← All vessels
SANTANA III
SANTANA III is a 1974 tank ship. The Coast Guard has recorded 18 inspections since 1984, most recently in September 1998, along with 77 deficiencies — 26 with no resolution recorded — and 1 operational control.
Records from 1984 to 1998. Most recent: inspection, 16 September 1998.
- Built
- 1974
- Last inspected
- 16 September 1998
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 77 recorded · 26 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7326116 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HXO5
51809
Flag
NORWAY
—
Maury page id
psix-51809
Inspections, by type
…with no type recorded14
…past their stated due date26
Years with a record
8 calendar years (1984–1998)
The 18 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it10383 - Regulatory (Subpart C or D), Net Ton
31300 - Dead Weight, Ton
18309 - Regulatory (Subpart C or D), Gross Ton
31300 - Dead Weight, Ton
18309 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 18
16 September 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 420289
11 September 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 420397
11 September 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 798766
5 September 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 144144
20 November 1990
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 340367
20 November 1990
Certificate of Compliance
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 904339
5 September 1989
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 332409
5 September 1989
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1034959
18 May 1988
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 475591
8 October 1987
Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1012229
7 October 1987
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 318834
10 December 1986
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 436470
8 August 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 310634
8 August 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1024777
23 November 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 517854
15 June 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 302823
8 April 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 301835
18 May 1984
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 296392
Deficiency record · 77
Construction/Loadline › Hull › Bottom Plating
Issued 16 September 1998
Resolved
Renew weathertight and watertight door leading to galley from stern._x001C_ _x001C_ ICCL 66/II/18.
Fire Fighting › Automatic Sprinkler System › Connection to Fire Main
Issued 16 September 1998
Resolved
Repair holed firemain in way of acetylene room by ladderwell on stbd. side._x001C_ _x001C_ SOLAS 60 II/66.
Electrical › Electric Generation Source (emergency) › Circuit Breaker
Issued 16 September 1998
Resolved
Provide class documentation of installation of standard electrical arrangement for exciter on emergency generator._x001C_ _x001C_ SOLAS 60 II/27.
Construction/Loadline › Hull › Bottom Plating
Issued 16 September 1998
Resolved
Renew unserviceable watertight hatch cover above emergency generator. _x001C_ _x001C_ ICCL
Lifesaving › Buoyant Apparatus › Capacity
Issued 16 September 1998
Resolved
Renew wasted launching cradles on portside liferaft._x001C_ _x001C_ SOLAS 60 III/30.15(g).
Construction/Loadline › Hull › Bottom Plating
Issued 16 September 1998
Resolved
Renew leaking watertight hatch leading to ship's stores._x001C_ _x001C_ ICLL
Documentation › Certificates/Documents › Annex VI Statement of Voluntary Compliance
Issued 16 September 1998
Resolved
Provide missing Inland Navigation Rules book to bridge._x001C_ _x001C_ SOLAS 60 V/20
Electrical
Issued 16 September 1998
Resolved
Belts on emergency generator slacked and cracked as per SOLAS 60 I/11.
Documentation
Issued 11 September 1998
Resolved
Provide documentation that vessel is manned with 4 engine certified ratingsor that substitution of fitters / electricians is permitted by that the flag state. Complete prior to return to a U. S. port after sailing foreign. STCW 95 III/4
Accommodation/Occupational Safety
Issued 11 September 1998
Resolved
Secure the loose & uneven deck plates about the steering gear machinery prior to return to a U. S. port after sailing foreign. _x001C_ _x001C_ SOLAS 60 II/29
Engineering
Issued 11 September 1998
Resolved
Replace the numerous missing U bolts on the deck bunker line prior to return to a U. S. port after sailing foreign. _x001C_ _x001C_ SOLAS 60 I/11
Deck/Cargo
Issued 11 September 1998
Resolved
Clean the cargo residue (molasses) from the pump room bilges and secure leaks from pumps prior to carriage of regulated cargoes. _x001C_ _x001C_ SOLAS 60 I/11
Deck/Cargo
Issued 11 September 1998
Resolved
Repair the many hydraulic leaks about the deck machinery (mooring winches, anchor windlasses, automatic valves, control boxes, line fittings). Clean the oil to prevent entry into water. Complete prior to return to a U. S. port after sailing foreign. 33 CFR 151.10(b)
Electrical
Issued 11 September 1998
Resolved
