PELICAN

PELICAN is a 1980 passenger vessel (inspected). The Coast Guard has recorded 57 inspections since 1986, most recently in December 2025, along with 107 deficiencies and 1 casualty investigation in 2013.

Records from 1986 to 2025. Most recent: inspection, 8 December 2025.

Built
1980
Last inspected
8 December 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDL9558
Flag
UNITED STATES
367321090
Maury page id
psix-51864

Inspections, by type

…with no type recorded6
Years with a record 33 calendar years (1986–2025)
The 57 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)38.4 ft × 14.0 ft × 5.7 ft
Registered tonnagegross 19 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEUVILLE BOAT WORKS INC · LOREAUVILLE, LA, UNITED STATES · built 1980
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPHILADELPHIA, PA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 12 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it19 - Regulatory (Subpart C or D), Gross Ton
13 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL9558MMSI 367321090 · active · voluntarily equipped · granted 30 January 2021, expires 30 January 2031
WDI9434MMSI 367748570 · expired · compulsorily equipped · granted 29 July 2016, cancelled 5 September 2026
WDE2149MMSI 367321090 · expired · compulsorily equipped · granted 2 November 2007, cancelled 6 January 2018
WTA4743MMSI not assigned · expired · compulsorily equipped · granted 12 March 1998, cancelled 9 August 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 57

8 December 2025 Administrative Inspection · Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8278917
21 November 2024 Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8037947
17 November 2023 Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7826388
7 November 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7590374
29 November 2021 Deficiency Check · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7358375
13 September 2021 Drydock Exam · Examination of Repairs · Simplified Stability Test · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7311038
20 April 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6941561
18 April 2019 COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6665662
24 July 2018 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6488953
13 April 2018 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6392336
26 June 2017 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6201097
23 February 2016 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5820100
10 February 2016 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5814348
21 October 2014 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5026479
1 September 2011 COI Inspection · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4133163
7 December 2009 Damage Survey · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3646007
7 April 2009 Administrative Inspection · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3445675
27 May 2008 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3219119
6 April 2006 Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2618042
14 April 2005 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2333886
4 March 2005 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2332045
28 October 2003 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1943088
28 August 2003 In-Service Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1889894
7 June 2003 Type not recorded
No type recorded · Station Fort Macon · USCG East District (CGD-E) · Activity 1814786
29 April 2003 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1788198
7 March 2003 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1753952
16 April 2002 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1604924
3 May 2001 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1429544
30 March 2001 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1417242
17 April 2000 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1449310
11 May 1999 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1399107
13 April 1999 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1449162
4 May 1998 Re-Inspection · Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 790350
12 May 1997 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1104310
9 December 1996 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1400463
15 August 1996 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1087759
10 May 1996 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1082083
17 June 1995 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 59770
21 April 1995 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1414451
12 December 1994 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 834869
19 July 1994 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1171216
6 July 1994 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 862215
12 July 1993 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1152655
9 December 1992 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1137225
17 November 1992 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1138107
8 July 1992 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 946707
8 July 1991 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 934480
2 April 1991 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 927696
6 December 1990 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1226908
10 July 1990 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 936285
24 April 1990 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1225339
31 July 1989 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1350808
11 July 1989 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1044761
17 May 1989 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1042126
8 July 1988 Hull Examination · Plan Review "T" Boat · COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1341724
4 March 1988 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1027670
21 March 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1305975

Deficiency record · 107

09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 February 2026 Resolved
