Steering Gear System › Ram Seal
Issued 2 March 2010
Resolved
1499-While conducting steering gear test, observed significant hydraulic leaks on Port & Stbd ram seals. Vessel shall repair to the satisfaction of administration prior to departure. CCSSC code CH.1 Part b Reg.1.11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 March 2010
Resolved 12 March 2010
Resolution: Vessel sent rams out for repairs and flag approved repairs that were made. [name withheld] confirmed that there is no longer substantial leaking from the hydraulic rams.
Navigation › Collision/Grounding Avoidance › Radar
Issued 2 March 2010
Resolved
Vessel's 9GHz Radar is inoperable. Vessel shall repair or replace and provide a certified technician report to satisfaction of Coast Guard prior to departure. CCSS code CH.6.1, 6.2
Action required: 17 - Rectify deficiencies prior to departure
Due 2 March 2010
Resolved 12 March 2010
Resolution: Vessel had a technical repair service conduct repairs to the radar. Flag and Coast Guard confirm tech report recieved verifiying the repair of the radar.
Fire Fighting › Remote Fuel Shutoff › General
Issued 2 March 2010
Resolved
0710-Starboard main emergency fuel shutoff valve is not functioning, preventing crew to shutoff main engine in case of an emergency. Vessel shall repair to satisfaction of administration prior to departure. CCSS Code CH.2 Part D Reg 2.20
Action required: 17 - Rectify deficiencies prior to departure
Due 2 March 2010
Resolved 12 March 2010
Resolution: Vessel conducted repairs reinstalling and repairing remote shutoffs for the Starboard main. Flag confirmed repairs were conducted satisfactorially. Coast Guard confirmed installation of remote shutoff.
Stability › Watertight Integrity › General
Issued 2 March 2010
Resolved
0910-Gasket on watertight door leading from main deck to engine room is deteriorated, therefore compromising watertight integrity of vessel. Vessel shall replace to satisfaction of administration. CCSS code CH.2 Part B Reg. 2.7.4
Action required: 705 - Other - as specified
Due 16 March 2010
Resolved 12 March 2010
Resolution: Vessel replaced deteriorated gaskets on water tight doors. Flag and Coast Guard confirmed the integrity of the water tight doors.
Electrical › Electric Generation Source (service) › Switch
Issued 2 March 2010
Resolved
1060-Alarm panel in engine room is inoperable, therefore preventing proper indication of machinery failures. Vessel shall repair to satisfaction of administration. CCSS code CH.2 Part D Reg.2.19.6
Action required: 705 - Other - as specified
Due 24 March 2010
Resolved 28 October 2010
Resolution: Alarm panel worked properly during inspection.
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 2 March 2010
Resolved
While reviewing vessel documentation, found one missing entry of vessel's dry dock date on the Caribbean Cargo Ship Safety Certificate. Vessel's administration shall provide clarification on vessel's dry dock date prior to vessel's last dry dock inspection conducted on 8 September 2008. CCSS code CH.1 Part B Reg. 1.10
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 12 March 2010
Resolution: Flag corrected docuemts and provided Coast Guard with letter of explanation as to the dry dock discrepancy. Flag had not attended dry dock due to inclamate weather but was accepting the dry dock report from the dry dock.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 2 December 2009
Resolved
Lifering on starboard side of main deck needs new reflective tape.
Action required: 705 - Other - as specified
Due 1 January 2010
Resolved 3 January 2010
Resolution: Found retro tape to be renewed and satisfactory.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 2 December 2009
Resolved
CO2 bottle located at entry of starboard side ladder well to engine room is not properly secured.
Action required: 705 - Other - as specified
Due 1 January 2010
Resolved 3 January 2010
Resolution: CO2 bottle was found to be securely fastened to bulkhead with a proper clamp.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 2 December 2009
Resolved
Fire extinguisher located at bottom of starboard side ladder well to engine room not properly secured.
Action required: 705 - Other - as specified
Due 1 January 2010
Resolved 5 January 2010
Resolution: Vessel purchased and installed new fire extinguisher bracket.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 December 2009
Resolved
Light cover above starboard side main engine is broken. All electrical installations should be of adequate construction for the service in which they are intended.
Action required: 705 - Other - as specified
Due 1 January 2010
Resolved 3 January 2010
Resolution: Light cover was secured to the fixture.
Electrical › Electric Generation Source (service) › Generator
Issued 13 July 2008
Resolved
Port Generator leaking oil from the head area. Repair oil leak on Port Generator to the satisfaction of the administration.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 July 2008
Resolved 17 September 2008
Resolution: Recieved Administration report attesting to proper repairs.
Electrical › Electric Generation Source (service) › Generator
Issued 13 July 2008
Resolved
Starboard Generator has a bad piston ring in one cylinder. Repair Starboard Generator to the satisfaction of the administration.
Action required: 705 - Other - as specified
Due 17 July 2008
Resolved 14 July 2008
Resolution: Received report from administration rectifying starboard generator.
Electrical › Electric Generation Source (service) › Generator
Issued 25 June 2008
Resolved
FOUND PORT GENERATOR LEAKING OIL FROM THE HEAD AREA. REPAIR OIL LEAK ON PORT GENERATOR TO THE SATISFACTION OF THE ADMINISTRATION.
Action required: 705 - Other - as specified
Due 9 July 2008
Resolved 17 September 2008
Resolution: Recieved Administration report attesting to proper repairs.
Electrical › Electric Generation Source (service) › Generator
Issued 25 June 2008
Resolved
CHIEF ENGINEER REPORTED THAT THE STARBOARD GENERATOR HAD BAD PISTON RINGS IN ONE CYLINDER. REPAIR STARBOARD GENERATOR TO THE SATISFACTION OF THE ADMINISTRATION.
Action required: 705 - Other - as specified
Due 9 July 2008
Resolved 14 July 2008
Resolution: Received report from administration rectifying starboard generator.
Construction/Loadline › Structures › Superstructure
Issued 20 February 2008
Resolved
Cargo loading ramp is wasted and welds are failing. Repair/replace loading ramp to the satisfaction of flag administration. Provide flag report to the United States Coast Guard.
Flag/admin has aproved extension for repair date to 13MAR08.
Action required: 705 - Other - as specified
Due 13 March 2008
Resolved 18 April 2008
Resolution: Received Flag Administration report confirming the new loading ramp has been installed.
Documentation › Certificates/Documents › Stability Letter
Issued 18 October 2006
Resolved
Provide evidence that vessel crew are trained and able to meet the requirements of the stability booklet approval. To be completed to the satisfaction of Coast Guard Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2006
Resolution: Captain and crew provided sufficient evidence that they were familiar with the stability book.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 18 October 2006
Resolved
Engine room classed unmanned (see CCSS supplement 1.6)). Provide evidence of approval for detectors (see CCSS supplement 3.4) as approved by CCSSC 3.16.7 and of satisfactory condition as required by CCSSC 1.11. Until corrected main engine room with adequate fire watch. To be completed to the satisfaction of class.
