Records from 1985 to 2005. Most recent: operational control imposed, 12 February 2005.
Inspection history · 24
12 February 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2292331
9 February 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2289673
11 February 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2007576
8 January 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1982072
4 January 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1975064
4 January 2004
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1975119
12 September 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1903320
17 July 2003
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1849225
11 July 2003
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1846928
24 April 2002
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1608665
5 June 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 278270
5 June 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1050266
5 September 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 407536
5 September 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1121401
5 July 1996
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1086490
23 February 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 717009
30 January 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 387780
30 January 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1367625
24 July 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 338420
24 July 1990
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1236031
31 March 1988
Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1299376
19 September 1987
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1324623
9 October 1986
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1317132
10 September 1985
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 491716
Deck/Cargo
Issued 11 July 2003
Resolved
Loss of positive pressure in motor room airlock did not deenergize all unintrinsically safe componets. Prove proper operation to satisfaction of the administration prior to cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2003
Resolution: Received satisfactory report received from Det Norske Veritas.
Deck/Cargo
Issued 11 July 2003
Resolved
Vessel could not prove proper set point and alarms for tank high pressure alarms. Prove proper operation prior to conducting cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2003
Resolution: Received satisfactory report from [name withheld] Veritas.
Lifesaving
Issued 11 July 2003
Resolved
Air Compressor for breathing apparatus not serviced and tested annually. Have air compressor tested by expert and provide evidence of test by 11 Aug 2003.
Due 11 August 2003
Resolved 17 July 2003
Resolution: Received fax indicating breathing apperatus has been serviced and tested. Vessel cleared to sail.
Unknown
Issued 5 September 1997
Resolved
Repair leaking saltwater cooling line in compressor room on portside.
Condition: Unknown
Due 4 October 1997
Resolved 4 October 1997
Fire Fighting
Issued 5 September 1997
Resolved
Professionally service EEBAs and SCBAs IAW IGC 14.2.6.
Condition: Unknown
Due 4 October 1997
Resolved 4 October 1997
Lifesaving
Issued 5 September 1997
Resolved
Replace lifelines on port and starboard lifeboats which are required to be buoyant IAW SOLAS 74 Chap III/41.7.3.
Condition: Unknown
Due 5 November 1997
Resolved 30 December 1997
Construction/Loadline
Issued 30 January 1996
Resolved
MAKE ALL BALLAST TANKS COVERS ON MAIN DECK WATERTIGHT. MANHOLE COVERS HAD BROKEN AND MISSING STUDS; CORRECT ON NEXT US PORT CALL.
Condition: Unknown
Due 30 January 1996
Resolved 30 January 1996
Lifesaving
Issued 30 January 1996
Resolved
PROVIDE RING BUOY ARRANGEMENT AS PER CHAPTER III REG 7.1.3 SOLAS 92 ON NEXTUS PORT CALL.
Condition: Unknown
Due 30 January 1996
Resolved 30 January 1996
Deck/Cargo
Issued 30 January 1996
Resolved
MAKE ALL DRAINS MECHANICAL PLUGS TO ALL CONTAINMENT AND COAMING SYSTEM ON NEXT US PORT CALL.
Condition: Unknown
Due 30 January 1996
Resolved 30 January 1996
Lifesaving
Issued 30 January 1996
Resolved
INFORM MSO PUGET SOUND UPON ARRIVAL AND INSTALLATION OF ALL LIFERAFTS FROM SERVICING PRIOR TO DEPARTURE PORT OF FERNDALE, WA.
Condition: Unknown
Due 1 February 1996
Resolved 2 February 1996
Navigation
Issued 30 January 1996
Resolved
MAKE AVAILABLE CHANNEL 5A PRIOR TO DEPARTURE FROM FERNDALE, WA OPERATIONAL.
Condition: Unknown
Due 1 February 1996
Resolved 2 February 1996
Lifesaving
Issued 30 January 1996
Resolved
PROVE PROPER OPERATION OF STBD LIFEBOAT ENGINE PRIOR TO DEPARTURE.
Condition: Unknown
Due 1 February 1996
Resolved 2 February 1996
Engineering
Issued 24 July 1990
Resolved
PROVIDE DATA ON OILY WATER SEPARATOR ALARM TO COMDT USCG. FOR APPROVAL
Condition: Unknown
Due 24 July 1990
Resolved 24 July 1990
Unknown
Issued 9 October 1986
Resolved
PRIOR TO CARGO TRANSFER OR BUNKERING OPERATIONS PROVIDE IOPP CERTIFICATE.
Condition: Unknown
Due 9 October 1986
Resolved 9 October 1986
Unknown
Issued 9 October 1986
Resolved
HAVE CLASSIFICATION SOCIETY SET AND SEAL ALL PRESSURE RELIEF VALVES LOCATED OUT ON DECK PRIOR TO 24OCT86.
Condition: Unknown
Due 9 October 1986
Resolved 9 October 1986
Unknown
Issued 9 October 1986
Resolved
AT VESSELS NEXT SCHEDULED DRYDOCKING BUT NOT LATER THAN 31DEC86 MAKE PERMANENT REPAIRS TO VENTILATION SECURING FLAPPER VALVE LOCATED IN OUTLET LINE FOR LPG ROOM.
Condition: Unknown
Due 9 October 1986
Resolved 9 October 1986
Unknown
Issued 9 October 1986
Resolved
MAKE TEMPORARY REPAIRS TO COMPRESSOR ROOM VENTILATION AIR DUCT LOCATED IN PAINT LOCKER AMID SHIP PRIOR TO 24OCT86 AND MAKE PERMANENT REPAIRS TO TEMPORARY REPAIRS AT VESSELS NEXT SCHEDULED DRYDOCKING BUT NOT LATER THAN 31DEC86.
Condition: Unknown
Due 9 October 1986
Resolved 9 October 1986