MAURY USCG vessel records Sign in
← All vessels

STOLT TENACITY

STOLT TENACITY is a 1978 tank ship. The Coast Guard has recorded 91 inspections since 1984, most recently in January 2008, along with 43 deficiencies and 5 operational controls.

Records from 1984 to 2008. Most recent: inspection, 7 January 2008.

Built
1978
Last inspected
7 January 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7401227 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
LIBERIA
—
Maury page id
psix-51696

Inspections, by type

…with no type recorded65
Years with a record 25 calendar years (1984–2008)
The 91 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11019 - Convention (Subpart B), Net Ton
42128 - Displacement, Ton
32093 - Dead Weight, Ton
20157 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MARS Towing Vessel · MISLE 94042 · 3 January 2004 · activity 1974313ANGEL 33 Tank Ship · MISLE 388218 · 3 January 2004 · activity 1974313G2507 Tank Barge · MISLE 50139 · 12 September 1994 · activity 164390G2508 Tank Barge · MISLE 50140 · 12 September 1994 · activity 164390NORGAS VOYAGER Tank Ship · MISLE 51720 · 12 September 1994 · activity 164390

Inspection history · 91

7 January 2008 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3126228
6 January 2008 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3125452
2 November 2007 Type not recorded
No type recorded · Station Dauphin Island · USCG Heartland District (CGD-H) · Activity 3092140
30 October 2007 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3089685
10 June 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2957098
6 June 2007 ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2953072
31 May 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2947726
25 May 2007 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2940021
18 May 2007 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2934012
2 October 2006 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2791679
24 September 2006 COC-CHEM Annual · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex II Examination · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2785289
13 September 2005 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2493863
24 August 2005 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2473671
19 May 2005 ISPS III Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2362674
9 August 2004 ISPS II Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2159494
8 January 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1979917
3 January 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1974313
2 January 2004 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1973414
12 December 2003 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1963013
12 May 2003 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1792877
10 May 2003 Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1790499
26 November 2002 Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1710912
28 December 2001 Annual Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1474250
21 December 2001 Security Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1488853
7 August 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 280646
7 August 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 282087
7 August 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 282091
7 August 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 284393
7 August 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 284396
7 August 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 821092
1 May 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 277656
2 August 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 431499
24 July 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 430993
2 November 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 422337
1 November 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 127349
31 October 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 174016
18 August 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 419354
2 August 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 418665
2 August 1998 Letter of Compliance (Initial/Renewal)
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 796166
21 April 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 402770
27 February 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 512260
6 May 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 390858
6 May 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1082642
2 January 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 386417
17 May 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 9034
14 May 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1237250
12 May 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 378328
9 February 1995 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1150915
12 September 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 164390
9 September 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 370459
8 May 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 366733
6 May 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1168858
26 August 1993 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 827303
24 August 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 360778
4 August 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 55789
4 April 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1147195
23 March 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 357278
19 March 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 51766
19 March 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1395907
17 March 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 833548
16 March 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 356953
21 January 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 355831
22 September 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 353363
21 September 1992 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1269794
8 May 1992 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 468538
22 November 1991 Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1246988
15 August 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 478527
14 August 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 345496
14 August 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 503267
11 September 1990 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 339267
11 September 1990 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 927646
9 January 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1235934
28 March 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 505154
4 July 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 324131
4 July 1988 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 898899
26 February 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1333943
21 February 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 538496
12 February 1988 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 462080
14 April 1987 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 532667
14 April 1987 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1022952
14 April 1987 MARPOL Annex II Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1330853
20 August 1986 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 540596
6 August 1986 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 310578
1 May 1986 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1297015
29 April 1986 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 308366
6 November 1985 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 467493
11 September 1985 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 460611
17 June 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 521657
2 February 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 490330
1 June 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 296513
1 June 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 972585

