11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 March 2026
Resolved
A lifeline attached to a lifebuoy must be, if synthetic, a dark color or certified by the manufacturer to be resistant to deterioration from ultraviolet light. All of the lifelines on respective lifebuoys are synthetic and not dark in color (yellow and orange combo) nor is there evidence that the lifelines are resistant to deterioration from ultraviolet light. Either replace with a dark in color synthetic line, natural fiber line or provide proof of UV resistance to that satisfaction of attending CG marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2026
Resolved 2 April 2026
Resolution: Lifelines replaced with dark synthetic material.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 March 2026
Resolved
Each lifebuoy stowage position must be marked with either the words “LIFEBUOY” or “LIFE BUOY”, or with the appropriate symbol. The stowage location of several of the lifebuoys onboard are marked with the wrong symbol. Either mark with the appropriate symbol or mark with the word lifebuoy or life buoy to the satisfaction of attending CG marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2026
Resolved 2 April 2026
Resolution: Verified markings and placement of placards
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 March 2026
Resolved
The self-igniting light may not be attached to the lifebuoys required by this section to be fitted with lifelines. Several lifebuoys onboard have both a waterlight and lifeline attached. Ensure all lifebuoys have the appropriate attachments.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2026
Resolved 2 April 2026
Resolution: Verified appropriate attachments on all life buoys IAW fire control plan.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 4 March 2026
Resolved
Each liferaft must be arranged to permit it to drop into the water from the deck on which it is stowed. A liferaft stowage arrangements meets this requirement if it — (i) Is outboard of the rail or bulwark; (ii) Is on stanchions or on a platform adjacent to the rail or bulwark; or (iii) Has a gate or other suitable opening large enough to allow the liferaft to be pushed directly overboard and, if the liferaft is intended to be available for use on either side of the vessel, such gate or opening is provided on each side of the vessel.
The current stowage arrangement of the existing liferaft does not appear that it can be manually launched and not strike the main deck or gunwale before landing in the water. Either prove that the existing arrangement meets the standard above or install a launching arrangement that does to the satisfaction of attending CG marine inspector. ** 46 CFR Subchapter W does not offer an exemption or alternative to this requirement for vessels on an Oceans route **
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2026
Resolved 2 April 2026
Resolution: Verified installation of launching apparatus for life raft to allow launching without risk of landing on main deck or gunwale.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 March 2026
Resolved
The lifejackets stowage positions must be marked with the words “LIFEJACKETS” as appropriate, or with the appropriate symbol from IMO Resolution A.760(18). The lifejacket stowage location for those stowed in the bunk rooms are not marked. Make appropriate markings for those lifejackets contained in the bunk rooms.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2026
Resolved 2 April 2026
Resolution: Verified markings
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 4 March 2026
Resolved
All crew spaces are to be constructed and arranged in a manner suitable to the purpose for which they are intended and so that they can be kept in a clean, workable, and sanitary condition. Berthing and accommodation spaces were used for storage, and toilet and washroom facilities are not in service due to lack of water to the facilities. Either ensure galley/mess and berthing/toilet spaces have appropriate water supply and are clean and free of debris to the satisfaction of a CG marine inspector, or request the to have overnight accommodations onboard removed from the COI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2026
Resolved 2 April 2026
Resolution: Verified operation of all toilets and sinks throughout accommodation areas and observed areas free of debris/storage.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 December 2024
Resolved
The following items which were verified as required during MARSEC level 1 in the security plan, and were not being implemented: No ID checks took place when inspectors arrived, the deck was not monitored by PIC, there was no record of security exercises for the company or record of drills for the current crew, the VSA stated that AIS is utilized when vessel is moored or anchored to ensure visibility of incoming vessels however the vessel does not have an AIS, no training records were on board for any crew members as stated is required for all crew even if they do not have security related duties.
33 CFR 104.215(e) (2)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 17 December 2024
Resolution: Vessel amended COI for not on an internation voyage removing need for security
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 December 2024
Resolved
Excessive excess gear found in the state rooms on board including a kitchen oven not currently in use.
46 CFR92.20-20(c)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 December 2024
Resolution: Removed items
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 December 2024
Resolved
No transfer procedures
33 CFR 155.720
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 December 2024
Resolution: Provided transfer procedures
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 December 2024
Resolved
No information displayed on company policy for sexual harassment policy.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 17 December 2024
Resolution: Signs added
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 December 2024
Resolved
Fuel lines exceeded 30 inches.
46CFR56.60-25 b 4
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 December 2024
Resolution: hard line installed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 December 2024
Resolved
Several alarm signals and lights were not marked.
46 CFR 113.25-20
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 17 December 2024
Resolution: signs added
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 December 2024
Resolved
Plastic zip ties supporting wires.
46 CFR 111.60-5
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 17 December 2024
Resolution: metal ties added
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 December 2024
Resolved
Dead end cables in engine room.
46 CFR 222.60-17 a
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 17 December 2024
Resolution: Cables secured
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 October 2023
Resolved
The requirements of 58.10-5(a), (c), and (d) shall apply to diesel engine installations. All installations shall be of marine type engines suitable for the intended service, designed and constructed in conformance with the requirements of this subchapter. Both the #1 port generator and the #2 starboard generator were found to be excessively leaking jacket water and lube oil. Rectify deficiency prior to the vessel's departure.
46CFR96.03(a)
46CFR58.10(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2023
Resolution: Both generators were intact with no leaks witnessed, deficiency cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 October 2023
Resolved
The requirements of 58.10-5(a), (c), and (d) shall apply to diesel engine installations. All installations shall be of marine type engines suitable for the intended service, designed and constructed in conformance with the requirements of this subchapter. Both generator high pressure fuel lines were missing supports or current supports were missing hardware enable the lines to chafe on the engine blocks. Rectify deficiency prior to the vessel's departure.
46CFR96.03(a)
46CFR58.10(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2023
Resolution: All high pressure fuel lines were properly supported on both generators, deficiency cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 October 2023
Resolved
The requirements of 58.10-5(a), (c), and (d) shall apply to diesel engine installations. All installations shall be of marine type engines suitable for the intended service, designed and constructed in conformance with the requirements of this subchapter. A lube oil leak was found on the starboard forward prime mover for the cargo pump. Rectify deficiency prior to vessel's departure.
46CFR96.03(a)
46CFR58.10(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2023
Resolution: The starboard forward prime mover for the cargo pump leak was rectified, deficiency cleared.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 16 October 2023
Resolved
Valves installed on the outside of the oil tanks must be arranged with a means of manual control locally at the valve and remotely from a readily accessible and safe location outside of the compartment in which the vales are located. The high suction remote fuel shut off valve for the forward fuel tank on the starboard side was not accessible from outside of the space containing the fuel oil tank.
46CFR96.03(a)
46CFR56.50-60(d)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2023
Resolution: The remote fuel shutoff valve was accessible outside the space, deficiency cleared.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 16 October 2023
Resolved
All other openings to a protected space must be capable of being closed. Both starboard aft engine room ventilation closures were unable to close properly. The most aft engine room ventilation closure was missing hardware for an even closure seat and the closure forward of the aft contained wasted gasket material.
46 CFR 95.16-30 (C)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2023
Resolved 16 November 2023
Resolution: All engine room ventilation closures were rectified, deficiency cleared.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 16 October 2023
Resolved
This subpart contains requirements for fluid power transmission and control systems and appurtenances. Except as otherwise provided for in this section, these requirements are applicable to the following fluid power and control systems: Starting systems for internal combustion engines used for main propulsion, main or auxiliary power, as the prime mover for any required emergency apparatus, or as the source of propulsion power in ship maneuvering thruster systems. The fuel filters for both generators were missing containment underneath where they were installed.
46CFR96.03(a)
46 CFR 58.30-1(a)(5)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2023
Resolved 16 November 2023
Resolution: All fuel filters had proper containment, deficiency cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2023
Resolved
Electrical installations on vessel's must ensure protection of passengers, crew, other persons, and the vessel from electrical hazards. A missing breaker on the port switchboard was uncovered enabling the possibility of electrical shock to a crew member.
46CFR96.05-1(a)
46CFR111.01-1(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2023
Resolved 16 November 2023
Resolution: A blank was installed, deficiency rectified.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 16 October 2023
Resolved
Each operation described in paragraphs (d), (e), and (f) of this section shall be fully recorded without delay in the Oil Record Book so that all entries in the book appropriate to that operation are completed. The following items were missing or not correctly logged in the oil record book: Signature missing of person having charge of the ship at the bottom of each page; the entry on 28JUL2023 was missing quantity of bunkers delivered and time transfer was conducted; weekly sounding were not being taken of tanks listed on 3.1 of the IOPP Form A.
