Records from 1981 to 1992. Most recent: inspection, 2 October 1992.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
2 October 1992
Administrative
Administrative · Commandant (CG-INV-3) · Activity 958982
12 August 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1342951
6 July 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1340503
8 June 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 902124
18 April 1988
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1344242
2 July 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016628
31 March 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1018992
24 March 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1007561
8 April 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1001499
16 December 1985
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1293832
22 February 1985
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1304766
5 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280299
18 May 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 968668
10 March 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1271548
5 October 1981
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 964846
23 September 1981
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 968295
23 September 1981
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1275428
Lifesaving
Issued 18 April 1988
Resolved
PRIOR TO REMAINNING AND/OR GETTING UNDERWAY, HAVE ON BOARD VESSEL FOR MODU AND BOTH LIFEBOATS, CURRENT APPROVED PYROTECHNICS. IF COAST GUARD APPROVEDEQUIPMENT IS NOT AVAILABLE, REPLACE IN KIND WITH BRAZILIAN EQUIPMENT.
Condition: Unknown
Due 18 April 1988
Resolved 18 April 1988
Lifesaving
Issued 18 April 1988
Resolved
PROVIDE ON BOARD, 1500' AUX LINE FOR LINE THROWING EQUIPMENT AS REQUIRED BY 46 CFR 108.517.
Condition: Unknown
Due 18 April 1988
Resolved 18 April 1988
Engineering
Issued 18 April 1988
Resolved
PROVIDE TWO 40 PSI RELIEF VALVES, ASME APPROVED, WITH HAND RELIEVING GEAR FOR REPLACEMENT OF THE TWO INOPERATIVE ONES ON BULK TANKS.
Condition: Unknown
Due 18 April 1988
Resolved 18 April 1988
Engineering
Issued 18 April 1988
Resolved
PROVIDE PROPER HINGE AND CLOSURE DEVICES FOR MANWAY ACCESS TO #1 CEMENT TANK.
Condition: Unknown
Due 18 April 1988
Resolved 18 April 1988
Electrical
Issued 18 April 1988
Resolved
REPLACE ALL REINABLE LINK FUSES ON VESSEL WITH SINGLE USE TYPE. THESE WERENOTED IN THE GENERAL ALARM FUSE BOX AND THE SCR PANEK.
Condition: Unknown
Due 18 April 1988
Resolved 18 April 1988
Electrical
Issued 18 April 1988
Resolved
REPAIR INOPERATIVE REVERSE POWER RELAY FOR #1 PANEL.
Condition: Unknown
Due 18 April 1988
Resolved 18 April 1988
Fire Fighting
Issued 18 April 1988
Resolved
REPLACE FIRE STATION IN ENGINE ROOM WHICH PRESENTLY HAS NON STANDARD THREADAND HOSE. PROVIDE ON BOARD, ONE ADDITIONAL APPROVED HOSE TO OUTFIT ALL FOURTEEN FIRE STATIONS.
Condition: Unknown
Due 18 April 1988
Resolved 18 April 1988
Deck/Cargo
Issued 18 April 1988
Resolved
PROVIDE EVIDENCE OF QUADRENNIAL LOAD TEST AND/OR MAKE ARRANGEMENTS. TO HAVE TEST PERFORMED AND PROVIDE EVIDENCE OF SATISFACTORY TEST.
Condition: Unknown
Due 18 April 1988
Resolved 18 April 1988
Accommodation/Occupational Safety
Issued 24 March 1987
Resolved
REPAIR VENTILLATION DUCT LOCATED ON PORT SIDE OF EACH ROOM AT MUD PIT AREA BULKHEAD.
Condition: Unknown
Due 24 March 1987
Resolved 24 March 1987
Deck/Cargo
Issued 24 March 1987
Resolved
PROVIDE LIMIT SAFETY FOR CRANE BOOMS TO PREVENT TUBE LOCKING READACHE.
Condition: Unknown
Due 24 March 1987
Resolved 24 March 1987
Unknown
Issued 16 December 1985
Resolved
PROVIDE A COAST GUARD STAMPED APPROVED COPY OF THE FIRE CONTROL PLAN ON BOARD RIG. REF NVC-4-78 AND 46 CFR 107.305(VV).
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Electrical
Issued 16 December 1985
Resolved
MAKE OPERABLE THE EMERGENCY BATTERY LIGHTS IN MACHINERY SPACES. NVC-4-78 AND 46 CFR 112.15.1.
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Electrical
Issued 16 December 1985
Resolved
MAKE OPERABLE THE REVERSE POWER TRIP DEVICE ON #3 GENERATOR. NVC-4-78 AND 46 CFR 111.65.1(C).
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Unknown
Issued 16 December 1985
Resolved
MAKE OPERABLE THE HIGH TEMP ALARM AND ROTATING ALARM LIGHT ON THE #1 MAIN GENERATOR EMD. REF NVC-4-78 & 46 CFR 111.05.10.
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Electrical
Issued 16 December 1985
Resolved
MAKE AVAILABLE FOR INSPECTION THE LOWER 50 FEET OF EACH LEG, LEG CAN AND LEG TO CAN CONNECTION. INSPECTION IS TO BE CONDUCTED IN ACCORDANCE WITH APPROVED PROPOSAL AND IN THE PRESENCE OF A COAST GUARD INSPECTOR. 46 CFR 107.267.
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Electrical
Issued 16 December 1985
Resolved
MAKE OPERABLE THE REMOTE STOP SWITCH FOR #1 FUEL PUMP AND MCC #1 BUS A VENTILATOR. REF NVC-4-78 AND 46 CFR 111.80.10.
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Electrical
Issued 16 December 1985
Resolved
MAKE BULKHEAD BETWEEN MUD PUMP ROOM AND SCR ROOM, MUD PUMP ROOM AND GENERATOR ROOM IN WAY OF ELECTRIC CABLE WIREWAYS, WATERTIGHT. REF NVC-4-78.
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Construction/Loadline
Issued 16 December 1985
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Lifesaving
Issued 16 December 1985
Resolved
INSTALL METAL TIES ON ELECTRIC CABLE WIREWAYS LOCATED IN WAY OF OVERHEAD IN GENERATOR ROOM. REF NVC-4-78 AND 46 CFR 111.60.25.
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Unknown
Issued 5 March 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL MARLIN NO. 14 DN612722.
Condition: Unknown
Due 5 March 1984
Resolved 5 March 1984
Unknown
Issued 5 March 1984
Resolved
RESTORE THE F/O FILL CONNECTION COUPLINGS ABOVE THE EXISTING FIXED CON- TAINMENT 33 CFR 155.320.
Condition: Unknown
Due 5 March 1984
Resolved 5 March 1984
Unknown
Issued 5 March 1984
Resolved
PROVIDE FIXED F/O CONTAINMENT UNDER THE DAY TANK VENT 33 CFR 155.320.
Condition: Unknown
Due 5 March 1984
Resolved 5 March 1984
Electrical
Issued 5 March 1984
Resolved
REPAIR THE EMERGENCY GENERATOR AUTOMATIC STARTING SYSTEM NAVIC 4-78 D (1) (B).
Condition: Unknown
Due 5 March 1984
Resolved 5 March 1984
Construction/Loadline
Issued 23 September 1981
Resolved
10'X12' SET IN, IN WAY OF #8 STBD VOID TANK WITH UPSET FRAME
Condition: Unknown
Due 23 September 1981
Resolved 23 September 1981
Documentation
Issued 23 September 1981
Resolved
EXPIRED PROVISIONAL LOADLINE CERTIFICATE
Condition: Unknown
Due 31 March 1982
Resolved 23 September 1981