MAURY USCG vessel records Sign in
← All vessels

BOW ORION

BOW ORION is a 1977 tank ship. The Coast Guard has recorded 70 inspections since 1984, most recently in July 2007, along with 38 deficiencies — 1 with no resolution recorded — and 4 operational controls.

Records from 1984 to 2007. Most recent: inspection, 13 July 2007.

Built
1977
Last inspected
13 July 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7384883 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
PANAMA
—
Maury page id
psix-51750

Inspections, by type

…with no type recorded51
…past their stated due date1
Years with a record 20 calendar years (1984–2007)
The 70 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11350 - Convention (Subpart B), Net Ton
10152 - Regulatory (Subpart C or D), Net Ton
28085 - Dead Weight, Ton
17561 - Convention (Subpart B), Gross Ton
16595 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 70

13 July 2007 PII Safety Exam · ISPS III Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2993913
5 July 2007 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2984473
22 May 2007 Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2935169
21 August 2003 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1882833
27 January 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1736045
3 January 2003 Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1728045
1 January 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1725118
18 December 2002 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1720838
15 December 2002 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1728059
20 August 2002 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1664060
12 August 2002 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1660510
18 April 2002 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1606221
13 March 2002 Ballast Water Examination · Letter of Compliance (Initial/Renewal)
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1492760
19 August 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 281111
19 August 2000 Letter of Compliance (Initial/Renewal)
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 821383
22 November 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 669662
30 October 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 16990
19 April 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 427515
8 May 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 415858
8 May 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1468857
28 April 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 415375
6 February 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 400271
21 January 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 528322
6 November 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 396881
6 November 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 669664
4 November 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 49751
3 September 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 395003
27 August 1996 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 394558
10 July 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 393141
3 July 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 392954
28 June 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 392719
28 June 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1085262
15 July 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 380608
11 May 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 378284
10 May 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 506941
5 December 1994 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 372847
26 September 1994 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1172835
10 March 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 486284
24 February 1994 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 468073
1 November 1993 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 838128
21 July 1993 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1155324
19 July 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 359788
9 July 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 492859
25 November 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 354658
29 August 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 956369
14 August 1992 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 352555
12 August 1992 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 446326
12 August 1992 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1262289
30 October 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 442057
12 August 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 646211
4 July 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 484641
2 July 1991 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 933204
21 February 1991 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 507539
16 September 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 529922
29 March 1990 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 903657
20 June 1989 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 461410
18 March 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 897022
12 December 1988 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 509984
11 March 1988 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1033315
19 December 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 320342
19 December 1987 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1314143
29 June 1987 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1010492
27 June 1987 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 497421
12 June 1987 Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1029810
11 May 1987 MARPOL Annex II Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1328547
17 November 1986 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 312778
1 August 1986 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 461838
19 March 1986 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 307569
24 October 1985 MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 992234
17 September 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 461923

