← All vessels
MUNDOGAS ATLANTIC
MUNDOGAS ATLANTIC is a 1969 tank ship. The Coast Guard has recorded 34 inspections since 1984, most recently in April 1998, along with 64 deficiencies and 1 operational control.
Records from 1984 to 1998. Most recent: inspection, 13 April 1998.
- Built
- 1969
- Last inspected
- 13 April 1998
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 64 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
6916158 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ELJL4
51634
Flag
LIBERIA
—
Maury page id
psix-51634
Inspections, by type
…with no type recorded23
Years with a record
9 calendar years (1984–1998)
The 34 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it4828 - Regulatory (Subpart C or D), Net Ton
25507 - Displacement, Ton
17018 - Dead Weight, Ton
16093 - Regulatory (Subpart C or D), Gross Ton
25507 - Displacement, Ton
17018 - Dead Weight, Ton
16093 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 34
13 April 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 414778
23 January 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 412022
23 January 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 781743
26 October 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 502881
23 September 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 521105
16 May 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 403722
25 February 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 400824
20 March 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 389194
17 February 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 387912
20 January 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 387107
20 January 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1185589
8 August 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 537582
8 August 1994
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 861491
9 March 1994
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 854333
25 October 1993
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1148672
8 October 1993
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1133761
1 March 1993
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 837378
28 February 1993
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 356589
2 December 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 672513
27 November 1992
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 437677
27 November 1992
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 830317
23 November 1992
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 826883
21 November 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 170802
5 November 1992
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 354290
5 November 1992
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 951567
13 June 1992
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 959344
22 October 1991
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 934138
1 August 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 903372
9 July 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 338212
9 July 1990
MARPOL Annex II Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 930656
13 April 1990
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 925948
4 April 1990
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 904172
10 October 1984
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 494910
29 August 1984
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 482433
Deficiency record · 64
Accommodation/Occupational Safety
Issued 23 January 1998
Resolved
REPAIR EMERGENCY ESCAPE DOOR IN HOSPITAL TO SATISFACTION OF CLASS.
Accommodation/Occupational Safety
Issued 23 January 1998
Resolved
CLEAN VENT GRILL ABOVE OVEN IN THE GALLEY. GRILL COVERED WITH GREASE TO SATISFACTION OF CLASS.
Accommodation/Occupational Safety
Issued 23 January 1998
Resolved
REPAIR EMERGENCY ESCAPE HANDLE IN RICE STOREGE LOCKER TO SATISFACTION OF CLASS.
Construction/Loadline
Issued 23 January 1998
Resolved
PROVIDE TWO (2) WING NUTS FOR VENTILATION CLOSURE FOR THE SKYLIGHT HATCH FOR ENGINE SPACE AFT OF VESSEL TO SATISFACTION OF CLASS.
Lifesaving
Issued 23 January 1998
Resolved
REPAIR LIGHT FOR LIFEBUOY PORT AMIDSHIP TO SASTIFACTION OF CLASS.
Lifesaving
Issued 23 January 1998
Resolved
PROVIDE SOLAS APPROVED LIGHTS FOR LIFEJACKETS IN FOC'SLE TO SATISFACTION OFCLASS.
Fire Fighting
Issued 23 January 1998
Resolved
IDENTIFY THE INTERNATIONAL SHORE CONNECTION IN THE FIRE CONTROL PLAN TO SATISFACTION OF CLASS.
Electrical
Issued 23 January 1998
Resolved
PROOF OPENINGS ON PORT AND STARBOARD SIDE ELECTRIC MOTOR ROOM ARE GAS TIGHTTO SATISFACTION OF CLASS.
Electrical
Issued 23 January 1998
Resolved
REPAIR OR REMOVE LIGHT FIXTURE ABOVE THE BEDS IN THE HOSPITAL TO SATISFACTION OF CLASS.
Lifesaving
Issued 23 January 1998
Resolved
MAKE PORT LIFEBOAT FRONT END BE SUPPORTED BY CRADDLE TO RELIEVE THE STRESS TO DAVID CABLES TO SATISFACTION OF CLASS.
Electrical
Issued 23 January 1998
Resolved
RENEW NON-CONDUCTIVE HAND RAILS IN SHIP SERVICE GENERATOR SWITHBOARDS TO SATISFACTION OF CLASS.
Fire Fighting
Issued 23 January 1998
Resolved
REPLACE NON-WORKING GAUGES PORT SIDE INBOARD FIRE PUMP TO SATISFACTION OF CLASS.
Navigation
Issued 16 May 1997
Resolved
MAKE PERMANENT REPAIRS TO RADAR.
Construction/Loadline
Issued 16 May 1997
Resolved
MAKE PERMANENT REPAIRS TO OVERHEAD PLATE IN CARGO MOTOR ROOM, PORT PIPEWAY.