Deficiency record · 43

Navigation › Piloting/Steering › Gyro Compass
Issued 10 June 2007 Resolved
Vessel issued a Letter of Deviation to shift inside the Houston Ship Channel with an inoperable gyro compass. Vessel must provide a technician report attesting to the repairs of the gyro compass prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2007
Resolution: Received technician report attesting to repairs. The gyro compass is fully operational
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 24 September 2006 Resolved
The No.2 station Cargo Pump pressure gauge is not operating as designed.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 October 2006
Resolved 2 October 2006
Resolution: Received class report from DNV satisfying requirement.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 19 May 2005 Resolved
Found oily water separator out of calibration. See more details in vessel inspection reports dated 2005_05_19
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2005
Resolution: Veiwed proper operation. All Sat. See more details in vessel inspection reports dated 2005_05_19
Engineering › Steering Gear System › Actuator
Issued 19 May 2005 Resolved
Steering operating extremely slow to STBD. See more details in vessel inspection reports under Vessel Details >> Documents: dated 2005_05_19
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2005
Resolution: Received class report. See more details in vessel inspection reports under Vessel Details >> Documents: dated 2005_05_19
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 19 May 2005 Resolved
Incinerator leaking oil. See more details in vessel inspection reports under Vessel Details >> Documents: dated 2005_05_19
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2005
Resolution: All Sat. See more details in vessel inspection reports under Vessel Details >> Documents: dated 2005_05_19
Documentation › Logs/Records › Logbook (official)
Issued 19 May 2005 Resolved
STCW: Man Hours and other evidence shows Motormen are working in excess of STCW allowable standards. *** To be rectified by the DOC Company.
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 24 August 2005
Resolution: Bogus requirements. Vessel meets requirements.
Documentation › Logs/Records › Oil Record Book
Issued 19 May 2005 Resolved
Oil Record Book does not reflect activities on the vessel: See more details in vessel inspection reports under Vessel Details >> Documents: dated 2005_05_19 *** To be rectified by the DOC company.
Due 10 June 2005
Resolved 24 August 2005
Resolution: Inspected ORB. All Sat.
Electrical › Lighting (service) › Conductor
Issued 19 May 2005 Resolved
Lighting not working in the CO2 Room.
Due 27 May 2005
Resolved 27 May 2005
Resolution: Received Class Report. See more details in vessel inspection reports under Vessel Details >> Documents: dated 2005_05_19
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 19 May 2005 Resolved
Fire doors (entering Main Engine Room & Aft Emergency Escape) do not close and latch. See more details in vessel inspection reports under Vessel Details >> Documents: dated 2005_05_19
Due 27 May 2005
Resolved 27 May 2005
Resolution: Received class report. See more details in vessel inspection reports under Vessel Details >> Documents: dated 2005_05_19
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 19 May 2005 Resolved
Saft Patch on rubber hose to Pist Wash Tank. See more details in vessel inspection reports under Vessel Details >> Documents: dated 2005_05_19
Due 27 May 2005
Resolved 27 May 2005
Resolution: Received Class Report. See more details in vessel inspection reports under Vessel Details >> Documents: dated 2005_05_19
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, High Pressure (fuel injection)
Issued 19 May 2005 Resolved
Cracked piping on High pressure line for Diesel Engine. No. 3 or 4 cyclinder. Crack was in the area of Support Bracket of protective sleeve. See more details in vessel inspection reports under Vessel Details >> Documents: dated 2005_05_19
Due 27 May 2005
Resolved 27 May 2005
Resolution: Received Class Report. See more details in vessel inspection reports under Vessel Details >> Documents: dated 2005_05_19
Engineering › Freshwater Generation System › Piping
Issued 19 May 2005 Resolved
Soft Patches on Piping on the eductor for the F/W system. See more details in vessel inspection reports under Vessel Details >> Documents: dated 2005_05_19
Due 27 May 2005
Resolved 27 May 2005
Resolution: Received Class Report. IT was later stated that this was on thevacume side and only used as a safe guard. See more details in vessel inspection reports under Vessel Details >> Documents: dated 2005_05_19