Repair all electrical splices to standards for hazardous locations. 'Rats Nest' located on the centerline about the manifolds. Complete prior to carriage of regulated cargoes. _x001C_ SOLAS 60 II/27
Navigation
Issued 11 September 1998
Resolved
Repair the pulled control wire on the stbd steering hear control unit priorto return to a U. S. port after sailing foreign. _x001C_ _x001C_ SOLAS 60 II/29
Accommodation/Occupational Safety
Issued 11 September 1998
Resolved
Repair the broken drain line in the vicinity of the port steering gear control box prior to return to a U. S. port after sailing foreign. _x001C_ _x001C_ SOLAS 60 II/29
Navigation
Issued 11 September 1998
Resolved
Repair the bent arm on the steering gear control feed back unit (mounted onsteering gear) prior to return to a U. S. port after sailing foreign. _x001C_ SOLAS 60 II/29
Construction/Loadline
Issued 11 September 1998
Resolved
Complete welding on the inserts in the overhead of the steering gear space prior to return to a U. S. port after sailing foreign. _x001C_ _x001C_ SOLAS 60 I/1
Engineering
Issued 11 September 1998
Resolved
No operation of the stbd generator engine is permitted until the fuel_x001C_ sprays and exhaust leaks are repaired #3 & 5 cylinders. _x001C_ _x001C_ SOLAS 60 I/11
Construction/Loadline
Issued 11 September 1998
No resolution recorded
Repair the wasted areas about the hatch cover to the CO2 space prior to return to a U. S. port after sailing foreign. _x001C_ _x001C_ ICLL 66 II/18
Documentation
Issued 11 September 1998
Resolved
Have HRS address the issue that crew cannot read or understand English. Vessel labeling and instructions are mostly in English. Complete prior to departure._x001C_ SOLAS 74 amd IX
Engineering
Issued 11 September 1998
Resolved
Repair the disabled main generator heat exchanger prior to departure. _x001C_ _x001C_ SOLAS 60 I/11
Lifesaving
Issued 11 September 1998
Resolved
Replace all 'unapproved' retroreflective tape on lifesaving appliance with approved tape prior to return to a U. S. port after sailing foreign. _x001C_ _x001C_ SOLAS 74 amd III/30.2.7
Electrical
Issued 11 September 1998
Resolved
Repair the broken explosion proof light on the focsle bulkhead, WX deck, prior to carriage of regulated cargoes. _x001C_ _x001C_ SOLAS 60 II/27
Fire Fighting
Issued 11 September 1998
No resolution recorded
Scale back all packed rust from the deck firemain, locate any further problems and make repairs to assure system tight. Complete prior to returnto a U. S. port after sailing foreign. _x001C_ SOLAS 60 II/56(c)
Fire Fighting
Issued 11 September 1998
No resolution recorded
Replace the broken valve on the foam line adjacent to the main cargo manifolds prior to the carriage of regulated cargoes. _x001C_ _x001C_ SOLAS 74 amd II-2/61
Deck/Cargo
Issued 11 September 1998
Resolved
Provide evidence that the vessel complies or will comply with the emergencytowing arrangements required by SOLAS. System not installed at recent drydocking. Complete prior to departure._x001C_ SOLAS 74 amd A-1/3-4
Deck/Cargo
Issued 11 September 1998
No resolution recorded
Repair the printer on the ballast discharge monitor and prove proper operation of the system prior to carriage of oil cargoes in the United States. _x001C_ MARPOL 73/78 I/9
Electrical
Issued 11 September 1998
No resolution recorded
Provide evidence that the vessel's radios are intrinsically safe. No documentation can be found attesting that the batteries work with the system. Complete prior to usage of radios during carriage of flammable cargoes in the United States. 46 CFR 35.30-30
Lifesaving
Issued 11 September 1998
No resolution recorded
Provide span gas for calibration of the ships combustible gas indicators (along with necessary adapters for testing) prior to carriage of regulated cargoes in the United States. _x001C_ SOLAS 74 amd II-2/59.5
Deck/Cargo
Issued 11 September 1998
No resolution recorded
Repair the hole in the vent pipe to #6 stbd cargo tank (at ladder brace) and torn flame screens on #3 & 6 port vents prior to carriage of flammable cargoes in the United States. _x001C_ SOLAS 74 amd II-2/59.1
Fire Fighting
Issued 11 September 1998
No resolution recorded
Renew the wasted foam lines about the main foam tank prior to the carriage of regulated cargoes. _x001C_ _x001C_ SOLAS 74 amd II-2/61
Fire Fighting
Issued 11 September 1998
No resolution recorded
Provide evidence of servicing for the foam system prior to the carriage of regulated cargoes. _x001C_ _x001C_ SOLAS 74 amd II-2/61
Fire Fighting
Issued 11 September 1998
No resolution recorded
Repair the broken level indicator on the foam tank prior to the carriage ofregulated cargoes. _x001C_ _x001C_ SOLAS 74 amd II-2/61
Engineering
Issued 11 September 1998
Resolved
Repair the broken overspeed on the center generator engine prior to departure._x001C_ _x001C_ SOLAS 60 I/11
Engineering
Issued 11 September 1998
No resolution recorded
Repair the leaking fuel injectors on the main diesel engine prior to returnto a U. S. port after sailing foreign. _x001C_ _x001C_ SOLAS 60 I/11
Engineering
Issued 11 September 1998
No resolution recorded