All other vessels must undergo an inspection for certification as specified in § 176.404 and annual inspection as specified in paragraph (b)(1) of this section. If the annual inspection reveals deficiencies in your vessel's maintenance, you must make any or all repairs or improvements within the time period specified by the [name withheld] experienced strong smell of diesel fumes coming from lazarette on 08DEC25. Vessel has not cleaned space or identified origin of fumes and must prior to carry passengers or cargo 46 CFR 176.500(b)(1)(iii)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 April 2026
Resolution: Bottom of the tank cropped and renewed. Verified the tank remaining metal was sound & then once repairs were complete MIs attended hydrotest. Once tank was re-installed, MIs tested emer. fuel shut off, verified ground, and ensured tank mounted securely.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 December 2025 Resolved
All enclosed spaces within the vessel shall be properly vented or ventilated. MIs found the aft most compartment with strong smell of diesel. Clean and identify what's causing the smell. 46 CFR 177.20-1(a) (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2025
Resolved 24 April 2026
Resolution: Bottom of the tank cropped and renewed. Verified the tank remaining metal was sound & then once repairs were complete MIs attended hydrotest. Once tank was re-installed, MIs tested emer. fuel shut off, verified ground, and ensured tank mounted securely.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 December 2025 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officers in Charge, Marine Inspection. MIs found extinguisher secured with a bungee cord. Replace with manufactures approved mounting bracket. 46 CFR 181.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2025
Resolved 9 January 2026
Resolution: Attended vessel and verified manufacturers mount was installed
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 8 December 2025 Resolved
All Vessels except non-selfpropelled vessels shall be provided with suitable steering apparatus. MIs observed accumulation of oil on steering line under helm. Clean impacted area and rectify leak. 46 CFR 182.30-5(a) (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2025
Resolved 9 January 2026
Resolution: Attended vessel and verified connections were snug, and oil accumulation was cleaned
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 8 December 2025 Resolved
Each hatch exposed to the weather must be watertight, except that the following hatches may be weathertight, each hatch on a vessel that operates only on protected waters. The gasket on the weathertight hatch going into the lazarette had become deteriorated. Replace to the satisfaction of MI. 46 CFR 171.124(a)(3)(Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2025
Resolved 9 January 2026
Resolution: Attended vessel and verified new gasket installed and would provide a proper seal
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 December 2025 Resolved
Except as provided otherwise in this subpart, all electrical equipment including motors, generators, controllers, distribution panels, etc., shall be be dripproof protected. MI found a missing cap in the switch panel located at the helm under a window allowing for water drip directly on exposed wires. Seal panel to the satisfaction of attending MI. 46 CFR 183.10-10(a)(Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2025
Resolved 9 January 2026
Resolution: Attended vessel and verified electrical box had a waterproof cap installed
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 8 December 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2025
Resolved 18 December 2025
Resolution: Vessel submitted MIS report to USCG and MIs conducted a DAPI audit with satisfactory results
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 November 2024 Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. Engine block heaters wiring installations are not a permanent installation. Port and starboard block heaters are wired with a flexible cord running through the port side ventilation intake for the engine room. Replace with permanent installation to the requirements of new electrical installations of subchapter T or remove flexible cords. 46 CFR 183.10-20 (a) (Old T)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 21 November 2024
Resolution: Removed extension cords until a permanent installation is completed.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 21 November 2024 Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arrestors. The vessels diesel fuel tank vent pipe was missing the flame screen. Provide evidence of newly fitted flame screen on the vent pipe to the satisfaction of the MI. 46 CFR 182.20-35(d) (OLD T)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 21 November 2024
Resolution: Installed new flame screen on vent piping.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 21 November 2024 Resolved
At each initial and subsequent inspection for certification and reinspection the firefighting equipment of all vessels shall be inspected and all deficiencies found shall be corrected. MI discovered electrical cord passing through a hole in the side of the starboard deck ventilation intake allowing egress of fixed fire system agent in the event of an emergency. Owner/Operator shall remove cord and provide permanent fixture to contain ventilation to the satisfaction of the MI. 46 CFR 182.20-35(d) (OLD T)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 21 November 2024
Resolution: Cords were removed during the inspection and hole was properly sealed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 November 2022 Resolved
Pre-engineered fixed gas fire extinguishing system must be installed in accordance with the manufactures instructions. Vessel owner reported an issue with their Fire Boy and replacement parts are experiencing a shipment delay. Provide an extra 40-B:C in the vicinity of the machinery space exit while Fire Boy is decommissioned. Once parts are received for the Fire Boy, the Marine Inspector will attend to commission the Pre engineered fire extinguishing system.