33 CFR 151.25(h)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2023
Resolved 16 November 2023
Resolution: All required log entries were witnessed in the ORD, deficiency rectified.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 16 October 2023
Resolved
For each ship subject to regulation 5 and 6 of this Annex, details of fuel oil for combustion purposes delivered to and used on board shall be recorded by means of a bunker delivery note that shall contain at least the information specified in appendix V to this Annex. The following bunker delivery notes were missing from the last year: 28JUL2023; 04NOV2022; 31OCT2022; 29OCT2022; and 28OCT2022.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2023
Resolved 16 November 2023
Resolution: The vessel representative was unable to provide the missing delivery notes but crew training was conducted for the future, deficiency rectified.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 16 October 2023
Resolved
The bunker delivery note shall be accompanied by a representative sample of the fuel oil delivered taking into account the guidelines developed by the organization. The sample is to be sealed and signed by the supplier’s representative and the master or officer in charge of the bunker operation on completion of bunkering operations. There was not bunker samples on board of all bunkers taken from: 28JUL2023; 04NOV2022; 31OCT2022; 29OCT2022; and 28OCT2022.
MARPOL VI/18.8.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2023
Resolved 16 November 2023
Resolution: The missing bunker samples were not attainable but the company had the crew conduct training for future bunkering, deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 October 2023
Resolved
Manned barges shall carry at least two fire axes. The port side fire axe was found in bad repair.
46 CFR 95.60-5(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2023
Resolved 16 November 2023
Resolution: An additional new fire axe was placed on board, deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 October 2023
Resolved
At each inspection for certification, periodic inspection and at other times necessary, the inspector will determine that all fire-extinguishing equipment is in suitable condition. During operation test of the fire pump the MI noticed excessive water leakage from the pump. Crew was able to rectify the deficiency on the spot.
46CFR91.25-20(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 October 2023
Resolved 16 October 2023
Resolution: Rectified on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 October 2023
Resolved
Each life raft or group of life rafts must be arranged for float-free launching. The life raft was not installed in accordance with the manufacturer's instructions. The crew was able to rectify the deficiency on the spot.
46CFR96.06(a)
46CFR199.130(c)(7)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 16 October 2023
Resolution: Rectified on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 October 2023
Resolved
Illustrations and instructions in English, and any other appropriate language as determined must be conspicuously displayed at each muster station. The box containing the life jackets at the muster station was missing a donning placard. The crew was able to provide a placard on the spot.
46CFR96.06(a)
46CFR199.80(c)(5)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 16 October 2023
Resolution: Rectified on the spot.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 October 2023
Resolved
All vessels shall have efficient guard rails or bulwarks on decks and bridges. Upper rear guard rail on the corner of the second deck broken and requires repair.
46 CFR 92.25-5(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2023
Resolved 16 November 2023
Resolution: Guard rail was satisfactorily fixed, deficiency cleared.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 16 October 2023
Resolved
A complete recharge shall be carried for each self-contained breathing apparatus. Vessel requires another spare self-contained breathing apparatus charge.
46 CFR 96.35-20
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2023
Resolved 16 November 2023
Resolution: Spare SCBA bottles were acquired for the vessel, deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 16 October 2023
Resolved
Each fireman's outfit must consist of one self-contained breathing apparatus, one lifeline with a belt or a suitable harness, one flashlight, one flame safety lamp, one rigid helmet, boots and gloves, protective clothing, and one fire ax. One fireman’s outfit missing gloves.
46CFR96.35-10
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2023
Resolved 16 November 2023
Resolution: The missing fireman's outfit gloves acquired by the vessel, deficiency cleared.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 November 2022
Resolved
46 CFR 97.15-35
Onboard training, musters, and drills must be in accordance with subchapter W. Vessel shall complete and document required fire, abandon ship, man overboard, and security drills. To the satisfaction of attending USCG Marine Inspector during next annual exam.
Action required: 705 - Other - as specified
Resolved 16 November 2023
Resolution: Drills from Annual inspection has been logged and crew has been trained on the required logging of these evolutions, deficiency rectified.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 28 September 2022
Resolved
Barges with sleeping accommodations for more than six persons shall have permanently exhibited for the guidance of the officer in charge of the vessel the following plans: (a) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means of access to different compartments, decks, etc., and the ventilating systems including particulars of the master fan controls, the positions of dampers, the location of the remote means of stopping fans, and identification numbers of the ventilating fans serving each section. For vessels constructed on or after September 30, 1997 or for existing vessels which have their plans redrawn, the symbols used to identify the aforementioned details shall be in accordance with IMO Assembly resolution A.654(16).
Vessel is required to provide an up to date and accurate Fire Control Plan to the satisfaction of marine inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2022
Resolved 18 November 2022
Resolution: Walked fire control plan and found all satisfactory. Stamped approved.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 October 2021
Resolved
At each inspection, the inspector shall exmaine bilges in the machinery spaces to see that there is no accumulation of oil, excess amounts of oil and water observed in the machinery space bilge. 46CFR91.25-45(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 October 2021
Resolution: Oily water was removed by mobile transfer facility.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 October 2021
Resolved
It shall be the duty of the PIC to see that the vessel's fire fighting equipment is at all times ready for use. During test of main fire pump, multiple continous leaks were observed.
Action required: 10 - Deficiency Rectified
Resolved 29 October 2021
Resolution: Packing on pump was adjusted. No more leaks observed. PSI is satisfactory on gauge.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 15 October 2020
Resolved
No oil record book entries could be found since 24SEP2017. Provide oil record book.
Action required: 703 - Prior to bunkering operations
Due 7 December 2020
Resolved 7 December 2020
Resolution: Oil Record book started,older ones could not be located.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 October 2020
Resolved
Demonstrate proper operation of reverse power relays on ships service generators.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 December 2020
Resolved 7 December 2020
Resolution: Tested reverse Power Relays, Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 October 2020
Resolved
Demonstrate proper operation of ships service generators overspeed.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 December 2020
Resolved 7 December 2020
Resolution: Tested Overspeeds, sat
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 October 2020
Resolved
Excessive oil and fuel in the bilge, presenting portential fire hazard.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 December 2020
Resolved 7 December 2020
Resolution: Bilges cleaned of oil.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 October 2020
Resolved
Cooling water pipe on stbd side was found leaking and contained 05 temporary patches/doublers.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 January 2021
Resolved 19 January 2021
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 15 October 2020
Resolved
Provide registration for EPIRB.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 December 2020
Resolved 7 December 2020
Resolution: Epirb was regestered with NOAA
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 October 2020
Resolved
Potable water filter housing, holding 50psi, found with 02 soft patches next to welding and electrical machinery.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 December 2020
Resolved 7 December 2020
Resolution: New Potable water filter housing installed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 August 2019
Resolved
General Emergency Alarm red flashing light in aft engine room inop.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2019
Resolved 28 October 2019
Resolution: Red light replaced by crew and tested by ABS.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 4 August 2019
Resolved
Pipe running through watertight bulkhead between engine room and pump room was stuffed with rags. Permanently close this opening in the bulkhead.
Action required: 705 - Other - as specified
Due 3 September 2019
Resolved 6 August 2019
Resolution: Bulkhead opening was adequately sealed.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 4 August 2019
Resolved
Painter for liferaft not installed IAW manufacturer's instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2019
Resolved 28 October 2019
Resolution: Painter properly reinstalled by ship's crew and considered satisfactory by ABS.
01 - Certificates & Documentation › 011 - Ships Certificates › International Air Pollution Certificate (IAPP)
Issued 4 August 2019
Resolved
The International Air Pollution Prevention Certificate issued by ABS should be issued on behalf of the United States of America.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2019
Resolved 28 October 2019
Resolution: Vessel has been issued a new IAPP.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 4 August 2019
Resolved
The International Load Line Certificate issued by ABS shall be issued on behalf of the United States of America.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2019
Resolved 28 October 2019
Resolution: Vessel has been issued a new ICLL certificate.
Lifesaving › Inflatable Liferafts › Servicing
Issued 11 April 2018
Resolved
11135 - Life raft servicing due 15 Apr 2018 extended for 60 days to get servicing completed in Bahrain.
