Records from 1985 to 1993. Most recent: inspection, 4 October 1993.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 28
4 October 1993
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 534568
4 October 1993
Certificate of Compliance
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1403684
10 May 1993
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1148237
7 May 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 460850
6 May 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 825835
18 June 1991
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1219953
11 December 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 922725
15 November 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 929363
11 November 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 503614
13 September 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 510104
13 September 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1039186
3 September 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1195125
9 July 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1035902
29 June 1989
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1213619
1 March 1989
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 476802
27 September 1988
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 325843
27 September 1988
Certificate of Compliance
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1043673
14 April 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 475608
27 November 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1339084
14 August 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 318074
14 August 1987
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1339403
16 April 1987
MARPOL Annex II Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1022657
8 April 1987
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 443315
30 July 1986
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 310499
16 January 1986
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 491752
28 August 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 303934
7 August 1985
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1294668
6 July 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 302974
Electrical
Issued 4 October 1993
Resolved
Demonstrate satisfactory operation of emergency generator auto-start to satisfaction of classification society representative. Vessel may transit under tug escort from Point Wells to nearest safe anchorage until repairs are made. See MINS this case for details.
Condition: Unknown
Due 5 October 1993
Resolved 6 October 1993
Deck/Cargo
Issued 29 June 1989
Resolved
PROVIDE ONE ADDITIONAL OPERABLE OXYGEN INDICATOR PRIOR TO NEXT U.S. PORT ENTRY.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Deck/Cargo
Issued 29 June 1989
Resolved
MAKE PERMANENT REPAIRS IN LIEU OF SOFT PATCH TO VENT PIPING TO NO. 6 STBD CARGO TANK PRIOR TO NEXT U.S. PORT ENTRY.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Deck/Cargo
Issued 29 June 1989
Resolved
REPAIR CLOSED GAUGING SYSTEM. NO GARGOES REQUIRED BY 46 CFR SUBCHAPTER "O"TO HAVE CLOSED OR RESTRICTED GAUGING MAY BE LOADED.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Deck/Cargo
Issued 29 June 1989
Resolved
PROVIDE TWO OPERABLE COMBUSTIBLE GAS INDICATORS PRIOR TO NEXT U.S. PORT ENTRY.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Documentation
Issued 29 June 1989
Resolved
PROVIDE AN APPROVED (CLASSIFICATION SOCIETY) LOADING MANUAL IN ACCORDANCE WITH IMO CERTIFICATE OF FITNESS PRIOR TO NUXT U.S. PORT ENTRY.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Deck/Cargo
Issued 27 September 1988
Resolved
MAKE O2 DETECTORS OPERABLE PRIOR TO DEPARTURE FROM HOUSTON, TX.
Condition: Unknown
Due 27 September 1988
Resolved 27 September 1988
Fire Fighting
Issued 14 August 1987
Resolved
PROVIDE SAFETY LINE FOR ALL EMERGENCY OUTFITS.
Condition: Unknown
Due 14 August 1987
Resolved 14 August 1987
Fire Fighting
Issued 14 August 1987
Resolved
PROVIDE 3 CELL LIGHT FOR EMERGENCY GEAR LOCKER.
Condition: Unknown
Due 14 August 1987
Resolved 14 August 1987
Deck/Cargo
Issued 14 August 1987
Resolved
REPAIR O2 INDICATORS.
Condition: Unknown
Due 14 August 1987
Resolved 14 August 1987
Documentation
Issued 16 April 1987
Resolved
SUBMIT NEW CERTIFICATE OF FITNESS REFERENCING MEPC 20(22) TO COMMANDANT (G-MTH-1) FOR APPROVAL AND OBTAIN NEW SUBCHAPTER "O" ENDORSEMENT.
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987
Unknown
Issued 7 August 1985
Resolved
WHEN LOADING CARGOES REQUIRING THE USE OF HIGH LEVEL ALARMS ENSURE THAT PORTABLE HIGH LEVEL ALARMS ARE IN PLACE IN THE TANKS BEING LOADED. VESSEL CAN ONLY LOAD 7 CENTER LINE TANKS WITH CARGOES THAT ARE REQUIRED TO BE LOADED IN CENTER LINE TANKS UNTIL 3 ADDITIONAL OVER FILL ALARMS ARE ADDED.
Condition: Unknown
Due 7 August 1985
Resolved 7 August 1985
Navigation
Issued 6 July 1985
Resolved
VESSEL DID NOT HAVE CHARTS 11341/11332, 11342 ONBOARD AS REQUIRED BY 33 CFR 164.33(A)(1)(II). VESSEL ALSO HAD OUTDATED CHART 11340 W/O CORRECTIONS
Condition: Unknown
Due 7 August 1985
Resolved 6 July 1985
Documentation
Issued 6 July 1985
Resolved
VESSEL DID NOT HAVE POLLUTION PLACARD ONBOARD AS REQUIRED BY 33 CFR 155.450.
Condition: Unknown
Due 7 August 1985
Resolved 6 July 1985
Fire Fighting
Issued 6 July 1985
Resolved
VESSEL DID NOT HAVE AN EMERGENCY FIRE CONTROL PLAN ONBOARD LOCATED IN A WEATHER TIGHT CONTAINER OUTSIDE DECKHOUSE AVAILABLE FOR SHORESIDE FIRE- FIGHTING PERSONNEL AS REQUIRED BY SOLAS 74, CHAPTER II-2, REG 20-2, AMENDED1981.
Condition: Unknown
Due 7 August 1985
Resolved 6 July 1985
Navigation
Issued 6 July 1985
Resolved
VESSEL DID NOT HAVE A DIAGRAM AND OPERATING INSTRUCTIONS FOR CHANGEOVER TO REMOTE STEERING GEAR POWER AND CONTROL SYSTEMS POSTED ON BRIDGE AS REQUIRED BY 33 CFR 164.35(K).
Condition: Unknown
Due 7 August 1985
Resolved 6 July 1985