Action required: 705 - Other - as specified
Due 1 December 2006
Resolved 10 December 2006
Navigation › Piloting/Steering › US Coast Pilot
Issued 18 October 2006
Resolved
Provide current Coast Pilot to the satisfaction of Coast Guard.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 October 2006
Resolution: Received invoice for current Coast Pilot.
Engineering › Steering Gear System › Piping
Issued 18 October 2006
Resolved
Hydraulic steering pipe in the shaft alley to steering lazarette is holed. Make repairs to pipe (see soft patch). To the satisfaction oF Class.
Action required: 705 - Other - as specified
Due 24 November 2006
Resolved 26 October 2006
Resolution: Repairs made to the satisfaction of Flag.
Fire Fighting › Fire Main › Pressure
Issued 18 October 2006
Resolved
Make repairs to bridge fire pump gauge and indicators-for indicators see CCSSC 2.32.1.8. To be completed to the satisfaction of class.
Action required: 15 - Rectify deficiencies by next port
Due 24 November 2006
Resolved 24 December 2006
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 18 October 2006
Resolved
Provide current deviation table IAW CCSSC 6.4.2. To be completed to the satisfaction of Class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 October 2006
Resolution: Evidence provided by Flag
Electrical › Lighting (service) › Switch
Issued 22 March 2006
Resolved
Vessel had replace two light covers in one of the crew cabins. In addition, electrical wires dead ended were found in a bath room space.
Action required: 705 - Other - as specified
Due 22 March 2006
Resolved 22 March 2006
Resolution: Vessel corrected deficiencies prior departure.
Construction/Loadline › Structures › Door
Issued 22 March 2006
Resolved
Wasted loading ramp. Vessel to conduct proper repairs and submit Flag Administration report attesting proper repairs to OCMI within sixty day (During dry dock period). Item to be resolved to the satisfaction of Flag administration during dry dock period.
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 15 June 2006
Resolution: Vessel repaired loading ramp
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 22 March 2006
Resolved
While conducting document checks, noticed CCSSC certificate was not properly endorsed by Flag Administration.
Action required: 705 - Other - as specified
Due 22 March 2006
Resolved 22 March 2006
Resolution: Flag Administration to properly endorsed CCSSC certificate prior departure.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 22 March 2006
Resolved
While conducting PSC Exam, discovered faulty smoke detector in the crew recreational room.
Action required: 705 - Other - as specified
Due 22 March 2006
Resolved 22 March 2006
Resolution: Vessel provided evidence of proper installation of a new smoke detector in the crew recreational room prior departure.
Construction/Loadline › Hull › Transverse Frame
Issued 22 March 2006
Resolved
Major setting STBD side amid ship. Tripped frame and bulkhead. Item to be resolved to the satisfaction of Flag administration during dry dock period.
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 15 June 2006
Resolution: Vessel replaced side shell in yard in DR
Operations/Management › Log/Records › Ballast Water Logs/Records
Issued 22 March 2006
Resolved
All ships logs need to be updated. Item to be resolved to the satisfaction of the OCMI within fourteen days from the date of this exam.
Action required: 705 - Other - as specified
Due 4 April 2006
Resolved 4 April 2006
Resolution: All ships logs are currently updated.
Engineering › Fuel Oil Service System › Ventilation
Issued 22 March 2006
Resolved
Fuel oil balls missing in engine room 0303. Item to be resolved to the satisfaction of the OCMI within fourteen days from the date of this exam.
Action required: 705 - Other - as specified
Due 4 April 2006
Resolved 4 April 2006
Resolution: Check for missing items in the engine room. Deficiency resolved.
Construction/Loadline › Structures › Door
Issued 22 March 2006
Resolved
Replace wasted WTD STBD side engine room entrance. Remove paint from knife edge both Port and STBD side. Item to be resolved to the satisfaction of Flag administration during dry dock period.
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 15 June 2006
Resolution: Vessel replaced both engine room entrance WTD during yard
Fire Fighting › Ventilation Systems › Ducts
Issued 22 March 2006
Resolved
Various flame screens missing in fuel oil goose necks on main decks and ballast tank goose necks. Item to be resolved to the satisfaction of Flag administration during dry dock period.
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 15 June 2006
Resolution: Vessel replaced during yard
Operations/Management › Ballast Water Managment › Ballast Retention
Issued 22 March 2006
Resolved
Various ballast tank check valves for goose neck wasted. Item to be resolved to the satisfaction of Flag administration during dry dock period.
Due 31 May 2006
Resolved 15 June 2006
Resolution: Vessel repaired during yard
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 22 March 2006
Resolved
Fuel oil containment missing mechanical plugs. Item to be resolved to the satisfaction of Flag administration during dry dock period.
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 15 June 2006
Resolution: Vessel repaired during yard
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 22 March 2006
Resolved
Inoperative fire damper port side found wasted. Item to be resolved to the satisfaction of Flag administration during dry dock period.
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 15 June 2006
Resolution: Vessel repaired during yard
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 20 January 2006
Resolved
Vessel crew did not have a Officer of the Nav. Watch per the safe manning cert. Flag State updated the safe manning cert. to exclude the Officer of the Nav. Watch and replace it with a Chief mate.
Action required: 705 - Other - as specified
Resolved 26 January 2006
Resolution: Vessel was found in complience this date with the Safe manning cert.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 19 January 2006
Resolved
Provide all required personnel as stated on Safe Manning Certificate (SMC) with flag state endorsement or licenses prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2006
Resolution: Vessel granted one time exemption from flag state to sail from St. Croix to Puerto Rico.
Construction/Loadline › Hull › Bracket
Issued 1 March 2005
Resolved
Replace wasted bracket in steering gear room portside first frame from forward blk connecting the deck transverse and frame.
Due 1 April 2005
Resolved 19 March 2005
Construction/Loadline › Hull › Transverse Frame
Issued 1 March 2005
Resolved
Replace 2nd overhead transverse from 1/2 way the compartment to stbd side were wasted.
Due 1 April 2005
Resolved 19 March 2005
Construction/Loadline › Hull › Transverse Frame
Issued 1 March 2005
Resolved
Crop and renew #1, #2 stbd side deck transverse were holed and replace respective brackets.
Due 1 April 2005
Resolved 19 March 2005
Construction/Loadline › Hull › Bracket
Issued 1 March 2005
Resolved
Replace steering gear base bracket were holed.
Due 1 April 2005
Resolved 19 March 2005
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 1 March 2005
Resolved
Install angle indicator at manual steering control station.
Due 1 April 2005
Resolved 19 March 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 1 March 2005
Resolved
Remove mud compressor from engine room.
