← All vessels
PETRO AZTECA
PETRO AZTECA is a 1977 tank ship. The Coast Guard has recorded 74 inspections since 1984, most recently in October 2000, along with 66 deficiencies and 2 operational controls.
Records from 1984 to 2000. Most recent: inspection, 21 October 2000.
- Built
- 1977
- Last inspected
- 21 October 2000
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 66 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7633117 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FCM7
51791
Flag
LIBERIA
—
Maury page id
psix-51791
Inspections, by type
…with no type recorded57
Years with a record
15 calendar years (1984–2000)
The 74 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it1881 - Regulatory (Subpart C or D), Net Ton
6159 - Dead Weight, Ton
10599 - Displacement, Ton
6271 - Regulatory (Subpart C or D), Gross Ton
6159 - Dead Weight, Ton
10599 - Displacement, Ton
6271 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 74
21 October 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 283253
7 June 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 278657
31 May 2000
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1050151
1 May 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 278528
19 April 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 277089
19 April 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 819329
17 April 2000
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1048783
28 October 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 434315
30 August 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 486821
11 August 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 690038
8 August 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 431524
18 July 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 149382
11 June 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 431730
9 April 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 429067
9 April 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1445448
17 December 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 506082
9 July 1998
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 418115
17 May 1998
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1421515
15 April 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 414412
15 April 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1128027
27 June 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 405054
30 March 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 389182
30 March 1996
Letter of Compliance (Initial/Renewal) · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1416272
27 August 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 19443
26 May 1993
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 671246
27 April 1993
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 459912
27 April 1993
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 501760
11 February 1993
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 356322
13 January 1993
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 825718
28 August 1992
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1267797
13 July 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 671245
28 June 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 93981
20 May 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 473506
29 January 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 683050
22 January 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 158444
18 December 1991
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 960820
15 September 1991
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 454113
3 June 1991
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 914646
23 December 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 342627
2 November 1990
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 913793
12 September 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 900802
20 August 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 491548
15 May 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 474997
21 March 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 336450
14 March 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 921745
29 December 1989
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 527221
29 December 1989
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1233086
22 December 1989
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 913081
7 September 1989
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1206047
22 June 1989
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 474492
21 June 1989
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1044042
19 June 1989
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1038853
26 May 1989
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1346677
16 February 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 531206
21 December 1988
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1034208
2 November 1988
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 326477
2 November 1988
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 890395
16 August 1988
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1345720
7 June 1988
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 473913
9 February 1988
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 457472
28 January 1988
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1016831
28 October 1987
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1021166
27 October 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 455763
27 October 1987
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1017380
27 May 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 524393
27 May 1987
MARPOL Annex II Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1334898
29 October 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 312353
29 October 1986
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1323038
28 July 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 502656
19 November 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 305449
6 November 1985
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1303649
25 July 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 483780
4 January 1985
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 300781
29 October 1984
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 975800
Deficiency record · 66
Documentation
Issued 19 April 2000
Resolved
ALL CREW TO PROVIDE CURRENT MEDICAL CERTIFICALTES.
Documentation
Issued 19 April 2000
Resolved
AUDITOR TO COME ON BOARD AND VERIFY IMPLEMENTATION OF SAFETY MANAGEMENT SYSTEM DUE TO: A. LACK OF INTERNAL AUDITS, B. MAINTENANCE PROBLEMS WITH LIFE BOAT LIFTHOOK AND FIRE SUITS._x001C_ TO BE CORRECTED PRIOR TO DEPARTURE.
Fire Fighting
Issued 19 April 2000
Resolved
REPLACE ALL AFFECTIVE FIRE SUITS. NEED TOTAL OF FOUR._x001C_ TO BE CORRECTED PRIOR TO DEPARTURE.
Electrical
Issued 19 April 2000
Resolved
BLANK OFF ALL UNUSED OPENINGS AT MAIN ELECTRICAL PANEL.
Engineering
Issued 19 April 2000
Resolved
REPLACE NON-WORKING SOLENOID VALVE IN THE IOL WATER SEPARATOR. _x001C_ CLASS SURVEYOR TO PROVIDE STATEMENT OF FACT INDICATING COMPLETION.
Engineering
Issued 19 April 2000
Resolved
CLASS SURVEYOR TO INSPECT OIL WATER SEPARATOR AND ASSESS WHAT COULD POTENTIALLY BE USED AS "BY PASS". _x001C_ CLASS SURVEYOR TO PROVIDE STATEMENT OF FACT INDICATION COMPLETION.
