Records from 1984 to 1995. Most recent: inspection, 16 March 1995.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 22
16 March 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1382920
2 August 1991
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 937998
29 July 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 345002
2 April 1991
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1239277
28 March 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 900817
27 March 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 342708
19 November 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 494815
19 November 1990
Certificate of Compliance
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1234636
20 November 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 531282
3 May 1989
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 506524
13 December 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 327337
17 October 1988
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 888458
3 May 1988
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 323414
3 May 1988
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1041757
29 April 1988
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 502070
24 October 1986
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 312225
24 October 1986
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1018707
17 December 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 537382
16 December 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 535215
16 December 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 994013
11 September 1984
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 485131
6 September 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282478
Deck/Cargo
Issued 19 November 1990
Resolved
PROVIDE CARGO MANIFOLD SPRAY SHIELDS IN ACCORDANCE WITH 46 CFR 153.554. TOBE COMPLETED PRIOR TO NEXT US VOYAGE.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Lifesaving
Issued 19 November 1990
Resolved
PROVIDE SIGN ON MAIN DECK INDICATING LOCATION OF PUMPROOM EMERGENCY WASH- DOWN SHOWER. TO BE COMPLETED PRIOR TO NEXT US VOYAGE.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Construction/Loadline
Issued 19 November 1990
Resolved
PROVE SATISFACTORY OPERATION OF "CONTROL" BALLAST MONITOR. TO BE COMPLETEDPRIOR TO NEXT US VOYAGE.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Fire Fighting
Issued 19 November 1990
Resolved
PAINT EMG. FIRE PUMP CONTROL VALVES MAIN DECK FWD RED. TO BE COMPLETED PRIOR TO NEXT US VOYAGE.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Deck/Cargo
Issued 19 November 1990
Resolved
ENSURE ALL CARGO SAMPLES IN "SAMPLE ROOM" ARE PROPERLY SEALED. TO BE COMPLETED PRIOR TO NEXT US VOYAGE.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Fire Fighting
Issued 19 November 1990
Resolved
REMOVE BLASTING SAND POSITIONED IN WAY OF #3 DRY POWDER FIRE STATION. TO BE COMPLETED PRIOR TO NEXT US VOYAGE.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Fire Fighting
Issued 19 November 1990
Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS. TO BE COMPLETED PRIOR TO NEXT US VOYAGE.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Deck/Cargo
Issued 19 November 1990
Resolved
RELOCATE CARGO MANIFOLDS ABOVE EXISTING CONTAINMENT PANS OR PROVIDE NEW CONTAINMENT BELOW MANIFOLD. TO BE COMPLETED PRIOR NEXT US VOYAGE.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Fire Fighting
Issued 19 November 1990
Resolved
MOVE FIRE HOSE BOX TO STERN CONTROL STATION STBD SIDE MAIN DECK. TO BE COMPLETED PRIOR TO NEXT US VOYAGE.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Deck/Cargo
Issued 19 November 1990
Resolved
PLACE ALL PAINT INTO FWD PAINT LOCKER. TO BE COMPLETED PRIOR TO NEXT US VOYAGE.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Construction/Loadline
Issued 19 November 1990
Resolved
SECURE FOREPEAK ACCESS HATCH (BOLTED COVER). TO BE COMPLETED PRIOR TO NEXTUS VOYAGE.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Construction/Loadline
Issued 19 November 1990
Resolved
SECURE BOLTED ACCESS HATCH TO UPPER TUNNEL LOCATED IN AFT PUMP ROOM. TO BECOMPLETED PRIOR TO NEXT US VOYAGE.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Documentation
Issued 19 November 1990
Resolved
PROVIDE UP-TO-DATE VERSION OF 46 CFR PARTS 140-155. TO BE COMPLETED PRIOR TO NEXT US VOYAGE.
Condition: Unknown
Due 19 November 1990
Resolved 19 November 1990
Accommodation/Occupational Safety
Issued 17 October 1988
Resolved
MARINE SANITATION DEVICE INOPERABLE, PRIOR TO REENTRY U.S. WATERS MAKE MSD OPERABLE OR INSTALL NEW APPROVE DEVICE AND PROVE OPERATION. WHILE IN U.S. WATERS ONE (1) PORTABLE TOILET FOR EACH SIX (6) CREW MEMBERS IS TO BE PROVIDED ON BOARD THE VESSEL.
Condition: Unknown
Due 17 October 1988
Resolved 17 October 1988