Action required: 705 - Other - as specified
Due 11 July 2018
Resolved 21 June 2018
Resolution: Inspections have been completed by an authorized servicing facility.
Documentation › Certificates/Documents › Construction and Equipment Certificate (DSC)
Issued 11 April 2018
Resolved
15109 - Crane servicing due. Provide servicing report.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 7 May 2018
Resolution: Completed
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 11 April 2018
Resolved
07115 - Engine room vent closures not closing completely. Repair closures to provide a good seal.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 7 May 2018
Resolution: Completed
Fire Fighting › Means of Escape › Handrails/Handholds
Issued 11 April 2018
Resolved
99101 - Handrail support brackets wasted leading up the A frame. Repair or replace handrail supports as needed.
Action required: 705 - Other - as specified
Due 11 July 2018
Resolved 30 June 2018
Resolution: Repaired brackets.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 11 April 2018
Resolved
07123 - Paint locker doors do not properly secure. Repair doors to allow for good seal.
Action required: 705 - Other - as specified
Due 11 July 2018
Resolved 30 June 2018
Resolution: Repaired doors.
Lifesaving › Lifebuoys › Serviceable
Issued 11 April 2018
Resolved
11117 - Life ring missing sealing plug and needs new line attached. Replace life ring with new line attached.
Action required: 10 - Deficiency Rectified
Resolved 11 April 2018
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 11 April 2018
Resolved
14499 - MSD flange missing several bolts. Install missing bolts on MSD flange.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 7 May 2018
Resolution: Completed
Lifesaving › Inflatable Liferafts › Servicing
Issued 25 October 2016
Resolved
Issued 835 extending liferaft servicing date for 5 months or until next scheduled vessel exam whichever comes first as per 46 CFR 199.190(g).
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 17 May 2017
Resolution: Servicing completed.
Engineering › Lubricating Oil Service System › Hose
Issued 28 March 2016
Resolved
Replace oil soaked non-metallic fuel hoses, non-approved fuel hoses, and make permanent piping for non-metallic fuel hoses exceeding 30 inches. All fuel hoses in the engine room
must be approved ASME J1942 hoses with factory-assembled fittings.
Due 28 April 2016
Resolved 10 May 2016
Resolution: Vessel replaced all hoses.
Lifesaving › Inflatable Liferafts › Boarding Ramp/Ladder
Issued 28 March 2016
Resolved
Relocate inflatable life raft and bracket to STBD side, port side does not have room to board raft due to dredge pipe and does not have an embarkation station.
Due 28 April 2016
Resolved 10 May 2016
Resolution: Vessel relocated life raft station to the STBD side.
Documentation › Logs/Records › Logbook (official)
Issued 28 March 2016
Resolved
Provide a corrective action plan to ensure all drills to include firefighting, abandon ship, and security are being completed and logged. The vessel could only provide records of two drills being conducted in 2015.
Due 28 April 2016
Resolved 10 May 2016
Resolution: Vessel provide records of drills and will now make hard copies as well as electronic.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 28 March 2016
Resolved
Provide documentation that all fuel transfer piping has been tested to 1.5 times its max allowable working pressure.
Due 28 April 2016
Resolved 10 May 2016
Resolution: Vessel provide documentation of testing.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 March 2016
Resolved
Install rail guards on range and provide a securing latch for the oven.
Due 28 April 2016
Resolved 10 May 2016
Resolution: Vessel installed guards on range.
Documentation › Logs/Records › Oil Record Book
Issued 28 March 2016
Resolved
Provide proof of training to all personnel who complete oil record book entries. Record book
was missing entries and some entries were not in accordance with the guidance provided in
the book.
Due 28 April 2016
Resolved 10 May 2016
Resolution: Vessel provided Oil Record Book training to all engineering personnel.
Fire Fighting › Fire Pumps › Power Source
Issued 28 March 2016
Resolved
Repair fire pump number 1 motor control.
Due 28 April 2016
Resolved 10 May 2016
Resolution: Vessel installed new fire pump motor control.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 28 March 2016
Resolved
Repair broken electrical couplings on the #4 man engine and #1 generator instrumentation boxes
Due 28 April 2016
Resolved 10 May 2016
Resolution: vessel repaired couplings.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 28 March 2016
Resolved
Remove patches and make permanent repairs on the #2 stbd-cooling pump piping. As discussed.
Due 28 April 2016
Resolved 10 May 2016
Resolution: Vessel installed new piping.
Fire Fighting › Means of Escape › Blocked
Issued 28 March 2016
Resolved
Install emergency escape ladder next to #2 engine.
Due 28 April 2016
Resolved 10 May 2016
Resolution: Vessel installed ladder.
Engineering › Diesel Engine (auxiliary) › Piping (air intake)
Issued 28 March 2016
Resolved
Ensure intake on the #4 main engine has all required bolts.
Due 28 April 2016
Resolved 10 May 2016
Resolution: Vessel replaced all bolts.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 March 2016
Resolved
Repair all navigation lights and ensure they are
the correct color.
Due 28 April 2016
Resolved 10 May 2016
Resolution: Vessel provided new NAVlights.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 28 March 2016
Resolved
Remove all excess oil from bilge.
Due 28 April 2016
Resolved 10 May 2016
Resolution: All oil was cleaned.
Fire Fighting › Fire Hydrants › Material
Issued 28 March 2016
Resolved
Properly secure all spanner wrenches.
Due 28 April 2016
Resolved 10 May 2016
Resolution: All spanner wrenches were properly secured.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 28 March 2016
Resolved
Replace life rings lights on the both fwd stbd and fwd port life rings.
Due 28 April 2016
Resolved 10 May 2016
Resolution: Two new lights were installed.
Engineering › Bilge Water Management System › Piping
Issued 26 January 2015
Resolved
Provide Void/Ballast vents as per approved scantling plan.
Due 26 April 2015
Resolved 23 March 2015
Documentation › Certificates/Documents › Dedicated Clean Ballast Tanks Amending Letter
Issued 15 November 2014
Resolved
The barge ballast system/is disabled. The ballast system must meet requirements in the stability letter issued and must function as designed.
Action required: 705 - Other - as specified
Due 26 April 2015
Resolved 23 March 2015
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 14 November 2014
Resolved
Vessel fire control plan does not reflect equipment on board the vessel. Operator must provide USCG with an updated vessel control plan for approval.
Action required: 705 - Other - as specified
Due 15 February 2015
Resolved 26 January 2015
Documentation › Certificates/Documents › Intact Stability Booklet
Issued 14 November 2014
Resolved
The barge failed to make available a plan showing the barge piping system, in particular the ballast system. The vessel must produce a set of approved plans to the USCG.
Action required: 705 - Other - as specified
Due 26 April 2015
Resolved 23 March 2015
Engineering › Bilge Water Management System › Vent
Issued 14 November 2014
Resolved
Provide Void/Ballast vents as per approved scantling plan.
Action required: 705 - Other - as specified
Due 26 May 2015
Resolved 15 November 2014
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 14 November 2014
Resolved
Provide emergency lighting in the berthing space.
Action required: 705 - Other - as specified
Due 26 April 2015
Resolved 23 March 2015
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 14 November 2014
Resolved
Remove all non-Coast Guard approved portable fire extinguishers and replace with extinguishers that have been approved by UL, the USCG and labeled in accordance with 46 CFR 162.028.
Action required: 705 - Other - as specified
Due 26 April 2015
Resolved 23 March 2015
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 14 November 2014
Resolved
Repair nonoperational bilge alarm in the E/R. Four alarms were tested, two found to be nonoperational. Repair bilge alarm to satisfaction of the OCMI.
Action required: 705 - Other - as specified
Due 22 November 2014
Resolved 15 November 2014
Documentation › Certificates/Documents › Stability Letter
Issued 14 November 2014
Resolved
Alternation/modification was made to the barge deviating from of the original plan IWO the ballast and void spaces (addition of 3' volume to each tank). Update plans to cover the modification that was completed addressing the validity of the stability letter.
Action required: 705 - Other - as specified
Due 14 November 2014
Resolved 15 November 2014
Engineering › Freshwater Generation System › Heat Exchanger
Issued 10 March 2014
Resolved
Provide Specification for newly installed water heater safety valve.
Condition: Placed in Improper Service
Due 10 April 2014
Resolved 9 April 2014
Resolution: Safety valve was within manufactures specification.
Engineering › Bilge Water Management System › Interface Detector
Issued 10 March 2014
Resolved
Provide bilge alarm for forward storage compartment.