Action required: 705 - Other - as specified
Resolved 4 January 2023
Resolution: Vessel received parts and installed new Fire Boy equipment. Satisfactorily tested in presence of MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 November 2021 Resolved
46CFR16.401(b) EAP training program: An EAP training program must be conducted for the employer’s crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer's supervisory personnel. Supervisory personnel must receive at least 60 minutes of training.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 23 December 2021
Resolution: verified training and certs
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 November 2021 Resolved
47CFR 80.59(a)(2) 46CFR184.502 A certification that the ship has passed an inspection must be entered into the ship’s log by the technician. An inspection of the bridge-to-bridge radio stations on board vessels subject to the Vessel Bridge-to-Bridge Radiotelephone Act must be conducted by the same FCC-licensed technician. Provide an FCC safety radio telephony certificate that has been issued to the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 23 December 2021
Resolution: verified cert
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 30 November 2021 Resolved
47CFR80.905 46CFR184.502 Vessels operated solely within 20 nautical miles of th eland must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of 47CFR80.1101(c). Vessel does not have VHF/DSC radio with MMSI number programmed with position input.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 23 December 2021
Resolution: verified mssi and position
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 November 2021 Resolved
46CFR180.71 A number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. Each life jacket must be approved in accordance with either 160.002, 160.005, 160.055. Each life jacket must be marked IAW 46CFR185.604(b). Provide 02 child sized life jackets labeled in accorance with CFR.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 23 December 2021
Resolution: verified and inspected 02 child life jackets
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 November 2021 Resolved
46CFR185.726(e) Each floating waterlight must be approved IAW 46CFR161.010 in subchapter Q of this chapter. Replace battery in life buoy floating waterlight with battery approved by the light manufacturer. Replace battery in life buoy floating water light with approved replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 23 December 2021
Resolution: verified and inspected water light operations and battery
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 November 2021 Resolved
46CFR181.610 A vessel not required to have a power driven fire pump must have atleast three 2.5 gallon buckets with an attached lanyard. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Provide 3 fire buckets of 2.5 gallons, with attached lanyard sufficient to use the bucket as intended. Labeled properly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 23 December 2021
Resolution: verified and inspected 03 fire buckets
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 November 2021 Resolved
46CFR182.520(a) A vessel must be provided with bilge pumps IAW Table 182.520(a). Provide a fixed power bilge pump that has sufficient lift and head characteristics to discharge at least 10 gallons per minute.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 23 December 2021
Resolution: op tested new bigle pump
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 November 2021 Resolved
46CFR182.430 The design of all exhaust systems must ensure minimum risk of injury to personnel. Protection must be provided in compliance with 177.970 of this chapter at such locations where persons or equipment might come in contact with an exhaust pipe. Exhaust gas must not leak from the piping or any connections. Repair exhaust leak and replace damaged exhaust lagging.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 23 December 2021
Resolution: verified proper repair
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 April 2019 Resolved
The employer shall provide an Employee Assistance Program to all crewmembers [name withheld] must include education and training for crewmembers. Provide education information/displays outlined in 46 CFR 16.401(a) and training program information outined in 16.401(b).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2019
Resolved 29 May 2019
Resolution: EAP information was posted.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 April 2019 Resolved
In port lazarette, stiffeners were missing from previous side shell insert. Repair to original scantlings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2019
Resolved 29 May 2019
Resolution: Scantling were returned to original scantlings.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 22 April 2019 Resolved
Penetrations in watertight bulkheads must have means to make them watertight. Plug empty wire run bulkhead between laz and engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2019
Resolved 29 May 2019
Resolution: Penetrations had been filled, making them watertight.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 22 April 2019 Resolved
Each hatch exposed to the weather must be weathertight if the vessel operates only on protected waters. Replace gasket on engine room hatch to make weathertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2019
Resolved 29 May 2019
Resolution: New gaskets were installed on both engine room hatches.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 April 2019 Resolved
Portable extinguishers must be inspected and maintained IAW NFPA 10. The operator must provide satisfactory evidence of the required servicing to the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2019
Resolved 29 May 2019
Resolution: Fire extinguishers were serviced in May 2019.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 24 July 2018 Resolved
The master and crew shall be familiar with the content of the emergency instructions, which shall be posted on board. The vessel does not have emergency instructions posted. Post emergency instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2018
Resolved 7 August 2018
Resolution: Vessel provided emergency instructions.