Due 1 April 2005
Resolved 19 March 2005
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 1 March 2005
Resolved
Empty bilges.
Due 16 March 2005
Resolved 19 March 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 March 2005
Resolved
Replace connectors and fittings for the oil pressure sensor starboard side engine.
Due 16 March 2005
Resolved 19 March 2005
Engineering › Diesel Engine (propulsion-direct drive) › Silencer (exhaust)
Issued 1 March 2005
Resolved
Replace exhaust insulation on portside engine iwo stairway.
Due 16 March 2005
Resolved 19 March 2005
Electrical › Electrical Distribution System (emergency) › Switchboard
Issued 1 March 2005
Resolved
Replace port side generator indicator lamp and cover on switchboard.
Due 16 March 2005
Resolved 19 March 2005
Stability › Watertight Integrity › General
Issued 1 March 2005
Resolved
Fix tip of gooseneck ballast vent iwo stbd side first from loading ramp.
Due 1 April 2005
Resolved 19 March 2005
Construction/Loadline › Structures › Machinery Space Opening
Issued 1 March 2005
Resolved
Replace starboard side ladder leading to bridge.
Due 1 April 2005
Resolved 19 March 2005
Lifesaving › Rescue Boat › Carriage Requirement
Issued 1 March 2005
Resolved
Replace rescue boat.
Due 16 March 2005
Resolved 19 March 2005
Engineering › Generator (propulsion-electric) › Contactor Circuitry
Issued 16 December 2004
Resolved
Overspeed for starboard main generator has been disconnected. Provide operational overspeed to satifaction of the certificate issuing authoritybut no later than 30DEC2004. Until the overspeed device is repaired as orginal the starboard generator is not to be used.
Action required: 705 - Other - as specified
Due 30 December 2004
Resolved 30 December 2004
Resolution: Marine Inspector, [name withheld], witnessed satisfactory operational test of overspeed for starboard main generator.
Lifesaving › Inflatable Liferafts › Float Free
Issued 3 December 2004
Resolved
Liferafts are secured to deck with line and not equipped with hydrostatic releases that would allow float free operation.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2004
Resolution: Vessel owner provided 2 hydrostatic releases.
Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 19 November 2004
Resolved
Chief mate must provide original license prior to next US port.
Action required: 15 - Rectify deficiencies by next port
Resolved 3 December 2004
Resolution: License produced.
Construction/Loadline › Hull › Transverse Frame
Issued 19 November 2004
Resolved
Repair holes in cargo deck to the satisfaction of flag state representative prior to the carriage of any additional cargo.
Action required: 705 - Other - as specified
Resolved 3 December 2004
Resolution: Flag report attesting to satisfactory repairs recieved.
Deck/Cargo › Ballast › Piping
Issued 19 November 2004
Resolved
Replace temporary repairs on piping between #3 port and starboard ballast tanks with permanent repairs to the satisfaction of flag state representative prior to 19DEC04.
Action required: 705 - Other - as specified
Due 19 December 2004
Resolved 3 December 2004
Resolution: Piping replaced to satisfaction of flag state representative.
Stability › Watertight Integrity › Coaming
Issued 19 November 2004
Resolved
Repair knife dedges on watertight doors on both exterior engine room doors, door from galley to cargo deck, and door from lower deck to exterior prior to 19DEC04.
Action required: 705 - Other - as specified
Due 19 December 2004
Resolved 3 December 2004
Resolution: Piping replaced to satisfaction of flag state representative.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 19 November 2004
Resolved
Make permanent repairs to hole in #1 starboard diesel tank to the satisfaction of flag state representative prior to 19DEC04.
Action required: 705 - Other - as specified
Due 19 December 2004
Resolved 3 December 2004
Resolution: Piping replaced to satisfaction of flag state representative.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 19 November 2004
Resolved
Install echo depth sounder as required by CCSSC certificate prior to departure from San Juan, PR to the satisfaction of the attending Coast Guard inspector or flag state representative.
Action required: 705 - Other - as specified
Resolved 3 December 2004
Resolution: flag state representative deleted requirement for vessel to have echo depth sounder.
Navigation › Piloting/Steering › Marine Charts
Issued 19 November 2004
Resolved
Provide currently corrected charts and current Coast Pilot prior to departure departure from San Juan, PR to the satisfaction of the attending Coast Guard inspector.
Action required: 705 - Other - as specified
Resolved 3 December 2004
Resolution: Currently corrected chart and coast pilot provided.
Documentation › Certificates/Documents › Special Purpose Ship Safety Certificate
Issued 19 November 2004
Resolved
Update CCSSC certificate to reflect actual liferaft capacity on board or provide two 10 person capacity liferafts as stated on the CCSSC certificate. Correct to the satisfaction of flag state representative.
Action required: 705 - Other - as specified
Resolved 3 December 2004
Resolution: Flag state representative approved temporary replacement with two 15 man liferafts.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 19 November 2004
Resolved
Ensure fire flaps to engine room are not blocked by cargo regardless of loading condition and can be closed in case of an engine room fire.
Action required: 705 - Other - as specified
Resolved 3 December 2004
Resolution: Requirement is redundant as stabilty booklet requires flaps to remain clear at all times.
Construction/Loadline › Hull › Hull Plating
Issued 15 August 2004
Resolved
Vessel to permanently repair all hull damage associated with allision. Flag State representative to provide a report attesting to satisfactory repairs and seaworthiness of vessel. This requirement is also issued during PSC Re-Exam conducted 17 August 2004.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2004
Resolution: Received Dominica report attesting to proper repair of hull.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 15 August 2004
Resolved
Vessel to repair/replace faulty cylinder that relays commands from the bridge to the starboard engine. Flag State representative to provide a report attesting to proper repairs and operation of the starboard engine.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2004
Resolution: Rreceived require report
Lifesaving › Inflatable Liferafts
Issued 24 February 2004
Resolved
Replace portside liferaft prior to departure. Fax invoice copy to cognizant Marine Safety Office or [name withheld]: Main Buoyancy Chamber
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 24 February 2004
Resolved 25 February 2004
Resolution: Received Master''s Statement, Invoice and Liferaft''s Certificate of Inspection for the purchase of new Portside liferaft. Vessel cleared to depart.
Engineering › Fuel Oil Storage/Transfer System
Issued 24 February 2004
Resolved
Vessel to conduct static liquid pressure test of bunkering pipe system in accordance with 33CFR156.170. Flag Administration to attest results of testing and submit survey report to cognizant MSO or OCMI prior to 24 March 2004. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 24 March 2004
Resolved 9 March 2004
Resolution: Recieved masters statement confirming test results.
Pollution Prevention/Response › Prevention Equipment
Issued 24 February 2004
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 March 2004
Resolved 18 March 2004
Resolution: Received receipt of standard discharge connection. Discrepancy corrected.
