Records from 1984 to 2000. Most recent: inspection, 14 September 2000.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 39
14 September 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 282123
14 September 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1053772
4 May 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 415544
20 October 1997
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 408858
20 October 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 409208
20 October 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1113889
8 December 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 385609
8 December 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1454285
11 July 1995
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 883485
29 September 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 870936
31 January 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1164398
22 January 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 678906
13 January 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 63809
25 June 1993
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1154229
18 June 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 359009
18 June 1993
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1135472
15 May 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 892647
13 May 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 330326
13 May 1989
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1035981
8 May 1989
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 512632
12 December 1988
Administrative
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1209123
1 November 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 490198
19 February 1988
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1330106
12 February 1988
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1023107
10 February 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 505884
10 February 1988
Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1023231
10 February 1988
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1330351
16 December 1987
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1311419
7 October 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 478284
24 September 1987
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1008176
24 April 1987
MARPOL Annex II Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1009860
6 April 1987
MARPOL Annex II Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1021719
30 March 1987
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1019629
22 February 1987
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1015903
26 January 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 513383
20 August 1986
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 438912
12 February 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296994
10 January 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 484348
26 January 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1279301
Deck/Cargo
Issued 20 October 1997
Resolved
PRIOR TO CARRIAGE OF NEXT CARGO THAT REQUIRES INERTING, PROVE PROPER OPERATION OF INERT GAS SYSTEM TO THE SATISFACTION OF CLASS.
Condition: Unknown
Due 6 May 1998
Resolved 6 May 1998
Deck/Cargo
Issued 20 October 1997
Resolved
PRIOR TO CARGO OPERATIONS, PROVE PROPER OPERATION OF CARGO TANK HIGH HIIH LEVEL ALARMS.
Condition: Unknown
Due 21 October 1997
Resolved 22 October 1997
Navigation
Issued 20 October 1997
Resolved
PROVE PROPER OPERATION OF COMMUNICATION BETWEEN BRIDGE AND STEERING GEAR COMPARTMENT.
Condition: Unknown
Due 6 May 1998
Resolved 6 May 1998
Fire Fighting
Issued 20 October 1997
Resolved
RECHARGE ONE HALON BOTTLE IN FIXED SYSTEM FOR COMPRESSOR ROOM.
Condition: Unknown
Due 6 May 1998
Resolved 6 May 1998
Engineering
Issued 20 October 1997
Resolved
PRIOR TO USING OILY WATER SEPERATOR, PROVE PROPER OPERATION AND CALIBRATIONOF OIL CONTENT METER.
Condition: Unknown
Due 20 October 1997
Resolved 22 October 1997
Documentation
Issued 29 September 1994
Resolved
PRIOR TO DEPARTURE, HOUSTON, UPDATE PROCEDURES AND ARRANGEMENTS MANUAL TO REFLECT CURRENT TABLE/CARGOES.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Navigation
Issued 29 September 1994
Resolved
CORRECT NAVIGATION CHARTS PRIOR TO DEPARTURE PORT OF HOUSTON.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Deck/Cargo
Issued 29 September 1994
Resolved
PRIOR TO LOADING CARGO, PROVIDE CLASS SOCIETY REPORT OF PROPERLY FUNCTIONING GAS DETECTION SYSTEM. ALL ACCESSIBLE SAMPLE HEADS ARE TO BE DEMONSTRATED AND PROPER LABELING OF THESE SAMPLE HEADS ARE TO BE ESTABLISHED.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Deck/Cargo
Issued 29 September 1994
Resolved
PRIOR TO DEPARTURE PORT OF HOUSTON, MAKE TEMPORARY REPAIRS TO INERT GAS LINE AT COFFERDAM FWD OF SLOP TANK.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Deck/Cargo
Issued 29 September 1994
Resolved
PRIOR TO NEXT U.S. PORT CALL, REPAIR HYDRAULIC OIL LEAK AT #1 STBD PUMP.
Condition: Unknown
Due 29 September 1994
Resolved 29 September 1994
Deck/Cargo
Issued 29 September 1994
Resolved
CORRECT DEFICIENCIES TO ENSURE PROPER OPERATION OF IGS PRIOR TO NEXT U.S._x001C_ PORT CALL.
Condition: Unknown
Due 29 September 1994
Resolved 29 September 1994
Deck/Cargo
Issued 29 September 1994
Resolved
PRIOR TO CONDUCTING CARGO OPERATIONS, PROVIDE 1 ADDITIONAL LEL METER FOR A COMPLEMENT OF 2 AND DEMONSTRATE OPERATION AND PROFICIENCY. THIS UNIT IS TO BE OWNED BY OPERATOR OF VESSEL.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Deck/Cargo
Issued 29 September 1994
Resolved
PRIOR TO CONDUCTING CARGO OPERATIONS, MAKE PERMANENT REPAIRS TO EMERGENCY SHUTDOWN ON #2 STBD CARGO TANK DOME AND DEMONSTRATE PROPER OPERATION.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Deck/Cargo
Issued 29 September 1994
Resolved
PRIOR TO CONDUCTING CARGO OPERATIONS, PROVIDE TOXIC DRAGER TUBES FOR SAMPLING BUTANE.