Construction/Loadline › Hull › Side Shell
Issued 23 February 2016 Resolved
Crop and renew aft stbd quarter from transom fwd to 6" past first frams, vertically from upper rub rail to chine.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 March 2016
Resolved 10 March 2016
Construction/Loadline › Hull › Side Shell
Issued 23 February 2016 Resolved
SH03: Crop and renew (02) stbd midship side hull holes, with 18" x 18" section centered on frames.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 March 2016
Resolved 10 March 2016
Construction/Loadline › Hull › Weld
Issued 23 February 2016 Resolved
SH04: Grind and weld vertical stem weld.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 March 2016
Resolved 10 March 2016
Construction/Loadline › Hull › Side Shell
Issued 23 February 2016 Resolved
SH05: Crop and renew aft port quarter from transom fwd to to 6" past first frams, vertically from the lower rubrail to chine.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 March 2016
Resolved 10 March 2016
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 23 February 2016 Resolved
SH06:Crop and renew both main engine exhaust piping thru aft e/r bulkhead to encompass existing 18" x 18" plate inserts.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 22 March 2016
Resolved 10 March 2016
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 10 February 2016 Resolved
Provide proper operation of emergency fuel shut off valve.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2016
Resolved 10 February 2016
Resolution: demonstrated operation of valave
Construction/Loadline › Structures › Transverse Bulkhead
Issued 10 February 2016 Resolved
Repair engine room aft bulkhead at exhaust manifolds to make watertight
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 14 July 2017
Resolution: MI team confirmed repairs during annual inspection.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 10 February 2016 Resolved
Remove excess oil from bilges in engine room and steering compartment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2016
Resolved 10 February 2016
Resolution: Both compartments were cleaned out
Documentation › Logs/Records › Logbook (official)
Issued 10 February 2016 Resolved
Provide logs for drills and maintenance.
Action required: 705 - Other - as specified
Due 17 February 2016
Resolved 10 February 2016
Resolution: Vessel has created a system for logging drills/mainenance
Documentation › Logs/Records › Drug Test Records
Issued 10 February 2016 Resolved
Provide DAPI documentation and enrollment IAW audit form provided.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 February 2016
Resolved 2 March 2016
Resolution: Provided proper documentation.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 February 2016 Resolved
Receive annual inspection credit prior to carrying passengers
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2016
Resolved 10 February 2016
Resolution: Completed annual insoection.
Documentation › Logs/Records › Logbook (official)
Issued 10 February 2016 Resolved
Provide means to log passenger count for each voyage.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 February 2016
Resolved 10 February 2016
Resolution: Vessel created log to track passenger counts.
Engineering › Bilge Water Management System › Piping
Issued 1 September 2011 Resolved
Replace aluminum coupling on brass overboard valve at bilge pump discharge.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2011
Resolution: Aluminum coupling replaced.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 1 September 2011 Resolved
Have B-II fire extinguisher located on aft deck serviced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2011
Resolution: Extinguisher was serviced and placed back on board the vessel
Operations/Management › Drills/Instruction › Fire
Issued 1 September 2011 Resolved
Demonstrate proper performance of fire and man overboard drill.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2011
Resolution: Conducted MOB and Fire drill with crew.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 1 September 2011 Resolved
Provide adequate amount of serviceable visual distress signals. Vessel required to have 6 red hand/6 orange day flares due to oceans route.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2011
Resolution: Adequate visual distress flares provided.
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 1 September 2011 Resolved
Show proof of captains license, radio operators permit, CPR and first aid, and drug consortium enrollment.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2011
Resolution: Crew documents were provided
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 September 2011 Resolved
Provide waterlight on ring buoy in accordance with COI.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2011
Resolution: Waterlight provided.
