MAURY USCG vessel records Sign in
← All vessels

SPARTAN RIG 303

SPARTAN RIG 303 is a 1974 mobile offshore drilling unit. The Coast Guard has recorded 100 inspections since 1982, most recently in March 2021, along with 128 deficiencies and 2 casualty investigations between 2012 and 2014.

Records from 1982 to 2021. Most recent: inspection, 18 March 2021.

Built
1974
Last inspected
18 March 2021
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8751825 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDC4839
Flag
UNITED STATES
—
Maury page id
psix-51894

Inspections, by type

…with no type recorded23
Years with a record 32 calendar years (1982–2021)
The 100 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)210.1 ft × 170.1 ft × 27.5 ft
Registered tonnagegross 4,980 / net 4,561
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBETHLEHEM STEEL · BEAUMONT, TX, UNITED STATES · built 1974
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itMobile Offshore Drilling Unit
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4980 - Regulatory (Subpart C or D), Gross Ton
4561 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ATLAS TIDE Offshore Supply Vessel · MISLE 54790 · 19 May 1996 · activity 145254

Inspection history · 100

18 March 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7158520
8 October 2015 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5882408
31 July 2015 Annual Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5194766
27 August 2014 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4967669
21 May 2014 Periodic Inspection · Welding Related Inspections Qualification Testing · Examination of Repairs · MTSA Verification · Administrative Inspection · Plan Review (Other than "T") · Deficiency Check · Hull Examination · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4864134
26 July 2012 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4391063
10 July 2012 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4374063
22 May 2012 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4318490
1 January 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4218571
31 December 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4218565
20 February 2011 Deficiency Check · Underwater Inspection in lieu of Drydock
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3957231
20 January 2011 Underwater Inspection in lieu of Drydock · Examination of Repairs · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3929893
26 March 2010 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3703673
19 March 2010 Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3695945
4 December 2009 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3644997
13 February 2009 Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3417242
3 September 2008 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3317183
9 May 2008 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3202510
23 April 2008 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3190457
4 April 2008 Deficiency Check · Periodic Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3177719
29 October 2007 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3089152
9 April 2007 Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2886519
14 March 2006 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2602461
7 February 2006 Hull Examination · COI Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2571838
22 April 2004 Periodic Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2040869
29 October 2002 Annual Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1693096
27 February 2002 Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1487869
11 January 2001 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1395645
8 July 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 820138
26 May 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1049501
22 May 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 818628
1 February 2000 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1441610
13 January 2000 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1403283
6 January 2000 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1444259
18 October 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 770413
28 September 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 209382
8 February 1999 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1127597
5 February 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 791845
15 January 1999 Deficiency Check · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1415114
16 October 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 802155
13 July 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1129250
10 July 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1128217
1 May 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1125483
27 April 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1124681
24 March 1998 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1408073
17 March 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1107685
11 February 1998 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 776688
19 November 1997 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1107743
22 October 1997 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 778153
18 September 1997 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409759
26 August 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 784708
22 July 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 782934
30 April 1997 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1102409
9 April 1997 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1103064
20 March 1997 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1091506
25 January 1997 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1425859
13 January 1997 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 786244
19 May 1996 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 145254
29 March 1996 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1437086
12 December 1995 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1192508
19 June 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 878833
17 June 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1400186
8 May 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1350470
21 March 1995 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 877741
31 January 1995 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1398206
26 January 1995 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1367275
18 March 1994 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 855489
15 March 1994 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1165597
8 June 1993 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1142652
1 February 1993 Hull Examination · COI Inspection · Examination of Repairs
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 827324
2 June 1992 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1257415
28 April 1992 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1387252
27 March 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1216371
19 October 1990 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1216509
7 January 1990 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1242964
4 December 1989 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 903942
17 November 1989 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 905115
27 October 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1206336
27 October 1989 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1206337
26 October 1989 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1195962
16 May 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1042212
16 May 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1216715
16 May 1989 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1216716
1 December 1988 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1340466
17 November 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1204380
26 October 1988 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1201387
11 December 1987 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1008117
13 October 1987 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1024625
25 March 1987 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1327333
3 March 1987 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1005370
24 October 1986 COI Inspection · Credit Drydock
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1011069
17 April 1986 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1306425
4 December 1985 Examination of Repairs
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 986355
17 October 1985 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1300913
27 June 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1291632
15 October 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1282868
20 April 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 973443
19 March 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1280042
17 November 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 971047
13 October 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 963913

Deficiency record · 128

Electrical › Lighting (service) › Lighting Fixture
Issued 31 July 2015 Resolved
Vessel had fixtures in vicinity of shakers. Ensure fixtures are classed appropriately or removed from hazardous zone.