Condition: Unknown
Due 29 September 1994
Resolved 29 September 1994
Lifesaving
Issued 29 September 1994
Resolved
PRIOR TO DEPARTURE PORT OF HOUSTON, REMOVE 'JURY RIGGED' LIGHTING FROM STEERING GEAR ROOM.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Lifesaving
Issued 29 September 1994
Resolved
PRIOR TO NEXT U.S. PORT CALL, PROVIDE LIGHTING COVER FOR UNCOVERED LIGHTINGIN STEERING GEAR ROOM.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Lifesaving
Issued 29 September 1994
Resolved
PRIOR TO NEXT U.S. VOYAGE, MAKE PERMANENT REPAIRS TO HOLED CONTAINMENT AT FUEL OIL VENT ON STBD SIDE NEAR MIDSHIPS.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Lifesaving
Issued 29 September 1994
Resolved
PRIOR TO CONDUCTING CARGO OPERATIONS, REMOVE DEAD-ENDED WIRING OR INSTALL CORRECTLY WHERE WIRING IS TAPED AND DEAD-ENDED FWD OF ELECTRIC MOTOR HOUSE AND NEAR #1 PORT CARGO PUMP.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Deck/Cargo
Issued 29 September 1994
Resolved
DEMONSTRATE PROPER OPERATION AND CREW PROFICIENCY FOR HIGH AND LOW PRESSUREALARMS FOR CARGO SYSTEM PRIOR TO LOADING CARGO.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Deck/Cargo
Issued 29 September 1994
Resolved
CORRECT DEFICIENCIES TO ENSURE PROPER OPERATION OF AIR DRYING SYSTEM PRIOR TO NEXT U.S. PORT CALL.
Condition: Unknown
Due 29 September 1994
Resolved 29 September 1994
Deck/Cargo
Issued 29 September 1994
Resolved
PRIOR TO CONDUCTING CARGO OPERATIONS, DEMONSTRATE CARGO MANIFOLD QUICK CLOSING VALVES AND CLOSURE INDICATORS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 29 September 1994
Resolved 29 September 1994
Deck/Cargo
Issued 29 September 1994
Resolved
DEMONSTRATE PROPER OPERATION AND CREW PROFICIENCY FOR VACUUM SENSOR ALARMS PRIOR TO LOADING CARGO.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Deck/Cargo
Issued 29 September 1994
Resolved
PRIOR TO CONDUCTING CARGO OPERATIONS, UNJAM PORT HOLE WINDOW ON STBD SIDE LIFEBOAT DECK AND CLOSE.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Deck/Cargo
Issued 29 September 1994
Resolved
PRIOR TO CONDUCTING CARGO OPERATIONS, DEMONSTRATE OPERATION OF WATER SPRAY SYSTEM ON DECK.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Documentation
Issued 29 September 1994
Resolved
PRIOR TO TRANSFERRING BUNKERS IN U.S. WATERS, DEVELOP THE REQUIRED OIL TRANSFER PROCEDURES IAW 33 CFR 155.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Navigation
Issued 29 September 1994
Resolved
PROVIDE SUPPLEMENT 13 TO BRITISH ADMIRALTY PUB. 69A.
Condition: Unknown
Due 29 September 1994
Resolved 29 September 1994
Unknown
Issued 29 September 1994
Resolved
PRIOR TO DEPARTURE PORT OF HOUSTON, PROPERLY DEMONSTRATE SATISFACTORY OPERATION OF THE 15 PPM ALARM ON THE OILY WATER SEPERATOR TO USCG.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Unknown
Issued 29 September 1994
Resolved
PRIOR TO DEPARTURE PORT OF HOUSTON, MAKE SATISFACTORY PERMANENT REPAIRS TO HYDRAULIC LINE PUMP CONTROL WHERE UNATTACHED AT SLOP TRUNK FWD.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Deck/Cargo
Issued 29 September 1994
Resolved
PRIOR TO NEXT U.S. PORT CALL, MAKE PERMANENT REPAIRS TO INERT GAS LINE AT COFFERDAM FWD OF SLOP TANK.
Condition: Unknown
Due 29 September 1994
Resolved 29 September 1994
Deck/Cargo
Issued 29 September 1994
Resolved
PRIOR TO CONDUCTING CARGO OPERATIONS, REPLACE MISSING VALVE WHEELS FOR NUMEROUS VALVES IN COMPRESSOR ROOM.
