Records from 1984 to 1994. Most recent: inspection, 18 October 1994.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 23
18 October 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1353664
21 December 1992
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 504780
3 April 1991
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 342821
31 March 1991
Certificate of Compliance
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 917075
20 February 1990
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 477742
7 September 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1343305
22 August 1989
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 332196
22 August 1989
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 887891
20 August 1989
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 476345
12 January 1989
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 436459
20 August 1988
Certificate of Compliance · MARPOL Annex II Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1041465
5 January 1988
Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1007522
23 December 1987
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1317716
18 December 1987
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1006244
13 April 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 440250
13 April 1987
MARPOL Annex II Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1000840
28 March 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1018570
1 November 1986
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 499862
31 October 1986
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1012277
4 June 1986
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 309267
4 June 1986
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1302115
5 July 1985
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 983385
15 June 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282061
Deck/Cargo
Issued 18 October 1994
Resolved
RENEW WASTED CARGO PIPING CLAMPS (U-BOLTS)
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Deck/Cargo
Issued 18 October 1994
Resolved
MAKE PERMANENT REPAIRS TO WASTED CARGO MANIFOLD CONTAINMENT ON STARBOARD SIDE.
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Fire Fighting
Issued 18 October 1994
Resolved
PERFORM HYDROSTATIC PRESSURE TEST ON ALL FIRE HOSES AND RENEW AS NEEDED._x001C_
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Accommodation/Occupational Safety
Issued 18 October 1994
Resolved
REPLACE BURNT OUT LIGHT BULBS IN ALL CARGO PUMP ROOMS.
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Accommodation/Occupational Safety
Issued 18 October 1994
Resolved
CROP AND RENEW WASTED STRUCTURE SUPPORTING CARGO DECK CATWALK.
Condition: Unknown
Due 2 December 1994
Resolved 2 December 1994
Navigation
Issued 22 August 1989
Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITHOUT CONDUCTING THE TESTS REQUIRED BY AND IN ACCORDANCE WITH 33 CFR 164.25 (A).
Condition: Unknown
Due 3 April 1991
Resolved 22 August 1989
Navigation
Issued 22 August 1989
Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITHOUT HAVING FIRST CONDUCTING AN EMERGENCY STEERING DRILL.
Condition: Unknown
Due 3 April 1991
Resolved 22 August 1989
Navigation
Issued 22 August 1989
Resolved
VESSEL DID NOT HAVE A NAVIGATION RULES INTERNATIONAL / INLAND ON BOARD
Condition: Unknown
Due 3 April 1991
Resolved 22 August 1989
Navigation
Issued 22 August 1989
Resolved
VESSEL DID NOT HAVE COPIES OF 46 CFR PARTS 35 AND 150 ON BOARD.
Condition: Unknown
Due 3 April 1991
Resolved 22 August 1989
Accommodation/Occupational Safety
Issued 22 August 1989
Resolved
REPAIR ALL EYE WASH STATIONS SO OPERATION WILL DIRECT WATER IN DIRECTION ACCESSIBLE TO CREW AND FREE OF SAFETY HAZARDS. EX. HOT STEAM PIPES.
Condition: Unknown
Due 22 August 1989
Resolved 22 August 1989
Deck/Cargo
Issued 23 December 1987
Resolved
PROVE PROPER OPERATION OF HIGH LEVEL ALARMS ON STBD TANKS 1, 3, 4, 5, 7, 8,9, 11 & 12. ALSO PORT TANKS 4, 7 & 12. PROVE HIGH LEVEL ALARM AND OVERFILL ALARM ON #2C CARGO TANK.
Condition: Unknown
Due 23 December 1987
Resolved 23 December 1987
Documentation
Issued 18 December 1987
Resolved
PRODUCE FOR EXAMINATION A SUBCHAPTER O ENDORSEMENT THAT REFLECTS THE CURRENT IMOCOF.
Condition: Unknown
Due 18 December 1987
Resolved 18 December 1987
Deck/Cargo
Issued 18 December 1987
Resolved
PRIOR TO LOADING COMPLIANCE CARGO IN US WATER DEMONSTRATE PROPER OPERATION OF AUDIBLE ALARM ON DECK FOR HIGH LEVEL IN CARGO TANKS AND VERIFY ALARM PANEL VISUAL ALARM COINCIDES WITH APPROPRIATE CARGO TANK BEING TESTED.
