Inspection record

Last inspected 8 December 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL9558
Flag
UNITED STATES
Maury page id
psix-51864

Documentation record

Registered dimensions (L × B × D)38.4 ft × 14.0 ft × 5.7 ft
Registered tonnagegross 19 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEUVILLE BOAT WORKS INC · LOREAUVILLE, LA, UNITED STATES · built 1980
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPHILADELPHIA, PA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 12 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it19 - Regulatory (Subpart C or D), Gross Ton
13 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 13 inspections, each with its date, unit and type; 37 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

8 December 2025 Administrative Inspection · Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8278917
21 November 2024 Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8037947
17 November 2023 Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7826388
7 November 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7590374
29 November 2021 Deficiency Check · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7358375
13 September 2021 Drydock Exam · Examination of Repairs · Simplified Stability Test · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7311038
20 April 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6941561
18 April 2019 COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6665662
24 July 2018 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6488953
13 April 2018 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6392336
26 June 2017 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6201097
23 February 2016 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5820100
10 February 2016 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5814348

Deficiency record · 37

09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 February 2026 Resolved
All other vessels must undergo an inspection for certification as specified in § 176.404 and annual inspection as specified in paragraph (b)(1) of this section. If the annual inspection reveals deficiencies in your vessel's maintenance, you must make any or all repairs or improvements within the time period specified by the [name withheld] experienced strong smell of diesel fumes coming from lazarette on 08DEC25. Vessel has not cleaned space or identified origin of fumes and must prior to carry passengers or cargo 46 CFR 176.500(b)(1)(iii)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 April 2026
Resolution: Bottom of the tank cropped and renewed. Verified the tank remaining metal was sound & then once repairs were complete MIs attended hydrotest. Once tank was re-installed, MIs tested emer. fuel shut off, verified ground, and ensured tank mounted securely.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 December 2025 Resolved
All enclosed spaces within the vessel shall be properly vented or ventilated. MIs found the aft most compartment with strong smell of diesel. Clean and identify what's causing the smell. 46 CFR 177.20-1(a) (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2025
Resolved 24 April 2026
Resolution: Bottom of the tank cropped and renewed. Verified the tank remaining metal was sound & then once repairs were complete MIs attended hydrotest. Once tank was re-installed, MIs tested emer. fuel shut off, verified ground, and ensured tank mounted securely.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 December 2025 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officers in Charge, Marine Inspection. MIs found extinguisher secured with a bungee cord. Replace with manufactures approved mounting bracket. 46 CFR 181.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2025
Resolved 9 January 2026
Resolution: Attended vessel and verified manufacturers mount was installed
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 8 December 2025 Resolved
All Vessels except non-selfpropelled vessels shall be provided with suitable steering apparatus. MIs observed accumulation of oil on steering line under helm. Clean impacted area and rectify leak. 46 CFR 182.30-5(a) (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2025
Resolved 9 January 2026
Resolution: Attended vessel and verified connections were snug, and oil accumulation was cleaned
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 8 December 2025 Resolved
Each hatch exposed to the weather must be watertight, except that the following hatches may be weathertight, each hatch on a vessel that operates only on protected waters. The gasket on the weathertight hatch going into the lazarette had become deteriorated. Replace to the satisfaction of MI. 46 CFR 171.124(a)(3)(Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2025
Resolved 9 January 2026
Resolution: Attended vessel and verified new gasket installed and would provide a proper seal
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 December 2025 Resolved
Except as provided otherwise in this subpart, all electrical equipment including motors, generators, controllers, distribution panels, etc., shall be be dripproof protected. MI found a missing cap in the switch panel located at the helm under a window allowing for water drip directly on exposed wires. Seal panel to the satisfaction of attending MI. 46 CFR 183.10-10(a)(Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2025
Resolved 9 January 2026
Resolution: Attended vessel and verified electrical box had a waterproof cap installed
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 8 December 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2025
Resolved 18 December 2025
Resolution: Vessel submitted MIS report to USCG and MIs conducted a DAPI audit with satisfactory results
