Records from 1982 to 2001. Most recent: inspection, 12 March 2001.
Inspection history · 21
12 March 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1061399
10 January 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1057744
1 December 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 811060
3 October 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 167621
23 July 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 418581
23 July 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1440030
12 November 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 785756
30 June 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1465322
3 June 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1198749
25 November 1986
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1020121
15 January 1986
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1303257
4 November 1985
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1295656
21 June 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1290307
7 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 978877
29 January 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284435
18 January 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282126
3 December 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1284195
9 January 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1283346
1 June 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1275438
13 January 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 963591
9 November 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1278119
Documentation
Issued 23 July 1998
Resolved
GET A CURRENT COPY OF THE IOPP CERTIFICATE ONBOARD.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Documentation
Issued 30 June 1997
Resolved
Provide corrections to Operations Manual, as required in MSO Port Arthur ltr dtd 21JUL97 & provide proof of full class society approval, to [name withheld].
Condition: Unknown
Due 30 June 1997
Resolved 30 June 1997
Electrical
Issued 4 November 1985
Resolved
INSTALL A MUD PIT VENTILATION FAILURE ALARM PANEL AT A MANNED STATION AS REQUIRED BY 46 CFR 108.185(C).
Condition: Unknown
Due 4 November 1985
Resolved 4 November 1985
Fire Fighting
Issued 4 November 1985
Resolved
INSTALL AN APPROVED FIXED FIRE FIGHTING SYSTEM FOR THE PAINT LOCKER AND ENSURE THAT THE PAINT LOCKER DOORS CLOSE PROPERLY.
Condition: Unknown
Due 4 November 1985
Resolved 4 November 1985
Electrical
Issued 4 November 1985
Resolved
PROVIDE EMERGENCY LIGHTING FOR THE LOWERED POSITION OF THE PORT AND STBD LIFE CAPSULE STATIONS (#1 & #2).
Condition: Unknown
Due 4 November 1985
Resolved 4 November 1985
Navigation
Issued 4 November 1985
Resolved
PROVIDE THE RIG WITH NOT UNDER COMMAND LIGHTS AND DAY SHAPES.
Condition: Unknown
Due 4 November 1985
Resolved 4 November 1985
Electrical
Issued 4 November 1985
Resolved
PROVIDE 27 BUNK LIGHTS IN THE QUARTERS SO THAT EACH BUNK WILL HAVE ITS OWN LIGHT.
Condition: Unknown
Due 4 November 1985
Resolved 4 November 1985
Navigation
Issued 4 November 1985
Resolved
REPLACE THE BROKEN LENS COVER ON THE STBD AFT OBSTRUCTION LIGHT.
Condition: Unknown
Due 4 November 1985
Resolved 4 November 1985
Accommodation/Occupational Safety
Issued 4 November 1985
Resolved
REPAIR OR REPLACE THE INOPERATIVE #1 AIR COMPRESSOR MOTOR.
Condition: Unknown
Due 4 November 1985
Resolved 4 November 1985
Electrical
Issued 4 November 1985
Resolved
REPAIR OR REPLACE THE INOPERATIVE DIRTY OIL PUMP.
Condition: Unknown
Due 4 November 1985
Resolved 4 November 1985
Documentation
Issued 4 November 1985
Resolved
PROVIDE ON BOARD THE RIG THE USCG APPROVAL LETTER CERTIFYING THE EXISTING MARINE SANITATION DEVICE (MSD) AS AN APPROVED TYPE II UNIT.
Condition: Unknown
Due 4 November 1985
Resolved 4 November 1985
Electrical
Issued 29 January 1985
Resolved
PROVIDE FLASHING RED LIGHTS IN THE AC GENERATOR ROOM AND MUD PUMP OF SUFFICIENT UTENSITY TO WARN OCCUPANTS. 46 CFR 113.25-10(D)(2)
Condition: Unknown
Due 29 January 1985
Resolved 29 January 1985
Unknown
Issued 29 January 1985
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL, J STORM VIII, DN594761
Condition: Unknown
Due 29 January 1985
Resolved 29 January 1985
Electrical
Issued 29 January 1985
Resolved
PROVIDE GENERAL ALARM BELLS IN THE PUMP ROOM AND GENERATOR ROOM. 46 CFR 113.25-10(C).
Condition: Unknown
Due 29 January 1985
Resolved 29 January 1985
Unknown
Issued 3 December 1984
Resolved
PROVIDE AND INSTALL A PROTECTIVE HANDRAIL ON THE FRONT OF THE GENERATOR SWITCHBOARD.
