MAURY USCG vessel records Sign in
← All vessels

HAVPIL

HAVPIL is a 1977 tank ship. The Coast Guard has recorded 68 inspections since 1985, most recently in January 2007, along with 21 deficiencies and 12 operational controls.

Records from 1985 to 2007. Most recent: inspection, 14 January 2007.

Built
1977
Last inspected
14 January 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7414145 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
UNITED KINGDOM
—
Maury page id
psix-51580

Inspections, by type

…with no type recorded41
Years with a record 22 calendar years (1985–2007)
The 68 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it3393 - Convention (Subpart B), Net Ton
3393 - Regulatory (Subpart C or D), Net Ton
11460 - Dead Weight, Ton
9445 - Convention (Subpart B), Gross Ton
9445 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

P.D. CO. 114 Tank Barge · MISLE 50825 · 5 October 1994 · activity 147864

Inspection history · 68

14 January 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2855708
13 October 2006 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2800176
15 September 2006 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2779382
13 August 2006 Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2745954
24 October 2005 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2473441
20 June 2005 ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2394447
17 June 2005 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2393957
19 May 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2362487
5 May 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2349979
14 September 2004 COC-GAS Renew · Ballast Water Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2195730
9 June 2004 MTSA/ISPS Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2093672
26 November 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1954909
26 November 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1955741
16 June 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1818820
2 November 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1701281
4 October 2002 Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1685152
3 October 2002 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1684406
20 September 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1685687
22 March 2002 Security Inspection · In-Service Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1495995
20 March 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1495498
20 March 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1495511
16 January 2002 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1479372
30 October 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 295157
30 October 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 772617
29 October 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 295137
15 July 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 280039
15 July 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1051606
29 November 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 423119
14 August 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 406851
14 August 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1119700
15 May 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 403521
15 May 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1091448
21 September 1996 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 395689
14 November 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 384754
14 October 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1185177
7 October 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 702546
5 October 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 147864
4 October 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1172227
4 June 1994 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 367719
27 May 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1017799
26 May 1994 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 861392
5 September 1993 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1446020
31 August 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 491822
24 August 1992 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 947874
11 June 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1268009
6 February 1992 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1260550
14 May 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 447552
26 March 1991 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 904898
25 January 1991 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1244007
9 August 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 452047
19 February 1990 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1239762
17 July 1989 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 476181
8 February 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 328367
2 February 1989 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 463327
2 February 1989 Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1342784
23 July 1988 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1033745
3 March 1988 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1027652
2 March 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 442540
9 February 1987 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1015135
5 February 1987 Certificate of Compliance
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015515
5 February 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1324013
5 October 1986 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1315441
11 July 1986 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 310096
11 January 1986 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 451099
28 November 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 999683
19 November 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 441416
19 November 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1302703
29 April 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 301715

