MAURY USCG vessel records Sign in
← All vessels

ADELIA

ADELIA is a 1971 tank ship. The Coast Guard has recorded 52 inspections since 1984, most recently in June 1999, along with 33 deficiencies and 2 operational controls.

Records from 1984 to 1999. Most recent: inspection, 24 June 1999.

Built
1971
Last inspected
24 June 1999
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7107699 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
PANAMA
—
Maury page id
psix-51740

Inspections, by type

…with no type recorded35
Years with a record 15 calendar years (1984–1999)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1950 - Regulatory (Subpart C or D), Net Ton
4205 - Dead Weight, Ton
3790 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 52

24 June 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 534646
28 May 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 429250
28 May 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 881493
23 December 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 423919
1 May 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 415479
31 March 1998 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 413920
31 March 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1124583
9 July 1997 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1114354
27 September 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 191917
27 September 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 757479
17 May 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 391372
27 April 1996 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 390456
27 April 1996 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1080151
2 July 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 530988
26 June 1995 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 379947
15 October 1994 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1181817
13 October 1994 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1177315
3 June 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 367460
8 October 1993 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1133762
5 October 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 361530
9 January 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 355305
26 September 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 353331
25 May 1992 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 956064
7 May 1992 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 949456
5 April 1992 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1259339
5 March 1992 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 349825
3 March 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 441769
8 November 1991 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 942233
21 August 1991 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1252737
3 July 1991 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 935858
8 February 1991 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1234283
29 October 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 466071
29 October 1990 MARPOL Annex II Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 924463
24 April 1990 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 899340
12 January 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 462275
18 July 1989 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 509256
5 April 1989 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 539400
5 April 1989 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1206297
13 December 1988 Administrative
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1209660
21 October 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 442277
3 August 1988 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1036763
8 April 1988 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1339957
7 April 1988 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 322502
2 October 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 539681
4 March 1987 Administrative
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1314407
3 March 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 314145
3 March 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1012038
4 February 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1319094
19 September 1986 Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1310789
29 January 1986 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 306694
29 January 1986 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1305184
23 June 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 528026