Condition: Unknown
Due 29 September 1994
Resolved 29 September 1994
Lifesaving
Issued 29 September 1994
Resolved
PRIOR TO DEPARTURE PORT OF HOUSTON, REPLACE/REPAIR COMPRESSED AIR HOSE LINEIN #1 LIFEBOAT WHERE KINKED.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Fire Fighting
Issued 29 September 1994
Resolved
PRIOR TO DEPARTURE PORT OF HOUSTON, PROVIDE BATTERIES FOR FLASHLIGHTS FOR EMERGENCY OUTFITS.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Fire Fighting
Issued 29 September 1994
Resolved
PRIOR TO DEPARTURE PORT OF HOUSTON, REPLACE BREATHING HOSE ON SCBA AT STATION #3.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Navigation
Issued 29 September 1994
Resolved
PRIOR TO DEPARTURE PORT OF HOUSTON, PERMANENTLY MARK POSITION OF RUDDER AT STEERING GEAR INSTALLATION.
Condition: Unknown
Due 29 September 1994
Resolved 29 September 1994
Documentation
Issued 29 September 1994
Resolved
PRIOR TO CONDUCTING CARGO OPERATIONS, PROVIDE COPY OF CLASS REPORTS REGARDING CORRECTION OF REQUIREMENTS FROM 29SEP94 LOC EXAMINATION.
Condition: Unknown
Due 29 September 1994
Resolved 29 September 1994
Documentation
Issued 29 September 1994
Resolved
PRIOR TO NEXT U.S. PORT CALL, AMEND OIL RECORD BOOK TO DOCUMENT ALL BUNKERING OPERATIONS.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Deck/Cargo
Issued 29 September 1994
Resolved
PRIOR TO CONDUCTING CARGO OPERATIONS, DEMONSTRATE THAT AIR LOCK DOOR IS AIRTIGHT.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Deck/Cargo
Issued 29 September 1994
Resolved
PRIOR TO CONDUCTING CARGO OPERATIONS, REINSTALL EMERGENCY SHUTDOWN UNIT ON PORT SIDE OF COMPRESSOR ROOM WHERE BROKEN OFF.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Lifesaving
Issued 29 September 1994
Resolved
PRIOR TO CONDUCTING CARGO OPERATIONS, PROVIDE REQUIRED WARNING SIGN FOR A COMPLEMENT OF 2. 1 SIGN TO BE POSTED AT GANGWAY AND 1 TO BE POSTED ON DECK.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Deck/Cargo
Issued 29 September 1994
Resolved
PRIOR TO CONDUCTING CARGO OPERATIONS, MAKE DOORS IN COMPRESSOR ROOM (PORT &STBD) WEATHER-TIGHT.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Lifesaving
Issued 29 September 1994
Resolved
PRIOR TO CONDUCTING CARGO OPERATIONS, RE-INSTALL ELECTRICAL JUNCTION AT FWDEND OF THE DECK WHERE BROKEN OFF.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Deck/Cargo
Issued 29 September 1994
Resolved
PRIOR TO CONDUCTING CARGO OPERATIONS, MAKE PERMANENT REPAIRS OR REPLACE PORTABLE OXYGEN ANALYZER AND DEMONSTRATE OPERATION AND PROFICIENCY. THIS UNIT IS TO BE OWNED BY OPERATOR OF SHIP.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Deck/Cargo
Issued 31 January 1994
Resolved
INSTALL REQUIRED STUD IN VAPOR COLLECTION SYSTEM FLANGE IN ACCORDANCE WITH TITLE 46 C.F.R. 39.20-1(E) PRIOR TO NEXT U.S. PORT CALL.
Condition: Unknown
Due 31 January 1994
Resolved 31 January 1994
Deck/Cargo
Issued 31 January 1994
Resolved
PRIVIDE A HIGH LEVEL ALARM WHICH INDICATES NOT LESS THAN 95% FOR CARGO TANKS IN ACCORDANCE WITH TITLE 46 C.F.R. 39.20-7(C)(1) OR PROVIDE A WAIVER FROM COMMANDANT U.S. COAST GUARD (G-MTH-3) FOR THE EXISTING ALARM SET TO 90% PRIOR TO NEXT U.S. PORT CALL.
Condition: Unknown
Due 31 January 1994
Resolved 31 January 1994
Lifesaving
Issued 10 February 1988
Resolved
PRIOR TO CARRYING GASES AND CHEMICALS AUTHORIZED BY IMOCOF ON BOARD IN US WATERS PROVIDE REQUIRED ANTIDOTES.
Condition: Unknown
Due 10 February 1988
Resolved 10 February 1988
Deck/Cargo
Issued 10 February 1988
Resolved
PRIOR TO CONDUCTING CARGO OPERATIONS IN US PORT PROVIDE AND DEMONSTRATE PROPER OPERATION OF PORTABLE COMBUSTIBLE GAS INDICATOR.