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 9 August 2004 Resolved
All of the vessel's vapor connection flanges have a permanently attached half inch diameter stud at least one inch long projecting outward from the flange face in various locations. Arrange stud to be located at the top of the flange midway between bolt holes, and in line with the bolt hole pattern in accordance with 46 CFR 39.20-1(e).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 September 2004
Resolved 24 August 2005
Resolution: Inspected VCS flanges. All studs present.
Fire Fighting › Structural Fire Protection - General
Issued 12 December 2003 Resolved
Wire chases through forward and aft bulkheads in passageway leading to auxiliary steering are to be properly insulated to meet the structural fire boundary, to the satisfaction of Class, presently the packing is missing. Bulkheads are in way of frame #12 and #4.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 January 2004
Resolved 2 January 2004
Resolution: Received Class report #5230400 from Det Norske Veritas showing that item has been issued a condition of Class and therefore is considered corrected.
Stability › Watertight Integrity
Issued 12 December 2003 Resolved
Hatch coaming leading into the starboard chain locker is wasted and is to be permanently and properly repaired to the satisfaction of Class.
Action required: 705 - Other - as specified
Due 12 January 2004
Resolved 2 January 2004
Resolution: Received Class report #5230400 from Det Norske Veritas showing that item has been issued a condition of Class and therefore is considered corrected.
Construction/Loadline › Structures
Issued 12 December 2003 Resolved
Lower level of the port chain locker appears to be wasted. Vessel to have Class examine the inside lower level of the port chain locker, to ensure that the condition of the decking will hold the weight of the chain. LEGACY COMPONENT DESC: Deck Plating
Action required: 705 - Other - as specified
Due 12 January 2004
Resolved 2 January 2004
Resolution: Received Class report #5230400 from Det Norske Veritas showing that item has been corrected.
Fire Fighting › Fire Main
Issued 12 December 2003 Resolved
The fire main slip joint in the lower level of the bow thruster is leaking. Vessel to make permanent and proper repaired to the satisfaction of Class. LEGACY COMPONENT DESC: Condition
Action required: 705 - Other - as specified
Due 12 January 2004
Resolved 2 January 2004
Resolution: Received Class report #5230400 from Det Norske Veritas showing that item has been corrected.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 12 December 2003 Resolved
Make permanent and proper repairs to the hydraulic inline valve for the Framo pump for the #8 starboard cargo tank. LEGACY COMPONENT DESC: Cargo Pump
Action required: 705 - Other - as specified
Due 12 January 2004
Resolved 2 January 2004
Resolution: Received Class report #5230400 from Det Norske Veritas showing that item has been corrected.
Deck/Cargo › Vapor Control Systems
Issued 26 November 2002 Resolved
Vapor control line(s) not properly marked as vapor lines. Deficiency to be corrected prior to using VCS system. LEGACY COMPONENT DESC: Piping/Hoses
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 December 2002
Resolved 10 May 2003
Resolution: CORRECTED
Deck/Cargo › Vapor Control Systems
Issued 26 November 2002 Resolved
Several vapor control piping flanges missing 1" center stud. Deficiency to be corrected prior to using vapor control system. LEGACY COMPONENT DESC: Piping/Hoses
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 December 2002
Resolved 10 May 2003
Resolution: CORRECTED
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 26 November 2002 Resolved
Presure gauge indicator mounted on starboard deck tank, has worn seal, and indicatoions that cargo vapor is leaking. Gauge to be renewed or repaired.
Condition: Unknown
Due 11 December 2002
Resolved 26 November 2002
Resolution: Guage is no longer used and was removed and capped, prior to departure.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 26 November 2002 Resolved
VCS blank flange (colored and has stud hole) being used on a cargo line, flange to be removed and replaced with proper flange.
Condition: Unknown
Due 26 November 2002
Resolved 26 November 2002
Resolution: Flange removed and proper one installed.
Pollution Prevention/Response › Prevention Equipment
Issued 26 November 2002 Resolved