Fire Fighting
Issued 19 April 2000
Resolved
DEVELOP "REALISTIC" INSTRUCTIONS FOR MANUAL OPERATION OF DRY CHEM SYSTEM.
Lifesaving
Issued 19 April 2000
Resolved
CLASS SURVEYOR TO ASSESS CONDITION OF LIFEBOAT LIFTHOOKS AND PROVIDE STATEMENT._x001C_ CLASS SURVEYOR TO PROVIDE STATEMENT OF FACT INDICATING COMPLETION.
Engineering
Issued 8 August 1999
Resolved
EXAMINED OWS. FOUND PIPING THAT ALLOWED DIRECT OVERBOARD DISCHARGE. PIPING WAS RMVD O/S AND FLANGES TACK WELDED SHUT. UNABLE TO OBTAIN EVIDENCE FM ORBOR ELSEWHERE TO PROCESS MV CASE. STERN DECK ALSO SHOWED EVIDENCE OF PRIOR SPILL.
Fire Fighting
Issued 11 June 1999
Resolved
ADJUST THE PURGING FUNCTION OF THE GAS DETECTION UNIT TO THE SATISFACTON OFCLASS. CLASS TO SUBMITT REPORT OF PROPER OPERATION.
Deck/Cargo
Issued 11 June 1999
Resolved
CLASS SOCIETY (DNV) TO ADDRESS IN WRITING THE FREQUENCY STANDARDS FOR PRESSURE TESTING OF CARGO / VAPOR LINES.
Navigation
Issued 9 April 1999
Resolved
Repair hydraulic tank low level alarm for the steering unit (low oil level alarm).
Deck/Cargo
Issued 9 April 1999
Resolved
Provide evidence that cargo transfer and vapor transfer lines have be pressure tested in accordance with 33 CFR 156.170 within the last year.
Fire Fighting
Issued 9 April 1999
Resolved
Remove all holdback devices for all fire screen doors located in the main staircase.
Deck/Cargo
Issued 9 April 1999
Resolved
Provide statement from class sociey addressing proper operation of high andlow pressure alarms for all cargo tanks. Crew had lost testing equipment._x001C__x001C_ _x001C_
Lifesaving
Issued 9 April 1999
Resolved
Repair/replace port and starboard side grab rails on the starboard side lifeboat.
Deck/Cargo
Issued 9 April 1999
Resolved
Provide U-bolts to hold carog lines in place (numerous areas were noted where the U-bolts were missing. Make sure the U-bolts are not tighened down to prevent contraction of the piping when cargo runs through the line.
Lifesaving
Issued 9 April 1999
Resolved
Provide self-closing device for escape route door located in the engine room.
Deck/Cargo
Issued 9 April 1999
Resolved
Provide bonding straps of cargo line flanges where missing (cargo lines topsided of cargo tanks #2,3,4,5). 46 CFR 154.514
Electrical
Issued 9 April 1999
Resolved
Renew connectors to electrical boxes in way of cargo tank domes #3,4,5._x001C_ Stand pipe connections wasted, electrical boxes no longer explosion proof._x001C__x001C_ _x001C_
Deck/Cargo
Issued 9 April 1999
Resolved
Properly labe cargo discharge/vapor recovery lines at all manifold stations._x001C_ _x001C_ _x001C_
Deck/Cargo
Issued 9 April 1999
Resolved
Renew flamescreens on numerous fuel oil vents. Screens painted over, corroded or dirty.
Deck/Cargo
Issued 9 April 1999
Resolved
Provide suitable wood spacers for cargo piping system in order to avoid excessive movement (areas located at manifolds and overhead piping). Wood spacers split, missing or rotted away.
Electrical
Issued 9 April 1999
Resolved
Renew electrical stuffing tubes for the high level alarms (98%), located atcargo tank dome #5._x001C_ _x001C_ _x001C_
Deck/Cargo
Issued 9 April 1999
Resolved
Repair or replace the quick acting hydraulic valve to the vapor line located at the forward starboard cargo manifold. Valve frozen shut._x001C_ _x001C_ _x001C_
Fire Fighting
Issued 9 April 1999
Resolved
Renew nozzle connectin for all dry power hoses located next to cargo tanks #2 and 4, port side.
