Records from 1985 to 1997. Most recent: inspection, 7 June 1997.
Inspection history · 75
7 June 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 404439
7 June 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 773670
3 May 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 493523
1 April 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 402112
19 November 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 397670
15 August 1996
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 394356
30 July 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 393581
15 March 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 389025
12 January 1996
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 386719
1 August 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 381187
20 July 1995
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 380658
5 July 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 199378
5 July 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 753113
5 June 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 379272
5 June 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1185343
17 January 1995
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 374282
30 December 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 183556
8 December 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 677688
30 November 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 171548
17 November 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 372777
29 September 1994
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 528624
2 September 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 370279
16 August 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 867292
8 July 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1429929
4 June 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1466881
25 May 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 859588
21 April 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 366303
30 March 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 8677
21 March 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 365337
7 March 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 366559
10 February 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 364419
20 October 1993
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1149539
14 October 1993
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 832969
28 June 1993
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 844068
3 June 1993
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1134947
23 March 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 503758
10 February 1993
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1139712
2 January 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 130893
26 September 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 353221
29 June 1992
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1255014
20 June 1992
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1259050
16 May 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 478720
16 November 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 932358
13 November 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 941408
8 October 1991
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1246361
12 September 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 677689
23 June 1991
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 903302
14 June 1991
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 911105
14 June 1991
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1217045
18 January 1991
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1221868
16 October 1990
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1215830
3 October 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 931047
28 September 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 339595
28 September 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1220131
11 April 1990
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 519510
9 October 1989
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 466217
8 July 1989
Certificate of Compliance · MARPOL Annex II Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 894035
4 January 1989
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 499200
4 November 1988
Administrative
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 890326
15 October 1988
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1199368
30 August 1988
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1348169
18 July 1988
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1339371
8 July 1988
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 900593
6 July 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 495618
6 July 1988
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 897431
22 March 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 322130
22 March 1988
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1213634
10 March 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 321886
25 January 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 503249
1 September 1987
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 318192
24 July 1987
Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1021497
22 July 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 522743
1 July 1987
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 317029
1 July 1987
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1011153
26 March 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 301212
Accommodation/Occupational Safety
Issued 30 July 1996
Resolved
PROVIDE FLUSH SYSTEM FOR CREWS TOILETS. ILO-147_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 August 1996
Resolved 15 August 1996
Accommodation/Occupational Safety
Issued 30 July 1996
Resolved
PROVIDE UNOCCUPIED HOSPITAL SPACE PRIOR TO NEXT U.S. PORT. ILO-147
Condition: Unknown
Due 15 August 1996
Resolved 15 August 1996
Deck/Cargo
Issued 30 July 1996
Resolved
PROVIDE DOCUMENTATION THAT THE VESSEL'S CARGO P/V VALVES HAVE BEEN PROFESSIONALLY SERVICED. 33CFR156.170._x001C_
Condition: Unknown
Due 15 August 1996
Resolved 15 August 1996
Navigation
Issued 30 July 1996
Resolved
PROVIDE CORRECT MAGNETIC DEVIATION COMPASS CARD. 33CFR164.35_x001C_
Condition: Unknown
Due 15 August 1996
Resolved 15 August 1996
Accommodation/Occupational Safety
Issued 30 July 1996
Resolved
PROVIDE BERTHING LIGHTS WITH PROTECTIVE COVERING. ILO-147
Condition: Unknown
Due 7 May 1997
Resolved 7 May 1997
Electrical
Issued 30 July 1996
Resolved
REPAIR DECK LIGHTING, SPECIFICALLY; MISSING MAST HEAD DECK LIGHT COVERS; MISSING MIDSHIP STARBOARD GLOBE; EXTINGUISHED CARGO SAMPLE LOCKER LIGHT. BCH 3/3.
Condition: Unknown
Due 15 August 1996
Resolved 15 August 1996
Deck/Cargo
Issued 30 July 1996
Resolved
PROVIDE VCS MANIFOLD VALVES WITH OPEN/CLOSED INDICATIONS. 46CFR39-20-1.
