← All vessels
STOLT SURF
STOLT SURF is a 1971 tank ship. The Coast Guard has recorded 48 inspections since 1984, most recently in April 1998, along with 29 deficiencies and 1 operational control.
Records from 1984 to 1998. Most recent: inspection, 3 April 1998.
- Built
- 1971
- Last inspected
- 3 April 1998
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 29 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7027588 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
A8AQ
51694
Flag
LIBERIA
—
Maury page id
psix-51694
Inspections, by type
…with no type recorded33
Years with a record
13 calendar years (1984–1998)
The 48 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it9177 - Regulatory (Subpart C or D), Net Ton
23299 - Dead Weight, Ton
14533 - Regulatory (Subpart C or D), Gross Ton
23299 - Dead Weight, Ton
14533 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 48
3 April 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 414436
10 March 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 414450
10 March 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 787922
9 February 1995
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 838238
8 July 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 368326
8 July 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1465788
28 April 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 366413
9 February 1994
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1163219
6 February 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 31558
28 January 1994
MARPOL Annex V Examination · MARPOL Annex II Examination · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 853416
31 March 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 646315
26 March 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 73006
26 March 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 461921
19 March 1993
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1431196
2 March 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 646312
28 February 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 187154
25 February 1993
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 471983
11 August 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1249585
10 August 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1262767
26 May 1992
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 961772
18 May 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 526151
29 October 1991
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1244357
13 February 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1217530
3 February 1991
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 530137
17 October 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 928644
28 June 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 337908
18 June 1990
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1239677
6 June 1990
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 337532
6 June 1990
Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 898795
13 February 1990
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 441265
9 November 1989
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 917297
20 June 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 331030
20 June 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1349697
8 October 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 520544
10 April 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 518808
7 April 1988
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 322485
7 April 1988
Certificate of Compliance
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1340712
24 March 1987
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1325237
22 November 1986
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 312948
8 November 1986
Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1013906
5 November 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 532794
11 February 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 506427
7 September 1985
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 988897
16 August 1985
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 986481
15 March 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 515643
19 January 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977714
1 October 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282558
18 July 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 297054
Deficiency record · 29
Navigation
Issued 8 July 1994
Resolved
A VIOLATION OF 33 C.F.R. 164.37 IN THAT THE VESSEL'S SECONDARY MARINE RADARWAS INOPERATIVE.
Deck/Cargo
Issued 9 February 1994
Resolved
PRIOR TO CLOSED LOADING OPERATIONS, AFFIX PROPER LABELS IDENTIFYING CARGO HIGH LEVEL & CARGO OVERFILL ALARMS NEXT TO THE ALARMS. PROVIDE CLASS SOCIETY REPORT TO COGNIZANT OCMI.
Deck/Cargo
Issued 9 February 1994
Resolved
PRIOR TO CLOSED LOADING OPERATIONS, INCORPORATE VCS IN OIL TRANSFER PROCEDURES. PROVIDE COGNIZANT OCMI WITH CLASS REPORT.
Deck/Cargo
Issued 9 February 1994
Resolved
PRIOR TO CARGO TRANSFER OPERATIONS, INSPECT & REPLACE ALL PAINTED/CLOGGED P/V VALVE FLAME SCREENS.
Deck/Cargo
Issued 28 January 1994
Resolved
MAKE SATISFACTORY PERMANENT REPAIRS TO CARGO PIPING FOR 1P CARGO TANK BY 30JUN94 AS DIRECTED IN DNV CLASS RECOMMENDATION OF SAME DATE. _x001C_ _x001C_ _x001C_
Deck/Cargo
Issued 26 May 1992
Resolved
Gas free the No. 1 Pumproom and make available for Coast Guard inspection at the next U.S. port.
Navigation
Issued 6 June 1990
Resolved
33 CFR 88.05 The vessel did not have on board a copy of Inland Navigation Rules._x001C_
Fire Fighting
Issued 6 June 1990
Resolved
TWO HOSE STATION BOXES AFT, HAD LOCKING LUGS THAT WERE STRIPPED AND WERE UNABLE TO BE OPENED.
