Records from 1984 to 1998. Most recent: inspection, 30 August 1998.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 25
30 August 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 419732
30 August 1998
Tank Vessel Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 797056
10 June 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 416571
5 June 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 421315
27 May 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 501401
27 May 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 537500
18 May 1998
Port Security Assessment
Type not classified · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 612957
18 May 1998
Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1127249
23 October 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 440723
23 October 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1200448
28 June 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 331197
25 April 1989
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1033759
20 April 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 514143
20 April 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1201278
16 September 1988
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 890785
8 August 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 444339
15 March 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1031135
17 July 1987
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 464838
15 April 1987
Certificate of Compliance
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1010029
13 April 1987
MARPOL Annex II Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1331374
10 April 1987
Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1330638
19 January 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1316641
8 April 1986
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 307959
21 November 1985
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1301203
18 October 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974928
Lifesaving
Issued 30 August 1998
No resolution recorded
REPLACE WORN STEAM LOW PRESSURE RETURN LINE FLANGES ON WEATHER DECK IN DRYDOCK IN EARLY OCTOBER. SOLAS 60 CH. II, REG.29 (c)(ii).
Condition: Unknown
Due 10 October 1998 — due date passed with no resolution recorded
Navigation
Issued 30 August 1998
No resolution recorded
HAVE CLASS SOCIETY ATTEST TO INCONSISTENCY/SLUGGISHNESS WITH MAIN STEERING GEAR WHEN BOTH PUMPS ARE ON LINE & USED TOGETHER FOR STEERING VSL. TO BE DONE BY DRYDOCK. VESSEL'S STEERING VIA EACH OF TWO PUMPS FOUND SAT. 35 - 30IN 29 SECONDS, PROBLEM SEEN ONLY WHEN BOTH PUMPS ARE USED IN CONJUNCTION.
Condition: Unknown
Due 10 October 1998 — due date passed with no resolution recorded
Lifesaving
Issued 30 August 1998
No resolution recorded
IN DRYDOCK EFFECT PERMANENT REPAIRS TO SMALL PIN HOLES FOUND IN MIDSHIP PUMPROOM VENTILATION DUCTING IN LOWER SECTION OF DUCTING.
Condition: Unknown
Due 10 October 1998 — due date passed with no resolution recorded
Deck/Cargo
Issued 10 June 1998
Resolved
REPAIR AND PROVE OPERATION OF THE 95% HIGH LEVEL ALARMS FOR NUMBER 2 PORT &STARBOARD CARGO TANKS.
Condition: Unknown
Due 31 August 1998
Resolved 31 August 1998
Engineering
Issued 18 May 1998
Resolved
PROVE PROPER OPERATION OF THE OIL WATER SEPERATOR.
Condition: Unknown
Due 31 August 1998
Resolved 31 August 1998
Navigation
Issued 18 May 1998
Resolved
RUDDER ANGLE INDICATOR HAD A FIVE DEGREE ERROR BETWEEN THE STEERING COMPARTMENT AND THE BRIDGE. SOLAS V-19-2(VI)/33CFR 164.25(B)(1)(IV)
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Construction/Loadline
Issued 18 May 1998
Resolved
SEA WATER LEAK, BALLAST SYSTEM ON THE SEA WATER SUCTRION LINE #1 IN THE FORWARD PUMP ROOM.
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Lifesaving
Issued 18 May 1998
Resolved
THE SIX MAN LIFE RAFT REQUIRED FORWARD IS MOUNTED ON THE MIDSHIP DECK HOUSE. SOLAS
Condition: Unknown
Due 31 August 1998
Resolved 31 August 1998
Deck/Cargo
Issued 18 May 1998
Resolved
SOFT PATCH ON VENT RISER ON CARGO TANK #9 STARBOARD.
Condition: Unknown
Due 31 August 1998
Resolved 31 August 1998
Engineering
Issued 18 May 1998
Resolved
HYFRAULIC LEAK IN FORWARD COFFERDAM.
Condition: Unknown
Due 31 August 1998
Resolved 31 August 1998
Engineering
Issued 18 May 1998
Resolved
HYDRAULIC OIL IN BILGE OF COFFERDAM.
Condition: Unknown
Due 31 August 1998
Resolved 31 August 1998
Lifesaving
Issued 18 May 1998
Resolved
NO GENERAL ALARMS ON THE MAIN DECK OUTSIDE THE SUPER STRUCTURE. SOLAS 74 CH III REG 50
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Deck/Cargo
Issued 18 May 1998
Resolved
TEN OF THE TWENTY SIX TANK LEVEL ALARMS DO NOT WORK. 46 CFR 153.406/ IBC 18.8.6
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Lifesaving
Issued 18 May 1998
Resolved
NO ALARM PULL BOXES IN ANY MAIN DECK COMPARTMENTS FORWARD OF THE SUPER STRUCTURE.
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Engineering
Issued 18 May 1998
Resolved
MALFUNCTION OF PROPULTION
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Lifesaving
Issued 18 May 1998
Resolved
THE LIFEBOATS HAVE AN AFTER MARKET ENCLOSURE ADDED TO AN OPEN LIFE BOAT, WHICH DOES NOT HAVE AN EXTERIOR SPRAY WATER SYSTEM. SOLAS 74 CHIII REG 41/46.