Stability › Watertight Integrity
Issued 26 November 2003
Resolved
Vessel grounded. Flag/Class to provide report attesting to hull's watertight inegrity.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2003
Resolved 4 December 2003
Resolution: Received Flag/Class report attesting to the hull''s watertight integrity
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 4 November 2003
Resolved
Provide right mannin level in accordance with the Safe Manning Certificate, Vsl master and Chief Mate.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 November 2003
Resolved 9 November 2003
Personnel › Manning/Qualifications
Issued 4 November 2003
Resolved
Master and mate found intoxicated while inport preparing for departure. COTP order issued, vsl detained in port until crew replaced with qualified pers. LEGACY COMPONENT DESC: Medical Fitness
Action required: 17 - Rectify deficiencies prior to departure
Due 4 November 2003
Resolved 14 November 2003
Resolution: Vsl reflagged and crew replaced.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 12 August 2003
Resolved
VESSEL TO REPLACE/RENEW FLAME SCREEN ON STBD FUEL VENT, LOCATED IN CONTAINMENT BIN OF MAINDECK. LEGACY COMPONENT DESC: Flame Screens
Due 12 September 2003
Resolved 27 August 2003
Resolution: RECEIVED FAX OF REPAIRS/RENEWALS FROM MARINE SURVEYOR.
Documentation › Certificates/Documents
Issued 12 August 2003
Resolved
VESSEL FLAG STATE TO UPDATE CCSSC TO INDICATE REQUIRED FIREMAN'S EQUIPMENT (SECTION 3.2.7 OF CCSSC CODE).
Due 12 September 2003
Resolved 27 August 2003
Resolution: RECEIVED FAX OF REPAIRS/RENEWALS/UPDATES FROM MARINE SURVEYOR.
Lifesaving › Lifebuoys
Issued 12 August 2003
Resolved
VESSEL TO REPLACE/RENEW LIGHT TO LIFEBOUY ON PORTSIDE OF DECKHOUSE. LEGACY COMPONENT DESC: Self-igniting Lights
Due 12 September 2003
Resolved 27 August 2003
Resolution: RECEIVED FAX OF REPAIRS/RENEWALS FROM MARINE SURVEYOR.
Lifesaving › Inflatable Liferafts
Issued 12 August 2003
Resolved
VESSEL TO UPDATE INSPECTION STICKER ON PORTSIDE LIFERAFT. VESSEL SHOWED PROOF OF INSPECTION. LEGACY COMPONENT DESC: Markings
Due 12 September 2003
Resolved 27 August 2003
Resolution: RECEIVED FAX OF REPAIRS/RENEWALS FROM MARINE SURVEYOR.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 18 June 2003
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2003
Resolved 23 June 2003
Documentation › Manuals/Policy Documentation
Issued 26 February 2003
Resolved
Provide instructions for maintenance and operation of al installations equipments for firghting and containment for fire IAW CCSSC 3.13.3, prior to 26MAR03. LEGACY COMPONENT DESC: Instructions for On-board Maintenance (firefighting)
Action required: 705 - Other - as specified
Due 26 March 2003
Resolved 24 March 2003
Resolution: Instructions provided
Operations/Management › Drills/Instruction
Issued 26 February 2003
Resolved
Update emergency instructions to reflect current procedures and crew IAW CCSSC 4.16, prior to 26MAR03. LEGACY COMPONENT DESC: Emergency Instructions
Action required: 705 - Other - as specified
Due 26 March 2003
Resolved 24 March 2003
Resolution: Instructions updated
Fire Fighting › Firemans Outfit
Issued 21 February 2003
Resolved
Provide fireproof lifeline of sufficient length and strength IAW CCSSC 3.11.3, prior to departure. LEGACY COMPONENT DESC: Lifeline
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2003
Resolved 27 March 2003
Resolution: Received fax from [name withheld] surveyor attesting to the purchase.
Fire Fighting › Self-contained Breathing Apparatus
Issued 21 February 2003
Resolved
Provide spare air bottle and recharge main air bottle to the breathing apparatus IAW CCSSC 3.11.2.2, prior to departure. LEGACY COMPONENT DESC: Air Bottle
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2003
Resolved 27 February 2003
Resolution: Received fax from suveryor attesting to completion.
Lifesaving › Rescue Boat
Issued 21 February 2003
Resolved
Have Class/Flag address rescue boat capacity. CCSSC certificate indicated rescue boat was rated for 6 persons, while vessel's marking plate states 3 persons max.prior to departure. LEGACY COMPONENT DESC: Capacity
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2003
Resolved 27 February 2003
Resolution: Surveyor made correction to certificate indicating 3 person max.
Lifesaving › Rescue Boat
Issued 21 February 2003
Resolved
Mark rescue boat IAW LSA code 4.4.9, prior to 26MAR03. LEGACY COMPONENT DESC: Markings
Action required: 705 - Other - as specified
Due 26 March 2003
Resolved 24 March 2003
Resolution: Rescue boat marked
Lifesaving › Rescue Boat Equipment
Issued 21 February 2003
Resolved
Provide all required rescue boat equipment IAW LSA 5.1.2, prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2003
Resolved 27 February 2003
Resolution: Surveyor attested to completion.
Personnel › Certificates/Documents/Licenses
Issued 21 February 2003
Resolved
Ensure all crew members on board are examined by a qualified physician and provide medical certificate attesting to their fitness for work on board IAW ILO 147, prior to departure. LEGACY COMPONENT DESC: Medical Fitness Document
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2003
Resolved 27 February 2003
Resolution: Surveyor attested to completion.
Construction/Loadline
Issued 21 February 2003
Resolved
Have Class/Flag address requirement of drydock. Vessel has exceeded 3 year interval between previous drydocking (7months overdue). Last drydocking dates JUN97 & JUL00. Have vessel drydocked, prior to taking on cargo in U.S. LEGACY COMPONENT DESC: Drydocking
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 February 2003
Resolved 24 March 2003
Resolution: Drydock was conducted march 9-22, 2003
Operations/Management › Drills/Instruction
Issued 21 February 2003
Resolved
Conduct satisfactory fire drill int he presence of a marine surveyor, prior to departure. LEGACY COMPONENT DESC: Fire
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2003
Resolved 27 February 2003
Resolution: Surveyor attested to the satisfactory witnessing of fir drill.
Construction/Loadline › Markings
Issued 21 February 2003
Resolved
Mark deck line IAW ILL Reg 8 prior to 26MAR03. LEGACY COMPONENT DESC: Deck Line
Action required: 705 - Other - as specified
Due 26 March 2003
Resolved 24 March 2003
Resolution: Deck line marked
Pollution Prevention/Response › Prevention Equipment
Issued 21 February 2003
Resolved
Provide/Install pump and oily mixture discharge fixed piping system with at least one outlet accessible from deck to meet specifications (standard discharge connection) IAW 33 CFR 155.430 & 33 CFR 155.420 by 26MAR03. LEGACY COMPONENT DESC: Oily Mixture Discharge Fixed Piping System
Action required: 705 - Other - as specified
Due 26 March 2003
Resolved 24 March 2003
Resolution: Pump and oily mixture disharge fixed piping system was installed.