Condition: Unknown
Due 15 August 1996
Resolved 15 August 1996
Navigation
Issued 30 July 1996
Resolved
ALIGN BRIDGE WING REPEATERS WITH GYRO. 33CFR164.35_x001C_
Condition: Unknown
Due 15 August 1996
Resolved 15 August 1996
Engineering
Issued 20 July 1995
Resolved
S.W. OVERBOARD HEAD TO PITCH PROPELLER COOLER HAS TEMPORARY PATCH. BEFORE_x001C_VSL DEPARTS NEXT U.S. PORT, VSL'S CLASS SOCIETY TO ATTEST TO THE_x001C_ CONDITION & SERVICABILITY OF THIS TEMPORARY REPAIR.
Condition: Unknown
Due 1 August 1995
Resolved 1 August 1995
Engineering
Issued 20 July 1995
Resolved
OVERBOARD DISCHARGE FROM PORT & STBD M/E F.W. COOLERS HAS TEMPORARY_x001C_ PATCHES. PRIOR TO DEPARTING NEXT U.S. PORT PERMANENT REPAIRS ARE TO BE MADE & VSL'S CLASS SOCIETY IS TO ATTEST TO ITS CONDITION & SERVICABILITY.
Condition: Unknown
Due 1 August 1995
Resolved 1 August 1995
Construction/Loadline
Issued 20 July 1995
Resolved
OVERBOARD BILGE DISCHARGE LOCATED ON STBD SIDE OF E/R HAS TEMPORARY PATCH._x001C_PRIOR TO DEPARTING NEXT U.S. PORT PERMANENT REPAIRS ARE TO BE MADE & VSL'S_x001C_CLASS SOCIETY IS TO ATTEST TO ITS CONDITION & SERVICABILITY.
Condition: Unknown
Due 1 August 1995
Resolved 1 August 1995
Deck/Cargo
Issued 5 June 1995
Resolved
REPLACE P/V VALVE FLAME SCREEN AND RAIN SHIELD ON #4S CARGO TANK PRIOR TO CARGO OPERATIONS.
Condition: Unknown
Due 5 July 1995
Resolved 20 June 1995
Documentation
Issued 5 June 1995
Resolved
PRIOR TO USING VCS SYSTEM, INCORPORATE VCS INFORMATION IN OIL TRANSFER PROCEDURES. PROVIDE LOCAL COAST GUARD WITH CLASS SOCIETY SURVEYOR'S REPORT.33 CFR 155.750.
Condition: Unknown
Due 1 August 1995
Resolved 1 August 1995
Deck/Cargo
Issued 5 June 1995
Resolved
PRIOR TO LOADING CARGOES REQUIRING CARGO HIGH LEVEL ALARM OR CARGO OVERFILLALARM , REPAIR #2S OVERFILL ALARM AND #6P HIGH LEVEL ALARM AND DEMONSRATE _x001C_SATISFACTORY OPERATION TO CLASS. PROVIDE COAST GUARD WITH CLASS REPORT.
Condition: Unknown
Due 5 July 1995
Resolved 20 June 1995
Engineering
Issued 5 June 1995
Resolved
REPLACE SAFEPAK SWITCH ON OILY WATER SEPERATOR. DEMONSTRATE PROPER OPERATION OF OILY WATER SEPERATOR AUTOMATIC STOPPING DEVICE TO CLASS. PROVIDE COAST GUARD WITH SURVEYOR'S REPORT.
Condition: Unknown
Due 21 July 1995
Resolved 21 July 1995
Documentation
Issued 5 June 1995
Resolved
PROVIDE MEDICAL EXAMINATION DOCUMENTATION FOR ALL ABLE SEAMEN AND 3RD OFFICER TO LOCAL COAST GUARD.
Condition: Unknown
Due 5 July 1995
Resolved 20 June 1995
Documentation
Issued 5 June 1995
Resolved
COMPLETED PAGES IN OIL RECORD BOOK MUST BE SIGNED BY MASTER.
Condition: Unknown
Due 5 June 1995
Resolved 8 June 1995
Lifesaving
Issued 5 June 1995
Resolved
PROVIDE NEW LIFE JACKET WITH WHISTLE FOR FITTER. AFFIX WHISTLE AND LIGHT TOMESSMEN'S LIFEJACKET. PROVIDE LOCAL COAST GUARD WITH COPY OF INVOICE OR STATEMENT FROM MASTER.