Construction/Loadline
Issued 16 May 1997
Resolved
MAKE OUTER DOOR TO CARGO MOTOR ROOM FUME TIGHT.
Engineering
Issued 25 February 1997
Resolved
MAKE REPAIR TO HOLED INERT GAS AIR DRYING UNIT TO THE SATISFACTION OF CLASS.
Fire Fighting
Issued 25 February 1997
Resolved
PROVE INTEGRITY OF LIQUID PRESSURE RELIEF VALVES AND PIPE SYSTEM FOR LIQUIDPRESSURE RELIF TO THE SATISFACTION OF CLASS. AS OF 27MAR97, DISCREPANCY STILL OUTSTANDING, SINCE IT NEEDS HOT WORK WHICH WILL BE DONE DURING DRYDOCK.
Fire Fighting
Issued 25 February 1997
Resolved
RENEW CROSS OVER VALVE BETWEEN #2 AND #3 CARGO TANK WHERE WASTED TO THE SATISFACTION OF CLASS.
Construction/Loadline
Issued 25 February 1997
Resolved
RENEW BULKHEAD SEAL IN FORWARD COMPRESSOR ROOM BY VENT DUCT TO THE SATISFACTION OF CLASS.
Accommodation/Occupational Safety
Issued 25 February 1997
Resolved
REMOVE VARIOUS STEEL PIPES AND BARS FROM OBSTRUCTING VENTILATION ACCESS BY AFT ENGINE ROOM ENTRANCE ON MAIN DECK.
Lifesaving
Issued 25 February 1997
Resolved
PROVIDE WEAKLINK FOR BOTH 20 MAN LIFE RAFTS PRIOR TO DEPARTING PORT.
Deck/Cargo
Issued 25 February 1997
Resolved
RENEW #6 COMPRESSOR SEAL OILER TO THE SATISFACTION OF CLASS.
Lifesaving
Issued 25 February 1997
Resolved
REPAIR DAVIT LIMITER SWITCH FOR BOTH LIFEBOATS DAVIT TO THE SATISFACTION OFCLASS.
Deck/Cargo
Issued 25 February 1997
Resolved
REPAIR CARGO HEATER VALVE PACKING GLAND PORT SIDE MAINDECK BY SAFETY HAND RAIL TO THE SATISFACTION OF CLASS.
Engineering
Issued 25 February 1997
Resolved
PROVE PROPER OPERATION OF THE INERT GAS SYSTEM ALARMS AND CONTROL TO THE SATISFACTION OF CLASS.
Electrical
Issued 25 February 1997
Resolved
MAKE WARNING LIGHT INSIDE OF AIRLOCK TO MOTOR ROOM OPERABLE TO THE SATISFACTION OF CLASS.
Fire Fighting
Issued 25 February 1997
Resolved
PROVE OPERATION OF GAS DETECTION SYSTEM TO THE SATISFACTION OF CLASS.
Fire Fighting
Issued 25 February 1997
Resolved
PROVIDE CLEAN FILTER TO SAMPLE POINTS TO THE GAS DETECTION SYSTEM TO THE SATISFACTION OF CLASS.
Fire Fighting
Issued 25 February 1997
Resolved
PROVE GAS DETECTION SAMPLE POINTS ARE IN THE PROPER LOCATIONS FOR THE DENSITY OF CARGOES CARRIED TO THE SATISFACTION OF CLASS.
Deck/Cargo
Issued 20 January 1996
Resolved
Test and prove proper operation of interbarrier relief valves.
Deck/Cargo
Issued 20 January 1996
Resolved
Test and prove proper operation of quick closing valves at starboard cargo manifold.
Electrical
Issued 20 January 1996
Resolved
Procure and install light covers throughout vessel.
Navigation
Issued 20 January 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Engineering
Issued 20 January 1996
Resolved
Renew flame screens on both forward fuel oil bunker vents.
Fire Fighting
Issued 20 January 1996
Resolved
Prove proper operation of fire damper on aft paint roon vent, foreward maindeck, stbd side.
Deck/Cargo
Issued 20 January 1996
Resolved
Prove proper operation of air lock to foc'sle spaces.
Deck/Cargo
Issued 20 January 1996
Resolved
Provide documentation of cargo piping material condition test.
Construction/Loadline
Issued 20 January 1996
Resolved
Prove proper operation of all remote valves to eductor system.
Fire Fighting
Issued 20 January 1996
Resolved
Install nozzle on deck spray system on on port side of compresser house.
