Records from 1982 to 2005. Most recent: inspection, 24 May 2005.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 35
24 May 2005
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2367238
17 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1968287
22 August 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1052850
10 September 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1438896
20 August 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1418585
14 June 1999
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 807538
11 June 1999
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 808496
10 June 1999
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 808236
27 May 1999
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1454665
8 March 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1426185
26 January 1999
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1453539
28 April 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1124224
11 March 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364610
20 March 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1377987
11 June 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 690648
10 April 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214033
10 April 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1387996
13 March 1995
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1360029
22 March 1994
COI Inspection · Deficiency Check · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1407275
5 February 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1414106
5 March 1992
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 949182
5 February 1991
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 910426
3 January 1991
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1237380
17 January 1990
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 904131
30 January 1989
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1038074
9 September 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1202239
20 January 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319880
13 January 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1011195
31 December 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015246
13 July 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1029639
13 April 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322003
7 February 1986
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987590
6 August 1985
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 989821
29 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974157
8 April 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971758
Construction/Loadline
Issued 27 May 1999
Resolved
REPAIR OWS OIL CONTENT METER, AND PROVE OPERATION TO CG INSPECTOR.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Electrical
Issued 27 May 1999
Resolved
REMOVE ALL PLASTIC WIRE TIES IN HORIZONTAL WIRE RUNS AND RENEW WITH METAL BANDS.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Fire Fighting
Issued 27 May 1999
Resolved
REPAIR LEAKS ON NR. 4 FIRE STATION.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Accommodation/Occupational Safety
Issued 27 May 1999
Resolved
INSTALL A REMOTE SHUTDOWN FOR ENGINE ROOM VENTILATION SYSTEM OUTSIDE THE ENGINEROOM.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Fire Fighting
Issued 27 May 1999
Resolved
RENEW/REPAIR FIRE PUMP DISCHARGE PRESSURE GAUGE.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Accommodation/Occupational Safety
Issued 27 May 1999
Resolved
REPAIR CLOSURE ON GALLEY RANGE VENTILATION SYSTEM.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Engineering
Issued 27 May 1999
Resolved
PAINT EMERGENCY FUEL SHUT-OFF VALVE RED.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Electrical
Issued 27 May 1999
Resolved
LABEL GALLEY RANGE CIRCUIT BREAKER.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Electrical
Issued 27 May 1999
Resolved
RENEW LIGHT COVER IN MAIN PASSAGEWAY.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Lifesaving
Issued 27 May 1999
Resolved
POST LIFE RAFT INSTRUCTIONS NEAR LIFE RAFTS.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Documentation
Issued 27 May 1999
Resolved
SUBMIT UPDATED FIRE AND SAFETY PLAN FOR APPROVAL.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Lifesaving
Issued 27 May 1999
Resolved
RENEW REFLECTIVE TAPE ON RING LIFE BUOYS.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Accommodation/Occupational Safety
Issued 27 May 1999
Resolved
INSTALL SAFETY RAILS IN WAY OF DIVE SHACK AND BOW EXIT.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Electrical
Issued 27 May 1999
Resolved
RENEW/REPAIR RPM METERS ON BOTH GENERATORS.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Electrical
Issued 27 May 1999
Resolved
RENEW REPAIR LUBE OIL PRESSURE GAUGE ON FORWARD GENERATOR.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Unknown
Issued 8 March 1999
Resolved
ENSURE VESSEL IS IN FULL COMPLIANCE WITH LOADLINE CERITIFICATE PRIOR TO GETTING UNDERWAY FOR SEA; NOTIFY MSO PORT ARTHUR TX UPON COMPLIANCE.
