MAURY USCG vessel records Sign in
← All vessels

STEVEN N

STEVEN N is a 1979 tank ship. The Coast Guard has recorded 88 inspections since 1986, most recently in November 2007, along with 40 deficiencies and 15 operational controls.

Records from 1986 to 2007. Most recent: inspection, 21 November 2007.

Built
1979
Last inspected
21 November 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7411064 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
PANAMA
—
Maury page id
psix-51700

Inspections, by type

…with no type recorded53
Years with a record 18 calendar years (1986–2007)
The 88 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it10143 - Convention (Subpart B), Net Ton
40121 - Dead Weight, Ton
57320 - Displacement, Ton
33807 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 88

21 November 2007 ISPS III Exam · COC-GAS Annual
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3102564
16 November 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3099623
28 June 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2976740
27 June 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2975630
12 June 2007 MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam · ISPS III Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2955448
21 May 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2936129
16 May 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2932413
8 March 2007 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2883956
6 March 2007 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2882586
28 February 2007 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2879430
8 October 2006 Type not recorded
No type recorded · Station St Petersburg · USCG Southeast District (CGD-SE) · Activity 2796185
6 October 2006 COC-GAS Renew · ISPS II Exam · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2795235
4 June 2006 Type not recorded
No type recorded · Station St Petersburg · USCG Southeast District (CGD-SE) · Activity 2669555
3 June 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2670770
15 April 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2628388
13 April 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2623838
5 April 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2617521
15 January 2006 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2567176
7 October 2005 ISPS III Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2506454
7 October 2005 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2509580
7 August 2005 MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex II Examination · ILO-147 Exam · MARPOL Annex V Examination · COC-GAS Annual · STCW 95 Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2455889
6 August 2005 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2453238
5 August 2005 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2452689
6 June 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2381370
9 March 2005 NPV Safety Exam
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2307961
27 February 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2300202
6 December 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2254211
5 December 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2253433
26 July 2004 ILO-147 Exam · ISPS II Exam · COC-GAS Renew · STCW 95 Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2146027
25 July 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2145105
12 July 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2130470
11 July 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2129656
26 February 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2014131
26 February 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2014656
26 February 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2026350
7 July 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1838896
11 April 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1777716
23 February 2003 Security Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1748174
6 January 2003 Security Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1726769
3 January 2003 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1725527
13 November 2002 Security Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1705229
2 October 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1683509
29 September 2002 Security Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1681601
29 September 2002 Security Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1681901
26 July 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1655085
19 June 2002 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1635741
18 June 2002 Certificate of Compliance · Ballast Water Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1632797
15 June 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1631653
19 January 2001 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 286218
11 September 2000 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 281986
4 August 2000 Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1053047
20 July 2000 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 279944
20 July 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1052083
28 February 1998 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 783034
23 February 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 413072
19 February 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 412998
19 February 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 778612
31 May 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1171426
25 June 1993 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 844060
4 June 1993 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1146908
14 April 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 534812
7 October 1992 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 539762
17 September 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 459479
1 May 1992 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1254496
11 April 1992 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1263591
19 April 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 917416
10 April 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 474995
15 November 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1239782
24 August 1990 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 904298
1 December 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1214135
22 November 1989 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 918697
1 November 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 449901
5 October 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 332934
5 October 1989 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1195443
29 August 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 325369
29 August 1988 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1349466
5 February 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 452934
20 September 1987 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1008680
13 August 1987 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 512534
13 August 1987 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1029906
13 August 1987 MARPOL Annex II Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1337346
10 April 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315069
15 March 1987 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1324793
14 March 1987 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 314704
6 February 1987 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 456093
16 September 1986 Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1310123
27 August 1986 Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 988455
22 August 1986 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 989247