Lifesaving
Issued 9 April 1999
Resolved
Remove jubille patches placed as temporary repairs on three fuel oil containment stations vent lines and provide permanent repairs._x001C_ _x001C_ _x001C_
Fire Fighting
Issued 9 April 1999
Resolved
Renew gloves for 01 firesuit. Gloves are in badly worn._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 9 April 1999
Resolved
Renew/replace antenas for portable VHF-FM radios used on deck. 04 radios noted w/o rubber protection covers.
Electrical
Issued 15 April 1998
Resolved
REPAIR LIGHT AT ENTRANCE TO CO2 ROOM, TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD.
Electrical
Issued 15 April 1998
Resolved
PROPERLY DISPOSE OF OLD BATTERIES IN EMERGENCY BATTERY ROOM, TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD.
Lifesaving
Issued 15 April 1998
Resolved
REMOVE FLAMMABLE MATERIAL FROM CO2 ROOM TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD.
Engineering
Issued 15 April 1998
Resolved
INSTALL CONTAINMENT AROUND OIL VENTS ON STBD SIDE OF STACK.
Electrical
Issued 15 April 1998
Resolved
REPLACE BATTERIES THAT ARE DAMAGED IN EMERGENCY BATTERY ROOM, TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD.
Construction/Loadline
Issued 15 April 1998
Resolved
MAKE GAS TIGHT ELECTRICAL CABLE PENETRATION IN ELECTRIC MOTOR ROOM OVERHEAD, TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD.
Engineering
Issued 15 April 1998
Resolved
SECURE LEAK FROM LUBE OIL SEPARATOR PIPING CONNECTION TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD.
Deck/Cargo
Issued 15 April 1998
Resolved
MAKE REPAIR TO INERT GAS GENERATOR DRY AIR SYSTEM AND DEMONSTRATION TO CLASS THE OPERATION AND ALL ALARMS AND SHUTDOWNS TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD.
Deck/Cargo
Issued 15 April 1998
Resolved
REPAIR FIX OXYGEN ANALYZER AND DEMONSTRATE CALIBRATION ON INERT GAS SYSTEM TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD.
Deck/Cargo
Issued 15 April 1998
Resolved
PROVIDE ZERO GAS WITH CERTIFICATE OF ANALYSIS FOR INERT GAS SYSTEM TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD.
Deck/Cargo
Issued 15 April 1998
Resolved
TEST CARGO PIPING RELIEF VALVES TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD.
Accommodation/Occupational Safety
Issued 15 April 1998
Resolved
REMOVE HOLDBACK FROM COMPRESSOR ELECTRIC MOTOR ROOM DOOR TO SATISFACTION OFCLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD..
Lifesaving
Issued 15 April 1998
Resolved
TEST/SERVICE EPIRB HYDROSTATIC RELEASE UNIT TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD.
Fire Fighting
Issued 15 April 1998
Resolved
LABEL VISUAL ALARMS ON DECK FOR GAS DETECTION CARGO HIGH LEVEL TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD.
Engineering
Issued 15 April 1998
Resolved
MAKE PROPER AND SEAL CONNECTION FOR FUEL, DIESEL AND LUBE OIL SEPARATION ELECTRICAL CONNECTION TO MOTORS TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD.
Fire Fighting
Issued 15 April 1998
Resolved
PROVIDE EMERGENCY ESCAPE SET IN PROPERLY MARK CONTAINER IN ENGINE ROOM TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD.
Documentation
Issued 15 April 1998
Resolved
REMOVE ALL PRODUCTS FROM MARPOL ANNEX II CARGO LIST IN PROCEDURE AND ARRANGEMENT MANUAL THAT ARE NOT AUTHORIZED BY CERTIFICATE OF FITNESS TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD.
Deck/Cargo
Issued 15 April 1998
Resolved
PROVIDE CARGO VOID SPACES ARE INERT OR DRYED BELOW DEW POINT TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD.
Deck/Cargo
Issued 15 April 1998
Resolved
DEMONSTRATE PROPER OPERATION OF GAS DETECTION SYSTEM METER AND ALARM BY INJECTING GAS INTO SAMPLE POINTS IN MOTOR ROOM TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD.
Deck/Cargo
Issued 15 April 1998
Resolved
RENEW BROKEN PIPE HANGER ON STBD OUTBOARD CARGO LINE BY #5 CARGO TANK TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD.
