MAURY USCG vessel records Sign in
← All vessels

DIAMOND 101

DIAMOND 101 is a 1980 passenger vessel (inspected). The Coast Guard has recorded 32 inspections since 1982, most recently in November 2010, along with 10 deficiencies.

Records from 1982 to 2010. Most recent: inspection, 29 November 2010.

Built
1980
Last inspected
29 November 2010
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC7870
Flag
UNITED STATES
367078270 (licence lapsed)
Maury page id
psix-51538

Inspections, by type

…with no type recorded4
Years with a record 25 calendar years (1982–2010)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)38.0 ft × 14.1 ft × 6.1 ft
Registered tonnagegross 20 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY-CRAFT, INC. · LOREAUVILLE, LA, UNITED STATES · built 1980
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Regulatory (Subpart C or D), Net Ton
20 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC7870MMSI 367078270 · expired · compulsorily equipped · granted 13 November 2015, cancelled 7 March 2026
WAJ3721MMSI not assigned · expired · compulsorily equipped · granted 6 March 1995, cancelled 23 March 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 32

29 November 2010 Hull Examination · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3910586
27 October 2008 Examination of Repairs · Hull Examination · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3352025
12 September 2007 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3056156
12 December 2005 Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2549807
28 October 2004 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2235286
23 October 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1937029
21 October 2002 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1693245
22 January 2002 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1480490
19 November 2001 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1444648
22 September 2000 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1405051
24 August 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 215119
19 August 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423235
6 August 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 213786
25 September 1998 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1434780
2 October 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1464727
21 August 1996 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357715
15 September 1995 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1446251
14 February 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 841620
9 September 1994 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358520
15 September 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409015
13 April 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 838036
7 August 1992 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448396
2 March 1992 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1314988
22 August 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 939637
17 September 1990 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1228573
27 September 1989 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1019304
8 November 1988 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1208665
26 January 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322550
15 August 1986 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315421
11 August 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 984805
8 November 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277425
9 February 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271389

Deficiency record · 10

Documentation › Certificates/Documents
Issued 22 January 2002 Resolved
PROVIDE STABILITY LETTER ON BOARD VESSEL. LEGACY COMPONENT DESC: Stability Letter
Due 22 February 2002
Resolved 17 December 2002
Fire Fighting
Issued 19 November 2001 Resolved
VESSEL NOT TO OPERATE UNTIL VSL HAS HAND FIRE PUMP IAW 46 CFR 181.10-05 OLDSUBCHAPTER "T" OR THREE (3) FIRE BUCKETS IAW 46 CFR 181.610 NEW SUBCHAPTER "T".
Condition: Unknown
Due 19 December 2001
Resolved 20 November 2001
Engineering
Issued 19 November 2001 Resolved
REPAIR FUEL LEAK IN STEERING COMPARTMENT TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 19 December 2001
Resolved 22 January 2002
Electrical
Issued 19 November 2001 Resolved
PROPERLY LINE BATTERY BOXES IAW 46 CFR 183.05-20(d) OLD SUBCHAPTER "T".
Condition: Unknown
Due 19 December 2001
Resolved 22 January 2002
Navigation
Issued 19 November 2001 Resolved
REPAIR JOCKING BAR IN STEERING SYSTEM TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 19 December 2001
Resolved 22 January 2002
Documentation
Issued 19 November 2001 Resolved
PROPERLY POST STABILITY LETTER IAW 46 CFR 185.12-1(a) OLD SUBCHAPTER "T".
Condition: Unknown
Due 19 December 2001
Resolved 17 December 2002
Engineering
Issued 19 November 2001 Resolved
PROPERLY INSTALL MACHINERY GUARDS IAW 46 CFR 171.35-13(a) OLD SUBCHAPTER "T".
Condition: Unknown
Due 19 December 2001
Resolved 22 January 2002
Electrical
Issued 19 November 2001 Resolved
INSTALL AND PROVE PROPER OPERATION OF VOLT METER, AMP METER AND MEANS OF MEASURING CYCLES IAW 183.10-5(g) OLD SUBCHAPTER "T".
Condition: Unknown
Due 19 December 2001
Resolved 22 January 2002
Fire Fighting
Issued 15 September 1995 Resolved
PROVIDE A PORTABLE FIRE PUMP WITH HOSES.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Fire Fighting
Issued 15 September 1995 Resolved
PROVIDE ANNUAL SERVICING OF ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.