Records from 1986 to 1989. Most recent: inspection, 10 October 1989.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 14
10 October 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1238683
4 October 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1195478
4 October 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1200274
26 August 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1351049
27 July 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1342113
8 June 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1199086
10 May 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1348033
18 February 1988
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1334595
22 December 1987
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1005793
22 December 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1313637
8 June 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1028545
4 December 1986
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1000301
5 September 1986
Credit Drydock · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1003400
15 April 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1310920
Deck/Cargo
Issued 27 July 1988
Resolved
PROVE PROPER OPERATION OF SAAB GUAGING SYSTEM.
Condition: Unknown
Due 27 July 1988
Resolved 27 July 1988
Deck/Cargo
Issued 18 February 1988
Resolved
CONDUCT HYDROSTATIC TEST OF CARGO PIPING TO A PRESSURE OF 150 PSI (10 BAR)
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Electrical
Issued 18 February 1988
Resolved
PROVIDE 24 V EMBARKATION LIGHTNING FORWARD FOR INFLATABLE LIFERAFT STATION.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Deck/Cargo
Issued 18 February 1988
Resolved
PROVE PROPER OPERATION OF ENGINE ROOM ALARM PANEL FOR INERT GAS SYSTEM
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Deck/Cargo
Issued 18 February 1988
Resolved
PROVE PROPER OPERATION OF GAUGING SYSTEM AND HIGH LEVEL ALARMS (SAAB & VEGA)
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Electrical
Issued 18 February 1988
Resolved
PROVE PROPER OPERATION OF REVERSE POWER RELAYS ON 440 V SWITCHBOARD.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Fire Fighting
Issued 18 February 1988
Resolved
PROVIDE CALIBRATION TEST GAS FOR PORTABLE COMBUSTIBLE GAS METER AND PROVE PROPER OPERATION OF SAME.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Deck/Cargo
Issued 18 February 1988
Resolved
PROVIDE TO USCG A COMPLETE SET OF 35MM B/W PHOTOGRAPHS OF ALL CARGO TANKS. PROCEDURES FOR MARKING AND NUMBERING INTERNAL STRUCTURES SHALL BE THE SAME AS FOLLOWED ON VULCANUS II (SEPT 87)
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Engineering
Issued 8 June 1987
Resolved
PROVE PROPER OPERATION OF THE INCINERATION PLANT HIGH, MIDDLE AND LOW TEMPERATURE INDICATORS; BURNER CONTROL UNITS; BURNER IGNITION UNITS, AND OXYGEN, CARBON DIOXIDE AND CARBON MONORIDE ANALYZERS.
Condition: Unknown
Due 8 June 1987
Resolved 8 June 1987
Deck/Cargo
Issued 8 June 1987
Resolved
PROVIDE A MEANS FOR MEASURE. THE PRESSURE DIFFERENTIAL BETWEEN THE INCINERATOR ROOM AND ATMOSPHERE.
Condition: Unknown
Due 8 June 1987
Resolved 8 June 1987
Lifesaving
Issued 8 June 1987
Resolved
REPAIR STARBOARD LIFEBOAT FIBERGLASS HULL IN WAY OF SIDE BUMPERS.
Condition: Unknown
Due 8 June 1987
Resolved 8 June 1987
Deck/Cargo
Issued 5 September 1986
Resolved
PROVE PROPER OPERATION OF INERT GAS SYSTEM WITH PROPER CALIBRATED TEST AND SPAN GAS.
Condition: Unknown
Due 5 September 1986
Resolved 5 September 1986
Deck/Cargo
Issued 5 September 1986
Resolved
VERIFY SET PRESSURE FOR THE CARGO PRESSURE/VACUUM VALVES.
Condition: Unknown
Due 5 September 1986
Resolved 5 September 1986
Deck/Cargo
Issued 5 September 1986
Resolved
PROVIDE COLORMETRIC DETECTOR TUBES FOR THE PORTABLE DREGER DETECTOR KITS. TUBES ON BOARD VESSEL ARE OUTDATED.
Condition: Unknown
Due 5 September 1986
Resolved 5 September 1986
Lifesaving
Issued 5 September 1986
Resolved
PROVIDE 12 COMBINATION FLAME AND SMOKE SIGNALS OR 12 FLARES.
Condition: Unknown
Due 5 September 1986
Resolved 5 September 1986
Fire Fighting
Issued 5 September 1986
Resolved
PROVIDE 2 LARGE FIRE AXES FOR THE EMERGENCY OUTFITS AND 5 ADDITIONAL AXES TO BE PLACED THROUGHOUT THE SHIP. ALL FIRE AXES TO BE MARKED WITH THE NAMEOF THE VESSEL.