Action required: 705 - Other - as specified
Due 14 August 2015
Resolved 1 August 2015
Resolution: Received email from PIC with accompanying pictures showing that all hazardous location electrical appliances had been corrected.
Stability › Watertight Integrity › Coaming
Issued 31 July 2015 Resolved
Vessel had multi cable transist on top of leg tower #2 that had open communication to area below. Ensure MCT is installed as per manufacture instructions.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 December 2015
Resolved 16 December 2015
Resolution: Received email with pictures from Captain stating that the MCT cbale transit had been properly repaired.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 30 June 2014 Resolved
Repair/replace the fire damper in the aft bulkhead of the generator room.
Action required: 705 - Other - as specified
Due 30 July 2014
Resolved 7 July 2014
Resolution: Fire damper replaced.
Construction/Loadline › Hull › Bottom Plating
Issued 16 February 2011 Resolved
Complete Phase II of the SEILOD inspection at the next rig movement.
Action required: 705 - Other - as specified
Due 16 March 2011
Resolved 18 March 2011
Resolution: Reviewed Class Society (American Bureau of Shipping) Survey Report detailing completed Dry-Docking Survey - UWILD satisfying the deficiency requiring Phase II SEILODD Examination.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 19 March 2010 Resolved
Current method to close mushroom vents to main engine space requires use of portable ladder or crane. Provide safe effective means to close ventilation.
Action required: 705 - Other - as specified
Due 5 April 2010
Resolved 1 April 2010
Resolution: OIM confirmed by statement outstanding deficiency corrected, A. Willett, MSU PA
Engineering › Fuel Oil Service System › Hose
Issued 19 March 2010 Resolved
Flexible fuel line on Testco generator on top of drilling house has flexible line exceeding 30 inches. Replace with approved piping IAW 46 CFR Subpart F.
Action required: 705 - Other - as specified
Due 5 April 2010
Resolved 1 April 2010
Resolution: OIM confirmed by statement outstanding deficiency corrected, A. Willett, MSU PA
Engineering › Fuel Oil Service System › Ventilation
Issued 19 March 2010 Resolved
Flame screens on 4S diesel tanks holed. Replace with approved flame screens.
Action required: 705 - Other - as specified
Due 19 March 2010
Resolved 1 April 2010
Resolution: OIM confirmed by statement outstanding deficiency corrected, A. Willett, MSU PA
Lifesaving › Launching Appliances › Winch
Issued 19 March 2010 Resolved
Limit switches for winch do not stop the number 1 lifeboat from contacting cradle. Service limit swtich to ensure lifeboat does not contact davit cradle.
Action required: 705 - Other - as specified
Due 5 April 2010
Resolved 1 April 2010
Resolution: OIM confirmed by statement outstanding deficiency corrected, A. Willett, MSU PA
Lifesaving › Lifeboat › Fire Protection (water spray system)
Issued 19 March 2010 Resolved
Water spray system for the number 1 lifeboat inoperable. Service to ensure proper operation.
Action required: 705 - Other - as specified
Due 5 April 2010
Resolved 1 April 2010
Resolution: OIM confirmed by statement outstanding deficiency corrected, A. Willett, MSU PA
Engineering › Fuel Oil Service System › Hose
Issued 19 March 2010 Resolved
Flexible fuel line for number 2 main engine exceeds 30 inches. Replace with approved piping IAW 46 CFR Subpart F.
Action required: 705 - Other - as specified
Due 5 April 2010
Resolved 1 April 2010
Resolution: OIM confirmed by statement outstanding deficiency corrected, A. Willett, MSU PA
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 19 March 2010 Resolved
Fire alarms for portable quarters is inoperable. Repair/service to ensure proper operation.
Action required: 705 - Other - as specified
Due 5 April 2010
Resolved 1 April 2010
Resolution: OIM confirmed by statement outstanding deficiency corrected, A. Willett, MSU PA
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 19 March 2010 Resolved
MCT devices(Rokblok) in mutilple locations ( portable quarters and barrel room/generator room) improperly installed. Service and install to meet manufactures requirements.
Action required: 705 - Other - as specified
Due 5 April 2010
Resolved 1 April 2010
Resolution: OIM confirmed by statement outstanding deficiency corrected, A. Willett, MSU PA
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 4 April 2008 Resolved
Provide proof of valid COFR.
Due 12 April 2008
Resolved 14 April 2008
Resolution: Received confirmation of insurance paperwork. Originial COFR will be on the next boat out to the rig (4/17).
Accommodation/Occupational Safety › Potable Water System › General
Issued 4 April 2008 Resolved
Install NSF approved piping for potable water system.
Due 11 May 2008
Resolved 14 April 2008
Resolution: Received invoice and picture of properly installed piping.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 4 April 2008 Resolved
Repair/replace RPM gauge on #2 MDE.