Deficiency record · 33

Fire Fighting
Issued 31 March 1998 Resolved
REMOVE LOCK ON FORWARD, STBD REMOTE CO2 ACTIVATION BOX AND INSTALL KEY BOX.
Condition: Unknown
Due 1 May 1998
Resolved 1 May 1998
Deck/Cargo
Issued 31 March 1998 Resolved
REPAIR/RENEW INERT GAS SYSTEM AND PROVIDE CLASS REPORT OF PROPER OPERATION.
Condition: Unknown
Due 1 May 1998
Resolved 1 May 1998
Engineering
Issued 27 April 1996 Resolved
Hydro test bunker piping to 1.5 times the maximum allowable working pressure as per 33 CFR 156.170(c). To be completed prior to bunkering in the U.S., or in any case NLT next U.S. voyage.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Lifesaving
Issued 27 April 1996 Resolved
Affix retro-reflective tape to bottom of port and starboard life boats as per SOLAS 74 amended III/30.2.7. To be completed prior to next U.S. voyage.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Accommodation/Occupational Safety
Issued 13 October 1994 Resolved
Repair battery room vent closure and demonstrate.
Condition: Unknown
Due 13 November 1994
Resolved 17 October 1994
Lifesaving
Issued 13 October 1994 Resolved
Repair hand holds on P & S lifeboats underwater hulls to the satisfaction of class society prior to departing the port of Jacksonville.
Condition: Unknown
Due 16 October 1994
Resolved 17 October 1994
Deck/Cargo
Issued 13 October 1994 Resolved
Repair broken piping hangers/brackets in cargo block, weather deck, prior to departing Jacksonville, FL.
Condition: Unknown
Due 16 October 1994
Resolved 17 October 1994
Fire Fighting
Issued 13 October 1994 Resolved
Demonstrate emergency fire pump operation, prior to departing the port of Jacksonville, FL.
Condition: Unknown
Due 16 October 1994
Resolved 17 October 1994
Deck/Cargo
Issued 13 October 1994 Resolved
Demonstrate inert gas system and alarms, shutdowns.
Condition: Unknown
Due 13 November 1994
Resolved 17 October 1994
Electrical
Issued 13 October 1994 Resolved
Repair broken electric bonding straps on cargo piping flanges, prior to loading cargo or transferring in U.S. waters.
Condition: Unknown
Due 16 October 1994
Resolved 17 October 1994
Deck/Cargo
Issued 8 October 1993 Resolved
PROVIDE TOXIC DRAGER TUBES FOR APPLICABLE CARGOES.
Condition: Unknown
Due 8 November 1993
Resolved 18 October 1993
Documentation
Issued 8 October 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 9 November 1993
Resolved 18 October 1993
Electrical
Issued 8 October 1993 Resolved
PERMANENTLY REPAIR EXPLOSION PROFF FITTING OUTSIDE FWD AIR LOCK WHERE CRACKED.
Condition: Unknown
Due 8 November 1993
Resolved 18 October 1993
Electrical
Issued 8 October 1993 Resolved
PERMANENTLY REPAIR EXPOSED WIRING FWD OF COMPRESSOR HOUSE.
Condition: Unknown
Due 8 November 1993
Resolved 18 October 1993
Electrical
Issued 8 October 1993 Resolved
PERMANENTLY REPAIR OR REMOVE DEAD ENDED WIRING WHERE OBSERVED FWD OF COMPRESSOR HOUSE.
Condition: Unknown
Due 8 November 1993
Resolved 18 October 1993
Lifesaving
Issued 8 October 1993 Resolved
REMOVE HOLD BACK DEVICE FROM FWD AIR LOCK AND INSTRUCT CREW NOT TO DISABLE SYSTEM IN WAY OF TOGGLE SWITCH.
Condition: Unknown
Due 8 November 1993
Resolved 18 October 1993
Deck/Cargo
Issued 8 October 1993 Resolved
DEMONSTRATE PROPER OPERATION OF GAS DETECTION SYSTEM SENSORS #1, 2, 4, 5, &7 AND EFFECT REPAIRS IN WAY OF #4 LPG ROOM SENSOR.
Condition: Unknown
Due 8 November 1993
Resolved 18 October 1993
Lifesaving
Issued 8 October 1993 Resolved
DEMONSTRATE AIR TIGHTNESS OF 2 WEATHER DECK AIR LOCKS OF 30 PSI HOSE TEST.
Condition: Unknown
Due 8 November 1993
Resolved 18 October 1993
Deck/Cargo
Issued 8 October 1993 Resolved
PERNANENTLY REPAIR HOLE FROM COMPRESSOR ROOM TO MOTER ROOM WHERE COMPRESSORSTART SWITH HAS BEEN REMOVED. _x001C_
Condition: Unknown
Due 8 November 1993
Resolved 18 October 1993
Fire Fighting
Issued 8 October 1993 Resolved
DEMONSTRATE PROPER OPERATION OF WATER SPRAY SYSTEM.
Condition: Unknown
Due 8 November 1993
Resolved 18 October 1993
Fire Fighting
Issued 8 October 1993 Resolved
PROVIDE 4 REQUIRED EMERGENCY OUTFITS.
Condition: Unknown
Due 8 November 1993
Resolved 18 October 1993
Engineering
Issued 8 October 1993 Resolved
REPAIR FLAME SCREEN IN WAY OF SETTING TANK PORT SIDE.
Condition: Unknown
Due 8 November 1993
Resolved 18 October 1993
Fire Fighting
Issued 8 October 1993 Resolved
REPAIR GENERAL ALARM IN WAY OF ER PORT SIDE ENTRANCE.
Condition: Unknown
Due 8 November 1993
Resolved 18 October 1993
Accommodation/Occupational Safety
Issued 8 October 1993 Resolved
HOSPITAL FACILITIES TO BE IN ACCORDANCE WITH THE STANDARDS OF ILO-147 CONVENTION.
Condition: Unknown
Due 8 November 1993
Resolved 18 October 1993
Navigation
Issued 7 May 1992 Resolved
Make permanent repairs to steering gear in way of hydraulic leaks and provide Classification society report of acceptance prior to next U.S. port.
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Deck/Cargo
Issued 7 May 1992 Resolved
Demonstrate proper operation of the Inert Gas System alarm panel in the Engine Room at the next U.S. port.
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Construction/Loadline
Issued 7 May 1992 Resolved
Make a midbody ballast tank available for internal examination at the next U.S. port.
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Navigation
Issued 5 March 1992 Resolved
A VIO OF 33 CFR 164.30 IN THAT THE VSL DID NOT HAVE O/B U.S. CHART #12222 OR IT'S FORREIGN EQUIV, WHICH WAS REQUIRED FOR THE VSL'S ROUTE FROM [VA CAPES/ WOLF TRAPS/ YORK SPIT CHANNEL/ FORT WOOL/ CRANEY ISLAND REACH] TO...
Condition: Unknown
Due 6 March 1992
Resolved 14 April 1992
Navigation
Issued 5 March 1992 Resolved
A VIO OF 33 CFR 164.30 IN THAT THE U.S. CHARTS # 12221, AND #12253 USED BY THE VSL WERE NOT CORRECTED TO NTM 46/91, WHICH WAS RESONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSL'S ROUTE FROM VA CAPES / WOLF TRAP
Condition: Unknown
Due 6 March 1992
Resolved 14 April 1992
Construction/Loadline
Issued 3 July 1991 Resolved
MAKE 1 BALLAST TANK IN MIDBODY AREA AVAILABLE FOR U.S. COAST GUARD INSPECTION AT NEXT U.S. PORT OF CALL.
Condition: Unknown
Due 3 July 1991
Resolved 3 July 1991
Electrical
Issued 8 April 1988 Resolved
INSTALL A FLOW SWITCH IN THE ELECTRIC MOTOR ROOM VENTILATION SUPPLY LINE ORA PRESSURE SWITCH IN THE ELECTRIC MOTOR ROOM TO SECURE NON-EXPLOSION PROOF ELECTRICAL EQUIPMENT IN THE ELECTRIC MOTOR ROOM.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Deck/Cargo
Issued 19 September 1986 Resolved
MAKE PERMANENT REPAIRS TO HIGH PRESSURE TO CROSS OVER (POS. NO. 2065 ON DRAWING # 92321) PRIOR TO ENTRY INTO U.S. WATERS AFTER 19SEP86.
Condition: Unknown
Due 19 September 1986
Resolved 19 September 1986
Deck/Cargo
Issued 19 September 1986 Resolved
PROVIDE CLASSIFICATION SOCIETY SURVEY REPORTS RE: REPAIRS TO HIGH PRESSURE TO CROSS OVER, TO COMDT (G-MTH-1) PRIOR TO ENTRY INTO U.S. WATERS AFTER 19SEP86.
Condition: Unknown
Due 19 September 1986
Resolved 19 September 1986

Ownership record