Condition: Invalid
Due 10 April 2014
Resolved 9 April 2014
Resolution: Working bilge alarm provided.
Electrical › Electric Supply System (service) › Cable
Issued 10 March 2014
Resolved
Provide A-O electrical penetration compound for bulkhead between engine room and pump room
Condition: Improper Installation
Due 10 April 2014
Resolved 9 April 2014
Resolution: Proper A-O penetration conduit used.
Engineering › Compressed Air System (start air) › Valve
Issued 10 March 2014
Resolved
Un-seize #1 relief valve for #1 pressure vessel.
Condition: Improper/Lack of Maintenance
Due 10 April 2014
Resolved 9 April 2014
Resolution: Refurbished the valve to #1 pressure vessel
Electrical › Electric Supply System (service) › Cable
Issued 10 March 2014
Resolved
Secure wiring for overhead light in lower level storage forward .
Condition: Improper Installation
Due 10 April 2014
Resolved 9 April 2014
Resolution: Added additional metal securing clips to support the overhead light wiring.
Documentation › Logs/Records › Bunker Delivery Notes/Samples
Issued 18 November 2012
Resolved
Retain Bunker Delivery Notes and fuel samples on board vessel for verification at next CG attendance.
Action required: 705 - Other - as specified
Resolved 16 September 2013
Resolution: Bunker notes and fuel samples shown on request.
Documentation › Logs/Records › Oil Record Book
Issued 18 November 2012
Resolved
Ensure Oil Record Book is being maintained in accordance w/ instructions for verification at next CG attendance.
Action required: 705 - Other - as specified
Resolved 16 September 2013
Resolution: ORB was being correctly maintained at time of attendance for deficency check.
Electrical › Electric Generation Source (service) › Panelboard
Issued 18 November 2012
Resolved
Prove function of reverse power relay for ship service generators. **Jayant Gokhale, Maintenance Superintendent, claims repair and successful testing of equipment. Verify at next CG attendance.**
Action required: 705 - Other - as specified
Due 15 February 2013
Resolved 16 September 2013
Resolution: Repaired Reverse Power Relay and demonstrated operation to USCG MI.
Electrical › Electric Generation Source (service) › Panelboard
Issued 18 November 2012
Resolved
Prove proper operation of generator #1 speed control switch on switchboard. Switch will not lower engine speed. **Jayant Gokhale, Maintenance Superintendent, claims repair and successful testing of equipment. Verify at next CG attendance.**
Action required: 705 - Other - as specified
Due 15 February 2013
Resolved 16 September 2013
Resolution: Demonstrated proper operation to USCG MI.
Electrical › Electric Generation Source (service) › Generator
Issued 18 November 2012
Resolved
Prove ability to parallel ship service generators. **Jayant Gokhale, Maintenance Superintendent, claims repair and successful testing of equipment. Verify at next CG attendance.**
Action required: 705 - Other - as specified
Due 15 February 2013
Resolved 16 September 2013
Resolution: Demonstrated proper operation to USCG MI
Engineering › Fuel Oil Service System › Hose
Issued 18 November 2012
Resolved
Prove SAE J-1942 rating of fuel hoses at pump drive generator fuel filters, or replace w/ hoses rated as such. **Jayant Gokhale, Maintenance Superintendent, claims repair and successful testing of equipment. Verify at next CG attendance.**
Action required: 705 - Other - as specified
Due 15 February 2013
Resolved 16 September 2013
Resolution: Noted hoses have been replaced with appropriate hoses.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 11 March 2010
Resolved
Vessel not manned in accordance with the provisions set forth on the Certificate of Inspection (COI). No persons on board found with a valid U.S. Merchant Mariner's Document endorsed as a Lifeboatman. Vessel to be manned in accordance with the COI prior to conducting operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2010
Resolution: New PIC provided on board. Documents verified by attending USCG MI as being valid.
Fire Fighting › Firemans Outfit › Quantity
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 26MAR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*Both fireman's outfits found stored in the forward storage room. Provide two widely separated, accessible locations, suitable for storage of the respective fireman's outfits as required by 46 CFR 96.35-15 within 7 days. 18 March 2010.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 15 April 2011
Resolution: rcvd email from vsl manager clearing deficiency
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 20MAR10 and shall remain open until verified to be corrected by attending MI*Provide on board clear and updated instructions, bunk-cards, and muster list that detail the action each person on board should follow in the event of an emergency in accordance with 46 CFR 199.80(a)(b), to include the location of the muster station, within 7 days. 18 March 2010.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 8 March 2012
Resolution: cleared during annual inspection.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 31MAR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*Provide on board Lifesaving Training Manuals which reflect the actual equipment fitted on board in accordance with 46 CFR 199.180(a), within 7 days. 18 March 2010
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 23 September 2010
Documentation › Logs/Records › Oil Record Book
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 31MAR10 and shall remain open until verified by MI* The only entries noted in the Oil Record Book dating from April 2002 through present reflect the bunkering of lubrication oil. Multiple other discrepancies noted. Company to carryout internal audit regarding Oil Record Book keeping and training to personnel regarding entries, within 7 days. 18 March 2010.
Action required: 705 - Other - as specified
Due 18 April 2012
Resolved 12 January 2012
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 31MAR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*The muster station and liferaft embarkation station is to be provided with lighting that is capable of having its power supplied by the vessel's emergency source of electrical power (batteries in lieu of emergency generator) within 14 days. 25 March 2010.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 23 September 2010
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 26MAR10 and shall remain open until verified to be corrected by attending USCG MI*Vessel's operator to access the suitability of the current muster station and liferaft embarkation station which is located adjacent to a 240 gallon fuel tank. Station to be relocated or justification for current location to be provided within 14 days. 25 March 2010.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 23 September 2010
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 28APR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*Hydrostatic release for vessel's liferaft found to be not USCG approved. USCG approved hydrostatic release to be provided on board within 14 days. 25 March 2010.**Extended to 4/15/2010**
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 23 September 2010
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 20MAR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*Outboard shackle for liferaft containment strap requires replacement. Replace per manufacturer's instructions within 14 days. 25 March 2010.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 23 September 2010
Lifesaving › Rocket Parachute Flares › General
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 20MAR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*One red-rocket flare found missing, only 11 onboard where 12 are required. Provide USCG approved red-rocket flare on board within 14 days. 25 March 2010.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 23 September 2010
Fire Fighting › Firemans Outfit › Lantern (Electric Safety Lamp)
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 28APR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*Provide on board two flashlights, one for each fireman's outfit, which are Type II or Type III, constructed and marked in accordance with ASTM F 1014 as required by 46 CFR 96.35-5(c) within 14 days. 25 March 2010.**Extended to 4/15/2010**
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 23 September 2010
Documentation › Certificates/Documents › International Load Line Certificate
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 31MAR10 and shall remain open until verified by MI* Vsl's ILLC found not endorsed for 2008 annual audit. Certificate was endorsed in 2008 for a renewal survey per article 19(4), however, no date of validity was provided. Certificate issuing authority requested to attest to the 2008 annual survey as required by article 14(1)(c) within 14 days. 25 March 2010.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 23 September 2010
Fire Fighting › Fire Pumps › Arrangement
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 13MAR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*Pressure gauge for the emergency fire pump found inoperative. Make proper repairs and restore operational readiness within 14 days. 25 March 2010.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 23 September 2010
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 13MAR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*Soak back oil pump pressure gauges for EMD's #1 and 2 found inoperative. Make proper repairs and restore operational readiness within 14 days. 25 March 2010.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 23 September 2010
Construction/Loadline › Structures › Deck Plating
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 20MAR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*Upper weather deck, over EMD's #3 and 4, found with multiple holes and wastage both on the centerline and stbd. side. Plate to be cropped to good steel and renew as original within 14 days. 25 March 2010.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 23 September 2010
Construction/Loadline › Structures › Deck Plating
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 20MAR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*Upper weather deck , port quarter, found holed and wasted. Plate to be cropped to good steel and renew as original within 30 days. 11 April 2010.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 8 March 2011
Resolution: cleared during annual inspection.