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Construction/Loadline
Issued 26 January 1999
Resolved
REMOVE BACKING STRIPS FROM INSERT ON OVERHEAD OF STBD FRESH WATER TANK AND COMPLETE FULL PENETRATION WELD.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Construction/Loadline
Issued 26 January 1999
Resolved
REPAIR PIN HOLE LOCATED APPROX 3 INCHES AFT OF BOTTOM INSERT OF STBD COFFERDAM. GAUGE AREA TO DETERMINE CONDITION OF EXISTING PLATING.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Construction/Loadline
Issued 26 January 1999
Resolved
MAKE REPAIRS TO HOLE IN WELD ON INSERT LOCATED ON BILGE KNUCKLE OF STBD COFFERDAM.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Construction/Loadline
Issued 26 January 1999
Resolved
COMPLETE BUTT WELDS ON THE #2 AND #5 LONGITUDINALS IN DOUBLE BOTTOM STBD SIDE BELOW GALLEY.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Construction/Loadline
Issued 26 January 1999
Resolved
IN PORT BALLAST TANK, CROP AND RENEW 3 FOOT WASTED SECTION OF DECK LONGS #1, 2, & 3 NUMBERED FROM OUTBOARD IN.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Documentation
Issued 10 April 1996
Resolved
SUBMIT TO COMDT FOR APPROVAL: SHIPBOARD OIL POLLUTION EMERGENCY PLAN PER 33CFR 151.09 AS DESCRIBED IN 33CFR155.26.
Condition: Unknown
Due 10 April 1996
Resolved 10 April 1996
Engineering
Issued 10 April 1996
Resolved
INSTALL AND DEMONSTRATE PROPER OPERATION OF OILY WATER SEPERATOR
Condition: Unknown
Due 10 May 1996
Resolved 15 May 1996
Lifesaving
Issued 22 March 1994
Resolved
PROVE PROPER OPERATION OF THE RESCUE BOAT DAVIT.
Condition: Unknown
Due 25 March 1994
Resolved 30 March 1994
Electrical
Issued 5 March 1992
Resolved
INSTALL LESS THAN 100 PSI/LESS THAN 210 DEGREES PRESS/TEMP RELIEF VALVE ON DOMESTIC HOT WATER HEATERS (2EA.) OR MAKE VESSELS AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Engineering
Issued 5 March 1992
Resolved
PROVE PROPER OPERATION OF REMOTE F/O SHUT OFF VALVE.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Unknown
Issued 9 September 1988
Resolved
CLEAN GENERATOR ROOM AND WELDING UNIT ROOM BILGES.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Unknown
Issued 9 September 1988
Resolved
REPAIR QUICK ACTING WATER TIGHT DOOR TO GENERATOR.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Unknown
Issued 9 September 1988
Resolved
REPAIR WIRING IN ACCORDANCE WITH APROVED PROCEEDURES IN WELDING UNIT ROOM AND GENERATOR ROOM.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Navigation
Issued 13 January 1988
Resolved
PROVIDE U/L STANDARD 1104 TYPE, APPROVED NAVIGATION LIGHTS. TO COMPLY WITHCURRENT COMDTINST M16672.2A AND 46 CFR SUBCHAPTER "J".
Condition: Unknown
Due 13 January 1988
Resolved 13 January 1988
Electrical
Issued 13 January 1988
Resolved
INSTALL NAVIGATION LIGHT WIRING TO WITH CURRENT REGULATIONS. 46 CFR 111.75-17 (E) 3.
Condition: Unknown
Due 13 January 1988
Resolved 13 January 1988
Deck/Cargo
Issued 7 February 1986
Resolved
INSTALL OIL WATER SEPARATOR. SLUDGE TANKD AND ASSOCIATED REQUIRED EQUIPMENT. ABOVE OILY WATER SEPARATOR SHALL BE A COAST GUARD APPROVED MODEL.
Condition: Unknown
Due 7 February 1986
Resolved 7 February 1986
Unknown
Issued 29 March 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL LPC 101 DN620491
Condition: Unknown
Due 29 April 1984
Resolved 29 March 1984
Unknown
Issued 29 March 1984
Resolved
WRITE DESIGNATING PERSON IN CHARGE.
Condition: Unknown
Due 29 April 1984
Resolved 29 March 1984
Unknown
Issued 29 March 1984
Resolved
INSTALL FUEL OIL CONTAINMENT AROUND FUEL OIL VENT
Condition: Unknown
Due 29 April 1984
Resolved 29 March 1984