Records from 1985 to 1993. Most recent: inspection, 27 July 1993.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 41
27 July 1993
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 845056
27 July 1993
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1155688
24 June 1993
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1153662
8 June 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 459852
2 June 1993
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 838636
11 January 1993
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 829452
5 November 1992
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 946591
4 November 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 100690
4 November 1992
Damage Survey · Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1138105
14 August 1992
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1248599
13 August 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 523945
27 March 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1260853
23 March 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 699946
12 January 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 648352
12 January 1992
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1314480
6 January 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 348343
9 August 1991
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1244571
21 June 1991
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1216749
13 March 1991
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 910571
10 March 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 527329
13 August 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 338610
13 August 1990
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 904770
18 January 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 493705
11 December 1989
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1215059
2 September 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1208286
31 August 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1201094
21 June 1989
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1350188
24 April 1989
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 523408
11 January 1989
Administrative
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1195178
10 January 1989
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 457250
13 August 1988
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1345308
28 January 1988
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 441750
8 January 1988
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1318891
23 September 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 311554
8 August 1986
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 998773
2 August 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 503142
10 May 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 308694
15 March 1986
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 476951
21 October 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 304788
20 July 1985
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 469300
10 February 1985
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 534713
Engineering
Issued 4 November 1992
Resolved
Prior to return to a U.S. port from next foreign voyage, make permanent repairs in way of the temporary repairs to the salt water piston cooling pump starter overboard discharge pipe.
Condition: Unknown
Due 4 November 1992
Resolved 4 November 1992
Construction/Loadline
Issued 4 November 1992
Resolved
Provide copy of Classification Society Report upon completion of special examination of the bow bottom plating required by Lloyd's Register Survey Report dated 04 November 1992.
Condition: Unknown
Due 30 June 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 6 January 1992
Resolved
AUTOMATIC CONTROLS FOR INERT GAS GENERATOR NOT WORKING PROPERLY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 March 1992
Resolved 4 March 1992
Deck/Cargo
Issued 6 January 1992
Resolved
OXYGEN ANALYZER FOR INERT GAS GENERATOR NOT FUNCTIONING PROPERLY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Deck/Cargo
Issued 21 June 1991
Resolved
PROVIDE AUDIBLE HIGH LEVEL ALARM ON DECK PRIOR TO NEXT U.S. PORT CALL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 June 1991
Resolved 21 June 1991
Deck/Cargo
Issued 21 June 1991
Resolved
REPAIR AND PROVE PROPER OPERATION OF OXYGEN ANALYZER FOR INERT GAS GENERATOR PRIOR TO CONDUCTING CARGO OPERATIONS AT NEXT U.S. PORT CALL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 June 1991
Resolved 21 June 1991
Deck/Cargo
Issued 21 June 1991
Resolved
REPAIR AND PROVE PROPER OPERATION OF AUTOMATIC CONTROLS FOR INERT GAS GENERATOR PRIOR TO CONDUCTING CARGO OPERATIONS AT NEXT U.S. PORT CALL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 June 1991
Resolved 21 June 1991
Deck/Cargo
Issued 13 March 1991
Resolved
PRIOR TO NEXT U.S. PORT, MAKE PERMANENT REPAIRS TO THE HOLED INERT GAS PIPING IMMEDIATELY DOWNSTREAM FROM THE WATER SEPARATOR.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Fire Fighting
Issued 13 August 1990
Resolved
INSTALL FIXED FIRE FIGHTING SYSTEM IN PORT FOC'SLE PAINT LOCKER PRIOR TO THE NEXT U.S. VOYAGE.
Condition: Unknown
Due 13 August 1990
Resolved 13 August 1990
Deck/Cargo
Issued 13 August 1990
Resolved
EFFECT REPAIRS TO THE INERT GAS GENERATOR COOLING TOWER AND PROVE PROPER OPERATION OF THE SYSTEM AND ALARMS AT NEXT U.S. VOYAGE IN ACCORDANCE WITH 46CFR154.906.
Condition: Unknown
Due 13 August 1990
Resolved 13 August 1990
Construction/Loadline
Issued 2 September 1989
Resolved
MAKE PERMANENT REPAIRS TO FORWARD STBD AIRLOCK DOOR(MAKE OUTER DOOR GAS TIGHT).