Condition: Unknown
Due 10 February 1988
Resolved 10 February 1988
Deck/Cargo
Issued 10 February 1988
Resolved
PRIOR TO CONDUCTING BUNKERING OPERATIONS IN US WATERS CLEAN ALL BUNKER VENTLINE FLAMESCREENS.
Condition: Unknown
Due 10 February 1988
Resolved 10 February 1988
Deck/Cargo
Issued 10 February 1988
Resolved
PRIOR TO ENTRY INTO US PORT DEMONSTRATE SATISFACTORY OPERATION OF FIXED GAS DETECTION SYSTEM UTILIZING SAMPLING POINT #10, LOWER SUCTION IN AIR LOCK.
Condition: Unknown
Due 10 February 1988
Resolved 10 February 1988
Deck/Cargo
Issued 10 February 1988
Resolved
PRIOR TO UTILIZING PORT CARGO MANIFOLD IN US PORTS DEMONSTRATE SATISFACTORYOPERATION OF AUTOMATIC QUICK CLOSING VALVE LOCATED IN WAY OF NUMBER ONE (1)VAPOR LINE.
Condition: Unknown
Due 10 February 1988
Resolved 10 February 1988
Deck/Cargo
Issued 10 February 1988
Resolved
PRIOR TO UTILIZING CARGO PUMPS IN US PORTS DEMONSTRATE SATISFACTORY OPER- ATION OF CARGO PUMP EMERGENCY SHUTDOWN SYSTEM.
Condition: Unknown
Due 10 February 1988
Resolved 10 February 1988
Documentation
Issued 10 February 1988
Resolved
PRIOR TO ENTRY INTO US PORT PROVIDE ON BOARD IMCO MEDICAL FIRST AID GUIDE.
Condition: Unknown
Due 10 February 1988
Resolved 10 February 1988
Documentation
Issued 16 December 1987
Resolved
SUBMIT COPIES OF NEW IMO COF'S (BOTH GAS & CHEM) TO G-MTH. OBTAIN AND PLACEABOARD NEW SOE.
Condition: Unknown
Due 16 December 1987
Resolved 16 December 1987
Documentation
Issued 24 April 1987
Resolved
OBTAIN AND PLACE ON BOARD NEW SUBCHAPTER "O" ENDORSEMENT.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987
Documentation
Issued 24 April 1987
Resolved
PRIOR TO CARRYING ANY CHEMICAL NLS CARGOES NOT ALREADY LISTED ON NLS CERT.,OBTAIN NEW CHEM COF REFERENCING MEPC20(22) AND TOTAL APPROVAL OF P&A MANUAL BY CLASS SOCIETY. SUBMIT COPY OF COF TO COMDT (GMTH) AND OBTAIN YET ANOTHER NEW SUBCHAPTER "O" ENDORSEMENT.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987
Documentation
Issued 6 April 1987
Resolved
UPON OBTAINING NEW IMO CERTIFICATE OF FITNESS (CHEMICAL) REFERENCING MEPC 20(22)SUBMIT A COPY TO COMMANDANT (G-MTH) AND OBTAIN A NEW SUBCHAPTER "O" ENDORSEMENT.
Condition: Unknown
Due 6 April 1987
Resolved 6 April 1987
Unknown
Issued 6 April 1987
Resolved
PRIOR TO CARRYING ANY CATEGORY A,B,C,OR D CHEMICAL CARGOES, OR ANY LIQUIFIED GAS CARGOES ALSO IN CATEGORY A,B,C,OR D, PROVIDE EVIDENCE OF COMPLIANCE WITH ANNEX II OF MARPOL 73/78 TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 6 April 1987
Resolved 6 April 1987
Lifesaving
Issued 22 February 1987
Resolved
PRIOR TO CARRYING AMMONIA IN U.S. WATERS, & PRIOR TO CONDUCTING TRANSFER OPERATIONS IN U.S. WATERS AFTER 31MAR87, PROVIDE 26 FIFTEEN MINUTE ESCAPE BREATHING APPARATUS, OR PROVIDE MANUFACTURER'S INFORMATION TO [name withheld],TX, SHOWING THAT FILTER MASKS ON BOARD ARE SUITABLE FOR---(CON'T NEXT ITEM)
Condition: Unknown
Due 22 February 1987
Resolved 22 February 1987
Lifesaving
Issued 22 February 1987
Resolved
AMMONIA AND ALL OTHER CARGOES WHICH REQUIRE EMERGENCY ESCAPE DEVICES BY IMO GAS SECTION 17.2.1 OR IMO CHEMICAL CODE SECTION 4.17, WHICH THE SHIP IS CERTIFIED TO CARRY.
Condition: Unknown
Due 22 February 1987
Resolved 22 February 1987