MAURY USCG vessel records Sign in
← All vessels

BERGE EAGLE

BERGE EAGLE is a 1978 tank ship. The Coast Guard has recorded 24 inspections since 1987, most recently in December 2007, along with 16 deficiencies and 3 operational controls.

Records from 1987 to 2007. Most recent: operational control imposed, 14 December 2007.

Built
1978
Last inspected
14 December 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7420302 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
NORWAY
—
Maury page id
psix-51649

Inspections, by type

…with no type recorded11
Years with a record 9 calendar years (1987–2007)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it13350 - Regulatory (Subpart C or D), Net Ton
48996 - Dead Weight, Ton
44502 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

14 December 2007 MARPOL Annex I Examination · COC-GAS Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3115483
29 November 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1713006
24 April 2002 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1607711
24 April 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1609774
2 September 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 432438
2 September 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1118428
1 April 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 505877
21 January 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 399827
21 January 1997 Letter of Compliance (Initial/Renewal) · MARPOL Annex V Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1407814
9 April 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 714122
19 March 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 389111
5 November 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1367552
20 September 1995 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1184822
18 July 1995 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1185619
13 June 1995 Passenger/Freight Vessel Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1355290
4 January 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1165669
29 October 1994 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 371916
27 October 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1401941
16 November 1988 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 894128
23 August 1988 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1039250
15 August 1987 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1029924
2 August 1987 MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1006493
2 August 1987 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1337030
1 August 1987 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 494104

Deficiency record · 16

Fire Fighting › Emergency Fire Pumps › Power Source
Issued 14 December 2007 Resolved
Inspector witnessed fuel oil leak from fuel filter housing on engine driven emergency fire pump
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2007
Resolution: Received class report attesting to proper repairs and full operation of the emergency fire pump.
Engineering
Issued 24 April 2002 Resolved
Prior to use in U.S. waters, provide USCG or IMO certification for the sewage system. All valves for sewage overboard shall be secured.
Due 24 April 2002
Resolved 27 April 2002
Resolution: Rcvd fax of USCG approval letter from vessel via Hamworthy.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 April 2002 Resolved
Repair electrical inverter for emergency power to navigation lights. Vessel is restricted to daylight transit only until corrected.
Due 24 April 2002
Resolved 27 April 2002
Resolution: New inverter delivered to vessel and installed by crew.
Navigation
Issued 19 March 1996 Resolved
COAST GUARD NAVIGATION RULES NOT ON BOARD.
Condition: Unknown
Due 28 July 1996
Resolved 28 July 1996
Fire Fighting
Issued 5 November 1995 Resolved
MAKE REPAIRS TO 3" FIREMAIN SPRINKLER LINE LOCATED FWD STBD CORNER OF CARGOCONTROL ROOM HOUSE. CORRECT PRIOR TO NEXT U.S. PORT._x001C_ 8NOV95 RCVD FAX FM MASTER STATING PERMANENT REPAIRS WERE MADE. DID NOT CLEAR AS VSL ALREADY DEPARTED PORT.
Condition: Unknown
Due 5 November 1995
Resolved 5 November 1995
Engineering
Issued 13 June 1995 Resolved
INSTALL REQUIRED CONTAINMENT FOR F.O. TANK NO. 26 VENT (FWD). INSTALLATIONTO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI AND ATTENDING MARINE INSPECTOR PRIOR TO ARRIVAL AT THE NEXT U.S. PORT.
Condition: Unknown
Due 13 June 1995
Resolved 13 June 1995
Deck/Cargo
Issued 27 October 1994 Resolved
REPAIR/RECONNECT SAFETY VALVE ESCAPE PIPING IN CARGO PUMP ROOM OFF FREON CONDENSER (3) LOCATIONS.
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Unknown
Issued 16 November 1988 Resolved
PROVE PROPER OPERATION OF AIRLOCK SYSTEM TO AN ATTENDING CG INSPECTOR PRIORTO DISCHARGE IN A U. S. PORT AFTER 26AUG88.
Condition: Unknown
Due 16 November 1988
Resolved 16 November 1988
Unknown
Issued 23 August 1988 Resolved
DURING CARGO TRANSFER POST A WATCH MAN AT ENTRANCE OF MOTOR/CONTROL SPACE DUE TO AIRLOCKS NOT DEENERGIZING ALL ELECTRICAL EQUIPMENT.
Condition: Unknown
Due 23 August 1988
Resolved 23 August 1988
Unknown
Issued 23 August 1988 Resolved
PRIOR TO DISCHARGE IN A U.S. PORT AFTER 26AUG88. PROVE PROPER OPERATION OF AIRLOCK SYSTEM TO AN ATTENDING CG INSPECTOR BUT NOT LATER THAN 25OCT88.
Condition: Unknown
Due 23 August 1988
Resolved 23 August 1988
Deck/Cargo
Issued 2 August 1987 Resolved
PROVIDE PROPER CALIBRATION GAS FOR GAS DETECTION SYSTEM, AND PROVE PROPER OPERATION OF THIS SYSTEM.
Condition: Unknown
Due 2 August 1987
Resolved 2 August 1987
Engineering
Issued 2 August 1987 Resolved
PROVE PROPER OPERATION OF THE OILY WATER SEPARATOR.
Condition: Unknown
Due 2 August 1987
Resolved 2 August 1987
Deck/Cargo
Issued 2 August 1987 Resolved
MAKE PERMANENT REPAIRS TO BUNKERING STATION CONTAINMENT. STARBOARD SIDE.
Condition: Unknown
Due 2 August 1987
Resolved 2 August 1987
Documentation
Issued 2 August 1987 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 2 August 1987
Resolved 2 August 1987
Lifesaving
Issued 2 August 1987 Resolved
PROVIDE PROPER WEAK LINKS ON ALL INFLATABLE LIFERAFT PAINTERS AND PLACE HYDRALIC RELEASES FOR SAME UNDER PROPER TENSION.
Condition: Unknown
Due 2 August 1987
Resolved 2 August 1987
Fire Fighting
Issued 2 August 1987 Resolved
PROVE PROPER OPERATION OF DECK SPRAY SYSTEM AMIDSHIPS.
Condition: Unknown
Due 2 August 1987
Resolved 2 August 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.