Condition: Unknown
Due 5 June 1995
Resolved 8 June 1995
Navigation
Issued 5 June 1995
Resolved
INSTALL COTTER PINS IN LINKAGE CONNECTIONS ON STEERING GEAR SYSTEM
Condition: Unknown
Due 5 July 1995
Resolved 20 June 1995
Electrical
Issued 5 June 1995
Resolved
REPLACE AUTOMOTIVE BATTERY WITH APPROPRIATE MARINE TYPE BATTERY FOR EMERGENCY BATTERY SYSTEM TO SATISFACTION OF CLASS. PROVIDE SURVEYOR'S REPORT TO COAST GUARD.
Condition: Unknown
Due 5 July 1995
Resolved 20 June 1995
Engineering
Issued 5 June 1995
Resolved
RENEW ALL FLAME SCREENS ON FUEL OVERFLOW VENTS.
Condition: Unknown
Due 21 July 1995
Resolved 21 July 1995
Deck/Cargo
Issued 5 June 1995
Resolved
PRIOR TO CONDUCTING CARGO OPERATIONS, IDENTIFY WASTED PIPELINE ON MAIN DECKIN WAY OF #2C NOTIFY LOCAL COAST GUARD.
Condition: Unknown
Due 5 July 1995
Resolved 20 June 1995
Deck/Cargo
Issued 5 June 1995
Resolved
PRIOR TO USING VAPOR COLLECTION SYSTEM, MAKE MANIFOLD FLANGE STUD PERMANENTLY AFFIXED. PROVIDE LOCAL COAST GUARD WITH CLASS REPORT.
Condition: Unknown
Due 21 July 1995
Resolved 21 July 1995
Deck/Cargo
Issued 5 June 1995
Resolved
REPLACE MISSING P/V VALVE FLAME SCREEN ON #2S CENTER TANK PRIOR TO CONDUCTING CARGO OPERATIONS.
Condition: Unknown
Due 5 July 1995
Resolved 20 June 1995
Deck/Cargo
Issued 4 June 1994
Resolved
PLACE STUDS ON VAPOR CONTROL SYSTEM MANIFOLD CONNECTION AS REQUIRED BY 46CFR39.20-1(e).
Condition: Unknown
Due 4 June 1994
Resolved 4 June 1994
Electrical
Issued 4 June 1994
Resolved
RENEW ELECTRICAL CABLE TRAY/BRACKETS TO CABLE RUN IN WAY OF OVERHEAD, BOAT DK LVL ABOVE MACHINERY SPACE/TWEEN DECK FIXED CO2 ACTUATOR BOTTLES.
Condition: Unknown
Due 4 June 1994
Resolved 4 June 1994
Deck/Cargo
Issued 4 June 1994
Resolved
RENEW FLAMES SCREEN TO CARGO TKS C-6S, C-6P, AND C-7. VSL RESTRICTED TO CLOSE LOADING OF LISTED CARGO TKS UNTIL REQUIREMENT IS MET._x001C_ _x001C_ MATERIAL ON ORDER BY VSL.
Condition: Unknown
Due 4 June 1994
Resolved 4 June 1994
Electrical
Issued 4 June 1994
Resolved
PROVIDE GLOBE GUARDS FOR EXTERIOR LIGHTS IN WAY OF PORT/STBD MAST HOUSE._x001C_ ITEMS ON ORDER BY VSL.
Condition: Unknown
Due 4 June 1994
Resolved 4 June 1994
Deck/Cargo
Issued 4 June 1994
Resolved
PROVIDE HIGH/LOW PRESSURE VISUAL AND AUDIBLE ALARMS FOR VAPOR CONTROL SYSTEM IAW 46CFR39.20-13. _x001C_ NOTE: REQUIREMENT WAIVED UNTIL VSL'S NEXT DRYDOCK OR 01NOV95 WHICH EVER COMES FIRST IAW COMDT LTR 16703/46-39, DTD 10JUL92.
Condition: Unknown
Due 4 June 1994
Resolved 4 June 1994
Lifesaving
Issued 4 June 1994
Resolved
RENEW UPPER AND LOWER RUDDER HINGES TO BOTH PORT/STBD LIFEBOATS AS ORIGINAL.
Condition: Unknown
Due 4 June 1994
Resolved 4 June 1994
Fire Fighting
Issued 4 June 1994
Resolved
PROVIDE SERVICING REPORT ON RENEWAL/REPLACEMENT OF FIXED CO2 SYSTEM ACTUATOR BOTTLES (2) FOR TWEEN DECK AND MACHINERY SPACE SYSTEM.