Electrical
Issued 6 June 1990
Resolved
LIGHTS IN #1 PUMPROOM HAVE TO BE REPLACED.
Unknown
Issued 6 June 1990
Resolved
STEP ON LADDER TO #3 PUMPROOM IS WEAK & WORN AND NEEDS TO BE REPLACED.
Unknown
Issued 6 June 1990
Resolved
AUDIBLE ALARM FOR OILY WATER SEPARATOR NOT FUNCTIONING.
Navigation
Issued 6 June 1990
Resolved
INLAND NAV RULES NOT ON BOARD.
Unknown
Issued 6 June 1990
Resolved
SOUND POWERED PHONE FROM AFTER STEERING TO BRIDGE DID NOT WORK DURING TEST OF EMERGENCY STEERING.
Unknown
Issued 6 June 1990
Resolved
GRATING IN #2 PUMPROOM IS BUCKLED UP AND MUST BE REPAIRED/REPLACED AND SECURED.
Electrical
Issued 6 June 1990
Resolved
LIGHTING IN FORWARD BUNKER PUMP ROOM WAS MALFUNCTIONING.
Fire Fighting
Issued 20 June 1989
Resolved
#2 FIRE PUMP INOPERATIVE.
Deck/Cargo
Issued 20 June 1989
Resolved
GAS DETECTORS ARE INOPERATIVE FOR PUMPROOMS.
Deck/Cargo
Issued 20 June 1989
Resolved
REPAIR PORTABLE O2 METERS AND EXPLOSIMETER.
Deck/Cargo
Issued 24 March 1987
Resolved
REPAIR ALL CLOSED GAUGING DEVICES. THIS IS TO BE COMPLETED PRIOR TO LOADINGANY CARGO REQUIRING CLOSED GAUGING, BUT NOT LATER THAN THE COMPLIANCE DATE REGARDLESS OF CARGOES CARRIED.
Fire Fighting
Issued 8 November 1986
Resolved
MAKE PERMANENT REPAIRS TO THE EMERGENCY FIRE PUMP DISCHARGE LINE IN THE FWDPUMPROOM.
Accommodation/Occupational Safety
Issued 8 November 1986
Resolved
PROVIDE ADEQUATE WATER PRESSURE TO EYE WASH STATION IN WAY OF #1 PUMPROOM.
Deck/Cargo
Issued 8 November 1986
Resolved
MAKE PERMANENT REPAIRS TO CARGO, STEAM, AND FIREMAIN MOUNTING BRACKETS AS NECESSARY.
Deck/Cargo
Issued 8 November 1986
Resolved
INSTALL BOLTS TO ALL CARGO AND BALLAST PIPING AS NEEDED.
Deck/Cargo
Issued 8 November 1986
Resolved
FREE AND RELUBRICATED P/V VALVES AS NEEDED.
Deck/Cargo
Issued 8 November 1986
Resolved
INSTALL METALIC BLANK FLANGES TO ALL CARGO HOSES WHEN NOT IN USE.
Deck/Cargo
Issued 8 November 1986
Resolved
PRIOR TO CARRYING ANY CARGO REQUIRING CLOSED GUAGING RE-INSTALL GUAGE FLOATS AND INSURE PROPER OPERATION.
Unknown
Issued 16 August 1985
Resolved
PRIOR TO USING DROP LINES WITH CONNECTIONS THAT ARE NOT FIXED PERMISSION SHALL BE OBTAINED FROM THE COTP.
Unknown
Issued 16 August 1985
Resolved
PROVIDE DOCUMENTATION FROM FLAG ADMINISTRATION & CLASSIFICATION SOCIETY APPROVINGS THE USE OF HIGH VELOCITY P.V. VALVES ON NO. 4 & CARGO TANK.
Unknown
Issued 16 August 1985
Resolved
REPLACE NO. 1 & NO.9 STB P.V. VALVES AND ALL OTHER P.V. VALVES SHALL BE OPENED, CLEANED AND INSPECTED PRIOR TO 30AUG85.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.