Condition: Unknown
Due 18 December 1987
Resolved 18 December 1987
Unknown
Issued 31 October 1986
Resolved
PLACE ON BOARD A NEW CARGOES AND RESTRICTIONS LIST FROM COMDT (G-MTH-1) WHICH REFLECTS LLOYDS CERTIFICATE OF FITNESS DATED 12 AUGUST 1986 AND EXPIRES 24 OCTOBER 1989.
Condition: Unknown
Due 31 October 1986
Resolved 31 October 1986
Documentation
Issued 4 June 1986
Resolved
46CFR35.30-1(B) NO WARNING SIGN AT GANGWAY THAT STATES "NO OPEN LIGHTS, NO SMOKING, NO VISITORS".
Condition: Unknown
Due 4 June 1986
Resolved 4 June 1986
Fire Fighting
Issued 4 June 1986
Resolved
REGULATION 20.2 CHAPTER II-2 SOLAS. NO FIRE CONTROL PLAN OUTSIDE THE DECKHOUSE.
Condition: Unknown
Due 4 June 1986
Resolved 4 June 1986
Deck/Cargo
Issued 4 June 1986
Resolved
33CFR156.120(O) THE SCUPPERS WERE NOT PROPERLY CLOSED DURING AN OIL TRANSFER OPERATION.
Condition: Unknown
Due 4 June 1986
Resolved 4 June 1986
Deck/Cargo
Issued 4 June 1986
Resolved
OBTAIN PERMISSION FROM LOCAL CAPTAIN OF THE PORT PRIOR TO USING DROPLINES
Condition: Unknown
Due 4 June 1986
Resolved 4 June 1986
Deck/Cargo
Issued 4 June 1986
Resolved
CARGOES WHICH ARE WATER REACTIVE SHALL NOT BE DISCHARGED OR LOADED THROUGH PUMPROOMS.
Condition: Unknown
Due 4 June 1986
Resolved 4 June 1986
Documentation
Issued 4 June 1986
Resolved
PLACE ON BOARD NEW CARGOES AND RESTRICTIONS LIST WHICH REFLECTS NEW IMO CERTIFICATE OF FITNESS ISSUED BY LLOYDS ON 20 MAY 86.
Condition: Unknown
Due 4 June 1986
Resolved 4 June 1986
Deck/Cargo
Issued 5 July 1985
Resolved
PRIOR TO ENTERING U. S. WATERS AFTER 20 JULY 1985 PROVIDE TO COMDT G-MTH-1 CLASSIFICATION SOCIETY AND FLAG ADMINISTRATION CERTIFICATION VERIFYING THATTHE DECK TANK P/V VALVES ARE HIGH VELOCITY VALVES.
Condition: Unknown
Due 5 July 1985
Resolved 5 July 1985
Deck/Cargo
Issued 5 July 1985
Resolved
PRIOR TO ENTERING U. S. WATERS AFTER 20 JULY 1985 MAKE PERMANENT REPAIRS TO INERT GAS GENERATOR.
Condition: Unknown
Due 5 July 1985
Resolved 5 July 1985
Deck/Cargo
Issued 5 July 1985
Resolved
DROPLINES WITH CONNECTIONS WHICH ARE NOT FIXED SHALL NOT BE USED TO LOAD CARGO IN U. S. WATERS, UNLESS PERMISSION IS OBTAINED FROM THE LOCAL CAPTAINOF THE PORT AS REQUIRED BY COMDT (G-MHM-1) LETTER 16455 DATED 24 FEB 1981.
Condition: Unknown
Due 5 July 1985
Resolved 5 July 1985
Deck/Cargo
Issued 5 July 1985
Resolved
CARGOES WHICH ARE WATER REACTIVE (REF: SECTION 4.15.2 OF THE IMO CHEMICAL CODE) SHALL NOT BE LOADED OR DISCHARGED THROUGH PUMPROOMS.
Condition: Unknown
Due 5 July 1985
Resolved 5 July 1985