Clean the excessive oil from about the steering gear, fuel purifiers, generator engines & main bilges prior to return to a U. S. port after sailing foreign. _x001C_ SOLAS 60 I/11
Construction/Loadline
Issued 11 September 1998
No resolution recorded
Permanently repair the miscellaneous holes on the WX deck focsle bulkhead passing into the focsle space (at deck level and overhead) prior to the carriage of regulated cargoes (space not certified as hazardous location). ICLL 66 I/1
Construction/Loadline
Issued 11 September 1998
No resolution recorded
Repair the damaged manhole fitting on the port focsle and make watertight prior to return to a U. S. port after sailing foreign._x001C_ _x001C_ ICLL 66 I/1
Construction/Loadline
Issued 11 September 1998
No resolution recorded
Replace the numerous missing nuts on the main hole covers to the forepeak tank & chain lockers prior to return to a U. S. port after sailing foreign._x001C_ ICLL 66 I/1
Navigation
Issued 11 September 1998
Resolved
Repair the broken rudder angle indicator and calibrate system with bridge prior to departure. _x001C_ _x001C_ SOLAS 74 amd V/12(m)
Navigation
Issued 11 September 1998
Resolved
Remove the compass that is mounted on the raised platform in the steering gear space and mount out of the way of foot traffic prior to departure. _x001C_ SOLAS 60 II/29
Fire Fighting
Issued 11 September 1998
No resolution recorded
Have class evaluate the heat alarms over the cargo pump steam turbines and make modifications or repairs to allow satisfactory operation during cargo ops. Complete prior to carriage of regulated cargoes._x001C_ SOLAS 60 I/11
Construction/Loadline
Issued 11 September 1998
Resolved
Have class evaluate the badly wasted evaporator overboard steam (clearing) line as it is badly wasted and not protected by a sea valve. Make permanent / temporary repairs as necessary. _x001C_ ICLL 66 II/22
Fire Fighting
Issued 11 September 1998
Resolved
Provide extra fire hoses on vessel or hoses designated for potable water. Crew is using machinery space hoses to transfer potable water due to shortage of hoses. Complete prior to departure. _x001C_ SOLAS 60 II/56
Deck/Cargo
Issued 11 September 1998
No resolution recorded
Prove proper operation of the cargo pump shutdowns at all locations for allpumps prior to carriage of regulated cargoes in the United States. _x001C_ _x001C_ 33 CFR 155.780
Deck/Cargo
Issued 11 September 1998
No resolution recorded
Install cargo tank level alarms for all tanks prior to carriage of oil cargoes in the United States. _x001C_ _x001C_ 33 CFR 155.480
Deck/Cargo
Issued 11 September 1998
No resolution recorded
Provide reducers / adapters with bolts, washers, nuts & gaskets to allow two simultaneous transfer connections to 6", 8" & 10" cargoes hoses. Mark all adapters with sizes. Complete prior to carriage of oil cargoes in the United States. 33 CFR 157.410
Deck/Cargo
Issued 11 September 1998
No resolution recorded
Provide 12 barrels for collection of oil pollution wastes & slops prior to carriage of oil cargoes in the United States. _x001C_ _x001C_ 33 CFR 155.205
Documentation
Issued 11 September 1998
No resolution recorded
Provide a USCG approved vessel response plan prior to carriage of oil cargoes in the United States. _x001C_ _x001C_ 33 CFR 155.1030
Engineering
Issued 11 September 1998
No resolution recorded
Remove the oil saturated insulation about the vertical line next to the port turbine and replace prior to return to a U. S. port after sailing foreign. _x001C_ SOLAS 60 I/11
Engineering
Issued 11 September 1998
Resolved
Provide closures for all manifold fittings for the port side machinery tankfills prior to departure. _x001C_ _x001C_ SOLAS 60 I/11
Deck/Cargo
Issued 11 September 1998
No resolution recorded
Renew the wasted cooling line to the heat exchanger in the pump room prior to carriage of regulated cargoes. _x001C_ _x001C_ SOLAS 60 I/11
Accommodation/Occupational Safety
Issued 11 September 1998
No resolution recorded
Repair the various wasted stairs & landings (permanently) throughout the pump room and about various foam monitors prior to carriage of regulated cargoes. _x001C_ SOLAS 60 I/11
Engineering
Issued 11 September 1998
Resolved
Remove or repair the cross connect line between the two main lube oil strainers prior to departure. _x001C_ _x001C_ SOLAS 60 II/28
Electrical
Issued 11 September 1998
Resolved
Remount the light over the steering gear that is hanging by its wiring prior to departure. _x001C_ _x001C_ SOLAS 60 II/27
Documentation
Issued 11 September 1998
No resolution recorded
Provide verification that 'labels & operating instructions for critical equipment' have been translated to the crew's language. This stems from a HRS response to crew language problems on the referenced case which may be consulted for details. SOLAS 74 amd IX
Documentation
Issued 11 September 1998
No resolution recorded
Vessel is operating without a Maintenance System required by the ISM Code under a non conformity from HRS. Due to the noted condition of the vessel,COTPs may want to increase their targeting priority of this vessel during routine port calls until system is in place.