Deficiency record · 38

Lifesaving › Lifeboat › Hull
Issued 22 May 2007 Resolved
Port and Starboard Lifeboats have multiple holes in the hull along keel, allowing free communication with the sea. Lifeboats are not ready for use. The condition of the boats pose a safety hazard to the crew if used. Ship Detained. Resolve to the satisfaction of Class Surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2007
Resolution: Deficiency withdrawn upon Class Verification that lifeboats have been accepted by Classification Society and Flag State. DNV has no records that lifeboats have been modified.
Construction/Loadline › Structures › Superstructure
Issued 22 May 2007 Resolved
The following watertight openings to the superstructure of the ship are not able to close properly, compromising the watertight integrity of the vessel. Port Side Aft Access, Emergency Diesel Generator Space Entrance, Battery Room Door, Changing Room Access Door, Fantail Portside Hatchway, Window Aft of Rear Access. (See narrative for more complete information). Vessel Detained. Sat. of Class
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2007
Resolution: Received Class Report attesting to proper repairs. See scanned document for further clarification.
Construction/Loadline › Penetrations › Gasket
Issued 22 May 2007 Resolved
Gaskets for all tank hatches are unaligned and worn past serviceability, compromising the watertight integrity and cargo integrity of the vessel. Vessel Detained. Repair to the staisfaction of Class Surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2007
Resolution: Recieved Class Report attesting to proper repairs. See scanned document for further clarification.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 22 May 2007 Resolved
The Oily Water Seperator (OWS) does not operate properly. There is a leak on the 15ppm OWS access port which spews out water during operation. Repair prior to departure to the satisfaction of attending Class Surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2007
Resolution: Received Class Report attesting to proper repairs. See scanned document for further clarification.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 22 May 2007 Resolved
Calibrate the oil contaent meter to ensure shutdown of discharge pump at 15 ppm. Prior to departure from port to the satisfaction of attending Class Surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2007
Resolution: Received Class Report attesting to proper repairs. See scanned document for further clarification.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 22 May 2007 Resolved
Piping for the Nitrogen Gas Generator System for cargo integrity on deck is non-ferrous and contains several soft patches. Correct to the satisfaction of Class prior to loading cargos that require inerting. Correct to the satisfaction of Class prior to loading cargo in the United States.
Action required: 705 - Other - as specified
Resolved 24 May 2007
Resolution: Received Class Report attesting that nitrogen plant has been taken out of use. Before commission to be surveyed by DNV. See scanned document for further clarification.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 22 May 2007 Resolved
#9 Center cargo Tank Vapor Line contains a soft patch at the joint for the cargo ullage tank. Correct prior to loading cargo in the United States to the satisfaction of Class
Action required: 705 - Other - as specified
Resolved 24 May 2007
Resolution: Received Class Report attesting to proper repairs. See scanned document for further clarification.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 22 May 2007 Resolved
Hydraulic High Pressure Lines for cargo pumps have minor leaks at flanges. Repair to the satisfaction of attending Class Surveyor prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2007
Resolution: Received Class Report attesting to proper repairs. See scanned document for further clarification.
Engineering › Generator (propulsion-electric) › Receptacle
Issued 22 May 2007 Resolved
Ship’s Service Generators drain lines have been replaced with rubber hose creating a fire hazard, melting hazard, as well as a pollution hazard. Repair prior to departure to the satisfaction of Class Surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2007
Resolution: Received Class Report attesting to proper repairs. See scanned document for further clarification.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Combustible Gas Indicator
Issued 22 May 2007 Resolved
Portable Gas Detection Devices are not onboard. Servicing facility is to attest to proper operation. Prior to departure to the satisfaction of Coast Guard
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2007
Resolution: 2 sets of multiple gas portable unitis in servicing facility for calibration and not on board during COC exam. They have been returned to the vessel.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 22 May 2007 Resolved
Cargo piping tested to 10 Bar, which is the reported Maximum Allowable Working Pressure (MAWP) reported by the crew. Identify correct MAWP for cargo pumps and complete hydrostatic tests of cargo piping at 1.5 times MAWP. Cargo Pump operations limited to a maximum pressure of 5 Bar until deficiency is cleared. Resolve prior to departure to the satisfaction of Class Surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2007
Resolution: Received Class Report attesting to proper repairs. See scanned document for further clarification.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 22 May 2007 Resolved
Rudder Angle Indicator (RAI) on Navigation Bridge does not read the same as the RAI on the steering, the readingsvary from 2 degrees to 5 degrees difference. Repair prior to departure to the satisfaction of attending Class Surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2007
Resolution: Received Class Report attesting to proper repairs. See scanned document for further clarification.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 22 May 2007 Resolved
There was no Loss of Power Audio or Visual Alarm on the Navigation Bridge when loss of power for the steering gear was stimulated. (The ship has the capability to produce these alarms). Repair to the satisfaction of Class Surveyor prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2007