Condition: Unknown
Due 5 September 1986
Resolved 5 September 1986
Deck/Cargo
Issued 5 September 1986
Resolved
PROVIDE A CALIBRATION TEST GAS FOR PORTABLE COMBUSTIBLE GAS METER AND PROVE PROPER OPERATION OF THE SAME.
Condition: Unknown
Due 5 September 1986
Resolved 5 September 1986
Deck/Cargo
Issued 5 September 1986
Resolved
VERIFY THE SET PRESSURE POINTS FOR THE PRESSURE RELIEF VALVE 950MM #20 (LOADING) 2100 MM H20 VOYPES.
Condition: Unknown
Due 5 September 1986
Resolved 5 September 1986
Electrical
Issued 5 September 1986
Resolved
THE ELECTRICAL EQUIPMENT REQUIRED TO BE INSTALLED FOR THE SAFE OPERATION OFTHE INCINERATORS (TEMP INDICATORS [HIGH,MIDDLE & LOW] 02,CO2, CO ANALYZERS,INCINERATOR EMER. SHUTDOWN SWITCHES, BURNER CONTROL BOXES, AIR CONSUMPTION CONTROL UNITS,BURNER IGNITION UNITS & BURNER DUCT DAMPER CONTROLS & MOTOR
Condition: Unknown
Due 5 September 1986
Resolved 5 September 1986
Construction/Loadline
Issued 5 September 1986
Resolved
PROVE THE PROPER OPERATION OF ALL WATERTIGHT DOORS, HATCHES, CLOSING DEVICES, FUEL OIL VENTS AND OTHER DEVICES IN THE AFT SECTION (OLDER) OF THESUBJECT VESSEL TO ENSURE WATERTIGHT INTEGRITY.
Condition: Unknown
Due 5 September 1986
Resolved 5 September 1986
Construction/Loadline
Issued 5 September 1986
Resolved
PROVIDE FOR THE LOCAL AND REMOTE OPERATION OF THE WATERTIGHT DOOR LEADING TO THE SHAFT ALLEY.
Condition: Unknown
Due 5 September 1986
Resolved 5 September 1986
Construction/Loadline
Issued 5 September 1986
Resolved
PROVE PROPER OPERATION OF THE NEWLY INSTALLED SELF-CLOSING DOORS.
Condition: Unknown
Due 5 September 1986
Resolved 5 September 1986
Fire Fighting
Issued 5 September 1986
Resolved
PROVIDE A 20 SECOND DELAY, AND AN AUTOMATIC SHUTDOWN FOR THE VENTILATION SYSTEM OF SPACES PROTECTED BY THE FIXED CO2 SYSTEM.
Condition: Unknown
Due 5 September 1986
Resolved 5 September 1986
Fire Fighting
Issued 5 September 1986
Resolved
PROVIDE 2 PORTABLE FIRE EXTINGUISHERS OF THE B-II TYPE FOR THE ON DECK CARGO AREA.
Condition: Unknown
Due 5 September 1986
Resolved 5 September 1986
Lifesaving
Issued 5 September 1986
Resolved
CONDUCT LIQUID STATIC TEST OF ON DECK CARGO PIPING TO 225 PSI. TEST PRESSURE AND TEST DATE TO BE MARKED ON PIPES TESTED.
Condition: Unknown
Due 5 September 1986
Resolved 5 September 1986
Lifesaving
Issued 5 September 1986
Resolved
CONDUCT WEIGHT TEST OF STARBOARD LIFE BOAT.
Condition: Unknown
Due 5 September 1986
Resolved 5 September 1986
Navigation
Issued 5 September 1986
Resolved
PROVE PROPER OPERATION OF LOCAL STEERING STATION IN AFTER STEERING.
Condition: Unknown
Due 5 September 1986
Resolved 5 September 1986
Electrical
Issued 5 September 1986
Resolved
PROVE PROPER OPERATION OF REVERSE POWER RELAY FOR #1 S/S GENERATOR.
Condition: Unknown
Due 5 September 1986
Resolved 5 September 1986
Electrical
Issued 5 September 1986
Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL PRESSURE CUT OUTS, OVERSPEEDS AND RELEASE POWER RELAYS ON INCINERATOR 440V GENERATORS #1 AND #2.
Condition: Unknown
Due 5 September 1986
Resolved 5 September 1986
Electrical
Issued 5 September 1986
Resolved
PROVE PROPER OPERATION OF EMERGENCY SHUT-DOWN SWITCH FOR INCINERATOR GENERATORS (LOCATED IN ACCOMMODATION SPACES).
Condition: Unknown
Due 5 September 1986
Resolved 5 September 1986
Lifesaving
Issued 5 September 1986
Resolved
EQUIP ALL LIFE JACKETS WITH WATER LIGHTS, WHISTLES AND RETRO-REFLECTIVE TAPE ON BOTH SIDES.
Condition: Unknown
Due 5 September 1986
Resolved 5 September 1986