Equipment was installed during drydock.
Accommodation/Occupational Safety › Occupational Safety
Issued 22 May 2002
Resolved
Provide cover for light fixture located in steering gear space. LEGACY COMPONENT DESC: Spark Producing Device
Condition: Unknown
Due 15 July 2002
Resolved 29 July 2002
Resolution: Viewed new light cover
Lifesaving › Lifejacket/PFD (General)
Issued 22 May 2002
Resolved
Renew/replace retroreflective tape on all lifejackets. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Due 15 July 2002
Resolved 29 July 2002
Resolution: viewed new retro on lifejacets
Communications › Automatic Identification System (AIS)
Issued 22 May 2002
Resolved
Replace search & rescue transponder (SART) battery LEGACY COMPONENT DESC: Marine band Non-Directional Beacon Receiver
Condition: Unknown
Due 15 July 2002
Resolved 29 July 2002
Resolution: Viewed complete new SART
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 22 May 2002
Resolved
Provide brackets for all loose fire extinguishers. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Unknown
Due 15 July 2002
Resolved 29 July 2002
Resolution: Inspected new fire extinquisher brackets
Operations/Management › Navigation Safety
Issued 22 May 2002
Resolved
Provide new/updated light list & coast pilot. LEGACY COMPONENT DESC: Carriage of Charts and Publications
Condition: Unknown
Due 15 July 2002
Resolved 29 July 2002
Resolution: Viewed new Coast Pilot and Light List
Fire Fighting › Fire Main
Issued 22 May 2002
Resolved
Repair/replace gauge located on fire main pump. LEGACY COMPONENT DESC: Valves
Condition: Unknown
Due 15 July 2002
Resolved 29 July 2002
Resolution: Viewed new gauge on fire main discharge.
Electrical
Issued 10 April 2001
Resolved
PROVIDE LIGHT EXPLOSION PROOF FIXTURE FOR THE STANDARD SIDE LIGHT AT THE STEERING COMPARTMEMT. REGULATION 2.32 CCSSC CODE
Condition: Unknown
Due 10 May 2001
Resolved 21 May 2001
Fire Fighting
Issued 10 April 2001
Resolved
PROVIDE A RIGID HELMET (FIREMAN HELMET) IAW 3.11.2.1.3 OF THE CCSSC CODE.
Condition: Unknown
Due 10 May 2001
Resolved 21 May 2001
Fire Fighting
Issued 10 April 2001
Resolved
PROVIDE AN ELECTRIC SAFETY LAMP (HAND LANTERN) OF AN APPROVED TYPE WITH A MINIMUN BURNING PERIOD OF THREE HOURS FOR THE FIREMAN OUTFIT. REGULATION 3.11.2.1.4 OF THE CCSSC CODE.
Condition: Unknown
Due 10 May 2001
Resolved 21 May 2001
Engineering
Issued 10 April 2001
Resolved
PROVIDE OIL TRANSFER PROCEDURES IAW REGULATION UNDER 33 CFR PART 155.
Condition: Unknown
Due 10 May 2001
Resolved 21 May 2001
Navigation
Issued 10 April 2001
Resolved
REPLACED 10" BELL. VESSEL IS REQUIRED TO HAVE A 10" BELL IAW CCSSC CERTIFICATE. EXISTING BELL DOES NOT PROVIDE ADECUATE SOUND. REGULATION 1.10.2.3 AND 1972 COLREGS.
Condition: Unknown
Due 10 May 2001
Resolved 21 May 2001
Electrical
Issued 10 April 2001
Resolved
REPAIR SOLENOID VALVE WIRING FOR SHIP WHISTLE. REGULATION 2.32 CCSSC_x001C_ CODE.
Condition: Unknown
Due 10 May 2001
Resolved 21 May 2001
Lifesaving
Issued 10 April 2001
Resolved
PROVIDE INSTRUCTION FOR THE RESCUE BOAT IAW THE REGULATION UNDER 4.4 & 4.5 OF THE CCSSC CODE.
Condition: Unknown
Due 10 May 2001
Resolved 21 May 2001
Documentation
Issued 21 September 1999
Resolved
PROVDE MARINE CHEMIST OR SHIP YARD COMPETENT PERSON CERTIFICATE PRIOR TO CONTINUING WITH HOT WORK IN #5 STBD BALLAST TANK.
Condition: Unknown
Due 22 September 1999
Resolved 23 September 1999
Construction/Loadline
Issued 21 September 1999
Resolved
PROVIDE CLASS REPORT ATTESTING TO CONDITION OF REPAIRS IN #5 STARBOARD BALLAST TANK.
Condition: Unknown
Due 22 September 1999
Resolved 23 September 1999
Documentation
Issued 21 September 1999
Resolved
PROVIDE EVIDENCE OF STCW ENDORSEMENTS FOR ALL CREW AND OFFICERS AS LISTED ON THE MINIMUM SAFE MANNING DOCUMENT.
Condition: Unknown
Due 22 September 1999
Resolved 23 September 1999
Navigation
Issued 21 September 1999
Resolved
DEMONSTRATE THE PROPER OPPERATION OF THE AUXILARY STEERING GEAR IN THE ENGINEROOM TO THE SATISFACTION OF THE CLASS SOCIETY.
Condition: Unknown
Due 22 September 1999
Resolved 23 September 1999
Fire Fighting
Issued 21 September 1999
Resolved
REPAIR THE DEDICATED FIRE PUMP.
Condition: Unknown
Due 21 September 1999
Resolved 23 September 1999
Navigation
Issued 2 February 1999
Resolved
PROVIDE NORMAL AND EMERGENCY STEERING INSTRUCTION ON BRIDGE.
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Engineering
Issued 2 February 1999
Resolved
PROVIDE OVERSPEED SHUTDOWNS FOR PORT AND STARBOARD MAIN ENGINES TO SATISFACTION OF CLASS.
Condition: Unknown
Due 7 April 1999
Resolved 7 April 1999
Engineering
Issued 2 February 1999
Resolved
PROVIDE OVERSPEED SHUTDOWNS FOR PORT AND STARBOARD GENERATORS TO SATISFACTION OF CLASS.
Condition: Unknown
Due 7 April 1999
Resolved 7 April 1999
Navigation
Issued 2 February 1999
Resolved
PROVIDE NORMAL AND EMERGENCY STEERING INSTRUCTION AT EMERGENCY STEERING STATION.
