MAURY USCG vessel records Sign in
← All vessels

BERGE ARROW

BERGE ARROW is a 1978 tank ship. The Coast Guard has recorded 13 inspections since 1987, most recently in February 2006, along with 8 deficiencies — 1 with no resolution recorded — and 3 operational controls.

Records from 1987 to 2006. Most recent: inspection, 10 February 2006.

Built
1978
Last inspected
10 February 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7420297 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
NORWAY
—
Maury page id
psix-51648

Inspections, by type

…with no type recorded4
…past their stated due date1
Years with a record 7 calendar years (1987–2006)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it13350 - Regulatory (Subpart C or D), Net Ton
13350 - Convention (Subpart B), Net Ton
48821 - Dead Weight, Ton
70529 - Displacement, Ton
44502 - Regulatory (Subpart C or D), Gross Ton
44502 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

10 February 2006 COC-GAS Renew · ISPS II Exam · Ballast Water Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2579928
29 September 2003 Administrative Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1916200
10 July 2003 Certificate of Compliance · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1842407
18 March 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1494399
21 February 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1488903
28 August 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 293311
28 August 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1071715
20 February 1998 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 413028
28 January 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 411859
28 January 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1118882
13 June 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 379287
13 June 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1187208
19 August 1987 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1005237

Deficiency record · 8

Construction/Loadline › Markings › Load Line Mark
Issued 10 February 2006 No resolution recorded
Port and starboard loadlines not painted in a contrasting color. Prior to 17Feb2006, master must provide attestation to MSU Galveston that loadlines were painted in accordance with the International LoadLine Convention.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 February 2006 — due date passed with no resolution recorded
Engineering › Steering Gear System › Pump
Issued 10 July 2003 Resolved
During op test of the steering gear the pump actuators, housing, shaft seals & many fittings leaking approx. 6 to 8 drops per second & spraying. Most of the leaks rectified & steering gear tested to satisfaction of Class. A Condition of Class issued for permanent repairs of remaining leaks. LEGACY COMPONENT DESC: Power Unit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2003
Resolved 10 February 2006
Resolution: Received class report attesting repaires and operational test was sat.
Engineering › Diesel Engine (auxiliary)
Issued 10 July 2003 Resolved
No.1 fuel oil injection pump high pressure jumper line on the No. 2 auxiliary diesel generator is leaking excessively. LEGACY COMPONENT DESC: Pump, High Pressure (fuel injection)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 July 2003
Resolution: Cheif engineer repaired and tested auxillary generator befor the inspection was complete. Test sat.
Fire Fighting › Combustible Materials
Issued 10 July 2003 Resolved
Engineroom machinery surfaces and containment area are covered with oil. Clean and remove oily waste to the satisfaction of the attending classification society. LEGACY COMPONENT DESC: Machinery Surfaces & Containment Areas
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2003
Resolved 29 September 2003
Resolution: Received class report from DNV satisfying requirement.
Pollution Prevention/Response › Prevention Equipment
Issued 10 July 2003 Resolved
Oily water separator system piping has been altered from original design. System piping has a rubber hose installed on manifold for bilges and bilge holding tank. Have class attest to proper piping design prior to use of the oily water separator in U.S. waters. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 July 2003
Resolved 29 September 2003
Resolution: Received class report from DNV satisfying requirement.
Lifesaving
Issued 28 January 1998 Resolved
Starboard lifeboat davit not ready for immediate use as per SOLAS 74 (amended) Reg III/19.2. Repair NLT 2FEB98.
Condition: Unknown
Due 20 February 1998
Resolved 20 February 1998
Lifesaving
Issued 13 June 1995 Resolved
NO DATE OF SERVICE ON HYDRO-STATIC RELEASE ON THE EPIRB._x001C_ SOLAS CHAPTER IV REGULATION 7.
Condition: Unknown
Due 29 January 1998
Resolved 29 January 1998
Deck/Cargo
Issued 13 June 1995 Resolved
*MI95022095*-REPAIR & PROVE PROPER OPERATION OF #1 & #2 PORT HIGH LEVEL CARGO TANK ALARMS AND HAVE CLASS SOCIETY REPORT TO COGNIZANT OFFICER IN CHARGE OF MARINE INSPECTION._x001C_ IMO-GAS CARRIER CODE; CHAPTER XIII-13.3
Condition: Unknown
Due 29 January 1998
Resolved 29 January 1998

Ownership record