Stability › Freeing Ports › General
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 26MAR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*Multiple deck drains and scuppers found blocked with wasted piping. Make proper repairs within 14 days. 25 March 2010.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 23 September 2010
Construction/Loadline › Structures › Deck Plating
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 26MAR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*Upper weather deck, engine room overhead, port side forward, found with a doubler. Doubler to be removed, affected area to be cropped to good steel, and renewed as original within 14 days. 25 March 2010.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 23 September 2010
Construction/Loadline › Structures › Superstructure
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 20MAR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*Ladder/stair housing, port and stbd, in way of laundry room and stores found with multiple holes and wasted. Make proper repairs, crop wasted areas to good steel, and renew as original within 14 days. 25 March 2010.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 23 September 2010
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 26MAR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*Provide proper closure for natural vent and proper nozzle for fixed CO2 extinguisher in paint locker within 14 days. 25 March 2010.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 23 September 2010
Electrical › Electric Supply System (service) › Cable
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 26MAR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*Provide wire conduit for pump drive air conditioning unit, upper weather deck port side, within 14 days. 25 March 2010.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 23 September 2010
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 20MAR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*Coaming for pumps #1 and 2, port and stbd, found holed, wasted, and with clad welds. Make proper repairs, crop wasted/temp. repair areas to good steel, and renew as original within 14 days. 25 March 2010.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 23 September 2010
Construction/Loadline › Structures › End Bulkhead
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 20MAR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*Multiple (8+) brackets/supports for bulkhead supporting spud winch room found holed and heavily wasted. Make proper repairs, crop wasted areas to good steel, and renew as original within 14 days. 25 March 2010.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 8 March 2011
Resolution: cleared during annual inspection.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 20MAR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*Engine room bulkhead stbd. side aft found holed in way of weather tight door. Make proper repairs, crop wasted areas to good steel, and renew as original within 14 days. 25 March 2010.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 23 September 2010
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 26MAR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*Multiple steps/stairs associated with the "A-frame" found holed and wasted. Make proper repairs, crop wasted areas to good steel, and renew as original within 14 days. 25 March 2010.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 23 September 2010
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 20MAR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*Diamond plate, port side, upper deck in way of ladder leading down to main deck found holed/wasted. Make proper repairs, crop wasted areas to good steel, and renew as original within 14 days. 25 March 2010.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 23 September 2010
Construction/Loadline › Hull › Bracket
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 26MAR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*Forward upper storage room, stbd. side aft, found with wasted bracket/support toes. Make proper repairs, crop wasted area to good steel, and renew as original within 14 days. 25 March 2010.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 8 March 2011
Resolution: cleared during annual inspection
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 31MAR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*Seawater discharge line found with pin-hole leaks. Make proper repairs, crop wasted are to good steel, and renew piping as original within 14 days. 25 March 2010.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 23 September 2010
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 26MAR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*Multiple diamond plate steps leading to/from engine room found holed. Steps to be replaced as original within 14 days. 25 March 2010.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 23 September 2010
Construction/Loadline › Structures › Deck Plating
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 26MAR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*Spud winch room deck (engine room overhead), port side, founded severely holed and wasted. Deck plate permitted to be temporarily reinforced and strengthened. Temporary repairs to be carried out within 14 days. 25 March 2010.
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 8 March 2011
Resolution: cleared during annual inspection.
Communications › Radio Communications › EPIRB
Issued 11 March 2010
Resolved
*Item reported cleared via E-mail dated 12JUN10 and shall remain open until verified to be corrected by attending USCG MI*Due to the vessel being manned, with berthing provided for 5 persons, an appropriately registered EPIRB and portable lifeboat radio are to be provided on board within 30 days. 11 April 2010.**Extended to 4/15/2010**Extended to 6/6/2010**
Action required: 705 - Other - as specified
Due 18 April 2011
Resolved 23 September 2010
Construction/Loadline › Structures › Deck Plating
Issued 11 March 2010
Resolved
Spud winch room deck (engine room overhead), port side, founded severely holed and wasted. Permanent repairs to be made, deck plate to be cropped to good steel and renew as original within 4 months. 11 July 2010.**Extended to 31 August 2010**
Action required: 705 - Other - as specified
Due 31 August 2010
Resolved 8 March 2011
Resolution: cleared during annual inspection
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 20 January 2010
Resolved
Install manufacturer approved mounting brackets for portable fire extinguishers. Item reported cleared via Email from Bill Baumann dated 09Mar2010. Item to be verified during next CG attendance.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2010
Resolved 11 March 2010
Resolution: New approved mounting brackets for fire extinguishers found installed on board.
Operations/Management › Drills/Instruction › Fire
Issued 20 January 2010
Resolved
Provide Coast Guard approved fire control plan.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 February 2010
Resolved 8 March 2012
Resolution: CG approved fire control plan aboard the vessel.
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle
Issued 20 January 2010
Resolved
Provide two (2) SCBA bottles for fire fighter's outfit. Item reported completed via E-mail from Bill Baumann dated 09Mar2010. To be verified during next Coast Guard attendance.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 April 2010
Resolved 11 March 2010
Resolution: Two SCBA bottles for fire fighter''s outfits verified on board.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 5 February 2009
Resolved
Replace ring buoy grab lines throughout the vessel.
Due 5 April 2009
Resolved 11 March 2010
Resolution: New ring buoy grab lines provided on board.
Construction/Loadline › Structures › Superstructure
Issued 5 February 2009
Resolved
Properly repair fire equipment locker door, located near the MSD.
Due 5 April 2009
Resolved 7 January 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 February 2009
Resolved
Move/relocate eyewash machine above the batteries, located up forward compartment above the engine room.
Due 5 April 2009
Resolved 7 January 2010
Electrical › Electric Supply System (service) › Battery Installation
Issued 5 February 2009
Resolved
Remove spare battery, located up forward compartment above engine room.
Due 5 April 2009
Resolved 7 January 2010
Documentation › Markings/Placards › Warning Signs
Issued 5 February 2009
Resolved
Properly repair or replace all safety signs throughout the vessel that show signs of deterioration.
Due 5 April 2009
Resolved 11 March 2010
Resolution: New safety signs provided on board.
Communications › Alarms/Indicators › General Alarm
Issued 5 February 2009
Resolved
Demonstrate proper operation of the general alarm system. Ensure alarms are heard/ visually noticed all throughout the engine compartment, including the ECR.
Due 5 April 2009
Resolved 23 September 2010
Engineering › Fuel Oil Service System › Filter
Issued 5 February 2009
Resolved
Provide fuel filter bowl, located forward of genset #1.
Due 5 April 2009
Resolved 7 January 2010
Engineering › Fuel Oil Service System › Gauge
Issued 5 February 2009
Resolved
Properly mount fuel oil pressure gauges, located forward of genset #1 and near genset #5.
Due 5 April 2009
Resolved 11 March 2010
Resolution: Fuel oil pressure gauges found properly mounted.
Electrical › Lighting (service) › Lighting Fixture
Issued 5 February 2009
Resolved
Repair all broken light covers outside of Port Side and STBD side gensets.
Due 5 April 2009
Resolved 7 January 2010
Construction/Loadline › Structures › Door
Issued 5 February 2009
Resolved
Prove proper operation of watertight doors IWO Port side storage space and STBD side storage hold.
Due 5 April 2009
Resolved 11 March 2010
Resolution: Watertight doors found properly installed and operational.
Construction/Loadline › Structures › Door
Issued 5 February 2009
Resolved
Chalk test and make necessary repairs so that all watertight doors are watertight.
Due 5 April 2009
Resolved 11 March 2010
Resolution: Doors previously chalktested and found to be weathertight/watertight.
Engineering › Compressed Air System (start air) › Valve
Issued 5 February 2009
Resolved
Test air receiver safety relief valves that were due for testing in 2007.
Due 5 April 2009
Resolved 7 January 2010
Engineering › Diesel Engine (auxiliary) › Valve
Issued 5 February 2009
Resolved
Prove proper operation of the STBD side D399 CAT.
Due 5 April 2009
Resolved 23 September 2010
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 5 February 2009
Resolved
Provide lagging on exhaust for STBD side D399 CAT.
Due 5 April 2009
Resolved 7 January 2010
Electrical › Electrical Distribution System (service) › Panelboard
Issued 5 February 2009
Resolved
Check all electrical covers and repair any panels that need to be repaired.
Due 5 April 2009
Resolved 11 March 2010
Resolution: Electrical covers found repaired.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 February 2009
Resolved
Tighten all railing throughout deck.
Due 5 April 2009
Resolved 11 March 2010
Resolution: Deck railings found repaired.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 5 February 2009
Resolved
Replace all fire suits onboard the vessel. Ensure fire suits are UL approved and meet CG standards.