Operations/Management › Drills/Instruction › Fire
Issued 1 September 2011 Resolved
Show proof of vessel logbook to include drills, EPIRB testing, and passenger count.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2011
Resolution: Vessel provided logbook with initial entries into drills, EPIRB tests, etc.
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 7 December 2009 Resolved
Repair Starboard main engine propeller.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 December 2009
Resolved 10 December 2009
Resolution: Prop and shaft replaced with new units, satisfactory sea-trial conducted.
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 April 2009 Resolved
Properly cap or remove old keel cooler piping in engine room (aft centerline)
Due 7 May 2009
Resolved 10 August 2009
Resolution: O/O capped keel cooler piping.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 April 2009 Resolved
Properly repair broken handrails
Due 7 May 2009
Resolved 10 August 2009
Resolution: Handrails were repaired.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 27 May 2008 Resolved
Plug open stuffing tubes between engineroom and aft laz
Condition: Improper/Lack of Maintenance
Due 19 June 2008
Resolved 19 June 2008
Resolution: Plugged stuffing tubes
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 May 2008 Resolved
Replace asprin and eyewash
Condition: Improper/Lack of Maintenance
Due 19 June 2008
Resolved 19 June 2008
Resolution: Replaced aspirin and eyewash
Communications › Alarms/Indicators › High Water Alarm
Issued 27 May 2008 Resolved
Mount float switch and high level alarms.
Condition: Improper/Lack of Maintenance
Due 19 June 2008
Resolved 19 June 2008
Resolution: Mounted float switch
Engineering › Fuel Oil Service System › Hose
Issued 27 May 2008 Resolved
Replace split fuel hose on filter next to generator.
Condition: Improper/Lack of Maintenance
Due 19 June 2008
Resolved 19 June 2008
Resolution: Replaced fuel line
Lifesaving › Lifefloat › Serviceable
Issued 27 May 2008 Resolved
Repair middle lifefloat strap and renew worn line.
Condition: Improper/Lack of Maintenance
Due 19 June 2008
Resolved 19 June 2008
Resolution: Repaired strap
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 27 May 2008 Resolved
Add lights to lifejackets missing lights.
Condition: Improper/Lack of Maintenance
Due 19 June 2008
Resolved 19 June 2008
Resolution: Added lights
Lifesaving › Lifebuoys › Serviceable
Issued 27 May 2008 Resolved
Replace worn lifering and line
Condition: Improper/Lack of Maintenance
Due 19 June 2008
Resolved 19 June 2008
Resolution: Replace lifering and line.
Lifesaving › Lifefloat › Float-free Link
Issued 27 May 2008 Resolved
Connect life float to weak link
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2008
Resolved 4 June 2008
Resolution: Replace line and connected to lifefloat
Fire Fighting › Ventilation Systems › Ducts
Issued 27 May 2008 Resolved
Replace missing engineroom vent covers
Condition: Improper/Lack of Maintenance
Due 19 June 2008
Resolved 19 June 2008
Resolution: Installed new vents
Documentation › Certificates/Documents › FCC SSL
Issued 27 May 2008 Resolved
Provide proof of FCC SSL.
Condition: Improper/Lack of Maintenance
Due 19 June 2008
Resolved 19 June 2008
Resolution: Has FCC SSL
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 27 May 2008 Resolved
Carry light list, tide, and tidal current table
Condition: Improper/Lack of Maintenance
Due 19 June 2008
Resolved 19 June 2008
Resolution: Carrying all required pubs
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 27 May 2008 Resolved
Replace worn BIII fire ext port side deck
Condition: Improper/Lack of Maintenance
Due 19 June 2008
Resolved 19 June 2008
Resolution: Replace worn fire ext
Electrical › Lighting (emergency) › Lighting Fixture
Issued 27 May 2008 Resolved
Repair e-lights in cabin
Condition: Improper/Lack of Maintenance
Due 19 June 2008
Resolved 19 June 2008
Resolution: Repaired light
Engineering › Fuel Oil Service System › Vent Pipe
Issued 6 April 2006 Resolved
Replace Flame Screens
Condition: Improper/Lack of Maintenance
Due 13 April 2006
Resolved 13 April 2006
Resolution: Corrected
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 April 2006 Resolved
Needs to place machinery guards around belts on main engines.