Deficiency record · 40

Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 7 August 2005 Resolved
#1 and #4 overfill alarms inoperable. Vessel cannot load these tanks in US waters.
Action required: 705 - Other - as specified
Due 9 August 2005
Resolved 22 August 2005
Resolution: Received class report attesting to repairs.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 7 August 2005 Resolved
Inert Gas Generator was unable to start.
Action required: 705 - Other - as specified
Due 9 August 2005
Resolved 22 August 2005
Resolution: Received class report attesting to repairs.
Deck/Cargo › Cargo Stowage › General
Issued 7 August 2005 Resolved
Cargo leak in port side compressor room. Space had a strong odor when opened.
Action required: 705 - Other - as specified
Due 9 August 2005
Resolved 22 August 2005
Resolution: Received class report attesting to repairs.
Deck/Cargo › Cargo Refrigeration › General
Issued 7 August 2005 Resolved
Compressor #1 had liquid filled seal opened for maintenance. Vessel is not to use compressors #1 and #3 in the US waters until repairs are verified by class.
Action required: 705 - Other - as specified
Due 9 August 2005
Resolved 22 August 2005
Resolution: Received class report attesting to repairs.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 7 August 2005 Resolved
STBD manifold quick closing valve will not close.
Action required: 705 - Other - as specified
Due 9 August 2005
Resolved 22 August 2005
Resolution: Received class report attesting to repairs.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 7 August 2005 Resolved
Vessel posted fire control plan does not display class A and class B fire doors.
Action required: 705 - Other - as specified
Due 9 August 2005
Resolved 22 August 2005
Resolution: Received class report attesting to repairs.
Construction/Loadline › Structures › Deck Plating
Issued 26 July 2004 Resolved
Vessel to make permanent repairs to STBD catwalk forward of the Cargo Control Room, to the satisfaction of class, prior to next U.S. port.
Action required: 15 - Rectify deficiencies by next port
Due 26 July 2004
Resolved 5 August 2004
Resolution: Recieved class report attesting to the satisfactory repairs/operation.
Construction/Loadline › Structures › Door
Issued 26 July 2004 Resolved
Vessel to adjust airlock doors and alarm indicators to close properly, to the satisfactory of class, prior to next U.S. port.
Action required: 15 - Rectify deficiencies by next port
Due 26 July 2004
Resolved 5 August 2004
Resolution: Recieved class report attesting to the satisfactory repairs/operation.
Deck/Cargo
Issued 19 January 2001 Resolved
HYDROCARBON DETECTION MODULE ON VAPOR DETECTION UNIT #2-4 IS NOT CONNECTED_x001C_IT IS DUE TO BE INSTALLED AT NEXT DRY DOCK.(30MAR01) VESSEL IS NOT TO CARRYANY LPN CARGO UNTIL THIS DISCREPANCY IS CLEARED.
Condition: Unknown
Due 30 March 2001
Resolved 18 June 2002
Resolution: CLEARED.
Deck/Cargo
Issued 20 July 2000 Resolved
Discharge pressure gauge for #2 cargo tank on cargo control room monitoringpanel inoperative.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Deck/Cargo
Issued 20 July 2000 Resolved
Low pressure gauges on bridge are inoperative.
Condition: Unknown
Due 12 September 2000
Resolved 12 September 2000
Deck/Cargo
Issued 20 July 2000 Resolved