Condition: Unknown
Due 4 June 1994
Resolved 7 June 1994
Fire Fighting
Issued 4 June 1994
Resolved
PROVIDE SERVICING REPORT TO DRY POWDER SYSTEM IN MAST ROOM PORTSIDE TO COGNIZANT OCMI NOT LATER THAN 11 JUN94 OR NEXT U.S. PORT.
Condition: Unknown
Due 4 June 1994
Resolved 4 June 1994
Documentation
Issued 3 June 1993
Resolved
SUBMIT VESSEL RESPONSE PLAN TO U. S. COAST GUARD AND PLACE REQUIRED SECTIONS ON BOARD PRIOR TO 18AUG93.
Condition: Unknown
Due 3 June 1993
Resolved 3 June 1993
Engineering
Issued 3 June 1993
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR 15 PPM ALARM TO COGNIZANT OCMI AT NEXT U. S. PORT.
Condition: Unknown
Due 3 June 1993
Resolved 3 June 1993
Documentation
Issued 14 June 1991
Resolved
PROVIDE UPDATED SAFF MANNING CERTIFICATE.
Condition: Unknown
Due 14 June 1991
Resolved 14 June 1991
Deck/Cargo
Issued 14 June 1991
Resolved
PROVE PROPER OPERATION OF HIGH LEVEL ALARMS PRIOR TO LOADING CARGOES REQUIRING THESE ALARMS.
Condition: Unknown
Due 14 June 1991
Resolved 14 June 1991
Deck/Cargo
Issued 14 June 1991
Resolved
PROVIDE CAPS FOR EYEWASH AND HANDLE FOR SHOWER AT STARBOARD MANIFOLD.
Condition: Unknown
Due 14 June 1991
Resolved 14 June 1991
Electrical
Issued 28 September 1990
Resolved
MAKE REPAIRS TO THE EXPLOSION PROFF LIGHT FIXTURE IN THE DRY CHEMICAL UNIT ROOM ON CARGO DECK PRIOR TO NEXT U.S. PORT CALL.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Deck/Cargo
Issued 28 September 1990
Resolved
PROVE PROPER OPERATION OF THE CARGO HIGH LEVEL AND TANK OVERFLOW ALARM AND INDICATOR SYSTEM IN ACCORDANCE WITH 46 CFR 153.408 AND 153.409 PRIOR TO THE NEXT US PORT CALL.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Deck/Cargo
Issued 28 September 1990
Resolved
INSTALL A PV VALVE ON THE TOLUENE STORAGE TANK PRIOR TO THE NEXT US PORT CALL.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Deck/Cargo
Issued 28 September 1990
Resolved
REPAIR OIL DISCHARGE MONITOR CONTROL SYSTEM AND ALARMS AND PROVE PROPER OPERATION PRIOR TO THE NEXT US PORT CALL.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Documentation
Issued 28 September 1990
Resolved
PROVIDE AN OIL RECORD BOOK PART TWO PRIOR TO THE NEXT US PORT CALL.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Documentation
Issued 8 July 1989
Resolved
HAVE INTERMIDIATE SURVEY DONE PRIOR TO TRANSFER OF CARGO.
Condition: Unknown
Due 8 July 1989
Resolved 8 July 1989
Unknown
Issued 30 August 1988
Resolved
CLOSED GAUGING DEVICES FOR 2 PORT, 4 PORT, 5 CENTER AND 8 CENTER ARE NOT OPERATIONAL. CARGOES REQUIRING CLOSED OR RESTRICTED GAUGING MAY NOT BE LOADED IN THESE TANKS IN U.S. WATERS UNTIL REPAIRS ARE MADE.
Condition: Unknown
Due 30 August 1988
Resolved 30 August 1988
Deck/Cargo
Issued 6 July 1988
Resolved
VESSEL IS PROHIBITED FROM CARRYING CARGOES REFERENCING IMO CHEMICAL CODE SECTIONS 4.12.1, 4.12.2, OR 4.12.3 IN THE ZINC LINED WING TANKS.
Condition: Unknown
Due 6 July 1988
Resolved 6 July 1988
Deck/Cargo
Issued 6 July 1988
Resolved
EFFECT PERMANENT REPAIRS TO THE OVERFILL ALARM SYSTEM.