Deficiency record · 21

Construction/Loadline › Structures › Door
Issued 20 June 2005 Resolved
Replace missing handles on weather tight door located on main deck above the entrance to the steering gear room on deck store door. To the satisfaction of class.
Action required: 15 - Rectify deficiencies by next port
Resolved 13 August 2006
Resolution: Vessel provided letter from class.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 20 June 2005 Resolved
Replace missing door "A-60" located below exterior steering gear room entrance into passage way. To the satisfaction of class.
Action required: 15 - Rectify deficiencies by next port
Resolved 13 August 2006
Resolution: Vessel provided letter from class
Deck/Cargo
Issued 14 August 1997 Resolved
Flammable gas detectors not tested during exam, due to crew's unwillingnessor unreadiness to test equipment. _x001C_ Cite: IGC 13.6 .
Condition: Unknown
Due 14 August 1997
Resolved 20 August 1997
Lifesaving
Issued 14 August 1997 Resolved
Lifeboat rudders found unserviceable on port and starboard lifeboats. _x001C_ Cite: 60 SOLAS III/11
Condition: Unknown
Due 14 August 1997
Resolved 20 August 1997
Deck/Cargo
Issued 14 August 1997 Resolved
Motor room positive air pressure alarm bypassed from the bulkhead sensor toa sensor on the fan outlet duct. This arrangement bypassed the sensor's ability to deenergize the motorroom upon loss of overpressurization._x001C_ Cite: IGC 10.2.5.4
Condition: Unknown
Due 14 August 1997
Resolved 20 August 1997
Deck/Cargo
Issued 14 August 1997 Resolved
Motor room air lock alarm found inoperative._x001C_ Cite: IGC 3.6.3
Condition: Unknown
Due 14 August 1997
Resolved 20 August 1997
Lifesaving
Issued 15 May 1997 Resolved
VSL IS MISSING ONE OF TWO REQUIRED WARNING SIGNS AS REQUIRED BY 46 CFR 1830. TO BE CORRECTED BY 01JUN97.
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Documentation
Issued 4 October 1994 Resolved
PRIOR TO DEPARTURE FROM THE PORT OF HOUSTON, PROVIDE QUALIFIED SECOND ENGINEER ONBOARD VESSEL IAW MINIMUM SAFE MANNING CERTIFICATE OR EQUIVALENT TO SATISFACTION OF FLAG ADMINISTRATION.
Condition: Unknown
Due 8 November 1994
Resolved 8 November 1994
Navigation
Issued 25 January 1991 Resolved
ECHO SOUNDER INOPERATIVE_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 January 1991
Resolved 25 January 1991
Unknown
Issued 2 February 1989 Resolved
MAKE PERMANENT REPAIRS TO IGS PIPING FWD AND STBD #4 TANK.
Condition: Unknown
Due 2 February 1989
Resolved 2 February 1989
Unknown
Issued 2 February 1989 Resolved
TEST/PROVE PROPER OPERATIONS OF EMERGENCY SHUTDOWN ON #2 & #3 CARGO TANK DEEPWELL PUMPS TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 2 February 1989
Resolved 2 February 1989
Unknown
Issued 2 February 1989 Resolved
MAKE PERMANENT REPAIRS TO DECK SPRAY RISER IN WAY OF #2 TANK.
Condition: Unknown
Due 2 February 1989
Resolved 2 February 1989
Unknown
Issued 3 March 1988 Resolved
HAVE DECK DRY POWDER SYSTEM FOR FIRE FIGHTING SERVICED AS WELL AS ALL PORTABLE FIRE EXTINGUISHERS AND SUPPLY COAST GUARD WITH WRITTEN REPORT OF THE SAME.
Condition: Unknown
Due 3 March 1988
Resolved 3 March 1988
Unknown
Issued 3 March 1988 Resolved
PIROR TO UTILIZING PORTABLE CARGO HOSES FOR CARGO TRANSFER OPERATION IN U.S. PORTS HAVE HOSES PROPERLY TESTED (11/3 MAWP) AND SUPPLY U.S. COAST GUARD WITH WRITTEN DOCUMENTATION OF THE SAME.
Condition: Unknown
Due 3 March 1988
Resolved 3 March 1988
Unknown
Issued 3 March 1988 Resolved
PRIOR TO CONDUCTING/LOADING CARGO OPS IN U. S. PORT MAKE REPAIRS TO FIXED GAS DETECTION SYSTEM AND DEMONSTRATE SATISFACTORY OPERATION OF THE SAME TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 3 March 1988
Resolved 3 March 1988
Unknown
Issued 3 March 1988 Resolved
PRIOR TO CARRYING CARGOES IN U. S. PORTS REQUIRING INERT GAS GENERATOR SYSTEM MAKE REPAIRS TO THE SAME AND DEMONSTRATE SATISFACTORY OPERATION OF THE SAME TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 3 March 1988
Resolved 3 March 1988
Unknown
Issued 3 March 1988 Resolved
PRIOR TO DISCHARGING CARGO IN U.S. PORT DEMONSTRATE SATISFACTORY OPERATION OF CARGO PUMP EMERGENCY SHUT DOWN SYSTEMS.
Condition: Unknown
Due 3 March 1988
Resolved 3 March 1988
Unknown
Issued 3 March 1988 Resolved
PRIOR TO ENTRY INTO U. S. PORT MAKE PERMANENT REPAIRS TO TEMPORARY REPAIRS (DOUBLER PATCH) LOCATED IN WAY OF FIRE MAIN PIPING SYSTEM FWD OF DECK HOUSEPORT SIDE OF VESSEL.
Condition: Unknown
Due 3 March 1988
Resolved 3 March 1988
Unknown
Issued 9 February 1987 Resolved
SUBMIT NEW IMO CERTIFICATE OF FITNESS TO COMDT (G-MTH-1) AND OBTAIN A NEW CARGOES AND RESTRICTIONS LIST.
Condition: Unknown
Due 9 February 1987
Resolved 9 February 1987
Unknown
Issued 5 October 1986 Resolved
SUBMIT NEW IMO CERTIFICATE OF FITNESS TO COMDT (G-MTH-1) AND PROVIDE ONBOARD AN UPDATED CARGOES AND RESTRICTIONS LIST.
Condition: Unknown
Due 5 October 1986
Resolved 5 October 1986
Unknown
Issued 5 October 1986 Resolved
PROVIDE SUITABLE EMERGENCY ESCAPE DEVICES COMPLYING WITH IMO GAS CODE 17.2.(I.E.) 15 MINUTE ESCAPE BREATHING APPARATUS FOR EACH CREW MEMBER.
Condition: Unknown
Due 5 October 1986
Resolved 5 October 1986

Ownership record