MAURY USCG vessel records Sign in
← All vessels

RELCHEM ARJUN

RELCHEM ARJUN is a 1971 tank ship. The Coast Guard has recorded 35 inspections since 1984, most recently in December 1992, along with 37 deficiencies.

Records from 1984 to 1992. Most recent: inspection, 2 December 1992.

Built
1971
Last inspected
2 December 1992
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7043348 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
ARGENTINA
—
Maury page id
psix-51688

Inspections, by type

…with no type recorded26
Years with a record 9 calendar years (1984–1992)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 34 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it10463 - Simplified, Net Ton
24588 - Dead Weight, Ton
15007 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 35

2 December 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 447691
17 November 1992 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 827102
29 July 1992 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 947079
13 July 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 479762
24 February 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 646301
14 February 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1265992
9 February 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 97986
8 February 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 183846
22 November 1991 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1248593
16 February 1991 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 341995
19 October 1990 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1221903
30 July 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1246153
2 April 1990 Certificate of Compliance
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1217907
1 April 1990 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 336203
30 October 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 439873
26 April 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1350507
23 April 1989 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 503413
26 August 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 463185
25 August 1988 Administrative
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1347135
28 March 1988 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1298149
20 January 1988 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 450429
19 October 1987 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1015942
14 August 1987 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1337351
12 August 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 317781
12 August 1987 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1033401
22 May 1987 MARPOL Annex II Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1026727
20 February 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 483550
9 April 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301071
22 January 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1309145
21 January 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 998158
15 January 1986 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 501353
6 January 1986 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 306233
6 January 1986 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 989839
20 June 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 461592
1 June 1984 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1280484