ODM equipment not operation awaiting parts. Submit to Coast Guard when repairs have been completed LEGACY COMPONENT DESC: Cargo Monitor/Control System
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 11 December 2002
Resolved 10 May 2003
Resolution: RECEIVED TECK REPORT AND RECEIPT OF PARTS TO REPAIR. WATCHED [name withheld] AND LISTEN TO ALARM.
Lifesaving › Launching Appliances
Issued 26 November 2002 Resolved
Hydro static release for EPRIB is outdated. Submit report to Coast Guard when new release is on board and installed. LEGACY COMPONENT DESC: Release Mechanism
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 11 December 2002
Resolved 10 May 2003
Resolution: CORRECTED
Lifesaving
Issued 7 August 2000 Resolved
Secure beckett lines on the port lifeboat, SOLAS 60 Ch.III Reg.11. Correct prior to next U.S. port.
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Deck/Cargo
Issued 2 August 1999 Resolved
IAW with LOC endorsement, vessel is prohibited from conducting, on-load _x001C_ or transfer of cargo until proof of proper operation of 98% (overfill) alarms is provided to class
Condition: Unknown
Due 3 August 1999
Resolved 10 August 1999
Navigation
Issued 24 July 1999 Resolved
VESSEL'S RADAR WAS INOPERABLE.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Electrical
Issued 2 August 1998 Resolved
ELECTRICAL WIRERING IN EMER GENERATOR SPACE JURY RIGGED
Condition: Unknown
Due 19 August 1998
Resolved 19 August 1998
Engineering
Issued 2 August 1998 Resolved
STEAM LINE NEAR OILY WATER SEPARATOR LEAKING
Condition: Unknown
Due 19 August 1998
Resolved 19 August 1998
Lifesaving
Issued 6 May 1994 Resolved
PROVIDE CLASS SURVEYORS REPORT ATTESTING TO SOLAS APPROVAL OF EXISTING FIREMAN'S OUTFIT PRESENTLY ON BOARD PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Deck/Cargo
Issued 6 May 1994 Resolved
INSTALL 1/2" (12MM) STUD ON OUTER MOST 6" FLANGE WITHIN CONTAINMENT AREA AND RE-LABEL PIPING (1 METER) AFT OF "STUDDED FLANGE" PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 6 May 1994
Resolved 6 May 1994
Deck/Cargo
Issued 6 May 1994 Resolved
MODIFY EXISTING 6" END FLANGES ON VCS CROSS OVER TO PREVENT END FLANGES FROM BEING USED AS AN ALTERNATE MANIFOLD CONNECTION PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 6 May 1994
Resolved 6 May 1994
Documentation
Issued 6 May 1994 Resolved
PROVIDE UP-TO-DATE COPIES OF 46 CFR1-40, 46 CFR 151-154, 33 CFR 125-199 ONBOARD PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 6 May 1994
Resolved 6 May 1994
Deck/Cargo
Issued 26 August 1993 Resolved
PRIOR TO USING VESSELS VAPOR CONTROL SYSTEM IN U. S. WATERS, PROVIDE PROPEROPERATION OF HIGH LEVEL AND OVERFILL VISIBLE AND AUDIBLE ALARM TO COGNIZANTCOAST GUARD INSPECTOR AND TO BE CONPLETED PRIOR TO NEXT U. S. VOYAGE.
Condition: Unknown
Due 26 August 1993
Resolved 26 August 1993
Unknown
Issued 9 January 1990 Resolved
TWO EXPLOSIMETERS TO BE REPLACED WITH VERIFICATION OF REPLACEMENT SENT TO MSO HOUSTON.
Condition: Unknown
Due 9 January 1990
Resolved 9 January 1990
Documentation
Issued 9 January 1990 Resolved
DUE TO CHANGE IN OWNERSHIP, CERTIFICATE OF FITNESS MUST BE SUBMITTED TO CG HQ FOR ISSUANCE OF NEW SUBCHAPTER 'O' ENDORSEMENT.
Condition: Unknown
Due 9 January 1990
Resolved 9 January 1990
Documentation
Issued 14 April 1987 Resolved
OBTAIN CERTIFICATE OF FITNESS REFLECTING MEPC 20(22), SUBMIT COPY TO COMMANDANT (G-MTH-1), AND PLACE ONBOARD NEW SUBCHAPTER "O" ENDORSEMENT.
Condition: Unknown
Due 14 April 1987
Resolved 14 April 1987
Documentation
Issued 1 May 1986 Resolved
NOT LATER THAN 31 MAY 1986 PROVIDE DOCUMENTATION FROM CLASSIFICATION SOCIETY AND FLAG ADMINISTRATION APPROVING THE USE OF HIGH VELOCITY P.V. VALVES ON THE PORT & STARBOARD DECK TANKS.
Condition: Unknown
Due 1 May 1986
Resolved 1 May 1986
Deck/Cargo
Issued 1 May 1986 Resolved
DROP LINES WITHOUT FIXED CONNECTIONS SHALL NOT BE USED TO LOAD CARGO IN US WATERS UNLESS PERMISSION IS OBTAINED FROM THE LOCAL COTP.
Condition: Unknown
Due 1 May 1986
Resolved 1 May 1986
Documentation
Issued 1 June 1984 Resolved
COPY OF 46 CFR PERA 34,35,153 NOT ON BOARD.
Condition: Unknown
Due 1 June 1984
Resolved 1 June 1984
Navigation
Issued 1 June 1984 Resolved
LIGHT LIST AND COAST PILOT OUTDATED.
Condition: Unknown
Due 1 June 1984
Resolved 1 June 1984
Deck/Cargo
Issued 1 June 1984 Resolved
FLAME SCREEN ON STBD AFT DRAIN TANKS VENT NOT FUNCTIONAL DUE TO IMPROPER INSTALLATION.
Condition: Unknown
Due 1 June 1984
Resolved 1 June 1984
Accommodation/Occupational Safety
Issued 1 June 1984 Resolved
VENTILATION FAN MOTOR AND DUTING FOR MIDSHIP PUMPMAN DECKHOUSE INOP AND IN NEED OF REPAIR
Condition: Unknown
Due 1 June 1984
Resolved 1 June 1984

Ownership record