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Fire Fighting
Issued 18 May 1998
Resolved
THE SHIP DOES NOT HAVE A FOAM FIRE FIGHTING SYSTEM OR A LETTER OF CLASS ACCEPATANE FOR THE DRY CHEMICAL SYSTEM INSTALLED. (FIRE PROTECTION FOR FLAMMABLE LIQUID CARGOES MTBE/BENZENE)
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Deck/Cargo
Issued 18 May 1998
Resolved
CARGO PUMPS EMERGENCY STOPS DO NOT WORK. 46 CFR 153.296 / 33 CFR 155.780
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Deck/Cargo
Issued 18 May 1998
Resolved
CARGO TANK #1 PORT AND STBD HIGH LEVEL ALARMS WIRES WERE EXPOSED.
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Accommodation/Occupational Safety
Issued 18 May 1998
Resolved
PLASTIC GARBAGE MIXED IN WITH FOOD WASTE, NO PLASTIC STORAGE AREA.
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Construction/Loadline
Issued 18 May 1998
Resolved
SEA WATER LEAK IN AFT PUMP ROOM BILGE SUCTION VALVE LINE OUTBOARD OF THE SKIN VALVE. SOLAS 74 CHI REG 11
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Deck/Cargo
Issued 18 May 1998
Resolved
OPA 90 RESPONSE GEAR, SHOVELS WERE MADE OF STEEL.
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Construction/Loadline
Issued 18 May 1998
Resolved
REACH RODS FOR BILGE EDUCTOR SYSTEM IN THE AFT PUMP ROOM WERE DISCONNECTED FROM THE VALVES. SOLAS 74 CH II REG46.3
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Deck/Cargo
Issued 18 May 1998
Resolved
CARGO PIPE LEAK FROM PORT SIDE IN THE PIPE ELBOW ABOVE EIGHT STARBOARD CARGO TANK. ISGOTT3.1.3
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Deck/Cargo
Issued 18 May 1998
Resolved
THE PORTABLE EXPLOSIVE METERS AND CARGO VAPOR DETECTION METERS WERE INOPERABLE. 46 CFR 153.526(A).
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Accommodation/Occupational Safety
Issued 18 May 1998
Resolved
THE RAILING ABOVE THE STARBOARD MAIFOLD WAS BROKEN, 10FOOT SECTION. ILO147
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Accommodation/Occupational Safety
Issued 18 May 1998
Resolved
NO HOT WATER IN THE HOSPITAL. ILO 147
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Lifesaving
Issued 18 May 1998
Resolved
STARBOARD LIFE BOAT HAS CRACKS IN UPPER SHELL, 2 HOLES IN HULL TOP PORT GUNNAL, AND THE BOW.
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Lifesaving
Issued 18 May 1998
Resolved
SPARK PRODUCING DEVICES ON MAIN DECK.
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Accommodation/Occupational Safety
Issued 18 May 1998
Resolved
NO HOT WATER IN CREWS HEAD/SHOWER. ILO147.
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Accommodation/Occupational Safety
Issued 18 May 1998
Resolved
LIFELINE AT CONTROL MANIFOLD IS 1/4" NYLON LINE. ILO 147
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Electrical
Issued 18 May 1998
Resolved
EXPOSED ELECTRICAL CONNECTION ON HIGH LEVEL ALARMS ON DECK.
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Deck/Cargo
Issued 18 May 1998
Resolved
HOLE IN VENT RISER ON CARGO TANK 11 STARBOARD.
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Deck/Cargo
Issued 20 April 1989
Resolved
MAKE PERMANENT REPAIRS TO PORTABLE MANIFOLD HEADER AND HYDRO TO THE ATTENDING CLASS SOCIETY SURVEYOR (DNV) SATISFACTION. (HEADER DEVELOPED PIN HOLE LEAK DURING TRANSFER).
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Fire Fighting
Issued 20 April 1989
Resolved
MARK FOREPEAK HOSE FILL CONNECTION "NOT A FIRE STATION"
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Deck/Cargo
Issued 20 April 1989
Resolved
ENSURE DISCHARGE CONNECTIONS ARE OVER CONTAINMENT 100%.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Electrical
Issued 20 April 1989
Resolved
PROVIDE COVER FOR PNEUMATIC VALVE CONTROL BOX IN MIDSHIP PUMPROOM.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Fire Fighting
Issued 20 April 1989
Resolved
PROVIDE STRAP FOR DRY CHEM AIR BOTTLE IN FOC'SLE.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Navigation
Issued 20 April 1989
Resolved
PROVIDE CLAPPER FOR SHIP'S BELL.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Documentation
Issued 15 March 1988
Resolved
VESSEL REQUIRED TO SUBMIT IMO CERTIFICATE OF FITNESS TO USCG COMMANDANT GMTH-1 AND OBTAIN A NEW SUBCHAPTER "O" ENDORSEMENT.
Condition: Unknown
Due 15 March 1988
Resolved 15 March 1988
Accommodation/Occupational Safety
Issued 15 March 1988
Resolved
AFT EYE-WASH STATION IS IN NEED OF REPAIRS.
Condition: Unknown
Due 15 March 1988
Resolved 15 March 1988
Unknown
Issued 21 November 1985
Resolved
PROVIDE ONBOARD THE VESSEL A VALID CARGOES AND RESTRICTIONS LIST ISSUED BY COMDT G-MTH-1.
Condition: Unknown
Due 21 November 1985
Resolved 21 November 1985