Deficiency record · 37

Deck/Cargo
Issued 17 November 1992 Resolved
MAKE PERMANENT REPAIRS TO VENT LINE FOR #2 PORT CARGO TANK EXPANSION TRUNK,WHERE HOLED AND TEMP. REPAIRED WITH EXPOXY.
Condition: Unknown
Due 17 December 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 17 November 1992 Resolved
TIGHTEN BOLTS TO INBOARD PISTON HOUSING FOR ANCHOR WINDLAS.
Condition: Unknown
Due 17 November 1992
Resolved 17 November 1992
Deck/Cargo
Issued 17 November 1992 Resolved
MAKE PERMANENT REPAIRS TO PINHOLE IN #1 CENTER CARGO PIPING, FORWARD OF THEMANIFOLD, (IN WAY OF #4 CFS TRUNK)
Condition: Unknown
Due 17 December 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 29 July 1992 Resolved
REPAIR OR REPLACE NUMEROUS STEAM CARGO, BITTERWORTH, FIREMAIN, HYDRAULIC AND ELECTRICAL CONDUIT PIPING SUPPORTS IWO MAIN DECK.
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Construction/Loadline
Issued 29 July 1992 Resolved
REPAIR WASTED FORWARD BULKHEADS AND WATERTIGHT DOORS IWO OXYGEN AND ACETYLENE BOTTLE ROOMS AND IWO ACETYLENE BOTTLE ROOM LONG. CENTERLINE BULKHEAD FWD LOWER CORNER.
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Fire Fighting
Issued 29 July 1992 Resolved
REPAIR OR REPLACE MAIN DECK HYDRAULIC PIPING, LEAKING IWO 8C, 3C, 2S AND E PUMP ROOM.
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Deck/Cargo
Issued 29 July 1992 Resolved
REPAIR OR REPLACE WASTED CONTAINMENT IWO #4 AND #2 DECK TANKS.
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Electrical
Issued 29 July 1992 Resolved
REPAIR OR REPLACE WASTED ELECTRICAL CONDUIT AND JUNCTION BOXES ON MAIN DECK.
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Deck/Cargo
Issued 29 July 1992 Resolved
PROVIDE MECHANICAL SCUPPER PLUGS FOR MAIN DECK CONTAINMENT(CONCRETE USED PRESENTLY).
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Fire Fighting
Issued 29 July 1992 Resolved
FIREMAIN HOLED IN 4 LOCATIONS (ONE ON DECK, THREE IN ENGINEROOM IWO FIREPUMPS) AND SOFT PATCHED(IN ENGINEROOM). PROVE PROPER OPERATION AND INTACT CONDITION OF SAME._x001C_
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Deck/Cargo
Issued 29 July 1992 Resolved
PROVE PROPER OPERATION OF WING CARGO TANK HIGK LEVEL ALARMS IAW 46CFR 153.409(c).
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Deck/Cargo
Issued 29 July 1992 Resolved
REPAIR OR REPLACE WASTED CARGO PUMPROOM VENTS.
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Deck/Cargo
Issued 29 July 1992 Resolved
PROVE PROPER OPERATION OF CARGO TANK SUCTION VALVES VIA MAIN DECK REACH RODS(APPROX. 40% INOP- STUCK OPEN.
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Fire Fighting
Issued 29 July 1992 Resolved
PROVIDE CURRENTLY UPDATED E-FIRE PLAN SHOWING TRUE LOCATION OF ALL EMERGENCY EQUIPMENT.
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Fire Fighting
Issued 29 July 1992 Resolved
RECHARGE SCBA BOTTLES ABOARD.
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Navigation
Issued 29 July 1992 Resolved
PROVIDE TIME AND DISTANCE TO STOP INFORMATION FOR FULL AND 1/2 SPEEDS AND INCLUDE WITH BRIDGE MANEUVERING INFORMATION.
Condition: Unknown
Due 30 December 1992
Resolved 30 December 1992
Engineering
Issued 29 July 1992 Resolved
REPAIR OR REPLACE FORWARD FUEL OIL TRANSFER PUMP, LOCATED IN EMERGENCY FIREPUMP ROOM, WHICH WAS LEAKING BLACK OIL INTO BILGES.
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Fire Fighting
Issued 29 July 1992 Resolved
PUMPROOM VENT CLOSURES ON CARGO DECK INOPERATIVE. PROVE PROPER OPERATION OF PUMPROOM VENT CLOSURES.
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Construction/Loadline
Issued 29 July 1992 Resolved
DECK PLATING IWO 7CS AND 7S CARGO TANKS FORWARD FOUND TO BE VERY THIN. REPLACE OR PROVIDE GAUGING REPORT SHOWING ADEQUATE THICKNESS.
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Deck/Cargo
Issued 29 July 1992 Resolved
PROVE PROPER OPERATION OF PRESSURE AND VACUUM SIDE OF ALL PV VALVES (PRESSWEIGHT STUCK CLOSED, VACUUM SIDE STUCK OPEN).
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Construction/Loadline
Issued 29 July 1992 Resolved
TWO PLUGS, APPROX. 1" DIA. FOUND IN DECK PLATING IWO 2S & 1PRTS. MAKE PERM.REPAIRS OR PROVIDE GAUGING REPORT SHOWING ADEQUATE THICKNESS.
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Deck/Cargo
Issued 29 July 1992 Resolved
PROVIDE PROPER FLAME SCREENS FOR RESTRICTION GAUGING OPENING 9 OF 10 FLAME SCREENS AND HOLED OR NOT CONTINIOUS.
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Lifesaving
Issued 29 July 1992 Resolved
PUMPROOM GAS DECTECTION UNITS OUT OF CALIBRATION OR INOPERATIVE. NEED TO PROVE PROPER OPERATION OF SAME.
Condition: Unknown
Due 30 December 1992
Resolved 30 December 1992
Documentation
Issued 22 November 1991 Resolved
SUBMIT CURRENT IMO CERTIFICATE OF FITNESS TO THE COAST GUARD MARINE SAFETY CENTER, WASHINGTON, D.C., FOR REVIEW AND ISSUANCE OF NEW SUBCHAPTER "O" ENDORSEMENT.
Condition: Unknown
Due 22 November 1991
Resolved 22 November 1991
Unknown
Issued 16 February 1991 Resolved
JUST A TEST.
Condition: Unknown
Due 16 February 1991
Resolved 16 February 1991
Deck/Cargo
Issued 12 August 1987 Resolved
VESSEL'S CARGO DISCHARGE CONTAINMENT DOES NOT HAVE A MECHANICAL MEANS OF CLOSING THE DRAIN VALVE AS REQUIRED BY 33CFR155.310(A)(3).
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Navigation
Issued 12 August 1987 Resolved
VESSELS DID NOT HAVE AN OPERABLE, SECOND INDEPENDENT RADAR AS REQUIRED BY 33CFR164.37(A).
Condition: Unknown
Due 12 August 1987
Resolved 12 August 1987
Navigation
Issued 12 August 1987 Resolved
VESSEL ENTERED THE COTP PORT ARTHUR, TX. ZONE WITH ONLY ONE OPERABLE RADAR AND DID NOT REQUEST A DEVIATION FOR ENTERING THIS PORT AS REQUIRED BY 33CFR164.53(B).
Condition: Unknown
Due 13 September 1987
Resolved 12 August 1987
Electrical
Issued 12 August 1987 Resolved
VESSEL'S EMERGENCY GENERATOR SWITCHBOARD WAS INOPERATIVE THEREFORE IAW SOLAS '74.
Condition: Unknown
Due 13 September 1987
Resolved 12 August 1987
Navigation
Issued 12 August 1987 Resolved
VESSEL EMERGENCY STEERING GEAR ROOM HAD FLAMABLES STOWED INSIDE, ALSO EMERGENCY STEERING GEAR ROOM'S DECK IS COVERED IN OIL.
Condition: Unknown
Due 13 September 1987
Resolved 12 August 1987
Documentation
Issued 22 May 1987 Resolved
OBTAIN CERTIFICATE OF FITNESS REFLECTING MEPC 20(22), SUBMIT COPY TO COMMANDANT G-MTH-1 AND PLACE ONBOARD NEW SOE.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Deck/Cargo
Issued 6 January 1986 Resolved
REPAIR THE VENT DUCTING IN THE FORWARD BUNKER PUMPROOM.
Condition: Unknown
Due 6 January 1986
Resolved 6 January 1986
Deck/Cargo
Issued 6 January 1986 Resolved
REPLACE ALL FLAME SCREENS ON THE VACUUM SIDE OF THE P/V VALVES.
Condition: Unknown
Due 6 January 1986
Resolved 6 January 1986
Documentation
Issued 6 January 1986 Resolved
PLACE ONBOARD THE VESSEL A VALID CARGOES AND RESTRICTIONS LIST.
Condition: Unknown
Due 6 January 1986
Resolved 6 January 1986
Deck/Cargo
Issued 6 January 1986 Resolved
PROVIDE TWO OPERABLE FLAMMABLE GAS DETECTORS.
Condition: Unknown
Due 6 January 1986
Resolved 6 January 1986
Electrical
Issued 6 January 1986 Resolved
REPAIR EXPLOSION PROOF LIGHTING FIXTURE IN THE PAINT LOCKER FORWARD.
Condition: Unknown
Due 6 January 1986
Resolved 6 January 1986
Fire Fighting
Issued 6 January 1986 Resolved
PROVIDE AN ADDITIONAL SELF-CONTAINED BREATHING APPARATUS FOR THE PERSONAL PROTECTIVE EQUIPMENT.
Condition: Unknown
Due 6 January 1986
Resolved 6 January 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.