Engineering
Issued 20 January 1996
Resolved
NO MECHANICAL MEANS FOR CLOSING DRAINS AND/OR SCUPPERS _x001C_ 33C.F.R.155.310(a)(3)_x001C_
Engineering
Issued 20 January 1996
Resolved
OIL TRANSFER PROCEDURES INCOMPLETE. _x001C_ 33 C.F.R. 155.750
Fire Fighting
Issued 20 January 1996
Resolved
FIRE STATIONS MISSING NECESSARY TOOLS._x001C_ SOLAS 60,34.10-10(d)
Navigation
Issued 20 January 1996
Resolved
9 DEGREE VARIATION IN GYROCOMPASS AND AFT STEERING REPEATER._x001C_
Deck/Cargo
Issued 20 January 1996
Resolved
Prove proper operation of Inert Gas Generator.
Construction/Loadline
Issued 20 January 1996
Resolved
Provide Class survey of hull in way of wind water area, port side.
Fire Fighting
Issued 20 January 1996
Resolved
Renew firemain piping where soft patched at aft of compressor house.
Fire Fighting
Issued 20 January 1996
Resolved
Provide service report for fixed dry chemical deck fire extinguishing systems.
Fire Fighting
Issued 20 January 1996
Resolved
Prove proper operation of flashlights to emergency outfits.
Accommodation/Occupational Safety
Issued 20 January 1996
Resolved
Renew planks on catwalks where rotted.
Construction/Loadline
Issued 8 October 1993
Resolved
MAKE REPAIRS TO PORT AND STARBOARD BALLAST TANKS 1, 2, 3 & 4 AND FOREPEAK TANK AS RECOMMENDED BY DNV SURVEY REPORT DATED 25AUG93. REPAIRS TO BE COMPLETED PRIOR TO RETURNING TO U. S. WATERS AFTER 31JAN94.
Deck/Cargo
Issued 8 October 1993
Resolved
MAINTAIN CONTINUOUS MONITOR OF OXYGEN CONCENTRATION BY PORTABLE METER DURING OPERATIONS REQUIRING IGS IN U. S. WATERS UNTIL OXYGEN ANALYSER AND HIGH OXYGEN CONTENT ALARM IS REPAIRED. MAKE PERMANENT REPAIRS TO SAME PRIOR TO NEXT U. S. VOYAGE.
Engineering
Issued 27 November 1992
Resolved
PROVE SATISFACTORY OPERATION OF THE OILY WATER SEPERATOR.
Deck/Cargo
Issued 27 November 1992
Resolved
PROVIDE WRITTEN CERTIFICATION FROM CLASS SOCIETY THAT CARGO RELIEF VALVES ARE WITHIN DESIGN SPECIFICATION AND THEN TO BE RESEALED. 2 ON TANK #1 AND 1 ON TANK #3.
Deck/Cargo
Issued 27 November 1992
Resolved
REPAIR WATER LEAK ON SHELL OF IGS SCRUBBER.
Engineering
Issued 27 November 1992
Resolved
MAKE PERMANENT REPAIRS TO #3 GENERATOR TURBOCHARGER COOLING WATER LINE.
Construction/Loadline
Issued 27 November 1992
Resolved
CLASS SOCIETY TO VERIFY SOURCE OF OIL INFILTRATION INTO BALLAST SYSTEM HAS BEEN CORRECTED.
Accommodation/Occupational Safety
Issued 27 November 1992
Resolved
CLASS SOCIETY TO PROVIDE WRITTEN DOCUMENTATION CERTIFYING THAT ENGINEROOM VENTILATION EXHAUST SYSTEM AND FAN SERVICING GENERATOR FLAT ARE OIL FREE AND SAFE TO OPERATE.
Deck/Cargo
Issued 5 November 1992
Resolved
LEAK UNDER TOP OF INNERT GAS AIR DRIER MUST BE REPAIRED.
Fire Fighting
Issued 5 November 1992
Resolved
BRACKETS FOR NITROGEN BOTTLE ON AFTERMOST MAIN DECK DC STATION NEED TO BE REPAIRED.
Deck/Cargo
Issued 5 November 1992
Resolved
REPAIR MINOR LEAK IN SEA WATER LINE TO INNERT GAS SCRUBBER.
Documentation
Issued 9 July 1990
Resolved
VESSEL FAILED TO HAVE A VALID SUBCHAPTER "O" ENDORSEMENT. THE SUBCHAPTER_x001C_ "O" ENDORSEMENT ONBOARD EXPIRED ON 31 MAY 1990.
Documentation
Issued 4 April 1990
Resolved
SUBMIT NEW CERTIFICATE OF FITNESS TO CG HDQTRS FOR ISSUANCE OF NEW SOE.
Fire Fighting
Issued 4 April 1990
Resolved
MAINTAIN TEMPORARY REPAIR TO DECK SPRAY SYSTEM PIPING JUST FORWARD OF HOUSEPERMANENT REPAIR TO BE MADE PRIOR TO NEXT ENTRY U.S. WATERS.
Lifesaving
Issued 4 April 1990
Resolved
INSTALL WEAK LINK IN LIFERAFT PAINTERS PRIOR TO LEAVING PORT.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.