MAURY USCG vessel records Sign in
← All vessels

CAPT. ACE

CAPT. ACE is a 1966 offshore supply vessel. The Coast Guard has recorded 46 inspections since 1982, most recently in January 2001, along with 29 deficiencies.

Records from 1982 to 2001. Most recent: inspection, 30 January 2001.

Built
1966
Last inspected
30 January 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WX7413
Flag
UNITED STATES
—
Maury page id
psix-51925

Inspections, by type

…with no type recorded16
Years with a record 19 calendar years (1982–2001)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it65 - Regulatory (Subpart C or D), Net Ton
96 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WX7413MMSI not assigned · expired · compulsorily equipped · granted 24 September 1996, cancelled 20 January 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 46

30 January 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 215330
12 March 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 805845
24 February 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212057
15 April 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1378341
14 March 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1105628
4 February 1998 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390685
1 May 1997 Re-Inspection · Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1378038
3 February 1997 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1103523
24 January 1997 Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1102514
19 January 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 101771
23 August 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 665850
10 July 1996 Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448780
6 July 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 131602
6 July 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212822
13 March 1996 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380418
25 April 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385423
8 June 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1015287
18 April 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409113
24 November 1993 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 844163
13 November 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 145793
1 July 1993 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436780
12 February 1993 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1405354
28 April 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 953814
1 April 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1213492
27 February 1991 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 913686
14 February 1991 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1238011
6 June 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 918110
18 May 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1224392
9 April 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 909850
6 February 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1216358
3 February 1990 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 902879
6 July 1989 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1030575
12 May 1989 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1281582
27 May 1988 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1199811
26 February 1988 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1025424
16 December 1987 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1018409
14 May 1987 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1027637
30 December 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004808
19 June 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 997599
17 December 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 990573
2 July 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1295811
19 June 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 993030
19 June 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282624
15 June 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285146
18 October 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273843
19 August 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966663

Deficiency record · 29

Accommodation/Occupational Safety
Issued 24 January 1997 Resolved
REPAIR DAMAGE TO PILOT HOUSE OF APPROX 8" IN SET TO APPROX 4' HIGH X 8' LONG AREA IN WAY OF 4 WHEEL HOUSE WINDOWS. REPLACE 1 BROKEN WHEELHOUSE WINDOW.
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Construction/Loadline
Issued 24 January 1997 Resolved
CROP/RENEW IN SET PLATING ON TOP OF WHEELHOUSE SET UP APPROX 1" OVER AN AREA OF APPROX 12" X 4'.
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Unknown
Issued 18 May 1990 Resolved
PROVIDE ON BOARD VESSEL DOCDUMENT WITH VALID EXPIRATION STICKER.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Navigation
Issued 18 May 1990 Resolved
REPAIR RUNNINGS SO BULBS ARE IN FOCUS WITH LENS.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Engineering
Issued 18 May 1990 Resolved
REPAIR MAIN ENGINE SHUT DOWNS FROM BRIDGE.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Accommodation/Occupational Safety
Issued 18 May 1990 Resolved
PROVIDE VENT CLOSURE FOR PORT STACK.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Fire Fighting
Issued 18 May 1990 Resolved
DEMONSTRATE PROPER START UP AND OPERATION OF FIRE MONITOR.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Lifesaving
Issued 18 May 1990 Resolved
PROVIDE ON BOARD RESCUE BOAT OR SUITABLE PLATFORM.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Engineering
Issued 18 May 1990 Resolved
STENCIL F.O. SHUT OFF REACH RODS.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Engineering
Issued 6 February 1990 Resolved
INSTALL OVERSPEED TRIPS ON BOTH MAIN ENGINES.
Condition: Unknown
Due 6 February 1990
Resolved 6 February 1990
Navigation
Issued 6 February 1990 Resolved
INSTALL RUDDER ANGLE INDICATORS AT EACH STEERING STATION.
Condition: Unknown
Due 6 February 1990
Resolved 6 February 1990
Navigation
Issued 6 February 1990 Resolved
INSTALL SOUND POWERED PHONES AT STEERING STATIONS, ENGINE ROOM AND GALLEY.
Condition: Unknown
Due 6 February 1990
Resolved 6 February 1990
Unknown
Issued 3 February 1990 Resolved
CROP/RENEW PORT/STBD ENGINEROOM ACCESS TRUNKS AT MAIN DECK CONNECTION TO GOOD METAL.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Unknown
Issued 3 February 1990 Resolved
PROPERLY INSTALL ALL RUNNING LIGHTS AND ANCHOR LIGHTS.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Unknown
Issued 3 February 1990 Resolved
REPLACE MISSING GALLEY FAN VENT HOOD.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Unknown
Issued 3 February 1990 Resolved
FREE UP DECK REACH ROD ON VOID AFAT OF FOREPEAK
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Unknown
Issued 3 February 1990 Resolved
FREE UP ALL DOGS ON WATER TIGHT DOORS AND PROVIDE HOSE TEST.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Unknown
Issued 3 February 1990 Resolved
PROPERLY REWIRE TO JUNCTION BOX GLAND CONNECTION ON CAPSTAN.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Unknown
Issued 3 February 1990 Resolved
PROVIDE DRIP SHIELD FOR CONSTANT VOLT PORT SIDE ENGINEROOM.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Unknown
Issued 3 February 1990 Resolved
PROVIDE GLOBES AND GUARDS AS NECESSARY FOR ALL DECK LIGHTS.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Unknown
Issued 3 February 1990 Resolved
PROPERLY INSTALL CONNECTORS FOR ALL TWISTED WIRE CONNECTIONS ON BRIDGE.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Unknown
Issued 3 February 1990 Resolved
PROVIDE COVER FOR JUNCTION BOX BENEATH BRIDGE CONSOLE.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Unknown
Issued 3 February 1990 Resolved
PROVIDE PROPER WEAK LINK(S) AND PROPER INSTALLATION OF LIFE FLOATS. PERSENT WEAK LINK INCORRECTLY SIZED INSTALLATION INACCEPTABLE.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Unknown
Issued 3 February 1990 Resolved
LINES ARE SEVERELY DETERIATED LIFE FLOAT.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Unknown
Issued 3 February 1990 Resolved
PROVIDE ADDITIONAL FLOATLIGHT FOR LIFERAFT
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Unknown
Issued 3 February 1990 Resolved
REPLACE INOPERABLE FPIRB.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Unknown
Issued 3 February 1990 Resolved
REPLACE AND MAKE OPERABLE MAIN ENGINE TACHOMETERS BOTH PORT AND STBD.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Unknown
Issued 3 February 1990 Resolved
REQUIRE PROPER DECK LIGHT ON TOP OF CABIN (AFT) WITH GIANT NUT FITTING.
Condition: Unknown
Due 3 February 1990
Resolved 3 February 1990
Unknown
Issued 12 May 1989 Resolved
PROVIDE AN ADDITIONAL PORTABLE FIRE EXTINGUISHER TYPE A-II FOR THE QUARTERS/COMMUNICATING CORRIDOR IN ACCORDANCE WITH 46 CFR 95.50-10(A) AND THE VESSEL'S AMENDED CERTIFICATE OF INSPECTION DATED 12MAY89.
Condition: Unknown
Due 12 May 1989
Resolved 12 May 1989

Ownership record