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 November 2024 Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. Engine block heaters wiring installations are not a permanent installation. Port and starboard block heaters are wired with a flexible cord running through the port side ventilation intake for the engine room. Replace with permanent installation to the requirements of new electrical installations of subchapter T or remove flexible cords. 46 CFR 183.10-20 (a) (Old T)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 21 November 2024
Resolution: Removed extension cords until a permanent installation is completed.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 21 November 2024 Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arrestors. The vessels diesel fuel tank vent pipe was missing the flame screen. Provide evidence of newly fitted flame screen on the vent pipe to the satisfaction of the MI. 46 CFR 182.20-35(d) (OLD T)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 21 November 2024
Resolution: Installed new flame screen on vent piping.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 21 November 2024 Resolved
At each initial and subsequent inspection for certification and reinspection the firefighting equipment of all vessels shall be inspected and all deficiencies found shall be corrected. MI discovered electrical cord passing through a hole in the side of the starboard deck ventilation intake allowing egress of fixed fire system agent in the event of an emergency. Owner/Operator shall remove cord and provide permanent fixture to contain ventilation to the satisfaction of the MI. 46 CFR 182.20-35(d) (OLD T)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 21 November 2024
Resolution: Cords were removed during the inspection and hole was properly sealed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 November 2022 Resolved
Pre-engineered fixed gas fire extinguishing system must be installed in accordance with the manufactures instructions. Vessel owner reported an issue with their Fire Boy and replacement parts are experiencing a shipment delay. Provide an extra 40-B:C in the vicinity of the machinery space exit while Fire Boy is decommissioned. Once parts are received for the Fire Boy, the Marine Inspector will attend to commission the Pre engineered fire extinguishing system.
Action required: 705 - Other - as specified
Resolved 4 January 2023
Resolution: Vessel received parts and installed new Fire Boy equipment. Satisfactorily tested in presence of MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 November 2021 Resolved
46CFR16.401(b) EAP training program: An EAP training program must be conducted for the employer’s crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer's supervisory personnel. Supervisory personnel must receive at least 60 minutes of training.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 23 December 2021
Resolution: verified training and certs
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 November 2021 Resolved
47CFR 80.59(a)(2) 46CFR184.502 A certification that the ship has passed an inspection must be entered into the ship’s log by the technician. An inspection of the bridge-to-bridge radio stations on board vessels subject to the Vessel Bridge-to-Bridge Radiotelephone Act must be conducted by the same FCC-licensed technician. Provide an FCC safety radio telephony certificate that has been issued to the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 23 December 2021
Resolution: verified cert
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 30 November 2021 Resolved
47CFR80.905 46CFR184.502 Vessels operated solely within 20 nautical miles of th eland must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of 47CFR80.1101(c). Vessel does not have VHF/DSC radio with MMSI number programmed with position input.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 23 December 2021
Resolution: verified mssi and position
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 November 2021 Resolved
46CFR180.71 A number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. Each life jacket must be approved in accordance with either 160.002, 160.005, 160.055. Each life jacket must be marked IAW 46CFR185.604(b). Provide 02 child sized life jackets labeled in accorance with CFR.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 23 December 2021
Resolution: verified and inspected 02 child life jackets
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 November 2021 Resolved
46CFR185.726(e) Each floating waterlight must be approved IAW 46CFR161.010 in subchapter Q of this chapter. Replace battery in life buoy floating waterlight with battery approved by the light manufacturer. Replace battery in life buoy floating water light with approved replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 23 December 2021
Resolution: verified and inspected water light operations and battery
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 November 2021 Resolved
46CFR181.610 A vessel not required to have a power driven fire pump must have atleast three 2.5 gallon buckets with an attached lanyard. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Provide 3 fire buckets of 2.5 gallons, with attached lanyard sufficient to use the bucket as intended. Labeled properly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 23 December 2021
Resolution: verified and inspected 03 fire buckets
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 November 2021 Resolved
46CFR182.520(a) A vessel must be provided with bilge pumps IAW Table 182.520(a). Provide a fixed power bilge pump that has sufficient lift and head characteristics to discharge at least 10 gallons per minute.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 23 December 2021
Resolution: op tested new bigle pump
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 November 2021 Resolved