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Electrical
Issued 2 February 1999
Resolved
PROVIDE COVERS TO LIGHT FIXTURES IN STEERING ROOM AND TUNNEL.
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Lifesaving
Issued 10 April 1998
Resolved
CONDUCT LAUNCHING AND RECOVERY OPERATIONS WITH RESCUE BOAT LOADED WITH REQUIRED CREW COMPLEMENT AND TO BE WITNESSED BY C.G. INSPECTOR.
Condition: Unknown
Due 16 April 1998
Resolved 16 April 1998
Lifesaving
Issued 12 January 1998
Resolved
CONDUCT LAUNCHING AND RECOVERY OPERATIONS WITH RESCUE BOAT LOADED WITH REQUIRED CREW COMPLEMENT AND TO BE WITNESSED BY C.G. MARINE INSPECTOR.
Condition: Unknown
Due 16 April 1998
Resolved 16 April 1998
Electrical
Issued 12 January 1998
Resolved
REPAIR EMERGENCY LIGHT IN ALLEYWAY BY CO2 BOTTLES TOWARD THE ENGINE ROOM.
Condition: Unknown
Due 1 April 1998
Resolved 1 April 1998
Construction/Loadline
Issued 12 January 1998
Resolved
REPAIR PORT FORWARD BOW MOORING BIT HORN-WASTED.
Condition: Unknown
Due 1 April 1998
Resolved 1 April 1998
Construction/Loadline
Issued 12 January 1998
Resolved
REPAIR WATERTIGHT DOOR TO ENGINE ROOM VIA ALLEYWAY--LOCKING DOG OUT OF BUSHING SLOT.
Condition: Unknown
Due 1 April 1998
Resolved 1 April 1998
Navigation
Issued 12 January 1998
Resolved
PROVIDE UPDATED DEVIATION TABLE.
Condition: Unknown
Due 1 April 1998
Resolved 1 April 1998
Electrical
Issued 12 January 1998
Resolved
PROVIDE EMERGENCY SOURCE OF ELECTRICAL POWER.
Condition: Unknown
Due 1 April 1998
Resolved 1 April 1998
Electrical
Issued 12 January 1998
Resolved
SHOW PROPER PROOF OF COMMUNICATION BETWEEN BRIDGE AND ENGINE ROOM.
Condition: Unknown
Due 1 April 1998
Resolved 1 April 1998
Navigation
Issued 12 January 1998
Resolved
PROVIDE MEANS OF ALTERNATE STEERING GEAR AND TEST IT IN THE PRESENCE OF COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 1 April 1998
Resolved 1 April 1998
Documentation
Issued 12 January 1998
Resolved
PROVIDE APPROVED SHIPBOARD OIL POLLUTION EMERGENCY PLAN REVIEWED BY THE ADMINISTRATION.
Condition: Unknown
Due 1 April 1998
Resolved 1 April 1998
Engineering
Issued 12 January 1998
Resolved
REPAIR ALL ENGINE TACHOMETER AND GUAGES IN WHEEL HOUSE.
Condition: Unknown
Due 8 April 1998
Resolved 8 April 1998
Electrical
Issued 12 January 1998
Resolved
REPAIR PORT ENGINE EMERGENCY SHUTDOWN SWITCH IN WHEEL HOUSE.
Condition: Unknown
Due 1 April 1998
Resolved 1 April 1998
Electrical
Issued 12 January 1998
Resolved
INSTALL EMERGENCY LIGHT ON BRIDGE.
Condition: Unknown
Due 1 April 1998
Resolved 1 April 1998
Documentation
Issued 17 July 1997
Resolved
PROVIDE PROOF OF AN APPLICATION FOR A CSSC CERTIFICATE FROM FLAG STATE. 1JAN98 VSL IS TO HAVE A VALID CSSC CERTIFICATE.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Lifesaving
Issued 6 December 1996
Resolved
ENSURE ALL LIFE RINGS ARE LABLED WITH THE VESSEL'S NAME & HOMEPORT PER 46 C.F.R. 97.37-43.
Condition: Unknown
Due 20 February 1997
Resolved 20 February 1997
Engineering
Issued 6 December 1996
Resolved
REPLACE FLAME SCREENS ON ALL FUEL VENTS (USE 30/30 MESH OR 2 LAYER 20/20 1/2" APART)
Condition: Unknown
Due 27 February 1997
Resolved 28 February 1997
Electrical
Issued 6 December 1996
Resolved
ENSURE ALL EMERGENCY LIGHTING IS WORKING PROPERLY PER 46 C.F.R. TABLE 112.05-5(a) & 46 C.F.R. 112.15-1.
Condition: Unknown
Due 20 February 1997
Resolved 20 February 1997
Fire Fighting
Issued 26 October 1996
Resolved
VESSEL MUST MOUNT FIRE EXTINGUISHER IN AFT ENGINE ROOM SPACE IN PROPER BRACKER IN ACCORDANCE WITH 46 CFR 95. VESSEL MUST CORRECT DEFICIENCY BY 26 NOV96.
Condition: Unknown
Due 6 December 1996
Resolved 6 December 1996
Deck/Cargo
Issued 26 October 1996
Resolved
VESSEL MUST RENEW HOLED CARGO CONTAINMENT AND CARGO PIPING VALVES FOR ASPHALT TANK AS REQUIRED BY 33 CFR 155.310. VESSEL MUST CORRECT DEFICIENCYPRIOR BY 26NOV96.
Condition: Unknown
Due 6 December 1996
Resolved 6 December 1996
Navigation
Issued 26 October 1996
Resolved
VESSEL MUST REPLACE AUTOMOBILE BATTERY FOR GENERAL ALARM WITH MARINE BATTERY AS REQUIRED BY 46 CFR 90.25. VESSEL CORRECTED DEFICIENCY PRIOR TO DEPARTURE.
Condition: Unknown
Due 26 October 1996
Resolved 31 October 1996
Fire Fighting
Issued 26 October 1996
Resolved
VESSEL'S FIRE PUMP WAS NOT WORKING PROPERLY AS REQUIRED BY 46 CFR 95.10._x001C_ VESSEL CORRECTED DEFICIENCY PRIOR TO DEPARTURE.
Condition: Unknown
Due 26 October 1996
Resolved 31 October 1996
Fire Fighting
Issued 26 October 1996
Resolved
VESSEL WAS MISSING THREE FIRE HOSES AS REQUIRED BY 46 CFR 95.10-10. VESSEL CORRECTED DEFICIENCY PRIOR TO DEPARTURE.
Condition: Unknown
Due 26 October 1996
Resolved 31 October 1996
Navigation
Issued 26 October 1996
Resolved
VESSEL ENTERED THE PORT OF SAN JUAN WITHOUT CURRENT TIDE TABLES, A VIOLATION OF 46 CFR 97.05. VESSEL CORRECTED DEFICIENCY PRIOR TO DEPARTURE.