Due 5 April 2009
Resolved 7 January 2010
Operations/Management › Drills/Instruction › Fire
Issued 5 February 2009
Resolved
Conduct a satisfactory fire drill in the presence of a CG Marine Inspector.
Due 5 April 2009
Resolved 11 March 2010
Resolution: Satisfactory fire drill conducted in laundry room in the presence of USCG Marine Inspector.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 5 February 2009
Resolved
Prove proper testing equipment for high water jacket sensors and conduct testing.
Due 5 April 2009
Resolved 11 March 2010
Resolution: Proper testing equipment (hot pot and temp sensor) provided on board, conducted high jacket water sensor testing for EMDs.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 February 2009
Resolved
Provide cover for AC unit located on upper deck STBD side.
Due 5 April 2009
Resolved 7 January 2010
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 February 2009
Resolved
Ensure all supplies are properly stored and stowed away from E-lighting and any essential lifesaving and/or machinery equipment.
Due 16 April 2011
Resolved 13 June 2016
Resolution: *Item reported cleared via E-mail dated 13MAR10 and shall remain open until verified to be corrected by attending USCG Marine Inspector*
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 February 2009
Resolved
Ensure outstanding CG-835s issued on 25 Feb 2008 (paint locker hatch and all packing tubes holding electrical cables on genset 2,4,6,8) are completed.
Due 5 April 2009
Resolved 11 March 2010
Resolution: Paint locker hatch and packing tubes found repaired.
Construction/Loadline › Hull › Bottom Plating
Issued 5 February 2009
Resolved
Remove all rust from the sea chest compartment, located Port side of the gland seal pump room.
Due 6 December 2009
Resolved 7 January 2010
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 25 February 2008
Resolved
Provide a letter stating who is the POIC and the alternate PIC
Due 15 March 2008
Resolved 5 February 2009
Fire Fighting › Miscellaneous Items › Materials for Overboard Outlets
Issued 25 February 2008
Resolved
Provide evidence that no less than 2 satisfactory fire drills with all equipment have been conducted nlt 01 Mar08
Due 1 March 2008
Resolved 5 February 2009
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 25 February 2008
Resolved
Ensure MSD has chemicals and is being used properly
Due 15 March 2008
Resolved 5 February 2009
Documentation › Certificates/Documents › IOPP Certificate
Issued 25 February 2008
Resolved
Get IOPP onboard
Due 15 March 2008
Resolved 25 February 2008
Engineering › Diesel Engine (auxiliary) › Crankcase
Issued 25 February 2008
Resolved
Repair port AC generator oil seal
Due 15 March 2008
Resolved 5 February 2009
Electrical › Electrical Distribution System (emergency) › Distribution Panel Bus
Issued 25 February 2008
Resolved
Demonstrate proper operation of the emergency lighting throughtout vessel
Due 15 March 2008
Resolved 5 February 2009
Lifesaving › Inflatable Liferafts › Approval
Issued 25 February 2008
Resolved
Get liferafts with updated certificates on board
Due 15 March 2008
Resolved 5 February 2009
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 25 February 2008
Resolved
Clean area behind stove
Due 15 March 2008
Resolved 5 February 2009
Construction/Loadline › Structures › Door
Issued 25 February 2008
Resolved
Repair latch on paint locker storage box
Due 5 April 2009
Resolved 7 January 2010
Resolution: Viewed repaired latch.
Engineering › Diesel Engine (auxiliary) › Air Cleaner
Issued 25 February 2008
Resolved
Clean bulkhead of excess oil from 399 gen
Due 15 March 2008
Resolved 5 February 2009
Engineering › Diesel Engine (auxiliary) › Distributor (fuel injection)
Issued 25 February 2008
Resolved
Repair or replace the fuel oil lines on the DC gens as required
Due 15 March 2008
Resolved 5 February 2009
Electrical › Electric Generation Source (service) › Generator Cable
Issued 25 February 2008
Resolved
Properly stuff all packing tubes holding electrical cables.
Due 5 April 2009
Resolved 11 March 2010
Resolution: Packing tubes holding electrical cables verfied.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 14 December 2006
Resolved
Provide at least two more Coast Guard approved lifejackets
Action required: 705 - Other - as specified
Resolved 18 January 2007
Construction/Loadline › Penetrations › Weld
Issued 14 December 2006
Resolved
Crop and renew holed bulkhead in way of starboard quarter main deck.
Action required: 705 - Other - as specified
Resolved 18 January 2007
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 14 December 2006
Resolved
Remove all standing oil from bilges.
Action required: 705 - Other - as specified
Resolved 18 January 2007
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 14 December 2006
Resolved
Remove hose and permanently secure low point drain valve at the lube oil tank.
Action required: 705 - Other - as specified
Resolved 18 January 2007
Electrical › Lighting (emergency) › Lighting Fixture
Issued 14 December 2006
Resolved
Demonstrate proper operation of the emergency lighting in the forward pipe room.
Action required: 705 - Other - as specified
Resolved 18 January 2007
Lifesaving › Inflatable Liferafts › Container Construction
Issued 14 December 2006
Resolved
Crop and renew wasted life raft support members.
Action required: 705 - Other - as specified
Resolved 18 January 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 14 December 2006
Resolved
Clean entire length or replace dryer ventilation tube.
Action required: 705 - Other - as specified
Resolved 18 January 2007
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 14 December 2006
Resolved
Clean area behind the stove.
Action required: 705 - Other - as specified
Resolved 18 January 2007
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 14 December 2006
Resolved
Demonstrate proper operation of all smoke detectors.
Action required: 705 - Other - as specified
Resolved 18 January 2007
Accommodation/Occupational Safety › Ventilation › General
Issued 14 December 2006
Resolved
Clean entire length of accommodation air vents.
Action required: 705 - Other - as specified
Resolved 18 January 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 December 2006
Resolved
Remove dead end wiring from store room.
Action required: 705 - Other - as specified
Resolved 18 January 2007
Engineering › Diesel Engine (auxiliary) › Air Cleaner
Issued 14 December 2006
Resolved
Replace dirt laden air intake filters topside.
Action required: 705 - Other - as specified
Resolved 18 January 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 December 2006
Resolved
Install three courses of rails around perimeter of barge.
Action required: 705 - Other - as specified
Resolved 18 January 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 December 2006
Resolved
Mount electrical wiring in way of the soak back pumps.
Action required: 705 - Other - as specified
Due 31 January 2007
Resolved 20 January 2007
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 14 December 2006
Resolved
Demonstrate proper operation of the reverse power relays.
Action required: 705 - Other - as specified
Resolved 18 January 2007
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 14 December 2006
Resolved
Demonstrate proper operation of the low lube oil and high jacket water temperature alarms on the Caterpillar generators.
Action required: 705 - Other - as specified
Resolved 18 January 2007
Engineering › Fuel Oil Service System › Valve
Issued 14 December 2006
Resolved
Demonstrate proper operation of the remote fuel shut-offs.
Action required: 705 - Other - as specified
Resolved 18 January 2007
Engineering › Lubricating Oil Service System › Flange
Issued 1 February 2005
Resolved
Multiple leaking joints on the hydraulic pump seal piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 21 March 2005
Resolution: Tightened joints and tested system.
Fire Fighting › Means of Escape › Handrails/Handholds
Issued 1 February 2005
Resolved
Repair emergency escape hatch handle to operate properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 21 March 2005
Resolution: Handle repaired.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 February 2005
Resolved
Install guard on exhaust stack outside emergency escape hatch on upper deck.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 3 April 2005
Communications › Alarms/Indicators › General Alarm
Issued 1 February 2005
Resolved
Aft general alarm bell in engine room not working properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 21 March 2005
Resolution: Replaced bell.
Engineering › Fuel Oil Service System › Hose
Issued 1 February 2005
Resolved
Non metallic fuel lines not approved. Install approved fuel lines.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 21 March 2005
Resolution: New fuel lines installed as a single length without joints.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 1 February 2005
Resolved
Missing 1 Type 1 PFD. Required 10 as listed on COI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 21 March 2005
Resolution: Lifejacket procured.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 1 February 2005
Resolved
Replace liferaft hydrostatic release unit with CG approved unit.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 21 March 2005
Resolution: CG approved hydrostatic release installed.