Condition: Unknown
Due 6 July 1988
Resolved 6 July 1988
Unknown
Issued 6 July 1988
Resolved
GAS FREE AND PROVIDE A MARINE CHEMIST CERTIFICATE FOR THE SHELTER DECK AND MAKE AVAILABLE FOR COAST GUARD INSPECTION.
Condition: Unknown
Due 6 July 1988
Resolved 6 July 1988
Fire Fighting
Issued 6 July 1988
Resolved
FREE UP THREE VENT DAMPERS LOCATED ON FORECASTLE.
Condition: Unknown
Due 6 July 1988
Resolved 6 July 1988
Deck/Cargo
Issued 6 July 1988
Resolved
OPEN AND CLEAN ALL CARGO TANK P/V VALVES.
Condition: Unknown
Due 6 July 1988
Resolved 6 July 1988
Deck/Cargo
Issued 6 July 1988
Resolved
RENEW ALL CARGO TANK P/V VALVE FLAME SCREENS.
Condition: Unknown
Due 6 July 1988
Resolved 6 July 1988
Engineering
Issued 6 July 1988
Resolved
RENEW BUNKER TANK VENT FLAME SCREENS AFT.
Condition: Unknown
Due 6 July 1988
Resolved 6 July 1988
Fire Fighting
Issued 6 July 1988
Resolved
FREE UP THE VENT DAMPER TO DOUBLE BOTTOM #2.
Condition: Unknown
Due 6 July 1988
Resolved 6 July 1988
Deck/Cargo
Issued 6 July 1988
Resolved
EFFECT PERMANENT REPAIRS TO THE FOLLOWING CARGO TANK CLOSED GUAGING DEVICES#1P, #1S, #3C, #4C, #3P, #5C, #3S, #6CS, #7C, #8C, & #4S.
Condition: Unknown
Due 6 July 1988
Resolved 6 July 1988
Navigation
Issued 6 July 1988
Resolved
POST A LINE DIAGRAM AND EMERGENCY STEERING INSTRUCTIONS IN THE STEERING FLAT.
Condition: Unknown
Due 6 July 1988
Resolved 6 July 1988
Navigation
Issued 10 March 1988
Resolved
33CFR164.33(A)(2)(I) COAST PILOT VOLUME 5 WAS UNCORRECTED.
Condition: Unknown
Due 22 March 1988
Resolved 10 March 1988
Documentation
Issued 10 March 1988
Resolved
33CFR155.720 INCOMPLETE OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 10 March 1988
Resolved 10 March 1988
Navigation
Issued 1 July 1987
Resolved
OPERATING INSTRUCTIONS WITH A BLOCK DIAGRAM SHOWING CHANGE OVER PROCEDURES FOR REMOTE STEERING GEAR NOT DISPLAYED ON THE VESSEL'S BRIDGE OR IN THE STEERING COMPARTMENT.
Condition: Unknown
Due 1 July 1987
Resolved 1 July 1987
Navigation
Issued 1 July 1987
Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITHOUT CHART 12327 0N BOARD.
Condition: Unknown
Due 1 July 1987
Resolved 1 July 1987
Navigation
Issued 1 July 1987
Resolved
THE WHEELHOUSE MANEUVERING INFORMATION FACT SHEET DID NOT CONTAIN THE RE- QUIRED WARNING STATEMENT.
Condition: Unknown
Due 1 July 1987
Resolved 1 July 1987
Deck/Cargo
Issued 1 July 1987
Resolved
VESSEL DID NOT HAVE TOXIC VAPOR DETECTORS, AS REQUIRED FOR A CARGO OF PERCHLOROETHYLENE.
Condition: Unknown
Due 1 July 1987
Resolved 1 July 1987
Deck/Cargo
Issued 1 July 1987
Resolved
FAULTY VALVE FOR AIR PURGE OF CARGO PUMP CAUSED STYRENE TO BE BLOWN ON DECK THROUGH BLEEDER.
Condition: Unknown
Due 1 July 1987
Resolved 1 July 1987
Navigation
Issued 26 March 1985
Resolved
NO TURNING CIRCLE DIAGRAM
Condition: Unknown
Due 26 March 1985
Resolved 26 March 1985