Lifesaving
Issued 11 September 1998
Resolved
Provide spare batteries for the GMDSS radios (the crew is using these for daily use) prior to departure. _x001C_ _x001C_ SOLAS 74 amd III/6.2
Deck/Cargo
Issued 20 November 1990
Resolved
46 CFR 35.30-10 FLAME SCREENS FOR STRIPPING TANK VENT HAD HOLES THROUGH THESCREEN, FOR WHICH #6 OIL WAS BEING CARRIED._x001C_
Construction/Loadline
Issued 20 November 1990
Resolved
SOLAS CHAPTER 2 REG 58,2 WAISTED SCUPPER PIPE CAUSING HOLE FROM MAIN DECK INTO PUMPROOM, WHICH BREECHED FIRE PROOF BOUNDRY.
Electrical
Issued 20 November 1990
Resolved
46 CFR 111.105-43 (b) NEEDS TO HAVE EXPLOSIION PROOF ELECTRICAL LIGHTING INPAINT LOCKER._x001C_ _x001C_ _x001C_
Documentation
Issued 5 September 1989
Resolved
VESSEL'S OIL TRANSFER PROCEDURES WERE MISSING THE DUTIES BY TITLE OF EACH OFFICER REQUIRED FOR EACH OIL TRANSFER OPERATION.
Documentation
Issued 5 September 1989
Resolved
VESSEL COULD NOT PRODUCE A CURRENT RECORD OR EVIDENCE OF A PROPER STATIC LIQUID PRESSURE TEST OF THE CARGO PIPING.
Deck/Cargo
Issued 5 September 1989
Resolved
THE WARNING SIGN REQUIRED BY 46 CFR 35.30-1 (C) WAS NOT PLACED IN THE RADIOROOM.
Navigation
Issued 5 September 1989
Resolved
VESSEL HAD A 1989 EDITION OF THE U.S. LIGHT LIST ON BOARD NOT CORRECTED UP TO DATE.
Navigation
Issued 5 September 1989
Resolved
VESSEL HAD A 1988 EDITION OF THE U.S. COAST PILOT ON BOARD NOT CORRECTED UPTO DATE.
Navigation
Issued 5 September 1989
Resolved
VESSEL WAS FOUND TO HAVE TO HAVE ENTERED THE PORT OF NEW YORK WHEN ITS SATELLITE NAVIGATION UNIT WAS INOPERATIVE.
Navigation
Issued 5 September 1989
Resolved
VESSEL WAS FOUND TO HAVE ENTERED THE PORT OF NEW YORK WHEN ITS ARPA UNIT WAS INOPERATIVE.
Navigation
Issued 5 September 1989
Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITHOUT OBTAINING A DEVIATION FROM REGULATIONS AND REPORTING NONOPERABLE EQUIPEMENT.
Deck/Cargo
Issued 5 September 1989
Resolved
DECK SCUPPERS WERE NOT LEAK FREE DURING CARGO TRANSFER. DRAINS NOT CLOSED BY MECHANICAL MEANS. (UTILIZED WOODEN PLUGS).
Deck/Cargo
Issued 5 September 1989
Resolved
DRAINS AND SCUPPERS NOT CLOSED BY MECHANICAL MEANS ON BUNKER VENT CONTAINMENT AND LUBE OIL LINES.
Navigation
Issued 5 September 1989
Resolved
NO EMERGENCY STEERING INSTRUCTIONS ARE POSTED IN AFT STEERING COMPARTMENT.
Fire Fighting
Issued 5 September 1989
Resolved
NO FOAM ANALYSIS CERTIFICATE ON BOARD.
Deck/Cargo
Issued 5 September 1989
Resolved
NUMBER 3 AND 4 STARBOARD CARGO TANK PRESSURE-VACUUM VALVES MANUAL HANDLES DID NOT OPERATE PROPERLY.
Fire Fighting
Issued 5 September 1989
Resolved
VALVES B AND C IN FOAM ROOMARE NOT LABELED (IN CONTRASTING COLOR).
Deck/Cargo
Issued 8 April 1985
Resolved
MAKE PERMANENT REPAIRS TO #5 AND #7 STARBOARD CARGO TANK GAS VENT LINES LEADING TO THE VENT RISERS IN WAY OF TEMPORARY PATCHES PRIOR TO ENTRY AT NEXT U.S. PORT.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.