The 6 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 38 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for BUNGA SEPANG, retrieved 18 September 2026. mauryrecords.com/v/psix-51707.html
Documentation record
Tonnage as PSIX records it10690 - Regulatory (Subpart C or D), Net Ton 29957 - Dead Weight, Ton 18959 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 6
26 February 1988Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1336005
29 January 1988Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1019938
22 January 1988Certificate of Compliance
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1324425
21 January 1988Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1320071
23 June 1986Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 466870
23 June 1986Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 996937
MAKE PERMANENT REPAIRS TO FIXED FOAM SUPPLY LINE. THREE TEMPORARY REPAIRS WERE NOTED APPROX. 30-40 FT. AFT OF KING POST ON PORT SIDE. ONE OF THREE REPAIRS WERE MADE DURING EXAM.
Condition: Unknown
Due 22 January 1988
Resolved 22 January 1988
Deck/Cargo
Issued 22 January 1988Resolved
MAKE PERMANENT REPAIRS TO RESTRICTED GAUGING DEVICES TO #1 STBD. AND #2 CENTER C/T. GAUGING DEVICES ARE WASTED AND OPEN TO THE ATMOSPHERE.
Condition: Unknown
Due 22 January 1988
Resolved 22 January 1988
Deck/Cargo
Issued 22 January 1988Resolved
RENEW WASTED BOLTS TO P/V VALVE COVER ON FORWARD STACK VENT. RENEW WASTED COVER TO P/V VALVE ON AFT STACK VENT.
Condition: Unknown
Due 22 January 1988
Resolved 22 January 1988
Deck/Cargo
Issued 22 January 1988Resolved
MAKE TEMPORARY REPAIRS TO PORT CARGO CONTAINMENT WHERE WASTED PRIOR TO NEXTU.S. POC. PERMANENT REPAIRS BY 22FEB88.
Condition: Unknown
Due 22 January 1988
Resolved 22 January 1988
Fire Fighting
Issued 22 January 1988Resolved
MAKE PERMANENT REPAIRS TO BOTH FIRE/BALLAST PUMPS WHICH ARE LEAKING AT SEALS. COMPLETE BY NEXT U.S. POC.
Condition: Unknown
Due 22 January 1988
Resolved 22 January 1988
Engineering
Issued 22 January 1988Resolved
REMOVE BLACK OIL ACCUMULATING IN BILGE FROM BOILER FOR STEAM CARGO PUMP. COMPLETE BY NEXT U.S. POC.
Condition: Unknown
Due 22 January 1988
Resolved 22 January 1988
Fire Fighting
Issued 22 January 1988Resolved
MAKE PERMANENT REPAIRS TO LEAKING FIRE/FOAM MONITOR ON PORT SIDE IN WAY OF KING POST (#2 MONITOR ON PORT SIDE COUNTING FROM BOW).
Condition: Unknown
Due 22 January 1988
Resolved 22 January 1988
Unknown
Issued 23 June 1986Resolved
PROVIDE FLAME SCREENS FOR THE TWO FORWARD BUNKER TANK VENTS.
Condition: Unknown
Due 23 June 1986
Resolved 23 June 1986
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.