Stability › Intact Righting Energy › General
Issued 1 February 2005
Resolved
Remove temporary Conex box generator package on upper deck or submit new stability information for CG approval.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 3 June 2005
Deck/Cargo › Mooring/Anchoring › Anchor Cable
Issued 1 February 2005
Resolved
Conduct overload test anchor cables or replace with new cable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 21 March 2005
Resolution: Cables removed. New cables to be installed on sight.
Operations/Management › Drills/Instruction › Fire
Issued 1 February 2005
Resolved
Demonstrate proper use of fire fighting gear during fire drill.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 21 March 2005
Resolution: Crew conducted satisfactory fire drill.
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 1 February 2005
Resolved
Repair the water leaking from the #2 EMD recirculation pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 21 March 2005
Resolution: Installed new pump.
Lifesaving › Inflatable Liferafts › Servicing
Issued 1 February 2005
Resolved
Liferaft sent for annual servicing to Qatar Communications which was not approved for servicing Elliot liferafts. Vessel required to send liferaft to facility approved for Elliot liferafts. Vessel not allowed to operate with persons onboard until liferaft is serviced or until loaner raft onboard.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 March 2005
Resolved 11 April 2005
Resolution: Sent liferaft to Solas Marine in Dubai for servicing.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 28 March 2004
Resolved
Provide 01 additional USCG approved type I lifejacket to ensure a total of 10 type I lifejackets onboard vessel, until completed, only 09 persons are allowed onboard during operation of the vessel.
Condition: Damaged By Earlier Event
Due 28 March 2004
Resolved 4 February 2005
Construction/Loadline › Structures › Deck Plating
Issued 28 February 2004
Resolved
Modify starboard midships engineroom door to make the same water/weathertight. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Due 28 March 2004
Resolved 4 February 2005
Construction/Loadline › Structures › Scuttle
Issued 28 February 2004
Resolved
Make main deck void space hatches watertight.
Condition: Improper/Lack of Maintenance
Due 28 March 2004
Resolved 4 February 2005
Construction/Loadline › Penetrations › Flange Pad
Issued 28 February 2004
Resolved
Repair leak in service line and fit proper watertight penetration where pipe penetrates lower level of fwd engineroon bulkhead. LEGACY COMPONENT DESC: Pipe Flange
Condition: Improper Installation
Due 28 March 2004
Resolved 4 February 2005
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 28 February 2004
Resolved
Fit 30x30 mesh flame screens or equivalent arrangement through overlapping 20x20 mesh screens for all fuel & oil tanks.
Condition: Improper Installation
Due 28 March 2004
Resolved 4 February 2005
Construction/Loadline › Hull › Bracket
Issued 28 February 2004
Resolved
Replace bracket on aft port bulkhead of gym/storeroom.
Condition: Improper/Lack of Maintenance
Due 28 March 2004
Resolved 4 February 2005
Documentation › Logs/Records › Oil Record Book
Issued 28 February 2004
Resolved
Update oil record book to include required diagrams, procedures, and oil transfers recorded on vessel's rough log.
Condition: Improper/Lack of Maintenance
Due 28 March 2004
Resolved 21 March 2005
Resolution: Oil record book onboard with entries being made.
Fire Fighting › Firemans Outfit › Lifeline
Issued 28 February 2004
Resolved
Provide appropriate fireman outfits in accordance with 46 CFR 96.35.
Condition: Unknown
Due 28 March 2004
Resolved 4 February 2005
Personnel › Training › Proficiency in Survival Craft
Issued 28 February 2004
Resolved
Provide evidence that the PERSON IN CHARGE has proficiency in liferaft equipment and operation.
Due 28 March 2004
Resolved 4 February 2005
Lifesaving › Inflatable Liferafts › Servicing
Issued 28 February 2004
Resolved
Complete re-servicing of 10 persion Elliot liferaft at a USCG approved servicing facility.
Condition: Improper/Lack of Maintenance
Due 18 April 2004
Resolved 29 April 2004
Construction/Loadline › Penetrations
Issued 11 December 2002
Resolved
Provide ability to make engine room weather tight; seal penetration on main deck into hoist room, provide closure to engine exhaust, seal numerous wire penetrations in hoist room, and redirect engine room supply ventilation to draw from outside source vs. hoist room.
Due 11 March 2003
Resolved 10 March 2003
Resolution: Resolved via fax and digital pictures from vessel rep. [name withheld] dated 10MAR03
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 24 November 2002
Resolved
Hydrostatically test at DOT approved facility or replace 3 CO2 extinguishers LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Due 24 December 2002
Resolved 12 December 2002
Resolution: CLEARED VIA FAX DATED 12DEC02 (SCANNED INTO MISLE DOCUMENTS)
Electrical › Lighting (service) › Lighting Fixture
Issued 24 November 2002
Resolved
Secure/mount exterior lights on stbd aft main deck
Due 24 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL FROM VESSEL REP, [name withheld] DATED 02DEC02 (SCANNED IN MISLE)
Electrical › Lighting (service) › Lighting Fixture
Issued 24 November 2002
Resolved
Secure/mount emergency lights in pump room
Due 24 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL FROM VESSEL REP, [name withheld] DATED 02DEC02 (SCANNED IN MISLE)
Accommodation/Occupational Safety › Occupational Safety
Issued 24 November 2002
Resolved
Replace missing wire courses (rail) along deck edge LEGACY COMPONENT DESC: Deck Rail
Due 24 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL FROM VESSEL REP, [name withheld] DATED 02DEC02 (SCANNED IN MISLE)
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 24 November 2002
Resolved
Mount portable extinguishers in engine room
Due 24 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL FROM VESSEL REP, [name withheld] DATED 02DEC02 (SCANNED IN MISLE)
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 24 November 2002
Resolved
Provide fixed CO2 extinguishing system for paint locker
Due 24 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL FROM VESSEL REP, [name withheld] DATED 02DEC02 (SCANNED IN MISLE)
Lifesaving › Lifebuoys › Stowage
Issued 24 November 2002
Resolved
Mount 2 additional liferings on port and starboard side (total 8)
Due 24 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL FROM VESSEL REP, [name withheld] DATED 02DEC02 (SCANNED IN MISLE)
Lifesaving › Lifebuoys
Issued 24 November 2002
Resolved
Mount starboard forward lifering water light LEGACY COMPONENT DESC: Self-igniting Lights
Due 24 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL FROM VESSEL REP, [name withheld] DATED 02DEC02 (SCANNED IN MISLE)
Fire Fighting › Fire Main
Issued 24 November 2002
Resolved
Replace or repair inoperative fire main relief valve LEGACY COMPONENT DESC: Pressure
Due 24 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL FROM VESSEL REP, [name withheld] DATED 02DEC02 (SCANNED IN MISLE)
Electrical › Electric Supply System (service) › Cable
Issued 24 November 2002
Resolved
Properly repair spliced wiring on port generator
Due 24 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL FROM VESSEL REP, [name withheld] DATED 02DEC02 (SCANNED IN MISLE)
Personnel › Certificates/Documents/Licenses › License, First Assistant Engineer
Issued 24 November 2002
Resolved
Provide person-in-charge designation letter/statement
Due 24 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL FROM VESSEL REP, [name withheld] DATED 02DEC02 (SCANNED IN MISLE)
Communications › Alarms/Indicators › General Alarm
Issued 24 November 2002
Resolved
Label general alarms "GENERAL ALARM-WHEN EMERGENCY ALARM SIGNAL RINGS GO TO YOUR STATION'' in red letters at least ½ inch high.