Due 18 April 2008
Resolved 14 April 2008
Resolution: Installed new gauge.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 4 April 2008 Resolved
Provide copy of emergency evacuation plan approval letter.
Due 18 April 2008
Resolved 28 April 2008
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 4 April 2008 Resolved
Remove extra rack in treatment room or update fire control plan. Rig can not carry more than 46 people until plan updated. Send copies (3) of updated plans to [name withheld].
Due 11 May 2008
Resolved 14 April 2008
Resolution: Removed extra rack.
Stability › Watertight Integrity › General
Issued 4 April 2008 Resolved
Service water tight door in pantry.
Due 18 April 2008
Resolved 14 April 2008
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 4 April 2008 Resolved
Install flame screen on diesel and fuel day tanks.
Due 18 April 2008
Resolved 14 April 2008
Deck/Cargo › Cargo Transfer (solid) › General
Issued 4 April 2008 Resolved
Provide copy of load test results for port crane.
Due 18 April 2008
Resolved 14 April 2008
Lifesaving › Launching Appliances
Issued 22 April 2004 Resolved
Provide report for lifeboat falls servicing and weight test. LEGACY COMPONENT DESC: Falls
Due 22 May 2004
Resolved 26 May 2004
Operations/Management › Drills/Instruction
Issued 22 April 2004 Resolved
Complete satisfactory fire & abandon ship drills prior to sailing. LEGACY COMPONENT DESC: Fire
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2004
Construction/Loadline › Hull
Issued 29 October 2002 Resolved
COMPLETE PHASE II OF SEILOD
Action required: 705 - Other - as specified
Due 30 December 2002
Resolved 29 October 2002
Operations/Management › Drills/Instruction › Abandon Ship
Issued 27 February 2002 Resolved
CONDUCT A FIRE AND BOAT DRILL IN THE PRESENCE OF A CG MARINE INSPECTOR. LEGACY COMPONENT DESC: Fire & Boat
Due 30 December 2002
Resolved 10 February 2006
Resolution: Conducted fire and abandon ship drills. Both drills satisfactory.
Deck/Cargo
Issued 27 February 2002 Resolved
PROVIDE COPY OF CLASS SOCIETY STATEMENT OF FACT FOR CRANES. LEGACY COMPONENT DESC: Crane
Condition: Unknown
Due 27 March 2002
Resolved 29 October 2002
Resolution: Reviewed ABS statement of fact.
Construction/Loadline
Issued 6 January 2000 Resolved
CONDUCT PHASE II OF SEILODD INSPECTION INCLUDING SWIM-BY WITH DIVERS; PROVIDE VIDEO TO MSO NEW ORLEANS.
Condition: Unknown
Due 6 January 2000
Resolved 6 January 2000
Unknown
Issued 15 January 1999 Resolved
MAKE REPAIRS TO THE SALT WATER LINES OVER THE GREY WATER TANK.
Condition: Unknown
Due 19 January 1999
Resolved 19 January 1999
Lifesaving
Issued 15 January 1999 Resolved
INSTALL/PROVE PROPER OPERATION OF E-LIGHT FOR THE GENERATOR ROOM.
Condition: Unknown
Due 14 February 1999
Resolved 8 February 1999
Fire Fighting
Issued 15 January 1999 Resolved
MOUNT THE #46 FIRE EXT OFF THE DECK.
Condition: Unknown
Due 19 January 1999
Resolved 19 January 1999
Lifesaving
Issued 15 January 1999 Resolved
PROVE PROPER OPERATION OF THE P/V VALVES FOR THE #1 & #2 CEMENT TANKS.
Condition: Unknown
Due 19 January 1999
Resolved 19 January 1999
Lifesaving
Issued 15 January 1999 Resolved
PROVE PROPER OPERATION OF THE MUD PITS VENT ALARM.
Condition: Unknown
Due 19 January 1999
Resolved 19 January 1999
Lifesaving
Issued 15 January 1999 Resolved
REPLACE EYEWASH BOTTLE STARBOARD SIDE DRILL FLOOR, AFT.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Lifesaving
Issued 15 January 1999 Resolved
CHANGE OUT THE RED WITH YELLOW LIGHTS ON THE HELO DECK STAR SIDE.
Condition: Unknown
Due 14 February 1999
Resolved 8 February 1999
Electrical
Issued 15 January 1999 Resolved
PROVE PROPER OPERATION OF E-LIGHT BY INBOARD MDE PANEL.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Lifesaving
Issued 15 January 1999 Resolved
LABEL ALL GENERAL ALARM BELLS.
Condition: Unknown
Due 19 January 1999
Resolved 19 January 1999
Unknown
Issued 15 January 1999 Resolved
LABEL THE CONTROLS TO BOTH CRANES.