Condition: Unknown
Due 2 September 1989
Resolved 2 September 1989
Construction/Loadline
Issued 31 August 1989
Resolved
MAKE TEMPORARY REPAIRS TO FWD STBD AIRLOCK DOOR (MAKE OUTER DOOR GAS TIGHT)
Condition: Unknown
Due 31 August 1989
Resolved 31 August 1989
Fire Fighting
Issued 31 August 1989
Resolved
PROVE PROPER OPERATION OF DECK SPRAY.
Condition: Unknown
Due 31 August 1989
Resolved 31 August 1989
Electrical
Issued 31 August 1989
Resolved
REPAIR ELECTRICAL CONNECTION ON PORT FORWARD ARM DAVIT ON LIFEBOAT LIMIT SWITCH.
Condition: Unknown
Due 31 August 1989
Resolved 31 August 1989
Deck/Cargo
Issued 31 August 1989
Resolved
PROPERLY MARK CARGO PIPING LIQUID AND VAPOR.
Condition: Unknown
Due 31 August 1989
Resolved 31 August 1989
Unknown
Issued 31 August 1989
Resolved
REPLACE GLOBES IN BOS'N STORES FOR THE EXPLOSION PROOF LIGHTS.
Condition: Unknown
Due 31 August 1989
Resolved 31 August 1989
Documentation
Issued 8 August 1986
Resolved
PRIOR TO ENTERING US WATERS AFTER 15AUG86, PROVIDE AN IMO MEDICAL GUIDE ON BOARD.
Condition: Unknown
Due 8 August 1986
Resolved 8 August 1986
Deck/Cargo
Issued 8 August 1986
Resolved
PRIOR TO ENTERING US WATERS AFTER 15AUG86, MAKE PERMANENT REPAIRS TO 2 LEAKS IN THE IGS GENERATOR COOLING WATER JACKET.
Condition: Unknown
Due 8 August 1986
Resolved 8 August 1986
Deck/Cargo
Issued 8 August 1986
Resolved
PRIOR TO ENTERING US WATERS AFTER 15AUG86, INSTALL MECHANICAL PLUGS IN CARGO MANIFOLD DRIP PANS.
Condition: Unknown
Due 8 August 1986
Resolved 8 August 1986
Deck/Cargo
Issued 8 August 1986
Resolved
PRIOR TO ENTERING US WATERS AFTER 15AUG86, PROVIDE DRAGER TUBES FOR ISOPRENE.
Condition: Unknown
Due 8 August 1986
Resolved 8 August 1986
Lifesaving
Issued 8 August 1986
Resolved
PRIOR TO ENTERING US WATERS AFTER 15AUG86, PROVIDE 15 MIN. EEBA'S FOR EVERY PERSON ON BOARD AND 2 ADDITIONAL FOR THE NAVIGATION BRIDGE.
Condition: Unknown
Due 8 August 1986
Resolved 8 August 1986
Deck/Cargo
Issued 21 October 1985
Resolved
REMOVE THE PAINT FROM THE FUSIBLE PLUGS AT ALL CARGO TANK DOMES.
Condition: Unknown
Due 21 October 1985
Resolved 21 October 1985
Construction/Loadline
Issued 21 October 1985
Resolved
RENEW THE WASTED AIR ACTUATING LINE LOCATED AFT OF THE COMPESSOR ROOM (NEXT TO THE LADDER)
Condition: Unknown
Due 21 October 1985
Resolved 21 October 1985
Documentation
Issued 21 October 1985
Resolved
VESSEL WAS LOADING AN UNAUTHORIZED CARGO OF PROPYLENE, PRIOR TO CARRING PROPYLENE IN US WATERS, MAKE ARRANGEMENTS WITH THE ISSUING AUTHORITY TO AMEND THE CERTIFICATE OF FITNESS FOR THE AUTHORIZATION TO CARRY PROPYLENE AS REQUIRED BY 46CFR154(A).
Condition: Unknown
Due 21 October 1985
Resolved 21 October 1985
Documentation
Issued 21 October 1985
Resolved
VESSEL'S OIL TRANSFER PROCEDURES WERE INCOMPLETE AS PER 33CFR155.750; INCLUDE SECTIONS (A)(1),(A)(2),(A)(3),(A)(5),& (A)(7).
Condition: Unknown
Due 21 October 1985
Resolved 21 October 1985