Condition: Unknown
Due 26 October 1996
Resolved 31 October 1996
Navigation
Issued 26 October 1996
Resolved
VESSEL ENTERED THE PORT OF SAN JUAN WITHOUT CURRENT COPY OF TIDAL CURRENT TABLES, A VIOLATION OF 46 CFR 97.05. VESSEL CORRECTED DEFICIENCY PRIOR TO DEPARTURE.
Condition: Unknown
Due 26 October 1996
Resolved 31 October 1996
Navigation
Issued 26 October 1996
Resolved
VESSEL ENTERED THE PORT OF SAN JUAN WITHOUT CURRENT CHARTS FOR THE AREA AS REQUIRED BY 46 CFR 97.05. VESSEL CORRECTED DEFICIENCY PRIOR TO DEPARTURE.
Condition: Unknown
Due 26 October 1996
Resolved 31 October 1996
Documentation
Issued 26 October 1996
Resolved
VESSEL ENTERED THE PORT OF SAN JUAN WITH AN INVALID SAFETY RADIO CERTIFICATE AS REQUIRED UNDER SOLAS CHAPTER V. VESSEL CORRECTED DEFICIENCY PRIOR TO DEPARTURE.
Condition: Unknown
Due 26 October 1996
Resolved 31 October 1996
Navigation
Issued 26 October 1996
Resolved
VESSEL ENTERED THE PORT OF SAN JUAN WITHOUT CURRENT COAST GUARD PILOT AS REQUIRED BY 46 CFR 97.05. VESSEL CORRECTED DEFICIENCY PRIOR TO DEPARTURE.
Condition: Unknown
Due 26 October 1996
Resolved 31 October 1996
Navigation
Issued 26 October 1996
Resolved
VESSEL MUST DETERMINE CAUSE OF LEAK FROM POST STARBOARD RUDDER POST AS REQUIRED BY 46 CFR 96.03. VESSEL CORRECTED DEFICIENCY PRIOR TO DEPARTURE.
Condition: Unknown
Due 26 October 1996
Resolved 31 October 1996
Electrical
Issued 26 October 1996
Resolved
VESSEL ENTERED THE PORT OF SAN JUAN WITHOUT ELECTRICAL LIGHTING IN THE STEERING ROOM. A REQUIREMENT OF 46 CFR 90.25. VESSEL CORRECTED DEFICIENCY PRIOR TO DEPARTURE.
Condition: Unknown
Due 26 October 1996
Resolved 31 October 1996
Navigation
Issued 26 October 1996
Resolved
VESSEL'S STEERING GEAR TELEMOTOR UNIT MISSING NUT AND COTTER PIN AS REQUIRED BY 46 CFR 96.03. VESSEL CORRECTED DEFICIENCY PRIOR TO DEPARTURE.
Condition: Unknown
Due 26 October 1996
Resolved 31 October 1996
Navigation
Issued 26 October 1996
Resolved
VESSEL'S STEERING GEAR HYDRAULIC RAM WAS LEAKING, A VIOLATION UNDER 46 CFR 96.03. VESSEL CLEARED DEFICIENCY PRIOR TO DEPARTURE.
Condition: Unknown
Due 26 October 1996
Resolved 31 October 1996
Navigation
Issued 26 October 1996
Resolved
VESSEL MUST REMOVE HOLDING DEVICE FROM WATERTIGHT DOOR IN STEERING SPACE ASREQUIRED BY 46 CFR 42.15. VESSEL CORRECTED DEFICIENCY PRIOR TO DEPARTURE.
Condition: Unknown
Due 26 October 1996
Resolved 31 October 1996
Electrical
Issued 26 October 1996
Resolved
VESSEL MUST REPLACE MISSING HERTZ FREQUENCY METER FOR STARBOARD SHIP GENERATOR AS REQUIRED BY 46 CFR 90.25. VESSEL MUST CORRECT DEFICIENCY BY 26NOV96.
Condition: Unknown
Due 1 May 1997
Resolved 20 March 1997
Engineering
Issued 26 October 1996
Resolved
VESSEL MUST REPAIR PUMP FOR DISCHARGING OILYWATER ASHORE AS REQUIRED BY 33 CFR 155.420. VESSEL MUST CORRECT DEFICIENCY BY 26NOV96.
Condition: Unknown
Due 8 February 1997
Resolved 20 February 1997
Deck/Cargo
Issued 26 October 1996
Resolved
VESSEL MUST REPAIR STARBOARD ANCHOR BRAKE AS REQUIRED BY 46 CFR 96.07. VESSEL MUST CORRECT DEFICIENCY BY 26NOV96.
Condition: Unknown
Due 8 February 1997
Resolved 20 February 1997
Deck/Cargo
Issued 26 October 1996
Resolved
VESSEL MUST REPLACE CORRODED AND BENT STARBOARD ANCHOR CHAIN AS REQUIRED BY46 CFR 96.07 BY 26NOV96.
Condition: Unknown
Due 8 February 1997
Resolved 20 February 1997
Deck/Cargo
Issued 26 October 1996
Resolved
VESSEL MUST SHOW PROPER OPERATION OF PORT SIDE ANCHORING SYSTEM AS REQUIREDBY 46 CFR 96.07 BY 26NOV96.
Condition: Unknown
Due 8 February 1997
Resolved 20 February 1997
Deck/Cargo
Issued 26 October 1996
Resolved
VESSEL MUST REPAIR ALL HOLED FUEL TANK CONTAINMENT PANS. AS REQUIRED BY 33 CFR 155.310. VESSEL MUST CORRECT DEFICIENCIES BY 26NOV96.
Condition: Unknown
Due 8 February 1997
Resolved 20 February 1997
Documentation
Issued 6 November 1995
Resolved
NO VALID SAFE MANNING CERTIFICATE._x001C_ STCW 1978.
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Documentation
Issued 6 November 1995
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Fire Fighting
Issued 6 November 1995
Resolved
FIRE HYDRANT #1 VALVUE IS FROZEN CLOSED. _x001C_ 46 C.F.R. 95.10-10(d)(g)
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Documentation
Issued 6 November 1995
Resolved
OFFICERS LICENSES ARE NOT ISSUED BY THE FLAG STATE._x001C_ STCW 1978
Condition: Unknown
Due 6 February 1996
Resolved 6 February 1996
Navigation
Issued 6 November 1995
Resolved
charts 25670 and 25640 need all corrections _x001C_ 46 C.F.R. 97.05-05(a)
Condition: Unknown
Due 4 November 1996
Resolved 4 November 1996
Navigation
Issued 6 November 1995
Resolved
no corrections for us coast pilot vol. 5 1993 ed._x001C_ 46 C.F.R. 97.05-05(c)
Condition: Unknown
Due 4 November 1996
Resolved 4 November 1996
Navigation
Issued 6 November 1995
Resolved
no corrections to light list vol iii 1995._x001C_ 46 C.F.R 97.10-05(d)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 November 1996
Resolved 4 November 1996
Documentation
Issued 27 June 1994
Resolved
PROVIDE LETTER FROM FLAG STATE INDICATING ACCEPTANCE OF FOREIGN LICENSES.