Resolution: Received Class Report attesting to proper repairs. See scanned document for further clarification.
Documentation › Certificates/Documents › IOPP Certificate
Issued 22 May 2007 Resolved
Maximum throughput of the OWS is missing from the IOPP. Prior to departure from port to the satisfaction of Class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2007
Resolution: Received Class Report attesting to proper repairs. See scanned document for further clarification.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 22 May 2007 Resolved
Safety Management System (SMS)not implemented. Vessel failed to document and report non-conformities IAW SMS Procedures. Deficiencies noted aboard the vessel such as wasted doors on the weather deck, soft patches on piping, steering alarms, and rudder angle indicator accuracy were acknowledged to not be functioning by crew.Non conformity reports were not filed IAW SMS.Recommend audit of SMS by RO.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2007
Resolution: Additional ISM audit completed 2 Observations issued, see scanned document.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 22 May 2007 No resolution recorded
Inert gas system has been taken out of operation. Vessel not permitted to transfer hazardous cargo without proper operation of IGS. Classification Society issued Condition of Class indicating which cargos will be carried by the vessel.
Action required: 705 - Other - as specified
Due 24 May 2009 — due date passed with no resolution recorded
Electrical › Lighting (service)
Issued 13 March 2002 Resolved
Glass globe on light for paint locker is cracked and therefore not exposion proof. Replace globe before next US port after April 2002 drydock.
Condition: Improper/Lack of Maintenance
Due 1 May 2002
Resolved 12 August 2002
Resolution: Glass globe repaired.
Deck/Cargo › Marine Portable Tanks
Issued 13 March 2002 Resolved
Acetylene and oxygen bottles are stored together. Acetylene bottles must be stored separate from oxygen bottles prior to next US port after April 2002 drydock.
Due 1 May 2002
Resolved 12 August 2002
Resolution: Less than 8 cylinders were stored and are allowed as per their countys'' regulations provide in case package.
Fire Fighting
Issued 19 April 1999 Resolved
One CO2 bottle discharge line was found fractured. The fractured dischargeline was located on the CO2 bottle in the 4th column of bottles left from starboard on the 11th bottle aft.
Condition: Unknown
Due 19 April 1999
Resolved 27 April 1999
Navigation
Issued 28 April 1998 Resolved
Secondary radar inop. 33CFR164.
Condition: Unknown
Due 30 April 1998
Resolved 1 May 1998
Deck/Cargo
Issued 28 June 1996 Resolved
Prior to using Vapor Control System (VCS) demonstrate vapor overpressure_x001C_ and vacuum alarms to U.S. Coast Guard, as per 46 CFR 39.20-13.
Condition: Unknown
Due 28 June 1996
Resolved 5 July 1996
Deck/Cargo
Issued 28 June 1996 Resolved
Demonstrate an audible alarm for high/low vapor pressure as per _x001C_ 46CFR39.20-13.
Condition: Unknown
Due 3 September 1996
Resolved 3 September 1996
Deck/Cargo
Issued 28 June 1996 Resolved
Hydrostatically test cargo hoses 3, 6-9, and 11-16. Provide documentation to U.S. Coast Guard. Hoses are not to be used until test of hoses are _x001C_ completed, as per 33 CFR 156.170 (f)(2).
Condition: Unknown
Due 11 July 1996
Resolved 11 July 1996
Lifesaving
Issued 28 June 1996 Resolved
Professionally service self contained breathing apparatus (SCBA's). Provide service report to U.S. Coast Guard, as per IBC 14.2.6._x001C_
Condition: Unknown
Due 11 July 1996
Resolved 11 July 1996
Deck/Cargo
Issued 28 June 1996 Resolved
Demonstrate proper use of oil discharge monitoring equipment (ODME). Provide class survey report to U.S. Coast Guard, as per 33 CFR 157.37.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Documentation
Issued 15 July 1995 Resolved
VESSEL USER FEE PAYMENT UNPAID.
Condition: Unknown
Due 19 July 1995
Resolved 28 July 1995
Deck/Cargo
Issued 11 May 1995 Resolved
TEST PRESSURE VACUUM RELIEF VALVES AS REQUIRED BY 33CFR4156.170. PROVIDE LOCAL COAST GUARD WITH COPY OF RESULTS.
Condition: Unknown
Due 18 July 1995
Resolved 18 July 1995
Deck/Cargo
Issued 11 May 1995 Resolved
HYDROSTATICALLY TEST ALL VAPOR COLLECTION HOSES TO 1 & 1/2 MAWP AS PER 33CFR156.170. PROVIDE LOCAL COAST GUARD WITH COPY OF RESULTS.
Condition: Unknown
Due 18 July 1995
Resolved 18 July 1995
Engineering
Issued 2 July 1991 Resolved
INSTALL AN AUDIBLE AND VISUAL ALARM IN THE ENGINE ROOM FROM THE OIL WATER SEPARATOR PRIOR TO NEXT U. S. PORT CALL.
Condition: Unknown
Due 2 July 1991
Resolved 2 July 1991
Deck/Cargo
Issued 19 December 1987 Resolved
THE WARNING SIGN REQUIRED BY 46 CFR 153.955(A) WAS NOT DISPLAYED FACING OUTBOARD TOWARD THE WATER.
Condition: Unknown
Due 19 December 1987
Resolved 19 December 1987
Navigation
Issued 19 December 1987 Resolved
CHARTS 12331 (23RD ED.) 12333 (24TH ED.) NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 19 December 1987
Resolved 19 December 1987
Deck/Cargo
Issued 19 December 1987 Resolved
REPAIR CLOSED GAUGING TO #4CD, #65W CARGO TANKS PRIOR TO LOADING CARGO REQUIRING CLOSED GAUGING.
Condition: Unknown
Due 19 December 1987
Resolved 19 December 1987
Deck/Cargo
Issued 19 December 1987 Resolved
PROPERLY BLANK-OFF REMOVED VENT TO SAMPLE ROOM AT NEXT GAS FREE CONDITION OF VESSEL
Condition: Unknown
Due 19 December 1987
Resolved 19 December 1987
Fire Fighting
Issued 19 December 1987 Resolved
PROVE PROPER OPERATION OF MAIN FIRE PUMP.
Condition: Unknown
Due 19 December 1987
Resolved 19 December 1987
Unknown
Issued 29 June 1987 Resolved
CONDUCT 1-1/2 MAWP PIPING TEST ON CARGO PIPING AS PER 33CFR156.170.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Unknown
Issued 29 June 1987 Resolved
REPAIR THE CLOSED GAUGING DEVICES TO 4CP, 6SW, 7SW, PRIOR TO LOADING ANY CARGOES REQUIRING CLOSED GAUGING IN THOSE TANKS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Unknown
Issued 29 June 1987 Resolved
REPAIR OR REMOVE WASTED VENT DUCT IN CARGO SAMPLE ROOM.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Documentation
Issued 11 May 1987 Resolved
SUBMIT COPY OF NEW IMO COF TO COMT (G-MTH). PLACE ON BOARD A NEW SOE.
Condition: Unknown
Due 11 May 1987
Resolved 11 May 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.