Hydrocarbon detection module on vapor detection unit #2-#4 inoperative.
Condition: Unknown
Due 30 March 2001
Resolved 19 January 2001
Deck/Cargo
Issued 19 February 1998 Resolved
INSTALL TEMPERATURE SENSORS IN BOTTOM AND TOP OF THE PORT & STARBOARD CARGODECK TANKS IAW IGC CHAPTER XIII, REG. 13.5.
Condition: Unknown
Due 4 August 2000
Resolved 4 August 2000
Deck/Cargo
Issued 19 February 1998 Resolved
REPAIR THE #1 PORT CARGO TANK ELECTRONIC GAUGE.
Condition: Unknown
Due 25 July 2000
Resolved 25 July 2000
Deck/Cargo
Issued 19 February 1998 Resolved
INSTALL HIGH & LOW PRESSURE ALARMS IN THE PORT AND STARBOARD CARGO DECK TANKS AND PROVIDE CARGO CONTROL ROOM MONITORING OF THOSE ALARMS IAW IGC CHAPTER XIII, REG. 13.4.
Condition: Unknown
Due 4 August 2000
Resolved 4 August 2000
Deck/Cargo
Issued 19 February 1998 Resolved
REPAIR AND PROVE OPERATION OF THE INERT GAS SYSTEM.
Condition: Unknown
Due 21 February 1998
Resolved 3 March 1998
Deck/Cargo
Issued 19 February 1998 Resolved
REPAIR AND PROVE OPERATION THE FIXED GAS DETECTION SYSTEM 2-4.
Condition: Unknown
Due 21 February 1998
Resolved 3 March 1998
Deck/Cargo
Issued 19 February 1998 Resolved
REPAIR AND PROVE OPERATION OF THE LOW PRESSURE ALARMS IN #1 AND #4 CARGO TANKS.
Condition: Unknown
Due 21 February 1998
Resolved 23 February 1998
Deck/Cargo
Issued 19 February 1998 Resolved
RENEW/REPLACE THE GROUNDING CABLES WHERE MISSING IN THE CARGO COMPRESSOR ROOM.
Condition: Unknown
Due 21 February 1998
Resolved 23 February 1998
Electrical
Issued 19 February 1998 Resolved
REPAIR AND PROVE OPERATION OF THE EMERGENCY GENERATOR.
Condition: Unknown
Due 21 February 1998
Resolved 23 February 1998
Deck/Cargo
Issued 19 February 1998 Resolved
PROVIDE CLASS SOCIETY DOCUMENTATION THAT THE ELECTRONIC MONITORING DEVICES FOR THE CARGO DECK EMERGENCY SHUTDOWN SYSTEM ARE EQUIVALENT TO THE FUSIBLE ELEMENT (MELTING LINK SYSTEM) REQUIRED BY IGC CHAPTER V, REG. 5.3.4.
Condition: Unknown
Due 21 February 1998
Resolved 23 February 1998
Lifesaving
Issued 19 February 1998 Resolved
RENEW THE EPIRB BATTERIES.
Condition: Unknown
Due 21 February 1998
Resolved 23 February 1998
Fire Fighting
Issued 4 June 1993 Resolved
PRIOR TO NEXT U.S. PORT, INSTALL A FIRE EXTINGUISHING SYSTEM IN PAINT LOCKER TO SATISFACTION OF FLAG ADMINISTRATION.
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Deck/Cargo
Issued 4 June 1993 Resolved
PRIOR TO NEXT U.S. PORT, HYDROSTATICALLY TEST VESSEL'S CARGO HOSES.
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Lifesaving
Issued 4 June 1993 Resolved
PRIOR TO NEXT U.S. PORT, PROVIDE ONBOARD DOCUMENTATION THAT SELF CONTAINED BREATHING APPARATI HAVE BEEN PROFESSIONALLY SERVICED WITHIN LAST 12 MONTHS.
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Construction/Loadline
Issued 11 April 1992 Resolved
MAKE WING BALLAST TANK AVAILABLE FOR COAST GUARD INSPECTION AT NEXT PORT OFCALL.
Condition: Unknown
Due 11 April 1992
Resolved 11 April 1992
Documentation
Issued 11 April 1992 Resolved
PROVIDE OIL TRANSFER PROCEDURES AT NEXT U.S. PORT OF CALL.
Condition: Unknown
Due 11 April 1992
Resolved 11 April 1992
Deck/Cargo
Issued 22 November 1989 Resolved
