Records from 1986 to 1994. Most recent: inspection, 24 December 1994.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 14
24 December 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1158081
6 July 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 700459
1 July 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1394145
28 April 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1169915
22 April 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1167143
8 April 1994
Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1415961
7 April 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 365821
2 December 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1241589
2 November 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1246163
17 July 1990
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1220895
12 July 1990
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987085
21 June 1990
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 931928
17 January 1987
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 478223
8 December 1986
Certificate of Compliance
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1331286
Lifesaving
Issued 1 July 1994
Resolved
Clean oil residue from tank tops in the tween deck space. To be completed prior to cargo operations at next U.S. Port.
Condition: Unknown
Due 1 July 1994
Resolved 1 July 1994
Deck/Cargo
Issued 1 July 1994
Resolved
Porvide span gas for calibrating the portable explosive gas meters as per BCH Code 3.11.1. To be completed prior to cargo operations at next U.S. Port.
Condition: Unknown
Due 1 July 1994
Resolved 1 July 1994
Deck/Cargo
Issued 1 July 1994
Resolved
Provide documentation that vessel's Cargo Discharge Monitor is set to 30 liters per nautical mile as required by MARPOL 73/78 Chapter II Regulation 9. To be completed prior to cargo operations at next U.S. Port.
Condition: Unknown
Due 1 July 1994
Resolved 1 July 1994
Deck/Cargo
Issued 1 July 1994
Resolved
Provide current toxic gas detection tubes for cargoes carried as per BCH Code 3.11.1. To be completed prior to cargo operations at next U.S. Port.
Condition: Unknown
Due 1 July 1994
Resolved 1 July 1994
Documentation
Issued 1 July 1994
Resolved
Provide current copies of Parts 34, 35 and 153 Code of Federal Regulationsas per 46 CFR 153.905. To be completed prior to cargo operations at next U.S. Port.
Condition: Unknown
Due 1 July 1994
Resolved 1 July 1994
Deck/Cargo
Issued 1 July 1994
Resolved
Provide documentation on pressure/vacuum settings of cargo tank pressure/vacuum valves. To be completed prior to cargo operation at next U.S. Port.
Condition: Unknown
Due 1 July 1994
Resolved 1 July 1994
Deck/Cargo
Issued 8 April 1994
Resolved
Ensure portable cargo hose properly blanked off when not in use._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Deck/Cargo
Issued 8 April 1994
Resolved
Hydrostatically test portable cargo hose prior to use._x001C_
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Lifesaving
Issued 8 April 1994
Resolved
Ensure personnel use intrinsically safe portable radios prior to handling cargo at next U.S. port.
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Documentation
Issued 8 April 1994
Resolved
Submit application for certificate of compliance IAW 46 CFR 153.9 prior to handling subchapter "O" cargoes in U.S. port.
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Fire Fighting
Issued 8 April 1994
Resolved
Provide 3 additional firemans outfits IAW IMO dangerous chemical code chapter 14.2.1, for a total of 7 outfits, prior to entry in next U.S. port._x001C_ _x001C_
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Fire Fighting
Issued 8 April 1994
Resolved
Provide 2 hydrostatically tested and properly serviced air bottles, for a total of 14.
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Documentation
Issued 7 April 1994
Resolved
NO OIL TRANSFER PROCEDURES ON BOARD VESSEL. NO BUNKERING IN U.S. WATERS WITHOUT PROPER OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 6 July 1994
Resolved 6 July 1994
Engineering
Issued 7 April 1994
Resolved
NO MECHANICAL CLOSURE DEVICES AT FUEL BUNKER MANIFOLD CONTAINMENT. NO BUNKERING IN U.S. WATERS WITHOUT PROPER CLOSURE DEVICES.
Condition: Unknown
Due 6 July 1994
Resolved 6 July 1994
Documentation
Issued 7 April 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Documentation
Issued 7 April 1994
Resolved
OFFICERS LICENSES NOT ISSUED BY FLAG STATE. PROVIDE CERTIFICATE OF COMPETENCY PRIOR TO NEXT U.S. PORT BUT NO LATER THAN 08MAY94.
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Navigation
Issued 7 April 1994
Resolved
TIDE TABLES AND TIDAL CURRENT TABLES (BRITISH ADMIRALTY-1993) OUTDATED.
Condition: Unknown
Due 6 July 1994
Resolved 6 July 1994
Deck/Cargo
Issued 12 July 1990
Resolved
PROVIDE CARGO TEMPERATURE SENSORS AT CARGO TANK BOTTOMS AND PROVIDE REMOTE READOUTS IN ACCORDANCE WITH 46CFR153.440 & .908 PRIOR TO THE NEXT U.S. VOYAGE. VESSEL MAY NOT CARRY ANNEX II CARGOES REQUIRED TO MEET THESE PARTSIN U.S. WATERS UNTIL COMPLETED.
Condition: Unknown
Due 12 July 1990
Resolved 12 July 1990
Fire Fighting
Issued 12 July 1990
Resolved
EFFECT REPAIRS AND PROVE OPERATION OF MAIN FIRE PUMP AT NEXT U.S. PORTCALL.IN INTERIM, THE AUXILIARY FIRE PUMP (BUTTERWORTH) IS TO REMAIN LINED-UP ON THE FIRE MAIN.
Condition: Unknown
Due 12 July 1990
Resolved 12 July 1990