Condition: Improper/Lack of Maintenance
Due 13 April 2006
Resolved 13 April 2006
Resolution: Corrected
Lifesaving › Lifefloat › Netting
Issued 14 April 2005 Resolved
Properly repair the metal rings in the two large life floats and replace the lifelines.
Action required: 705 - Other - as specified
Resolved 11 May 2005
Resolution: Welded rings and lifelines replaced.
Lifesaving › Lifefloat › Capacity
Issued 14 April 2005 Resolved
Replace the small, 6 person life float.
Action required: 705 - Other - as specified
Resolved 11 May 2005
Resolution: New life float installed.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 14 April 2005 Resolved
Provide lights for all lifejackets required by the COI
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 11 May 2005
Resolution: Lights for all lifejackets provided
Communications › Radio Communications › EPIRB
Issued 14 April 2005 Resolved
Provide new EPIRB battery, hydrostatic release unit, and NOAA registration.
Action required: 705 - Other - as specified
Resolved 11 May 2005
Resolution: Cat 1 EPIRB properly installed.
Engineering › Sea-water System (primary cooling)
Issued 28 August 2003 Resolved
make proper repair to raw water suction hose on port engine. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 September 2003
Resolved 3 September 2003
Resolution: corrected sat
Engineering › Bilge Water Management System
Issued 28 August 2003 Resolved
make permanent connection for bilge discharge hose LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 September 2003
Resolved 3 September 2003
Resolution: corrected sat
Lifesaving › Buoyant Apparatus
Issued 28 August 2003 Resolved
provide dunnage for life float separtation LEGACY COMPONENT DESC: separation
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 September 2003
Resolved 3 September 2003
Resolution: corrected sat
Documentation › Certificates/Documents
Issued 28 August 2003 Resolved
provide certificate of documentation showing new ownership LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 705 - Other - as specified
Due 11 September 2003
Resolved 3 September 2003
Resolution: corrected sat
Navigation › Piloting/Steering
Issued 28 August 2003 Resolved
Provide charts for local area LEGACY COMPONENT DESC: Marine Charts
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 September 2003
Resolved 3 September 2003
Resolution: corrected sat
Electrical › Electrical Distribution System (service)
Issued 28 August 2003 Resolved
properly secure dead end wire in sheelhouse overhead LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 September 2003
Resolved 3 September 2003
Resolution: corrected sat
Lifesaving › Visual Distress Signals (General)
Issued 28 August 2003 Resolved
provide and label box for distress signals LEGACY COMPONENT DESC: Storage
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 September 2003
Resolved 3 September 2003
Resolution: corrected sat
Documentation › Markings/Placards
Issued 28 August 2003 Resolved
Provide lifejacket donning placard LEGACY COMPONENT DESC: Lifejacket donning placard
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 September 2003
Resolved 3 September 2003
Resolution: corrected sat
Documentation › Manifests/Lists
Issued 28 August 2003 Resolved
provide emergency broadcast placard LEGACY COMPONENT DESC: Muster List/Emergency Instructions
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 September 2003
Resolved 3 September 2003
Resolution: corrected sat
Lifesaving › Lifejacket/PFD (General)
Issued 28 August 2003 Resolved
Separate and relabel child lifejacket stowage LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 September 2003
Resolved 3 September 2003
Resolution: corrected sat
Electrical › Electrical Distribution System (service)
Issued 28 August 2003 Resolved
provide electrical outlet box cover below operators seat LEGACY COMPONENT DESC: Outlet Box
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 September 2003
Resolved 3 September 2003
Resolution: corrected sat
Navigation › Collision/Grounding Avoidance
Issued 28 August 2003 Resolved
repair fractured window LEGACY COMPONENT DESC: Navigation Bridge Visibility
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 September 2003
Resolved 3 September 2003
Resolution: corrected sat
Communications › Audible Communications
Issued 28 August 2003 Resolved
prove proper operation of secondary horn LEGACY COMPONENT DESC: Horn/Whistle
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 September 2003
Resolved 3 September 2003
Resolution: corrected sat
Communications › Radio Communications
Issued 16 April 2002 Resolved
MAKE REPAIRS OR REPLACE SSB RADIO. VESSEL IS LIMITED TO 20 MILES FROM SHORE UNTIL PROVIDED. LEGACY COMPONENT DESC: Radiotelephone Transveiver (2-4 MHz)
Condition: Unknown
Due 16 May 2002
Resolved 8 October 2003
Lifesaving › Buoyant Apparatus
Issued 16 April 2002 Resolved
MAKE REPAIRS TO WATER LIGHT FOR LIFE FLOAT. LEGACY COMPONENT DESC: WATERLIGHT
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2002
Resolution: WATERLIGHT WAS REPAIRED PRIOR TO END OF INSPECTION.