Accommodation/Occupational Safety
Issued 13 January 1993
Resolved
Provide and display placard with the USCG approval number for the Marine Sanitation Device prior to the next U.S. port.
Fire Fighting
Issued 2 November 1990
Resolved
PRIOR TO CONDUCTING CARGO OPERATIONS OR DEPARTING THE PORT OF HOUSTON, HAVEALL PORTABLE FIRE EXTINGUISHERS AND DRY CHEMICALS FIXED. FIRE FIGHTING SYSTEM PROFESSIONALLY SERVICED.
Documentation
Issued 2 November 1990
Resolved
PROVIDE WRITTEN OIL TRANSFER PROCEDURES FOR REVIEW AND POST PROCEDURES IN ACCORDANCE WITH 33CFR 155.740. PRIOR TO DEPARTING THE PORT OF HOUSTON.
Unknown
Issued 2 November 1990
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving
Issued 2 November 1990
Resolved
INSTALL WEAK LINKS TO SEA PAINTERS FOR ALL LIFERAFTS AND SECURE PROPERLY TOVESSEL PROIR TO DEPARTING THE PORT OF HOUSTON.
Navigation
Issued 21 March 1990
Resolved
VESSEL MUST HAVE EMERGENCY STEERING MANNED DURING TRANSIT OF PHIMS ZONE UNTIL SECONDARY PUMP IS INSTALLED.
Navigation
Issued 14 March 1990
Resolved
DEMONSTRATE OPS.OF AUX.STEERING GEAR HAND PUMP UNIT IN THE PRESENCE OF A USCG MARINE INSPECTOR,OR A CLASSIFICATION SOCIETY SURVEYOR WHILE VESSEL IS NAVIGATING PRIOR TO NEXT U.S. PORT.
Deck/Cargo
Issued 21 June 1989
Resolved
RENEW AS ORIGINAL SMALL VALVE ON VAPOR DISCHARGE LINE FOR CARGO TANKS 3-5 LOCATED JUST FORWARD OF THE MAIN HOUSE AND BEING THE FIRST VAPOR DISCHARGE LINE TO PORT OF CENTERLINE AT ABOVE CARGO DECK FORE AND AFT WALKWAY LEVEL.
Electrical
Issued 21 June 1989
Resolved
MAKE PERMANENT REPAIRS TO ELECTRICAL CABLE SHIELDING FOR AND MAKE INSTRINSICALLY SAFE CARGO PUMP CONTROL BOXES 2,3,4, & 5 ON DECK.
Electrical
Issued 21 June 1989
Resolved
MAKE PERMANENT REPAIRS TO ELECTRICAL CABLE SHIELDING FOR AND MAKE INTRINSICALLY SAFE REMOTE INERT GAS FAN CONTROL BOX BETWEEN CARGO TANKS 2 & 3.
Deck/Cargo
Issued 2 November 1988
Resolved
PROVE PROPER OPERATION OF IGS.
Deck/Cargo
Issued 2 November 1988
Resolved
MARK CARGO PIPING APPROPRIATELY WITH "LIQUID OR VAPOR".
Unknown
Issued 27 October 1987
Resolved
SUBMIT NOXIOUS LIQUID SUBSTANCE CERTIFICATE FOR CARRIAGE OF NLS CARGOES TO COMDT (G-MTH-1) AND OBTAIN A NEW C&R LIST PRIOR TO CARRYING ISOPRENE.
Unknown
Issued 27 October 1987
Resolved
RENEW BUNKER TANK VENT FLAME SCREENS LOCATED AFT.
Unknown
Issued 27 October 1987
Resolved
EFFECT PERMANENT REPAIRS TO THE EXPLOSION PROOF JUNCTION BOX LOCATED ON CARGO PUMP MOTOR NUMBER 2 PRIOR TO OPERATING MOTOR #2 IN U.S. WATERS.
Deck/Cargo
Issued 27 October 1987
Resolved
EFFECT PERMANENT REPAIRS TO THE VAPOR LINE PORT SIDE AT MANIFOLD PRIOR TO ENTERING U.S. WATERS AFTER THE COMPLIANCE DATE.
Deck/Cargo
Issued 29 October 1986
Resolved
EFFECT REPAIRS AND PROVE OPERATION OF GAS DETECTION SYSTEM.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.