Condition: Unknown
Due 19 January 1999
Resolved 19 January 1999
Electrical
Issued 15 January 1999 Resolved
REPAIR THE BREAKER BOX IN THE GALLEY.
Condition: Unknown
Due 19 January 1999
Resolved 19 January 1999
Fire Fighting
Issued 15 January 1999 Resolved
REPLACE THE FIRE HOSE AT STA BY THE SHAKER.
Condition: Unknown
Due 19 January 1999
Resolved 19 January 1999
Fire Fighting
Issued 15 January 1999 Resolved
LABEL ALL FIRE HOSE STATIONS.
Condition: Unknown
Due 19 January 1999
Resolved 19 January 1999
Construction/Loadline
Issued 15 January 1999 Resolved
PROVE PROPER OPERATION OF SELF CLOSING DOOR FROM SHAKER TO STARBOARD THRUSTER ROOM.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Fire Fighting
Issued 15 January 1999 Resolved
MARK FIRE STATION STARBOARD SIDE UNDER SHKER HOUSE/MUD PITS.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Fire Fighting
Issued 15 January 1999 Resolved
MARK GENERAL ALARM BELL STARBOARD SIDE IN WAY OF #2 JACK HOUSE.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Electrical
Issued 15 January 1999 Resolved
SHORE UP LOOSE BATTERIES IN GENERAL ALARM/NAV LIGHT BATTERY BOXES.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Construction/Loadline
Issued 15 January 1999 Resolved
PROVE PROPER OPERATION OF #3 CEMENT P/V VALVE.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Construction/Loadline
Issued 15 January 1999 Resolved
PROVIDE RING TO PULL HAND DEVICE FOR STANDBY AIR RECEIVER P/V VALVE IN ROUSTABOUT LOCKER.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Fire Fighting
Issued 24 March 1998 Resolved
SECURE CO2 BOTTLE IN PAINT LOCKER
Condition: Unknown
Due 24 March 1998
Resolved 30 March 1998
Fire Fighting
Issued 24 March 1998 Resolved
REPLACE HOSE FOR STATION #5
Condition: Unknown
Due 24 March 1998
Resolved 30 March 1998
Documentation
Issued 24 March 1998 Resolved
PROVIDE CURRENT ABS CRANE CERTIFICATES (ANNUALS/LOAD TESTS) COPIES TO [name withheld], TX
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Fire Fighting
Issued 24 March 1998 Resolved
REPLACE CO2 HOSE ON HOSE REEL IN THE GENERATOR ROOM.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Electrical
Issued 24 March 1998 Resolved
INSTALL PROPER BATTERY CHARGERS FOR EMERGENCY BATTERIES
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Lifesaving
Issued 24 March 1998 Resolved
REPAIR EYEWASH STATION IN THE SHAKER AREA AND PLACE CAPS ON EYEWASH STATIONS IN SHAKER AREA AND THE DRILL FLOOR
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Lifesaving
Issued 24 March 1998 Resolved
INSTALL APURGE SYSTEM ON THE TESCO PANEL ON THE DRILL FLOOR
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Fire Fighting
Issued 24 March 1998 Resolved
PROVIDE PROTECTIVE PANTS FOR FIRE FIGHTING ENSEMBLES
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Electrical
Issued 24 March 1998 Resolved
PROVIDE EMERGENCY LIGHTING FOR LIFE RAFT DAVIT STATION
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Fire Fighting
Issued 24 March 1998 Resolved
LABEL PAINT LOCKER CO2 PULL STATION AND ASSOCIATED VENTS TO BE CLOSED
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Construction/Loadline
Issued 24 March 1998 Resolved
PROVIDE PROPER GASKET FOR PORT FINGER VENT DUCT CLOSURE TO THRUSTER ROOM TOENSURE PROPER WATERTIGHT CLOSURE
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Documentation
Issued 24 March 1998 Resolved
PROVIDE CURRENT ENDORSEMENT FOR CERT OF DOCUMENTATION ON BOARD VSL
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Lifesaving
Issued 24 March 1998 Resolved
PROVIDE NEW SWITCH FOR MOTOR CONTROLLER IN WAY OF LIFEBOAT STATION #1.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Construction/Loadline
Issued 24 March 1998 Resolved
LABEL VENTS ON WEATHER DECKS
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Lifesaving
Issued 24 March 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Lifesaving
Issued 24 March 1998 Resolved
FOR L/B STATION #1 PROVIDE THE FOLLOWING EQUIP: 2 ORANGE SMOKES, LIFESAVINGSIGNALS TABLE, JACKNIFE, RECHARGED FIRE EXTINGUISHER, LIFEBOAT GUNWALE LADDER
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Lifesaving
Issued 24 March 1998 Resolved
FOR LIFEBOAT STATION #2 PROVIDE THE FOLLOWING EQUIP: 11 PARACHUTE FLARES, 1ORANGE SMOKE, LIFEBOAT GUNWALE LADDER.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Fire Fighting
Issued 24 March 1998 Resolved
INSTALL VALVE AT HOSE STATION #11
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Lifesaving
Issued 24 March 1998 Resolved
REPLACE RING BUOY STARBOARD SIDE FORWARD ADJACENT TO #2 LIFEBOAT
Condition: Unknown
Due 24 March 1998
Resolved 30 March 1998
Lifesaving
Issued 24 March 1998 Resolved
REPLACE WINDOW AT LIFEBOAT STATION #2
Condition: Unknown
Due 24 March 1998
Resolved 30 March 1998
Lifesaving
Issued 24 March 1998 Resolved
STENCIL GENERAL ALARM PORT SIDE ADJACENT TO P-TANK #1
Condition: Unknown
Due 24 March 1998
Resolved 30 March 1998
Accommodation/Occupational Safety
Issued 18 September 1997 Resolved
SUBMIT UT REPORTS FOR 3 BULK TANKS AND 2 AIR RECEIVERS (COMPRESSOR ROOM) TOOCMI MORGAN CITY.
