Records from 1981 to 2015. Most recent: operational control imposed, 21 October 2015.
Inspection history · 110
19 October 2015
MTSA/ISPS Verification · COI Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5745766
27 February 2012
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4252165
21 September 2011
Drydock Exam · Internal Structural Exam · Welding Related Inspections Qualification Testing · Examination of Repairs · Annual Inspection · Construction Oversight
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4151096
26 August 2011
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4127551
5 February 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4189432
5 November 2010
Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3924596
27 March 2009
Plan Review (Other than "T")
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3775070
10 March 2009
Welding Related Inspections Qualification Testing · Administrative Inspection · Construction Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3434789
30 September 2008
Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3331203
23 April 2008
Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3190378
17 January 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3132338
1 November 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3106209
26 September 2007
Examination of Repairs · Deficiency Check · Re-Inspection · Administrative Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3066436
9 September 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3053340
20 August 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2763826
1 December 2005
Underwater Inspection in lieu of Drydock
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2546176
8 September 2005
MARPOL Annex I Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2485311
19 April 2005
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2338000
14 January 2005
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2274967
2 December 2004
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2253236
12 October 2004
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2219027
18 January 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1989493
5 June 2003
Plan Review (Other than "T") · Periodic Inspection · Deficiency Check · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1810458
7 April 2003
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1771098
26 March 2003
Underwater Inspection in lieu of Drydock
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1764597
12 March 2003
Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1756444
12 November 2002
Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1704115
22 October 2002
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1698289
22 September 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1678665
8 April 2002
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1602305
2 December 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1076881
28 November 2001
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1076158
22 October 2001
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1075729
16 October 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433896
12 September 2001
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1072321
13 September 2000
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1466182
22 October 1999
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1127558
29 September 1999
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1411979
6 August 1999
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 775713
4 June 1999
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 810389
1 March 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 797822
20 January 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 789243
7 January 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 810213
4 December 1998
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 813104
21 October 1998
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1440069
30 September 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 811137
10 July 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 794967
31 March 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 787864
26 March 1998
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1431981
29 September 1997
Re-Inspection · Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1398773
18 July 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 78557
31 December 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1096876
4 December 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1091167
26 November 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 871815
1 November 1996
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1447642
10 September 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468395
29 February 1996
Deficiency Check · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1363541
8 February 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 877909
29 January 1996
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1407606
29 December 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1185731
24 December 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 26155
30 November 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421049
21 June 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1192446
4 November 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 685444
3 November 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1358599
23 August 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 50921
20 August 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 151035
25 July 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 108173
29 June 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 52754
4 May 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 93185
10 November 1993
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 851266
20 July 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 842176
29 April 1993
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1415841
6 April 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1148550
12 February 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1141444
22 November 1992
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 827721
9 July 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 948102
13 January 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1266001
6 November 1991
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1255557
11 March 1991
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1236678
27 January 1991
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 907003
27 November 1990
Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 899956
19 October 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 901008
19 July 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1221318
3 July 1990
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 905047
16 May 1990
Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1218475
12 April 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 918150
16 January 1990
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 900787
12 December 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1233634
15 May 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1032961
17 March 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1199825
14 December 1988
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1203430
2 December 1988
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1349739
23 June 1988
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 893603
9 March 1988
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1340739
26 January 1988
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1021635
10 August 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1029056
6 March 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1017770
12 February 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1321453
30 December 1986
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1308222
17 July 1986
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1299558
8 August 1985
Credit Drydock
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 983200
12 April 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983770
7 January 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284329
13 October 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1283209
2 July 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 974071
22 April 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965867
7 March 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971649
6 January 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277599
8 January 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964531
Lifesaving › Launching Appliances › Falls
Issued 21 October 2015
No resolution recorded
Lifeboats #1 and #4 (both 53 man) are past due for falls renewal and weight test as per 46 CFR 109.301(j) and are therefore secured and tagged out.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 October 2016 — due date passed with no resolution recorded
Operations/Management › Drills/Instruction › Fire
Issued 8 November 2011
Resolved
Vessel crew must conduct fire and abandon ship drill prior to departing port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2011
Resolution: Crew conducted satisfactory fire and boat drill.
Communications › Audible Communications › SPD (Other)
Issued 8 November 2011
Resolved
Vessel's crew must prove proper operation of the public address/general alarm system.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2011
Resolution: Vessel''''s crew satisfactorily demonstrated the operation of their PA/GA system.
