MAURY USCG vessel records Sign in
← All vessels

SPIRIT TRADER

SPIRIT TRADER is a 1975 tank ship. The Coast Guard has recorded 25 inspections since 1984, most recently in June 2004, along with 29 deficiencies and 2 operational controls.

Records from 1984 to 2004. Most recent: inspection, 16 June 2004.

Built
1975
Last inspected
16 June 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7412006 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
PANAMA
—
Maury page id
psix-51672

Inspections, by type

…with no type recorded15
Years with a record 12 calendar years (1984–2004)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it673 - Simplified, Net Ton
3485 - Dead Weight, Ton
4813 - Displacement, Ton
2246 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 25

16 June 2004 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2100062
13 November 2003 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1947302
12 August 2003 Ballast Water Examination · Certificate of Compliance
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1874844
9 August 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1872060
8 May 1999 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 428294
2 June 1997 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 404211
6 July 1996 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 392957
5 June 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 715765
3 June 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 391772
3 June 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1414654
19 September 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 382823
19 September 1995 MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1188940
9 October 1994 Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 863437
17 February 1994 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 364391
17 February 1994 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 451203
17 February 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1165290
3 November 1993 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 838431
23 October 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1443421
15 June 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 465981
4 December 1992 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 829141
15 May 1988 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1040306
29 June 1986 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 309828
29 June 1986 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1001451
30 July 1984 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 297219
22 July 1984 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 490474