Condition: Unknown
Due 18 September 1997
Resolved 18 September 1997
Construction/Loadline
Issued 18 September 1997 Resolved
VOID 12S: 1)RENEW 2 BROKEN STUDS FOR HATCH COVER, 2)WELD PERIMETER OF PIPE PENETRATIONS, INBOARD BKHD, 3)RENEW 2 BOTTOM STIFFENERS BETWEEN FRAMES 4 AND 5.
Condition: Unknown
Due 18 September 1997
Resolved 18 September 1997
Construction/Loadline
Issued 18 September 1997 Resolved
DESCALE, CLEAN, LUBE, AND REGASKET THROUGH-HULL CHECK VALVES. VERIFY PROPEROPERATION OF VALVES/REPLACE AS NECESSARY.
Condition: Unknown
Due 18 September 1997
Resolved 18 September 1997
Construction/Loadline
Issued 18 September 1997 Resolved
#3S S/W: GAUGE AND MAKE REPAIRS AS PER ABS REQUIREMENT.
Condition: Unknown
Due 18 September 1997
Resolved 18 September 1997
Construction/Loadline
Issued 18 September 1997 Resolved
11P: RENEW WASTED MANHOLE COAMING, MANHOLE COVER, AND DECK STIFFENERS ADJACENT TO MANHOLE COVER._x001C_
Condition: Unknown
Due 18 September 1997
Resolved 18 September 1997
Construction/Loadline
Issued 18 September 1997 Resolved
EXAMINE SEA CHEST VALVE TO SATISFACTION OF ATTENDING ABS SURVEYOR.
Condition: Unknown
Due 18 September 1997
Resolved 18 September 1997
Construction/Loadline
Issued 18 September 1997 Resolved
SUBMIT DIVING REPORTS AND VIDEO OF LEG-TO-MAT INSPECTIONS TO [name withheld].
Condition: Unknown
Due 18 September 1997
Resolved 18 September 1997
Construction/Loadline
Issued 18 September 1997 Resolved
12P: REPLACE BROKEN MANHOLE COVER STUDS, REPLACE MANHOLE COVER, CLEAN AND REINSPECT MANHOLE COAMING.
Condition: Unknown
Due 18 September 1997
Resolved 18 September 1997
Construction/Loadline
Issued 18 September 1997 Resolved
VOID 11S: WELD TWO INSERTS IN OVERHEAD FROM INSIDE OF TANK.
Condition: Unknown
Due 18 September 1997
Resolved 18 September 1997
Construction/Loadline
Issued 18 September 1997 Resolved
9P: GOUGE AND WELD 3RD OVERHEAD DECK ANGLE INBOARD OF SEVENTH BAY.
Condition: Unknown
Due 18 September 1997
Resolved 18 September 1997
Construction/Loadline
Issued 20 March 1997 Resolved
MAKE HULL AVAILABLE FOR EXAMINATION AT NEXT AVAILABLE DRYDOCK.
Condition: Unknown
Due 30 April 1997
Resolved 9 April 1997
Electrical
Issued 25 January 1997 Resolved
PROVE PROPER OPERATION OF AIR COMPRESSOR ROOM SUPPLY VENTILATION FAN.
Condition: Unknown
Due 25 January 1997
Resolved 25 January 1997
Documentation
Issued 25 January 1997 Resolved
AREA SPECIFIC EEP NOT ON BOARD VESSEL. SUBMIT PLAN TO MSO CORPUS FOR APPROVAL.
