Documentation record
Registered dimensions (L × B × D)98.9 ft × 22.1 ft × 7.4 ft
Registered tonnagegross 93 / net 63
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEUVILLE BOAT WORKS INC · NEW IBERIA, LA, UNITED STATES · built 1980
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCOPPER HARBOR, MI
Endorsements, as the file codes themcw_un
DocumentationValid · issued 14 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 17
28 April 2026
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8357078
21 October 2025
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8256501
14 May 2025
COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8121384
20 November 2024
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8039805
23 May 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7921382
14 September 2023
Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7791470
28 June 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7723736
6 September 2022
Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7569339
5 September 2022
Damage Survey
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7551930
29 June 2022
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7522342
14 May 2021
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7199444
7 May 2020
Examination of Repairs · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6949985
24 September 2019
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6827440
18 July 2018
Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6485570
10 August 2017
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6236271
20 June 2017
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6181453
29 June 2016
Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 5921672
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 June 2023
Resolved
Discovered multiple locations in the fixed bilge system piping that had experienced leaks due to wastage and were repaired with sections of flexible hose. Make permanent repairs to the fixed bilge system piping by cropping and renewing (as original) these failed sections of pipe. Upon completion these repairs shall be subjected to a dye-penetrant test and operationally hydro tested. Submit photos and test results to MSU Duluth for evaluation.
Action required: 705 - Other - as specified
Due 28 September 2023
Resolved 14 September 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 September 2022
Resolved
Vessel owner reported failure of the turbo-charger blower driveshaft (inner-cam assembly) on the SME, resulting in loss of the SME and a reduction in maneuverability (note: vessel has 3 main engines). Repairs to the SME must be completed to the satisfaction of a USCG Marine Inspector. Until repairs are completed vessel may continue routine operations as long as the weather and seastate conditions remain calm. Vessel Captain shall assess weather forecast prior to every underway trip and suspend operations if forecast meets/exceeds the criteria of a small craft advisory for the vessel's operational area. Notify MSU Duluth of any trip cancellations or changes in operational parameters.
Action required: 705 - Other - as specified
Due 5 October 2022
Resolved 26 June 2023
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 5 September 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 5 October 2022
Resolved 26 June 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 May 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2021
Resolved 11 August 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 May 2021
Resolved
PROVIDE DOCUMENTATION FOR SUPERVISOR DRUG AWARENESS TRAINING.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2021
Resolved 11 August 2022
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 14 May 2021
Resolved
COMPLETE WELDING OF THE GALLEY DECK PANELS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2021
Resolved 11 August 2022
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 14 May 2021
Resolved
REPLACE WOODEN RAILINGS ON 01 DECK WITH ALUMINUM RAILINGS IN-KIND WITH EXISTING RAILS.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2021
Resolved 11 August 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 May 2021
Resolved
REPAIR PORT ENGINE STARTER.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2021
Resolved 14 May 2021
Resolution: Corrected by replacing pneumatic starter vanes.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 September 2019
Resolved
The raw water intake hose (outer covering) on the starboard main engine is deteriorated beyond serviceability. Replace hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2019
Resolved 7 May 2020
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 24 September 2019
Resolved
The vessel's 406 MHz EPIRB indicated a battery expiration date of 03/2018. Limit operations to within 3 miles from coastline; or, provide EPIRB, with satisfactory battery, currently registered with NOAA for this vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2019
Resolved 26 September 2019
Resolution: Vessel [name withheld] provided invoice for new EPIRB with satisfactory battery, and current NOAA registration documentation.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 July 2018
Resolved
Repair the small fuel leak at the starboard SSDG supply line.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 18 July 2018
Resolved 18 July 2018
Resolution: Fitting tightened.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 July 2018
Resolved
Repair the small fuel leak at the outboard return valve on the starboard fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 July 2018
Resolved 18 July 2018
Resolution: Valve bonnet tightened.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 28 June 2017
Resolved
Replace missing blanks in the panel behind the starboard generator.
Action required: 705 - Other - as specified
Due 26 July 2017
Resolved 28 June 2017
Resolution: Blanks installed prior to completion of inspection.
Electrical › Electric Generation Source (service) › Panelboard
Issued 28 June 2017
Resolved
Repair or replace the volt meter for the port genset.
Action required: 705 - Other - as specified
Due 26 July 2017
Resolved 7 August 2017
Resolution: New voltmeter installed.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 28 June 2017
Resolved
Repair or replace the inoperative relief valve on the port air receiver.
Action required: 705 - Other - as specified
Due 26 July 2017
Resolved 7 August 2017
Resolution: New relief valve installed.
Communications › Radio Communications › VHF Radiotelephone
Issued 28 June 2017
Resolved
Program VHF-FM radio with MMSI number.
Action required: 705 - Other - as specified
Due 26 July 2017
Resolved 10 August 2017
Resolution: MMSI programmed into radio.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 June 2016
Resolved
Ring lifebuoy lifeline and waterlight line are sun damaged. Replace lines.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2016
Resolved 20 June 2017
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 29 June 2016
Resolved
No senior deckhand designated as required on COI. Designate senior deckhands after completion of required training & experience outline in NVIC 1-91.
Action required: 705 - Other - as specified
Due 29 July 2016
Resolved 20 June 2017
Lifesaving › Inflatable Liferafts › Servicing
Issued 29 June 2016
Resolved
Liferaft inspection reconrd not available for review. Provide record of liferaft inspection & maintenance to MI.
Action required: 705 - Other - as specified
Due 29 July 2016
Resolved 20 June 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 June 2016
Resolved
Stern light not operable. Replace stern light prior to nighttime or restricted visibility operations.
Action required: 705 - Other - as specified
Due 29 July 2016
Resolved 20 June 2017
Engineering › Bilge Water Management System › Piping
Issued 29 June 2016
Resolved
Repair cracked suction piping for bilge suction to forepeak space. Damage located in #2 space below forward passenger cabin area. Alternative method: Electric pump onboard able to pump out space from main deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 20 June 2017