Condition: Unknown
Due 13 July 1994
Resolved 22 July 1994
Documentation
Issued 27 June 1994
Resolved
PROVIDE SAFE MANNING CERTIFICATE FROM FLAG STATE.
Condition: Unknown
Due 13 July 1994
Resolved 22 July 1994
Navigation
Issued 27 June 1994
Resolved
PROVIDE CURRENT (3 YEARS OR LESS) CHARTS, COAST PILOT, TIDE TABLE, TIDAL CURRENT TABLE AND LIGHT LIST.
Condition: Unknown
Due 13 July 1994
Resolved 22 July 1994
Navigation
Issued 27 June 1994
Resolved
PROVIDE NAVIGATION LIGHTS IN ACCORDANCE WITH COLREGS.
Condition: Unknown
Due 13 July 1994
Resolved 22 July 1994
Lifesaving
Issued 27 June 1994
Resolved
PROVIDE LIFE JACKETS WITH LIGHTS AND WHISTLE FOR EACH CREW MEMBER AND PASSENGER ONBOARD.
Condition: Unknown
Due 13 July 1994
Resolved 22 July 1994
Documentation
Issued 27 June 1994
Resolved
PROVIDE OIL RECORD BOOK.
Condition: Unknown
Due 13 July 1994
Resolved 22 July 1994
Navigation
Issued 27 June 1994
Resolved
REPACK PORT RUDDER STOCK.
Condition: Unknown
Due 29 June 1994
Resolved 22 July 1994
Engineering
Issued 27 June 1994
Resolved
TIGHTEN PACKING GLANDS ON BOTH STUFFING BOXES (TAIL SHAFT).
Condition: Unknown
Due 13 July 1994
Resolved 22 July 1994
Construction/Loadline
Issued 27 June 1994
Resolved
PROVE PROPER OPERATION OF PORT WATER TIGHT DOOR FROM MAIN DECK TO ENGINE ROOM.
Condition: Unknown
Due 13 July 1994
Resolved 22 July 1994
Construction/Loadline
Issued 27 June 1994
Resolved
REMOVE OILY WATER FROM BILGES.
Condition: Unknown
Due 13 July 1994
Resolved 22 July 1994
Accommodation/Occupational Safety
Issued 27 June 1994
Resolved
REPLACE LIGHT FIXTURE IN CREWS SHOWER.
Condition: Unknown
Due 13 July 1994
Resolved 22 July 1994
Lifesaving
Issued 27 June 1994
Resolved
PROVIDE 6(SIX) RING LIFE BOUYS, 4(FOUR) WITH WATER LIGHTS IN ACCORDANCE WITH SOLAS REQUIREMENTS.
Condition: Unknown
Due 13 July 1994
Resolved 22 July 1994
Lifesaving
Issued 27 June 1994
Resolved
PROVIDE 1(ONE) ADDITIONAL RING BOUYS AND SMOKE AND LIGHT IN ACCORDANCE WITHSOLAS REQUIREMENTS.
Condition: Unknown
Due 13 July 1994
Resolved 22 July 1994
Lifesaving
Issued 27 June 1994
Resolved
PROVIDE 2(TWO) 10(TEN)MAN LIFERAFTS IN A PROPER FLOAT FREE ARRANGEMENT.
Condition: Unknown
Due 13 July 1994
Resolved 22 July 1994
Electrical
Issued 27 June 1994
Resolved
PROVIDE GLOBES AND GUARDS FOR ALL LIGHT FIXTURES THROUGHOUT THE VESSEL.
Condition: Unknown
Due 13 July 1994
Resolved 22 July 1994
Electrical
Issued 27 June 1994
Resolved
REPAIR ELECTRICAL CONDUIT FOR ANCHOR WINDLESS MOTOR.
Condition: Unknown
Due 13 July 1994
Resolved 22 July 1994
Engineering
Issued 27 June 1994
Resolved
PROVIDE PROPER REPAIRS TO ALL FIXED CONTAINMENTS IN WAY OF TANK VENTS.
Condition: Unknown
Due 13 July 1994
Resolved 22 July 1994
Documentation
Issued 27 June 1994
Resolved
PROVIDE WASTE MANAGEMENT PLAN AND GARBAGE LOG.
Condition: Unknown
Due 13 July 1994
Resolved 22 July 1994
Documentation
Issued 27 June 1994
Resolved
PROVIDE VESSEL DOCUMENTS FOR EXAMINATION.
Condition: Unknown
Due 13 July 1994
Resolved 22 July 1994
Construction/Loadline
Issued 22 April 1994
Resolved
LOAD LINE NOT MARKED IN ACCORDANCE WITH LOAD LINE CERTIFICATE.
Condition: Unknown
Due 29 April 1994
Resolved 5 May 1994
Documentation
Issued 12 November 1992
Resolved
VESSEL DID NOT HAVE ANY TRANSFER PROCEDURES.
Condition: Unknown
Due 18 December 1992
Resolved 18 December 1992
Accommodation/Occupational Safety
Issued 12 November 1992
Resolved
VESSEL'S MARINE SANITATION DEVICE WAS INOPERATIVE.
Condition: Unknown
Due 18 December 1992
Resolved 18 December 1992
Documentation
Issued 23 February 1987
Resolved
PROVIDE THE ORIGINAL STABILITY BOOKLET FOR THE VESSEL OR HAVE THE COPY ON BOARD CERTIFIED TO BE A TRUE COPY BY THE COAST GUARD. COMPLIANCE DATE IS 23MAR87.
Condition: Unknown
Due 23 February 1987
Resolved 23 February 1987
Documentation
Issued 23 February 1987
Resolved
PROVIDE FCC STATION LICENSE FOR THIS VESSEL. COMPLIANCE DATE IS 23MAR87.
Condition: Unknown
Due 23 February 1987
Resolved 23 February 1987
Construction/Loadline
Issued 23 February 1987
Resolved
AFFIX THE VESSELS NAME, HOMEPORT OR HAILING PORT AS PER 46 CFR 97.40-5. COMPLIANCE DATE IS 23MAR87.
Condition: Unknown
Due 23 February 1987
Resolved 23 February 1987
Documentation
Issued 23 February 1987
Resolved
PROVIDE A FUEL AIR TRANSFER PROCEDURE. COMPLIANCE DATE IS 23MAR87.
Condition: Unknown
Due 23 February 1987
Resolved 23 February 1987