Condition: Unknown
Due 25 January 1997
Resolved 25 January 1997
Lifesaving
Issued 25 January 1997 Resolved
PROVIDE AND INSTALL REEFER ALARM FOR REEFER SPACE AND HAVE ALARM INDICATOR LOCATED IN A HIGH CAPACITY AREA.
Condition: Unknown
Due 25 January 1997
Resolved 25 January 1997
Unknown
Issued 25 January 1997 Resolved
STENCIL ALL CONTROLLERS FOR EQUIPMENT THEY OPERATE AND PROVIDE DIRECTORY INALL PANEL BOARDS.
Condition: Unknown
Due 25 January 1997
Resolved 25 January 1997
Lifesaving
Issued 29 March 1996 Resolved
REPAIR/REPLACE INBOARD LIMITING SWITCH ON #1 LIFEBOAT.
Condition: Unknown
Due 1 May 1996
Resolved 13 May 1996
Fire Fighting
Issued 29 March 1996 Resolved
INSTALL NEW HOSE AND HANDLE ON DRY CHEMICAL FIRE EXT STATION 41.
Condition: Unknown
Due 1 May 1996
Resolved 13 May 1996
Fire Fighting
Issued 29 March 1996 Resolved
REPAIR PINHOLE LEAK IN FIRE MAIN PIPING IN COMPRESSOR ROOM.
Condition: Unknown
Due 1 May 1996
Resolved 13 May 1996
Fire Fighting
Issued 29 March 1996 Resolved
TIGHTEN LOOSE PACKING GLAND ON FIRE/SALTWATER PUMP.
Condition: Unknown
Due 1 May 1996
Resolved 13 May 1996
Lifesaving
Issued 29 March 1996 Resolved
PROCURE 01 HATCHET AND LINE FOR EACH LIFEBOAT.
Condition: Unknown
Due 1 May 1996
Resolved 13 May 1996
Construction/Loadline
Issued 17 June 1995 Resolved
SUBMIT FINAL NDT REPORT TO [name withheld].
Condition: Unknown
Due 17 June 1995
Resolved 17 June 1995
Construction/Loadline
Issued 31 January 1995 Resolved
MAKE READY FOR INSPECTION MUD-PIT DUMP VALVES PRIOR TO NEXT RIG MOVE NO LATER THAN 08AUG95.
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995
Construction/Loadline
Issued 31 January 1995 Resolved
CONDUCT LOWER HULL PORTION OF SEILOD (NDT OF CRITICAL CONNECTIONS & SWIM-BYOF MAT) PRIOR TO NEXT RIG MOVE NO LATER THAN 08AUG95.
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995
Accommodation/Occupational Safety
Issued 26 January 1995 Resolved
MAKE READY FOR INTERNAL INSPECTION RIG FLOOR AIR RECEIVER & TEST RELIEF VALVE.
Condition: Unknown
Due 26 January 1995
Resolved 26 January 1995
Construction/Loadline
Issued 26 January 1995 Resolved
MAKE READY FOR INSPECTION MUD-PIT DUMP VALVES PRIOR TO NEXT RIG MOVE NO LATER THAN 08AUG95.
Condition: Unknown
Due 14 February 1995
Resolved 14 February 1995
Construction/Loadline
Issued 26 January 1995 Resolved
CONDUCT LOWER HULL PORTION OF SEILOD (NDT OF CRITICAL CONNECTIONS & SWIM-BYOF MAT) PRIOR TO NEXT RIG MOVE NO LATER THAN 08AUG95.
Condition: Unknown
Due 14 February 1995
Resolved 14 February 1995
Lifesaving
Issued 15 March 1994 Resolved
PROVIDE PARACHUTE FLARES (12) FOR MODU RIG.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Lifesaving
Issued 15 March 1994 Resolved
RENEW SMOKE FLARES FOR BOTH LIFEBOATS (TOTAL 4 SMOKE FLARES)._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Unknown
Issued 15 March 1994 Resolved
PROVIDE APPROVED FITTING ON LOWER END OF #1 MUD PUMP DIESEL GOVENOR OIL SUPPLY LINE.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Lifesaving
Issued 15 March 1994 Resolved
INSTALL LIGHTS ON ALL PFD'S (19) REQUIRING NEW LIGHTS.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Unknown
Issued 15 March 1994 Resolved
RENEW WASTED FLEX OIL SUPPLY LINE TO TURBO #2 DRILL FLOOR ENGINE.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Construction/Loadline
Issued 15 March 1994 Resolved
TIGHTEN/ADJUST LOOSE AND FLOPPY WATER TIGHT DOOR HANDLES.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Unknown
Issued 15 March 1994 Resolved
RENEW CHAFFED FLEX FUEL LINE ON #2 MUD PUMP DIESEL FUEL PRIMING PUMP.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Unknown
Issued 15 March 1994 Resolved
REPAIR FUEL FILTER HOUSING LEAK AROUND TRANSFER SHAFT HANDLE #1 GENERATOR.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Unknown
Issued 15 March 1994 Resolved
RENEW WASTED FUEL PRESSURE FLEX HOSE GAUGE ON #1 GENERATOR.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Unknown
Issued 15 March 1994 Resolved
RENEW WASTED FLEX FUEL LINE TO PRESSURE REGULATOR ON #1 GENERATOR.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Unknown
Issued 15 March 1994 Resolved
STENCIL SALT WATER VALVES IN MUD PUMP ROOM.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Construction/Loadline
Issued 8 June 1993 Resolved
AT THE NEXT HULL EXAMINATION (SEILOD), RE-EXAMINE THE 0530 POSITION OF THE STARBOARD LEG TO WRAPPER TO MONITOR THE MP-NDT INDICATION OBSERVED DURING THE 01FEB93 SEILOD.