Due 24 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL FROM VESSEL REP, [name withheld] DATED 02DEC02 (SCANNED IN MISLE)
Construction/Loadline › Structures › Ventilators
Issued 24 November 2002
Resolved
Replace wastage found in port aft ballast ventilation pipe
Due 24 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL FROM VESSEL REP, [name withheld] DATED 02DEC02 (SCANNED IN MISLE)
Construction/Loadline › Structures › Deck Plating
Issued 24 November 2002
Resolved
Crop and renew deck wastage found on starboard forward 01 deck in way of ladderway
Due 24 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL FROM VESSEL REP, [name withheld] DATED 02DEC02 (SCANNED IN MISLE)
Construction/Loadline › Structures
Issued 24 November 2002
Resolved
Crop and renew deck wastage found on port aft 01 deck LEGACY COMPONENT DESC: Deck Plating
Due 24 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL FROM VESSEL REP, [name withheld] DATED 02DEC02 (SCANNED IN MISLE)
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 November 2002
Resolved
Crop and renew wastge found on starboard side ladderway leading to lower main deck pump space (as discussed)
Due 24 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL FROM VESSEL REP, [name withheld] DATED 02DEC02 (SCANNED IN MISLE)
Construction/Loadline › Structures › Transverse Bulkhead
Issued 24 November 2002
Resolved
Crop and renew wasted vertical stiffeners on main deck aft bulkhead
Due 24 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL FROM VESSEL REP, [name withheld] DATED 02DEC02 (SCANNED IN MISLE)
Construction/Loadline › Penetrations
Issued 24 November 2002
Resolved
Crop and renew severe pitting found on port side fuel fill piping LEGACY COMPONENT DESC: Valve Flange
Due 24 December 2002
Resolved 19 December 2002
Resolution: CLEARED VIA E-MAIL WITH PICTURES DATED 19DEC02 FROM VESSEL REP. [name withheld]
Engineering › Diesel Engine (auxiliary)
Issued 7 December 2001
Resolved
Properly repair exhaust system leaks on #2 and # 3 auxiliary diesel engines. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Unknown
Due 7 January 2002
Resolved 13 February 2002
Resolution: Installed new flex couplings and tested sat.
Construction/Loadline
Issued 31 August 1999
Resolved
VESSEL REQUIRED TO UNDERGO DRYDOCK AND INTERNAL STRUCTURAL EXAMINATION.
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Lifesaving
Issued 18 February 1997
Resolved
RESCUE BOAT APPROVED IN LIEU OF TUG REQUIRED ON COI FOR DURATION OF DREDGING OPERATIONS AS LONG AS BTD-55 REMAINS WITHIN DEMARCATION LINE FROM SOUTHWESTERN MOST POINT OF DEMOCRAT POINT ACROSS FIRE ISLAND INLET TO SORE THUMB.
Condition: Unknown
Due 18 February 1997
Resolved 18 February 1997
Construction/Loadline
Issued 17 January 1997
Resolved
PROVIDE MEANS TO DISCHARGE OIL SLOP TANK THROUGH PIPING SYSTEM WITH STANDARD DISCHARGE CONNECTIONS.
Condition: Unknown
Due 17 January 1997
Resolved 17 January 1997
Accommodation/Occupational Safety
Issued 17 January 1997
Resolved
INSTALL POT RAILS AND OVEN LATCH ON GALLEY STOVE.
Condition: Unknown
Due 17 January 1997
Resolved 17 January 1997
Documentation
Issued 17 January 1997
Resolved
PROVIDE CG APPROVED SHIPBOARD OIL POLLUTION EMERGENCY PLAN ON BOARD VESSEL.VESSEL NOT ALLOWED TO CARRY OIL IN ANY FORM ON BOARD BEYOND THE TERRITORIALSEAS UNTIL ITEM IS COMPLETE.
Condition: Unknown
Due 17 January 1997
Resolved 17 January 1997
Fire Fighting
Issued 29 April 1992
Resolved
REMOVE OR PLACE BACK INTO OPERATION FIXED FIREFIGHTING SYSTEM. ALL EXCESS FIREFIGHTING EQUIPMENT CARRIED ABOARD VESSEL MUST BE OF AN APPROVED TYPE, TESTED AT INSPECTIONS, AND KEPT IN GOOD OPERATING CONDITION AND INSPECTED IAW 46 CFR 95.10
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Engineering
Issued 29 April 1992
Resolved
INSTALL AND PROVE PROPER OPERATION OF OILY WATER SEPERATOR(OWS). OWS INSTALLATION MUST BE CG APPROVED IAW 46 CFR 155.410
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Accommodation/Occupational Safety
Issued 11 December 1982
Resolved
REPLACE/RENEW COVER FOR REFRIGERATION UNIT, GALLEY.
Condition: Unknown
Due 11 December 1982
Resolved 11 December 1982
Fire Fighting
Issued 11 December 1982
Resolved
INDENTIFY AND LABEL BY NUMBER ALL FIRE STATIONS.
Condition: Unknown
Due 11 December 1982
Resolved 11 December 1982
Construction/Loadline
Issued 11 December 1982
Resolved
REPAIR/RENEW GANGWAY CHAINS AND WASTED STANCHIONS ON MAIN DECK.
Condition: Unknown
Due 11 December 1982
Resolved 11 December 1982
Electrical
Issued 11 December 1982
Resolved
REPLACE MISSING GLOBES AND GUARDS ON ALL LIGHTING AS REQUIRED.
Condition: Unknown
Due 11 December 1982
Resolved 11 December 1982
Electrical
Issued 11 December 1982
Resolved
DEMONSTRATE EMERGENCY SHUTDOWN/OVERSPEED OF MAIN GENERATOR AND MAIN DREDGE PUMP.
Condition: Unknown
Due 11 December 1982
Resolved 11 December 1982
Deck/Cargo
Issued 11 December 1982
Resolved
PROVIDE CURRENT FMC CERTIFICATE.
Condition: Unknown
Due 11 December 1982
Resolved 11 December 1982
Electrical
Issued 11 December 1982
Resolved
CORRECT LABELING OF EMERGENCY GENERATOR SHUTDOWN.
Condition: Unknown
Due 11 December 1982
Resolved 11 December 1982
Accommodation/Occupational Safety
Issued 11 December 1982
Resolved
BLANK OVER FRESH WATER INTAKE.
Condition: Unknown
Due 11 December 1982
Resolved 11 December 1982
Unknown
Issued 11 December 1982
Resolved
RENEW PIPING TO OUTSIDE AIR RECEIVER AS REQUIRED.
Condition: Unknown
Due 11 December 1982
Resolved 11 December 1982
Deck/Cargo
Issued 11 December 1982
Resolved
CLEAN/OIL FREE ALL BILGES.
Condition: Unknown
Due 11 December 1982
Resolved 11 December 1982
Accommodation/Occupational Safety
Issued 11 December 1982
Resolved
REPAIR BROKEN HANDRAIL, AFT SECTION, LOWER ENGINE ROOM.
Condition: Unknown
Due 11 December 1982
Resolved 11 December 1982
Deck/Cargo
Issued 11 December 1982
Resolved
INSTALL FIXED PIPE FOR OILY BILGE DISCHARGE.
Condition: Unknown
Due 11 December 1982
Resolved 11 December 1982
Lifesaving
Issued 11 December 1982
Resolved
STENCIL RINGBUOYS AS REQUIRED.
Condition: Unknown
Due 11 December 1982
Resolved 11 December 1982
Navigation
Issued 11 December 1982
Resolved
REPAIR SOUND-POWERED PHONE IN SHIP'S OFFICE.
Condition: Unknown
Due 11 December 1982
Resolved 11 December 1982
Construction/Loadline
Issued 11 December 1982
Resolved
REPAIR LATCH ON INSIDE OF PORT AND STARBOARD STACKS.
Condition: Unknown
Due 11 December 1982
Resolved 11 December 1982
Electrical
Issued 11 December 1982
Resolved
REPAIR ELECTRICAL BOXES ABOVE QUARTERS, STERN AREA.
Condition: Unknown
Due 11 December 1982
Resolved 11 December 1982
Unknown
Issued 11 December 1982
Resolved
REPAIR LADDER CAGE ASCENDING SPUD SUPPORTS.
Condition: Unknown
Due 11 December 1982
Resolved 11 December 1982
Deck/Cargo
Issued 11 December 1982
Resolved
CLEAN/REPLACE FLAME SCREENS ON VENT OVER QUARTERS.
Condition: Unknown
Due 11 December 1982
Resolved 11 December 1982
Fire Fighting
Issued 11 December 1982
Resolved
REPAIR FIRE DETECTION THERMAL UNIT ON BULKHEADS IN MAIN QUARTERS.
Condition: Unknown
Due 11 December 1982
Resolved 11 December 1982
Unknown
Issued 11 December 1982
Resolved
REPAIR SOUND POWERED PHONE IN T.V. ROOM.
Condition: Unknown
Due 11 December 1982
Resolved 11 December 1982
Fire Fighting
Issued 11 December 1982
Resolved
SERVICE FIXED FIRE FIGHTING SYSTEM FOR GALLEY HOOD.
Condition: Unknown
Due 11 December 1982
Resolved 11 December 1982
Deck/Cargo
Issued 11 December 1982
Resolved
LABEL ALL DECK VENTS AND FLAME SCREENS AS TO SPACE SERVED.
Condition: Unknown
Due 11 December 1982
Resolved 11 December 1982