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 8 November 2011
Resolved
Vessel's crew must complete the installation of the emergency lighting on the rig.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2011
Resolution: Vessel''''s E-lighting was fixed to the satisfaction of the attending marine inspector.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 8 November 2011
Resolved
Remove corrosion and wasted metal from jacking gear junction boxes; make all junction boxes watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2012
Resolved 2 July 2012
Resolution: Received documentation and photos showing replacement of wasted metal from junction boxes and made watertight.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Location
Issued 8 November 2011
Resolved
Demonstrate proper operation of newly installed deluge (firefighting) system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2011
Resolution: Crew properly demonstrated operation of the vessel''''s deluge system.
Construction/Loadline › Structures › Superstructure
Issued 8 November 2011
Resolved
Conduct 3rd party survey (ABS) of legs in way of hull once vessel is jack-up off-shore.
Action required: 705 - Other - as specified
Due 1 February 2012
Resolved 5 June 2012
Resolution: Conducted 3rd party survey of legs in way of hull.
Construction/Loadline › Structures › Deck Plating
Issued 5 November 2010
Resolved
Crop and renew wasted deck in pump pit room.
Action required: 705 - Other - as specified
Resolved 30 November 2010
Resolution: Received e-mail from OIM attesting to the completion of repairs.
Construction/Loadline › Penetrations › Valve Flange
Issued 5 November 2010
Resolved
Complete maintenance on all valves and reach rods to ensure proper functioning.
Action required: 705 - Other - as specified
Resolved 30 November 2010
Resolution: Received e-mail from OIM attesting to the completion of repairs.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 5 November 2010
Resolved
Unclog all sounding tubes.
Action required: 705 - Other - as specified
Resolved 30 November 2010
Resolution: Received e-mail from OIM attesting to the completion of repairs.
Construction/Loadline › Penetrations › Pipe Flange
Issued 5 November 2010
Resolved
Crop and renew section of pipeing in pre-load tank P2A.
Action required: 705 - Other - as specified
Resolved 30 November 2010
Resolution: Received e-mail from OIM attesting to the completion of repairs.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2008
Resolved
COMPLETE SEILOD PHASE II or DRYDOCK within 90 days or next rig move. MODU was granted an extention from D8, see documents in vsl detail.
Due 31 December 2008
Resolved 28 September 2009
Resolution: Rcvd supporting documentation from ABS that the Phase II exam has been completed.
Construction/Loadline › Hull › Hull Plating
Issued 1 December 2005
Resolved
Complete Phase 2 of SEILOD at next rig move and prior to 31 Jan 2006.
Condition: Unknown
Due 31 January 2006
Resolved 16 November 2006
Resolution: Received Dive report dated Dec 22, 2005 from U.S. Underwater Services and ABS Report stating no indications.
Lifesaving › Launching Appliances › Falls
Issued 24 January 2005
Resolved
PERFORM WEIGHT TEST ON PORT LIFERAFT DAVIT.
Condition: Unknown
Due 31 January 2005
Resolved 24 January 2005
Resolution: WEIGHT TEST PERFORMED ON DAVIT BY REEL GROUP, INC. RIG FAXED COPY OF REPORT TO PATMS.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 2 December 2004
Resolved
Engine will not start, bad hydraulic accumulator
Due 7 December 2004
Resolved 5 December 2004
Resolution: new accumulator installed
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 13 January 2004
Resolved
Replace and test center overhead (fire) heat sensor in main machinery space. Upon arrival at next location. Letter from OIM to MSSO Brownsville attesting repaired and tested will satisfy. LEGACY COMPONENT DESC: Heat Detectors
Condition: Damaged By Earlier Event
Due 27 January 2004
Resolved 2 December 2004
Communications › Alarms/Indicators › General Alarm
Issued 13 January 2004
Resolved
Replace gas detection sensor in shale shaker room and retest fan failure alarm. Repair and test prior to drilling operations. Letter from OIM to MSSO Brownsville attesting repair and testing complete and satisfactory will satisfy.
Due 27 January 2004
Resolved 2 December 2004
Construction/Loadline › Structures
Issued 26 March 2003
Resolved
Complete Phase II of SEILOD.
Action required: 705 - Other - as specified
Due 26 September 2003
Resolved 13 January 2004
Fire Fighting › Structural - A Class Divisions
Issued 26 March 2003
Resolved
Prove proper operation of fire screen door on 3rd deck leading up stairtower to 4th deck. LEGACY COMPONENT DESC: Fire Screen Door
Action required: 705 - Other - as specified
Due 26 April 2003
Resolved 7 April 2003
Resolution: Received statement from offshore installation manager that fire door had been repaired and is operating properly.
Engineering › Pressure Vessel
Issued 22 October 2002
Resolved
Make all dry bulk and air receivers available for internal examination.