Condition: Unknown
Due 8 June 1993
Resolved 8 June 1993
Construction/Loadline
Issued 8 June 1993 Resolved
RE-EXAMINE DAMAGED AREA AND TEMPORARY REPAIRS TO PORT BOW FLOODED TANK TOP/FRONT EDGE.
Condition: Unknown
Due 8 June 1993
Resolved 8 June 1993
Construction/Loadline
Issued 1 February 1993 Resolved
PROVIDE A PROPOSAL TO [name withheld], TX FOR MAKING PERNANENT REPAIRSTO THE STARBOARD LEG TO WRAPPER CONNECTION DEFICIENCY._x001C_
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Construction/Loadline
Issued 1 February 1993 Resolved
PROVIDE A PROPOSAL TO [name withheld], TX FOR MAKING PERMANENT REPAIRSTO DAMAGED AREA ON PORT BOW AREA OF MAT TOP/FRONT EDGE.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Electrical
Issued 28 April 1992 Resolved
MAKE PERMANENT REPAIRS TO STORM GENERATOR AND DEMONSTRATE PROPER OPERATION.
Condition: Unknown
Due 28 April 1992
Resolved 28 April 1992
Deck/Cargo
Issued 28 April 1992 Resolved
MAKE PERMANENT REPAIRS TO CRACKED WELD ON PORT CRANE BASE FORWARD OUTBOARD CORNER.
Condition: Unknown
Due 28 April 1992
Resolved 28 April 1992
Engineering
Issued 28 April 1992 Resolved
PROVIDE HEAT SHIELDS FOR RACOR WATER SEPARATORS ON # 1 AND 2 SERVICE GENERATORS, # 1-3 MUD PUMP ENGINES, AND # 3 DRAW-WORKS ENGINE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 April 1992
Resolved 28 April 1992
Lifesaving
Issued 28 April 1992 Resolved
MARK # 1 LIFEBOAT WITH NAME, HOME PORT, AND CAPACITY IAW 46CFR108.645.
Condition: Unknown
Due 28 April 1992
Resolved 28 April 1992
Engineering
Issued 28 April 1992 Resolved
RENEW ALL DETERIORATED FLEXIBLE FUEL LINES AND ONES WITH PUSH-ON FITTINGS ON # 1 AND 2 SERVICE GENERATORS, # 1-3 MUD PUMPS, AND # 1-3 DRAW-WORKS ENGINES.
Condition: Unknown
Due 28 April 1992
Resolved 28 April 1992
Electrical
Issued 26 October 1989 Resolved
MAKE PERMANENT REPAIRS TO EMERGENCY/REMOTE SHUT-DOWN FOR GENERATORS, VEN- TILATION, F.O. TRANS. & WASTE OIL PUMPS. PROVE PROPER OPERATION AFTER REPAIR.
Condition: Unknown
Due 26 October 1989
Resolved 26 October 1989
Deck/Cargo
Issued 26 October 1989 Resolved
HYDRO-TEST FUEL TRANSFER HOSES AT 1 1/2 TIMES MAWP AND PROVIDE DOCUAMENTA- TION.
Condition: Unknown
Due 26 October 1989
Resolved 26 October 1989
Unknown
Issued 26 October 1988 Resolved
REPAIR OR RENEW TWO DRY BULK RELIEF VALVES AND DEMONSTRATE PROPER OPERATIONOF SAME TO ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Construction/Loadline
Issued 13 October 1987 Resolved
PROVIDE PERSONNEL GUARDS FOR ALL AIR TUGGERS ON DECK. 46 CFR 108.223 AND NVIC 4.78 CH-1.