Navigation
Issued 4 May 1998 Resolved
REPLACE PORT RUDDER RAM PIN.
Condition: Unknown
Due 4 June 1998
Resolved 11 May 1998
Documentation
Issued 4 May 1998 Resolved
PROVIDE FCC ISSUED SAFETY RADIO TELEPHONE CERTIFICATE. VESSEL IS NOT TO OPERATE UNTIL PROVIDED.
Condition: Unknown
Due 4 May 1998
Resolved 11 May 1998
Lifesaving
Issued 4 May 1998 Resolved
PROVIDE TWO ADDITIONAL ADULT TYPE I PFD'S. VESSEL LIMITED TO TWENTY SIX PERSONS UNTIL PROVIDED.
Condition: Unknown
Due 4 May 1998
Resolved 11 May 1998
Lifesaving
Issued 4 May 1998 Resolved
PROVIDE FCC TYPE ACCEPTED CATEGORY I, 406 MHZ EPIRB INSTALLED TO AUTOMATICALLY FLOAT FREE AND ACTIVATE.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Lifesaving
Issued 4 May 1998 Resolved
PROVIDE SIX RED HAND HELD FLARES. VESSEL IS NOT TO OPERATE UNTIL PROVIDED.
Condition: Unknown
Due 4 May 1998
Resolved 11 May 1998
Lifesaving
Issued 4 May 1998 Resolved
REPLACE TWO CRACKED WINDOWS STBD SIDE PASSENGER AREA.
Condition: Unknown
Due 4 June 1998
Resolved 11 May 1998
Lifesaving
Issued 12 May 1997 Resolved
PRIOR TO OPERATING WITH PASSENGERS, INSTALL RETRO-REFLECTIVE MATERIEL ON RING BUOY.
Condition: Unknown
Due 13 May 1997
Resolved 27 May 1997
Fire Fighting
Issued 12 May 1997 Resolved
PRIOR TO OPERATING WITH PASSENGERS, PROVIDE (1) B-I PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 13 May 1997
Resolved 27 May 1997
Fire Fighting
Issued 12 May 1997 Resolved
PRIOR TO OPERATING WITH PASSENGERS, REPAIR HOSE ON PORTABLE HAND PUMP, WHERE HOLED.
Condition: Unknown
Due 13 May 1997
Resolved 27 May 1997
Navigation
Issued 12 May 1997 Resolved
PRIOR TO OPERATING WITH PASSENGERS, DEMONSTRATE PROPER OPERATION OF PORT SIDE RUNNING LIGHT.
Condition: Unknown
Due 13 May 1997
Resolved 27 May 1997
Lifesaving
Issued 12 May 1997 Resolved
CONDUCT SATISFACTORY UNDERWAY DRILLS IN THE PRESENCE OF THE USCG, NO LATER THAN 19 MAY 1997.
