Records from 1987 to 1992. Most recent: inspection, 24 August 1992.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 20
24 August 1992
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1262440
19 August 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 352858
6 November 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 340169
6 November 1990
Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1230099
9 May 1990
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1233845
4 May 1990
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1218738
20 April 1989
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 511923
6 December 1988
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1210118
28 November 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 327069
18 October 1988
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1197071
14 October 1988
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1198923
12 October 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 488920
16 November 1987
Administrative
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1023711
19 October 1987
Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1323126
9 October 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 503728
9 October 1987
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1320286
5 October 1987
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1016371
24 September 1987
Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1319393
18 September 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1005583
8 September 1987
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1008320
Lifesaving
Issued 24 August 1992
Resolved
RENEW PORTABLE OXYGEN METER.
Condition: Unknown
Due 24 September 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 24 August 1992
Resolved
REPAIR PORT ACCOMODATION LADDER TURNTABLE.
Condition: Unknown
Due 24 September 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 24 August 1992
Resolved
REPAIR STARBOARD ANCHOR CHAIN CATS PAW HANDLE.
Condition: Unknown
Due 24 September 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 6 November 1990
Resolved
VESSEL HAD 55 gal DRUMS OF KEROSENE, EMPTY 55 gal DRUMS, AND A FLEXABLE HOSE RUNING FROM A 55 gal DURM TO THE HYDRAULIC TANK BELOW DECK THIS IS IN VIOLATION OF 33CFR160.109(a)(1).
Condition: Unknown
Due 27 August 1992
Resolved 27 August 1992
Documentation
Issued 6 November 1990
Resolved
VESSELS OIL TRANSFER PROCEDURES DID NOT CONTAIN ALL THE INFORMATION REQUIRED BY 33CFR155.750.
Condition: Unknown
Due 27 August 1992
Resolved 27 August 1992
Engineering
Issued 6 November 1990
Resolved
VESSELS OILY WATER SEPERATOR ALARM WAS INOPERTIVE, THIS IS IN VIOLATION OF 33CFR151.10(b)(4).
Condition: Unknown
Due 27 August 1992
Resolved 27 August 1992
Navigation
Issued 6 November 1990
Resolved
VESSELS B.A. LIST OF LIGHTS & COAST PILOT W/ SUPP # 8s WERE NOT CORRECTED TO DATE AS REQUIRED BY 33CFR164.33(b).
Condition: Unknown
Due 27 August 1992
Resolved 27 August 1992
Navigation
Issued 6 November 1990
Resolved
VESSELS B.A. CHARTS 1063, & 1082 WERE NOT CORRECTED TO DATE AS REQUIRED BY 33CFR164.33(b).
Condition: Unknown
Due 27 August 1992
Resolved 27 August 1992
Deck/Cargo
Issued 18 October 1988
Resolved
MAKE PERMANENT REPAIRS TO AND DEMONSTRATE OPERATION OF CLOSED GAUGING HIGH LEVEL AND LOW LEVEL ALARMS TO THE SATISFACTION OF THE COGNIZANT [name withheld] CARGO REQUIRING CLOSED OR RESTRICTED GAUGING OR HIGH LEVEL OR LOW LEVEL ALARMS. BUT IN NO CASE LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 18 October 1988
Resolved 18 October 1988
Documentation
Issued 5 October 1987
Resolved
SUBMIT NEW IMO CERTIFICATE OF FITNESS TO COMDT (G-MTH-1) AND OBTAIN A NEW CARGOES AND RESTRICTIONS LIST.
Condition: Unknown
Due 5 October 1987
Resolved 5 October 1987
Unknown
Issued 5 October 1987
Resolved
PROVIDE SELF CONTAINED BREATHING APPARATUS WITH SPARE CHARGES AS REQUIRED BY IMO CHEMICAL CODE SECTION 3.16.6 PRIOR TO CARRYING TOXIC CARGOES WHICH REFERENCE 4.9 IN COLUMN K OF CHAPTER VI OF THE IMO CHEMICAL CODE. TO BE COMPLETED CARRYING REF CARGOES BUT NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 5 October 1987
Resolved 5 October 1987
Unknown
Issued 5 October 1987
Resolved
SERVICE ALL EMERGENCY ESCAPE BREATHING APPARATUS REQUIRED BY IMO CHEMICAL CODE SECTION 3.16.10.
Condition: Unknown
Due 5 October 1987
Resolved 5 October 1987