Deficiency record · 29

Engineering › Diesel Engine (auxiliary)
Issued 12 August 2003 Resolved
The cooling water pump for the No. 2 generator has been disconnected from the system because of a leaking seal. Temporary piping is installed from the general service pump to No. 2 generator to provide cooling water. LEGACY COMPONENT DESC: Pump, Positive Displacement
Action required: 705 - Other - as specified
Due 26 August 2003
Resolved 13 November 2003
Resolution: Cleared by NYCMI.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 12 August 2003 Resolved
Cargo piping was not hydrostatically tested to 1.5 times MAWP (15 bar) annually. Vessel prohibited from transfer of oil or hazardous materials until test conducted and recorded. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 20 August 2003
Resolved 13 November 2003
Resolution: Cleared by NYCMI.
Pollution Prevention/Response › Prevention Equipment
Issued 12 August 2003 Resolved
The overfill alarm for cargo tank P3 is inoperable. Alarm remains lit when tank level is below set point (98%). LEGACY COMPONENT DESC: Overfill Devices
Action required: 705 - Other - as specified
Due 26 August 2003
Resolved 13 November 2003
Resolution: Cleared by NYCMI.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 12 August 2003 Resolved
Vessel does not have any span gas or drager tubes for portable detection meters on board. Received invoice for span gas on 8/13/03. LEGACY COMPONENT DESC: Combustible Gas Indicator
Due 19 August 2003
Resolved 13 August 2003
Resolution: Received proper documentation satisfying requirement.
Navigation
Issued 3 June 1996 Resolved
The T/V SPIRIT TRADERwas in violation of 33 CFR 164.33(a)(2)(i) when the Coast Pilot onboard was not corrected to the latest Notice to Mariners.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Fire Fighting
Issued 3 June 1996 Resolved
Make repairs to the fire main located above the Masters cabin, and [name withheld] cabin to the satisfaction of the Class Society Surveyor. Class Surveyor approved temporary repairs to the fire main.
Condition: Unknown
Due 3 July 1996
Resolved 5 June 1996
Deck/Cargo
Issued 3 June 1996 Resolved
Provide Draeger tubes sufficient for all the commodities carried as required by BCH Code, reg 3.1.1.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Documentation
Issued 17 February 1994 Resolved
CARGO OIL TRANSFER PROCEDURES INCOMPLETE.
Condition: Unknown
Due 11 October 1994
Resolved 11 October 1994
Deck/Cargo
Issued 17 February 1994 Resolved
BLIND FLANGES ON VESSEL'S CARGO MANIFOLDS CONNECTED WITH ONLY TWO BOLTS.
Condition: Unknown
Due 2 March 1994
Resolved 2 March 1994
Engineering
Issued 17 February 1994 Resolved
INSTALL PERMANENT 0.5 BBL CAPACITY OIL CONTAINMENT AT STBD WASTE OIL TANK VENT, STBD SLUDGE TANK VENT AND PORT FUEL OIL LEAK TANK VENT IN ACCORDANCE WITH TITLE 46 C.F.R. SECTION 155.320(a)(1)
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Engineering
Issued 17 February 1994 Resolved
RENEW/REPLACE THE STBD AFT FUEL TANK VENT FLAME SCREENS.
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Electrical
Issued 17 February 1994 Resolved
PROVIDE A PROPER ELECTRICALLY BONDED LIGHT IN WAY OF THE PORT ENTRANCE TO THE TWEEN DECK.
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Accommodation/Occupational Safety
Issued 17 February 1994 Resolved
PROPERLY STOW DECK STORES AND PAINTS IN APPROVED LOCATIONS.
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Deck/Cargo
Issued 17 February 1994 Resolved
TEST AND MARK CARGO HOSES IN ACCORCANDE WITH TITLE 46 C.F.R. SECTION 153.940(b)
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Documentation
Issued 17 February 1994 Resolved
HAVE ON BOARD AVAILABLE FOR INSPECTION THE CARGO VISCOSITY AND MELTING POINT INFORMATION REQUIRED BY TITLE 46 C.F.R. SECTION 153.908(a)&(b) PRIOR TO CARRYING CARGOES LISTED IN TABLE 1 OF PART 153 WHICH REFER TO THAT SECTION.
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Engineering
Issued 17 February 1994 Resolved
PROVIDE HAND WHEELS WHERE MISSING FROM DECK STEAM HEATING SYSTEM.
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Documentation
Issued 17 February 1994 Resolved
PROVIDE UPDATED VESSEL RESPONSE PLAN ADDRESSING ALL PORTS IN THE SAN JUAN COTP ZONE PRIOR TO CARRYING OIL IN THE SAN JUAN ZONE.
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Documentation
Issued 17 February 1994 Resolved
PROVIDE A COPY OF THE LAST DRYDOCKING SURVEY REPORT AT NEXT U.S. PORT._x001C_
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Fire Fighting
Issued 17 February 1994 Resolved
PROVIDE 5 SPARE BOTTLES FOR THE EACH SCBA OUTFIT IN ACCORDANCE WITH TITLE 46 C.F.R. SECTION 153.214(b)(1).
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Fire Fighting
Issued 17 February 1994 Resolved
UPDATE VESSEL'S FIRE CONTROL PLAN TO SHOW LOCATION OF EMERGENCY EQUIPMENT.
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Lifesaving
Issued 17 February 1994 Resolved
REMOVE OBSTRUCTIONS FROM IN FRONT OF FIRE STATION #7 PRIOR TO CARGO OPERATIONS.
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Construction/Loadline
Issued 17 February 1994 Resolved
RENEW/REPAIR LADDER TREADS TO LADDER LOCATED AT STERN BETWEEN OFFICER'S DECK AND BRIDGE DECK.
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Deck/Cargo
Issued 23 October 1993 Resolved
PRIOR TO CARRYING A CARGO LISTED IN 46CFR153 TABLE I IN US WATERS WHICH REQUIRES A CLOSED GAUGING SYSTEM, DEMONSTRATE THE OPERATION OF THE CLOSED GAUGING SYSTEM.
Condition: Unknown
Due 23 October 1993
Resolved 23 October 1993
Engineering
Issued 4 December 1992 Resolved
INSTALL CONTAINMENT PLUG IN FUEL OIL DEEP TANK FORWARD.
Condition: Unknown
Due 4 December 1992
Resolved 4 December 1992
Deck/Cargo
Issued 4 December 1992 Resolved
ALL CARGO VENT SCREENS REQUIRE REPLACEMENT.
Condition: Unknown
Due 4 December 1992
Resolved 4 December 1992
Deck/Cargo
Issued 4 December 1992 Resolved
MAKE NECESSARY REPAIR TO CARGO GUAGING SYSTEM.
Condition: Unknown
Due 4 December 1992
Resolved 4 December 1992
Deck/Cargo
Issued 4 December 1992 Resolved
REPAIR BROKEN CARGO VENT PIPE SUPPORT BRACKET MIDSHIP.
Condition: Unknown
Due 4 December 1992
Resolved 4 December 1992
Deck/Cargo
Issued 30 July 1984 Resolved
HI-LEVEL ALARM INOPERATIVE DUE TO COMPUTER FAILURE.
Condition: Unknown
Due 16 December 1992
Resolved 16 December 1992
Deck/Cargo
Issued 30 July 1984 Resolved
VESSEL GUAGING INOPERATIVE DUE COMPUTER FAILURE.
Condition: Unknown
Due 16 December 1992
Resolved 16 December 1992

Ownership record