Condition: Unknown
Due 17 May 1997
Resolved 27 May 1997
Engineering
Issued 12 May 1997 Resolved
RELABEL EMERGENCY FUEL SHUT-OFF VALVE NO LATER THAN 12 JUNE 1997.
Condition: Unknown
Due 17 June 1997
Resolved 27 May 1997
Lifesaving
Issued 10 May 1996 Resolved
PRIOR TO OPERATING BEYOND TWENTY (20) MILES FROM LAND, PROVIDE EPIRB WITH VALID/CURRENT BATTERY.
Condition: Unknown
Due 10 May 1996
Resolved 15 August 1996
Fire Fighting
Issued 10 May 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, PROVIDE ADDITIONAL B-II PORTABLE F/E.
Condition: Unknown
Due 10 May 1996
Resolved 15 August 1996
Documentation
Issued 10 May 1996 Resolved
PROVIDE PROOF OF ENROLLMENT IN VALID DRUG TESTING PROGRAM.
Condition: Unknown
Due 10 May 1996
Resolved 15 August 1996
Construction/Loadline
Issued 10 May 1996 Resolved
REPAIR FRACTURES (TOTAL OF 22) IN WAY OF PORT & STBD SIDE TRANSVERSE FRAMING IN WAY OF PILOT HOUSE SUPPORTS.
Condition: Unknown
Due 10 May 1996
Resolved 15 August 1996
Documentation
Issued 10 May 1996 Resolved
PROVIDE STABILITY LETTER AND POST ON VESSEL.
Condition: Unknown
Due 26 June 1996
Resolved 15 August 1996
Lifesaving
Issued 10 May 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, PROVIDE ADEQUATE WEAK-LINK FOR BOTH (2)12-PERSON LIFE FLOATS.
Condition: Unknown
Due 10 May 1996
Resolved 15 August 1996
Accommodation/Occupational Safety
Issued 10 May 1996 Resolved
PRIOR TO ALLOWING PASSENGERS ON UPPER DECK, INSTALL ADDITIONAL RAIL COURSESTO ENSURE NMT 12" BETWEEN EACH COURSE.
Condition: Unknown
Due 26 June 1996
Resolved 15 August 1996
Accommodation/Occupational Safety
Issued 10 May 1996 Resolved
PRIOR TO ALLOWING PASSENGERS ON UPPER DECK, PROVIDE PLACARD FOR MAX PERSONSALLOWED AS PER STABILITY LETTER.
Condition: Unknown
Due 15 August 1996
Resolved 15 August 1996
Documentation
Issued 6 July 1994 Resolved
PROVIDE OIL POLLUTION PLACARD
Condition: Unknown
Due 6 July 1994
Resolved 6 July 1994
Lifesaving
Issued 6 July 1994 Resolved
PROVIDE APPROVED RING BOUY
Condition: Unknown
Due 6 July 1994
Resolved 6 July 1994
Accommodation/Occupational Safety
Issued 6 July 1994 Resolved
PROVIDE FLAME SCREEN FOR MSD VENT (30 X 30 MESH)
Condition: Unknown
Due 6 July 1994
Resolved 6 July 1994
Navigation
Issued 8 July 1992 Resolved
PROVIDE SATISFACTORY RADIO TEST ON SSB, 2182MHZ, VESSEL RESTRICTED TO 20 MILE ROUTE UNTIL COMPLETED.
Condition: Unknown
Due 10 July 1992
Resolved 10 July 1992
Lifesaving
Issued 8 July 1992 Resolved
PROVIDE A 406 MHZ EPIRB ON BOARD VESSEL NO LATER THAN 01JAN93.
Condition: Unknown
Due 8 July 1992
Resolved 8 July 1992
Lifesaving
Issued 8 July 1992 Resolved
REMOVE DIESEL FUEL FROM STEERING COMPT AND DISPOSE OF PROPERLY PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 8 July 1992
Resolved 8 July 1992

Casualty record · 1

10 January 2013Routine · role: Involved in a Marine Casualty · activity 4522337
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.