RENEW ALL SECTIONS OF CARGO PIPING THAT ARE EXCESSIVELY WASTED OR FITTED WITH SOFT PATCHES, & PROVIDE VERIFICATION FROM THE CLASS SOCIETY THAT ALL CARGO PIPING HAS BEEN INSPECTED AND IS OF AT LEAST MINIMUM THICKNESS AS DETERMINED BY CLASS RULES.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Deck/Cargo
Issued 22 November 1989 Resolved
PROVIDE VERIFICATION FROM THE CLASS SOCIETY THAT ALL VALVES IN THE CARGO SYSTEM HAVE BEEN INSPECTED AND DETERMINED TO BE SUITABLE FOR LOCATION AND PROVEN OPERABLE LEAK FREE (BOTH INTERNALLY AND EXTERNALLY).
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Electrical
Issued 22 November 1989 Resolved
PROVIDE VERIFICATION FROM THE CLASS SOCIETY THAT ALL ELECTRICAL FIXTURES AND CABLE RUNS IN THE CARGO AREA ARE IN SERVICABLE CONDITION AND ARE SUITABLE FOR THEIR LOCATION, AND THAT ALL FIXTURES IN GAS DANGEROUS ZONES ARE EXPLOSION PROOF.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Unknown
Issued 13 August 1987 Resolved
REPLACE THE LIGHTS IN THE STBD STORAGE ROOM WITH EXPLOSION-PROOF LIGHTS, OR HAVE THE ELECTRICAL POWER TO THE LIGHTS CUT-OUT UPON OPENING BOTH AIR LOCK DOORS.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Deck/Cargo
Issued 13 August 1987 Resolved
HAVE BOTH SAFETY RELIEF VALVES ON #3 CARGO TANK AND ONE ON #2 CARGO TANK SET & SEALED BY COMPETENT AUTHORITY.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Deck/Cargo
Issued 15 March 1987 Resolved
VESSEL TO MAKE PERMANENT REPAIRS TO GASKET ON PORT FWD CARGO DECK TANK. GASKET TO BE RENEWED UPON OFFLOAD OF CARGO. REPAIRS TO BE ACCOMPLISHED PRIOR TO RETURN TO NEXT US PORT.
Condition: Unknown
Due 15 March 1987
Resolved 15 March 1987
Unknown
Issued 22 August 1986 Resolved
PROVIDE OIL TRANSFER PROCEDURES IN ACCORDANCE WITH 33CFR155.740.
Condition: Unknown
Due 22 August 1986
Resolved 22 August 1986
Unknown
Issued 22 August 1986 Resolved
PRIOR TO ENTERING U.S. WATERS, PROVIDE ON BOARD THE FOLLOWING: 1986 COAST GUARD LIGHT LIST, 1986 U.S. COAST PILOT, RECENT ISSUE CHARTS AND NOTICES TOMARINERS, AND RELATIVE MOTION PLOTTING SHEETS.
Condition: Unknown
Due 22 August 1986
Resolved 22 August 1986
Unknown
Issued 22 August 1986 Resolved
PRIOR TO LOADING OR DISCHARGING ANHYDROUS AMMONIA IN U.S. WATERS, THE ANHYDROUS AMMONIA FIXED GAS DETECTION SYSTEM SHALL BE OPERATIONALLY TESTED IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 22 August 1986
Resolved 22 August 1986
Unknown
Issued 22 August 1986 Resolved
HAVE #3 CARGO TANK SAFETY RELIEF VALVES SET AND SEALED BY COMPETENT AUTHORITY.
Condition: Unknown
Due 22 August 1986
Resolved 22 August 1986
Unknown
Issued 22 August 1986 Resolved
PROVIDE CERTIFICATE FROM COMPETENT AUTHORITY DETAILING SET PRESSURES OF ALLCARGO TANK SAFETY RELIEF VALVES.
Condition: Unknown
Due 22 August 1986
Resolved 22 August 1986
Unknown
Issued 22 August 1986 Resolved
PRIOR TO LOADING OR DISCHARGING THROUGH THE STBD MANIFOLD, SHOW SATISFACTORY OPERATION OF STBD #2 LIQUID VALVE EMERGENCY SHUTDOWN. (VALVE MUST OPERATE THROUGH 90 DEGREES OF TRAVEL)
Condition: Unknown
Due 22 August 1986
Resolved 22 August 1986
Unknown
Issued 22 August 1986 Resolved
PRIOR TO CARRYING OR LOADING CARGO IN DECK CARGO TANKS WHILE IN U.S. WATERS, CONNECT DECK CARGO TANK REMOTE OPERATED VALVES TO THE EMERGENCY SHUTDOWN SYSTEM AND TEST IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 22 August 1986
Resolved 22 August 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.