46CFR182.430 The design of all exhaust systems must ensure minimum risk of injury to personnel. Protection must be provided in compliance with 177.970 of this chapter at such locations where persons or equipment might come in contact with an exhaust pipe. Exhaust gas must not leak from the piping or any connections. Repair exhaust leak and replace damaged exhaust lagging.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 23 December 2021
Resolution: verified proper repair
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 April 2019 Resolved
The employer shall provide an Employee Assistance Program to all crewmembers [name withheld] must include education and training for crewmembers. Provide education information/displays outlined in 46 CFR 16.401(a) and training program information outined in 16.401(b).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2019
Resolved 29 May 2019
Resolution: EAP information was posted.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 April 2019 Resolved
In port lazarette, stiffeners were missing from previous side shell insert. Repair to original scantlings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2019
Resolved 29 May 2019
Resolution: Scantling were returned to original scantlings.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 22 April 2019 Resolved
Penetrations in watertight bulkheads must have means to make them watertight. Plug empty wire run bulkhead between laz and engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2019
Resolved 29 May 2019
Resolution: Penetrations had been filled, making them watertight.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 22 April 2019 Resolved
Each hatch exposed to the weather must be weathertight if the vessel operates only on protected waters. Replace gasket on engine room hatch to make weathertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2019
Resolved 29 May 2019
Resolution: New gaskets were installed on both engine room hatches.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 April 2019 Resolved
Portable extinguishers must be inspected and maintained IAW NFPA 10. The operator must provide satisfactory evidence of the required servicing to the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2019
Resolved 29 May 2019
Resolution: Fire extinguishers were serviced in May 2019.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 24 July 2018 Resolved
The master and crew shall be familiar with the content of the emergency instructions, which shall be posted on board. The vessel does not have emergency instructions posted. Post emergency instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2018
Resolved 7 August 2018
Resolution: Vessel provided emergency instructions.
Construction/Loadline › Hull › Side Shell
Issued 23 February 2016 Resolved
Crop and renew aft stbd quarter from transom fwd to 6" past first frams, vertically from upper rub rail to chine.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 March 2016
Resolved 10 March 2016
Construction/Loadline › Hull › Side Shell
Issued 23 February 2016 Resolved
SH03: Crop and renew (02) stbd midship side hull holes, with 18" x 18" section centered on frames.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 March 2016
Resolved 10 March 2016
Construction/Loadline › Hull › Weld
Issued 23 February 2016 Resolved
SH04: Grind and weld vertical stem weld.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 March 2016
Resolved 10 March 2016
Construction/Loadline › Hull › Side Shell
Issued 23 February 2016 Resolved
SH05: Crop and renew aft port quarter from transom fwd to to 6" past first frams, vertically from the lower rubrail to chine.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 March 2016
Resolved 10 March 2016
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 23 February 2016 Resolved
SH06:Crop and renew both main engine exhaust piping thru aft e/r bulkhead to encompass existing 18" x 18" plate inserts.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 22 March 2016
Resolved 10 March 2016
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 10 February 2016 Resolved
Provide proper operation of emergency fuel shut off valve.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2016
Resolved 10 February 2016
Resolution: demonstrated operation of valave
Construction/Loadline › Structures › Transverse Bulkhead
Issued 10 February 2016 Resolved
Repair engine room aft bulkhead at exhaust manifolds to make watertight
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 14 July 2017
Resolution: MI team confirmed repairs during annual inspection.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 10 February 2016 Resolved
Remove excess oil from bilges in engine room and steering compartment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2016
Resolved 10 February 2016
Resolution: Both compartments were cleaned out
Documentation › Logs/Records › Logbook (official)
Issued 10 February 2016 Resolved
Provide logs for drills and maintenance.
Action required: 705 - Other - as specified
Due 17 February 2016
Resolved 10 February 2016
Resolution: Vessel has created a system for logging drills/mainenance
Documentation › Logs/Records › Drug Test Records
Issued 10 February 2016 Resolved
Provide DAPI documentation and enrollment IAW audit form provided.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 February 2016
Resolved 2 March 2016
Resolution: Provided proper documentation.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 February 2016 Resolved
Receive annual inspection credit prior to carrying passengers
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2016
Resolved 10 February 2016
Resolution: Completed annual insoection.
Documentation › Logs/Records › Logbook (official)
Issued 10 February 2016 Resolved
Provide means to log passenger count for each voyage.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 February 2016
Resolved 10 February 2016
Resolution: Vessel created log to track passenger counts.