Records from 1984 to 1997. Most recent: inspection, 14 January 1997.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 10
14 January 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 399107
14 January 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1100307
14 February 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 375643
11 February 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 375178
11 February 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 842167
20 May 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 470280
25 July 1992
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 946526
2 October 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1250085
29 May 1990
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 921383
21 September 1984
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 298332
Lifesaving
Issued 14 January 1997
Resolved
PROFESSIONNALY SERVICE EMERGENCY ESCAPE BREATHING DEVICES.
Condition: Unknown
Due 28 January 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 14 January 1997
Resolved
REPAIR EMERGENCY SHUTDOWN (LOADING) VALVE FOR THE #1 CARGO TANK PRIOR TO LOADING CARGO IN TANK.
Condition: Unknown
Due 14 January 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 11 February 1995
Resolved
PROFESSIONALLY SERVICE SELF-CONTAINED BREATHING APPARTUS (SCBA'S) AND PROVIDE DOCUMENTATION TO U.S. COAST GUARD.
Condition: Unknown
Due 14 February 1995
Resolved 27 February 1995
Fire Fighting
Issued 11 February 1995
Resolved
DEMONSTRATE PROPER OPERATION OF DECK WATER SPRAY PRIOR TO CARGO OPERATIONS.
Condition: Unknown
Due 11 February 1995
Resolved 27 February 1995
Deck/Cargo
Issued 11 February 1995
Resolved
DEMONSTRATE PROPER OPERATION OF AUDIBLE AND VISUAL ALARMS FOR OXYGEN SENSOROF MORE THAN 5% BY VOLUME ON THE INERT GAS GENERATOR.
Condition: Unknown
Due 14 February 1995
Resolved 27 February 1995
Documentation
Issued 25 July 1992
Resolved
UPDATE SECTION 3.1 OF IOPP CERT FORM A WITH TANK IDENTIFICATION AND TANK LOCATION INFORMATION AND SECTION 3.2.1 OF IOPP CERT FORM A WITH INCINERATORCAPACITY. INFORMATION TO BE ENTERED AND CERTIFIED BY REPRESENTATIVE OF CLASSIFICATION SOCIETY. POVIDE CERT COPY TO MSO NOLA PRIOR TO DEPT FM NOLA
Condition: Unknown
Due 30 July 1992
Resolved 7 August 1992
Deck/Cargo
Issued 2 October 1991
Resolved
MARK STARBOARD CARGO MANIFOLD VALVES TO INDICATE OPEN AND CLOSED POSITIONS PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 2 October 1991
Resolved 2 October 1991
Engineering
Issued 2 October 1991
Resolved
PROVIDE MECHANICAL MEANS OF CLOSURE FOR ALL BUNKER OIL FIXED CONTAINMENT PRIOR TO RETURN TO U.S. WATERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 October 1991
Resolved 2 October 1991
Documentation
Issued 2 October 1991
Resolved
UPDATE TRANSFER PROCEDURES TO INCLUDE TELEPHONE NUMBER FOR COAST GUARD IN THE EVENT OF SPILL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 October 1991
Resolved 2 October 1991
Engineering
Issued 2 October 1991
Resolved
MAKE PERMANENT REPAIRS TO FIXED CONTAINMENT FOR DIESEL FUEL VENTS LOCATED ON PORT AND STARBOARD SIDE AFT ON MAIN DECK PRIOR TO RETURN TO U.S. WATERS._x001C_ _x001C_
Condition: Unknown
Due 2 October 1991
Resolved 2 October 1991
Deck/Cargo
Issued 2 October 1991
Resolved
MAKE PERMANENT REPAIRS TO TEMPORARY PATCH REPAIRS IN THE INERT GAS GENERATOR EXHAUST PIPING AT TOP OF GENERATOR PRIOR TO RETURN TO U.S. WATERS. _x001C_
Condition: Unknown
Due 2 October 1991
Resolved 2 October 1991
Lifesaving
Issued 2 October 1991
Resolved
LABEL EMERGENCY SHOWER/EYE WASH STATION LOCATED ON PORT SIDE PRIOR TO RETURN TO U.S. WATERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 October 1991
Resolved 2 October 1991
Unknown
Issued 2 October 1991
Resolved
MAKE PERMANENT REPAIRS TO MARINE GROWTH PREVENTION SYSTEM PIPING AT THE S/WLOW SEA STRAINER ON STARBOARD SIDE FORWARD IN ENGINE ROOM PRIOR TO RETURN TO U.S. WATERS._x001C_ _x001C_
Condition: Unknown
Due 2 October 1991
Resolved 2 October 1991
Navigation
Issued 2 October 1991
Resolved
UPDATE CHARTS 12214, 12304, 12311, 12312 IN ACCORDANCE WITH CURRENT NOTICE TO MARINERS PRIOR TO DEPARTURE FROM THE PORT OF PHILADELPHIA._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 October 1991
Resolved 2 October 1991
Deck/Cargo
Issued 21 September 1984
Resolved
REPAIR OR REPLACE INFRA-RED ANALYZER OF THE MSA GAS DETECTOR SYSTEM. (1 OF 2 ANALYZERS)
Condition: Unknown
Due 21 September 1984
Resolved 21 September 1984
Electrical
Issued 21 September 1984
Resolved
REPLACE LOW CURRENT SWITCHES FOR VENT FANS IN THE ELECTRIC MOTOR ROOM WITH LOW PRESSURE CUTOUT SWITCHES.
Condition: Unknown
Due 21 September 1984
Resolved 21 September 1984
Construction/Loadline
Issued 21 September 1984
Resolved
REMOVE PAINT FROM GASKETS ON WATERTIGHT DOORS TO MOTOR ROOM,AND COMPRESSOR ROOM.
Condition: Unknown
Due 21 September 1984
Resolved 21 September 1984