Condition: Unknown
Due 13 October 1987
Resolved 13 October 1987
Deck/Cargo
Issued 13 October 1987 Resolved
PERFORM HYDRO TEST ON FUEL OIL TRANSFER HOSE TO 1.5 TIMES MAXIMUM ALLOWABLEWORKING PRESSURE. STENCIL HOSE WITH PRESSURE USED, DATE OF TEST AND THE LABEL "OIL SERVICE" 33 CFR 155.800.
Condition: Unknown
Due 13 October 1987
Resolved 13 October 1987
Electrical
Issued 13 October 1987 Resolved
REPAIR BROKEN "EYS" FITTINGS ON ELECTRICAL JUNCTION BOXES (2) LOCATED ON AFT BULKHEAD OF THE DRILL FLOOR.
Condition: Unknown
Due 13 October 1987
Resolved 13 October 1987
Electrical
Issued 13 October 1987 Resolved
PROVIDE EMERGENCY LIGHTS FOR STAIRWAY ACCESS TO LIFEBOATS. NVIC 4-78-3-D.
Condition: Unknown
Due 13 October 1987
Resolved 13 October 1987
Fire Fighting
Issued 13 October 1987 Resolved
POST PAINT LOCKER CARBON DIOXIDE FIRE APPARATUS OPERATING INSTRUCTIONS WHICH REQUIRE 1) CLOSURE OF OVERHEAD EXHAUST AND SUPPLY VENTS 2) ENSURING THE SPACE IS EVACUATED 3) CLOSE AND DOG DOOR AND 4) PULL LEVER TO ACTIVATE CARBON DIOXIDE RELEASE.
Condition: Unknown
Due 13 October 1987
Resolved 13 October 1987
Electrical
Issued 13 October 1987 Resolved
PROPERLY INSTALL "EYS" FITTINGS ON JUNCTION BOX LOCATED AGAINST AFT BULKHEAD INSIDE PAINT LOCKER.
Condition: Unknown
Due 13 October 1987
Resolved 13 October 1987
Accommodation/Occupational Safety
Issued 13 October 1987 Resolved
PROVIDE PRESSURE-TEMPERATURE RELIEF DEVICES ON BOTH HOT WATER HEATERS (ELECTRIC) MEETING ANSI STANDARD Z21.22 WITH PRESSURE SETTINGS OF 100 PSIG OR LESS, OR MAKE THE UNITS AVAILABLE FOR INTERNAL INSPECTION BY MARINE INSPECTOR.
Condition: Unknown
Due 13 October 1987
Resolved 13 October 1987
Electrical
Issued 13 October 1987 Resolved
REMOVE DEAD END 3-WIRE CABLE (CONDUCTOR) LOCATED IN BOW LEG POD HOUSE.
Condition: Unknown
Due 13 October 1987
Resolved 13 October 1987
Engineering
Issued 13 October 1987 Resolved
INSTALL PROPER PRESSURE RELIEF VALVE ON COLD START AIR RECEIVER; AT LEAST ON INCH NOMINAL SIZE AND EQUIPPED WITH HAND RELIEVING DEVICE.
Condition: Unknown
Due 13 October 1987
Resolved 13 October 1987
Engineering
Issued 13 October 1987 Resolved
PROVIDE DOCUMENTATION DEMONSTRATING THE SIZE AND CAPACITY OF RELIEF VALVES ON BOTH AIR RECEIVERS IN AIR COMPRESSOR ROOM ARE SUFFICIENT. THE AIR RECEIVERS HAVE TWO INCH NOZZLES (OPENINGS) AND INLET; THOSE RELIEF VALVES PRESENTLY INSTALLED ARE SMALLER SIZE.
Condition: Unknown
Due 13 October 1987
Resolved 13 October 1987
Deck/Cargo
Issued 13 October 1987 Resolved
REPAIR STABBING BOARD SAFETY DEVICES AND HARNESS RIGGING; INTERLOCK SPRINGSON LATCHING DOGS MISSING.
Condition: Unknown
Due 13 October 1987
Resolved 13 October 1987
Construction/Loadline
Issued 24 October 1986 Resolved
COMPLETE SURVEY OF BOTTOM OF MAT AND PORT SIDE SCOUR SKIRT ON NEXT RIG MOVEBUT NOT LATER THAN 24OCT87.
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986
Unknown
Issued 19 March 1984 Resolved
PROVIDE INTAKE AIR FOR DRILL FLOOR AIR COMPRESSERS FROM AN UNCLASSIFIED LOCATION.
Condition: Unknown
Due 19 March 1984
Resolved 19 March 1984

Casualty record · 2

1 August 2012Routine · role: Involved in a Marine Casualty · activity 4398265
28 April 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 4846433
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record