Records from 1985 to 1998. Most recent: inspection, 21 January 1998.
Inspection history · 36
21 January 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 524154
12 January 1998
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 411917
11 January 1998
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 756911
10 January 1998
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 209915
17 September 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 407875
9 August 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 405879
9 August 1997
Tank Vessel Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 783161
6 September 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 394917
19 July 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 393732
2 December 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 385201
13 October 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 383870
11 August 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 381575
24 May 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 536678
29 October 1994
Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1374160
13 April 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 365909
19 December 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 508343
8 December 1993
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 849341
24 September 1993
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1158646
28 July 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1157408
26 July 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 139802
15 April 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 357592
2 April 1993
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 505023
2 April 1993
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 842239
11 September 1992
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1261529
10 September 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 533440
9 May 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 508664
30 June 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 344793
30 June 1991
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1247007
3 March 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 335849
3 March 1990
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1225153
22 June 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 324045
28 September 1987
Certificate of Compliance
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1011243
26 August 1987
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 494224
14 October 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 311952
14 October 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1009410
20 April 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 526526
Deck/Cargo
Issued 12 January 1998
No resolution recorded
Upon inspection of port slop tank found 2 inch fracture located on second plate, 8 feet above keel at frame 66. Fracture drilled stop and two self tapping screws applied temporary epoxy patch applied over screws.
Condition: Unknown
Due 16 January 1998 — due date passed with no resolution recorded
Deck/Cargo
Issued 12 January 1998
No resolution recorded
Inspection of #1 port cargo tank found two doubler patches on second side shell plate below main deck on frames 202 and 206. Doubler patch on frame 206 has crack on weld and carries into side shell, approximately 2 inches. Temporary epoxy patch applied to crack.
Condition: Unknown
Due 16 January 1998 — due date passed with no resolution recorded
Construction/Loadline
Issued 9 August 1997
Resolved
Vessel to repaint loadline in contrasting colors prior to next US Port._x001C_ as required by ILLC 66 Annex I/8
Condition: Unknown
Due 18 September 1997
Resolved 18 September 1997
Fire Fighting
Issued 9 August 1997
Resolved
Vessel to repair exhaust leak on emergency fire pump prior to next US port.SOLAS II/2 REG 04
Condition: Unknown
Due 18 September 1997
Resolved 18 September 1997
Lifesaving
Issued 9 August 1997
Resolved
Vessel to replace outdated flares. SOLAS 60 III/24
Condition: Unknown
Due 10 August 1997
Resolved 11 August 1997
Construction/Loadline
Issued 19 July 1996
Resolved
Make available for internal inspection #2 Port & Starboard wing ballast tanks.
Condition: Unknown
Due 6 September 1996
Resolved 6 September 1996
Deck/Cargo
Issued 19 July 1996
Resolved
Demonstrate proper operation of Inert Gas #1 blower fan.
Condition: Unknown
Due 6 September 1996
Resolved 6 September 1996
Deck/Cargo
Issued 19 July 1996
Resolved
Properly seal butterworth plates on cargo tanks #2 starboard, #4 port and center._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 September 1996
Resolved 6 September 1996
Navigation
Issued 19 July 1996
Resolved
Demonstrate proper operation of the steering gear low hydraulic oil level alarm.
Condition: Unknown
Due 6 September 1996
Resolved 6 September 1996
Electrical
Issued 19 July 1996
Resolved
Demonstrate automatic start and proper operation of the emergency generatorunder load.
Condition: Unknown
Due 6 September 1996
Resolved 6 September 1996
Deck/Cargo
Issued 19 July 1996
Resolved
renew cargo tank P/V flame screens(conduct adequate maintance to eliminate gaps around screen seals).
Condition: Unknown
Due 6 September 1996
Resolved 6 September 1996
Deck/Cargo
Issued 13 October 1995
Resolved
REPLACE INERT GAS HIGH TEMPERATURE PROBE AND CONDUCT SATISFACTORY OPERATIONAL TEST OF ALARM PRIOR TO CONDUCTING CARGO OPERATIONS.
Condition: Unknown
Due 20 October 1995
Resolved 26 October 1995
Engineering
Issued 13 October 1995
Resolved
RECONNECT HAND EASING GEAR TO STARBOARD BOILER SAFETY VALVE.
Condition: Unknown
Due 16 October 1995
Resolved 16 October 1995
Fire Fighting
Issued 13 October 1995
Resolved
MAKE PERMANENT REPAIRS TO FIRE AND TANK CLEANING PUMP DISCHARGE VALVE.
Condition: Unknown
Due 20 October 1995
Resolved 26 October 1995
Engineering
Issued 13 October 1995
Resolved
MAKE PERMANENT REPAIRS TO DECK STEAM LINE LEAKS PRIOR TO NEXT U.S. PORT CALL.
Condition: Unknown
Due 8 December 1995
Resolved 8 December 1995
Construction/Loadline
Issued 13 October 1995
Resolved
SUBMIT CLASS REPAIR PROPOSAL OF WASTED FOREPEAK TANK PORT SIDE LONGITUDNALSWHERE ATTACHED TO BREASTHOOKS "F" & "G".
Condition: Unknown
Due 20 October 1995
Resolved 26 October 1995
Fire Fighting
Issued 13 October 1995
Resolved
MAKE PERMANENT REPAIRS TO LEAKING FIRE MAIN VALVE AFT OF CARGO MANIFOLD.
Condition: Unknown
Due 20 October 1995
Resolved 26 October 1995
Fire Fighting
Issued 13 October 1995
Resolved
MAKE ADDITIONAL COPIES AND PROPERLY POST CORRECT FIRE CONTROL PLANS PRIOR TO CONDUCTING CARGO OPERATIONS.
Condition: Unknown
Due 20 October 1995
Resolved 26 October 1995
Electrical
Issued 28 July 1993
Resolved
PRIOR TO RETURNING TO U.S. WATERS PROVIDE CLASS SOCIETY REPORT ACCEPTING PERMANENT REPAIRS TO THE MAIN SWITCHBOARD SUPPLY CONTACTORS FOR THE EMERGENCY SWITCHBOARD AND EMERGENCY SWITCHBOARD RELAYS FOR MAIN AND EMERGENCY SUPPLY CONTACTORS. (RECOMMENDATION MO1 & MO2 ISSUED 27JUL93).
Condition: Unknown
Due 28 July 1993
Resolved 28 July 1993
Electrical
Issued 28 July 1993
Resolved
PRIOR TO RETURNING TO U.S. WATERS PROVIDE CLASS SOCIETY REPORT INDICATING RENEWAL AS ORIGINAL THE CIRCUIT BREAKER FOR THE NORMAL FEED TO THE EMERGENCY GENERATOR'S SWITCHBOARD LOCATED IN MAIN CONTROL ROOM. (SEE CLASS SOCIETY RECOMMENDATION ISSUED 28JUL93 - DELAWARE BAY).
Condition: Unknown
Due 28 July 1993
Resolved 28 July 1993
Construction/Loadline
Issued 11 September 1992
Resolved
UPON RETURNING TO U.S. WATERS PRESENT BALLAST TANKS IN GAS FREE CONDITION FOR INTERNAL EXAMINATION BY USCG MARINE INSPECTOR.
Condition: Unknown
Due 11 September 1992
Resolved 11 September 1992