Condition: Unknown
Due 3 December 1984
Resolved 3 December 1984
Unknown
Issued 3 December 1984
Resolved
MAKE REPAIRS TO THE GENERATOR SWITCHBOARD TO ALLOW PROPER FUNCTIONING OF THE PARALLELING APPARATUS.
Condition: Unknown
Due 3 December 1984
Resolved 3 December 1984
Unknown
Issued 3 December 1984
Resolved
REPAIR GENERAL ALARM BELLS AND LIGHTS IN THE MUD PIT ROOM, MUD PUMP ROOM, AND COMPRESSOR ROOM.
Condition: Unknown
Due 3 December 1984
Resolved 3 December 1984
Unknown
Issued 3 December 1984
Resolved
REPAIR THE STARBOARD SIDE MIDSHIP LIFEFLOAT.
Condition: Unknown
Due 3 December 1984
Resolved 3 December 1984
Accommodation/Occupational Safety
Issued 3 December 1984
Resolved
PROVIDE ASME APPROVED RELIEF VALVES FOR THE TWO (2) HOT WATER HEATERS.
Condition: Unknown
Due 3 December 1984
Resolved 3 December 1984
Unknown
Issued 3 December 1984
Resolved
PROVIDE FLAME SCREENS ON THE VENTS FOR THE DIESEL AND LUBE OIL TANKS LO- CATED ON THE DRILL FLOOR AND ENGINE SPACES.
Condition: Unknown
Due 3 December 1984
Resolved 3 December 1984
Deck/Cargo
Issued 3 December 1984
Resolved
REPAIR OR REMOVE THE RIG ANCHOR WINDLASS.
Condition: Unknown
Due 3 December 1984
Resolved 3 December 1984
Construction/Loadline
Issued 13 January 1983
Resolved
RENEW MISSING VENT COVERS AND MISSING INVERTED BALL CHECKS FOR MAIN DECK VENTS AS REQUIRED.
Condition: Unknown
Due 13 January 1983
Resolved 13 January 1983
Construction/Loadline
Issued 13 January 1983
Resolved
MAKE VESSEL AVAILABLE FOR UNDER WATER SURVEY OF THE BOTTOM OF THE MAT DURING THE NEXT RIG MOVE BUT PRIOR TO 01 AUGUST 1983.
Condition: Unknown
Due 1 August 1983
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 13 January 1983
Resolved
PROVIDE INTAKE AIR FOR THE DIESEL INTERNAL COMBUSTION ENGINES ON THE DRILL FLOOR, FROM AN UNCLASSIFIED LOCATION.
Condition: Unknown
Due 13 January 1983
Resolved 13 January 1983
Electrical
Issued 13 January 1983
Resolved
PROVIDE AND INSTALL ADDITIONAL SUPPORTS FOR THE ELECTRICAL CABLES IN THE STARBOARD SPONSON TANK.
Condition: Unknown
Due 13 January 1983
Resolved 13 January 1983
Unknown
Issued 9 November 1982
Resolved
PROVIDE SUITABLE PERSONNEL PROTECTION FOR EXHAUST STACKS FROM THE BELOW DECK INTERNAL COMBUSTION ENGINES, IN WAY OF THE MAIN DECK.
Condition: Unknown
Due 9 November 1982
Resolved 9 November 1982
Documentation
Issued 9 November 1982
Resolved
PROVIDE ONBOARD THE UNIT A COAST GUARD APPROVED OPERATIONS MANUAL
Condition: Unknown
Due 9 November 1982
Resolved 9 November 1982
Documentation
Issued 9 November 1982
Resolved
PROVIDE ONBOARD THE UNIT A VALID LOAD LINE CERTIFICATE.
Condition: Unknown
Due 9 November 1982
Resolved 9 November 1982
Documentation
Issued 9 November 1982
Resolved
PROVIDE ONBOARD THE UNIT A VALID STABILITY LETTER.
Condition: Unknown
Due 9 November 1982
Resolved 9 November 1982
Construction/Loadline
Issued 9 November 1982
Resolved
CONDUCT A DRYDOCK EXAMINATION OR SPECIAL IN LIEU OF DRYDOCK FOR CREDIT.
Condition: Unknown
Due 9 November 1982
Resolved 9 November 1982
Electrical
Issued 9 November 1982
Resolved
RENEW IMPROPERLY SPLICED ELECTRICAL CABLE IN THE EMERGENCY GENERATOR ROOM AND ON THE HELIPORT.
Condition: Unknown
Due 9 November 1982
Resolved 9 November 1982