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 13 January 2004
Lifesaving › Launching Appliances
Issued 22 October 2002
Resolved
Renew all lifeboat falls and weight test in accordance with 46 CFR 107.239 (old-Subchapter IA). LEGACY COMPONENT DESC: Falls
Action required: 705 - Other - as specified
Due 22 December 2002
Resolved 31 October 2002
Resolution: Vessel Representative provided copy of COI amendment with correct fall renewal dates. Falls were renewed in March 2001 and weight tested in November 2001.
Lifesaving › Lifeboat
Issued 22 October 2002
Resolved
Renew deteriorated, corroded and frozen safety belts in portand starboard lifeboats. LEGACY COMPONENT DESC: Safety Belt
Action required: 705 - Other - as specified
Due 22 October 2002
Resolved 22 October 2002
Resolution: All frozen safety belts were replaced or repaired.
Engineering › Bilge Water Management System
Issued 22 October 2002
Resolved
Repair or renew frozen bilge valve located in sack room and prove its operable to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 October 2002
Resolved 22 October 2002
Resolution: Valve was disassembled, cleaned and operated properly.
Engineering
Issued 16 October 2001
Resolved
#2 Engine salt water cooling line has a pin hole in it and soft patch. Properly repair or replace section of piping._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Lifesaving
Issued 16 October 2001
Resolved
Conduct weight test on life boat davits, Wire ropes changed 9/01 and required test not done. Test may be witnessed by third party or USCG inspector.
Condition: Unknown
Due 22 October 2001
Resolved 22 October 2001
Lifesaving
Issued 16 October 2001
Resolved
Conduct life raft davit release gear 1.1 weight test or provide documentation test has beed done.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Fire Fighting
Issued 13 September 2000
Resolved
Make permanent repairs to firemain piping at junction of firepump suction from main saltwater supply. Conduct complete survey (visual and gauging) of entire saltwater and firemain pipin systems.
Condition: Unknown
Due 7 November 2000
Resolved 7 November 2000
Construction/Loadline
Issued 29 September 1999
Resolved
REPAIR/RENEW CABLE PENETRATIONS APPROX. (11) LOCATED ON FWD BULKHEAD ON MAIN DECK.
Condition: Unknown
Due 29 September 1999
Resolved 29 September 1999
Lifesaving
Issued 29 September 1999
Resolved
INSTALL EMBARKATION LIGHT FOR STBD SIDE LIFE BOATS.
Condition: Unknown
Due 29 September 1999
Resolved 29 September 1999
Electrical
Issued 29 September 1999
Resolved
LOCATE AND REPAIR LUBE OIL LEAK LOCATED ON TOP OF "V" OF THE NO.1 GENERATORDIESEL DRIVE.
Condition: Unknown
Due 29 September 1999
Resolved 29 September 1999
Lifesaving
Issued 29 September 1999
Resolved
CONDUCT 1.1 LOAD TEST ON FOUR (4) LIFEBOAT RELEASE GEARS, IAW 46 CFR 109.301 (i)(4). TEST TO BE WITNESSED BY CG INSPECTOR.
Condition: Unknown
Due 29 September 1999
Resolved 29 September 1999
Electrical
Issued 4 December 1998
Resolved
TEST REVERSE POWER RELAYS ON ALL GEN SETS AT FIRST AVAILABLE OPPORTUNITY
Condition: Unknown
Due 6 December 1998
Resolved 11 December 1998
Accommodation/Occupational Safety
Issued 4 December 1998
Resolved
PROVE PROPER OPERATION OF FWD PORT ENGINE ROOM VENT FAN.
Condition: Unknown
Due 6 December 1998
Resolved 11 December 1998
Electrical
Issued 4 December 1998
Resolved
PROVE PROPER OPERATION OF OVERSPEED TRIP LIGHT SWITCH ON #2 GENERATOR.
Condition: Unknown
Due 6 December 1998
Resolved 11 December 1998
Fire Fighting
Issued 21 October 1998
Resolved
MISSING NOZZLE CHAIN AT HOSE STATION #8
Condition: Unknown
Due 27 October 1998
Resolved 27 October 1998
Lifesaving
Issued 21 October 1998
Resolved
3 LIFEJACKETS: 1 MISSING LIGHT & 2 MISSING WHISTLES.
Condition: Unknown
Due 27 October 1998
Resolved 27 October 1998
Lifesaving
Issued 21 October 1998
Resolved
TEST LIFERAFT DAVIT HOOK UNDER LOADED CONDITION.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Electrical
Issued 21 October 1998
Resolved
TEST REVERSE POWER RELAY ON ALL GENERATORS, OVERSPEED TRIPS AND LOW L.O. PRESSURE TRIPS ON #2 AND #3 GENERATORS.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Lifesaving
Issued 21 October 1998
Resolved
MAKE PREPARATIONS FOR FIRE/BOAT DRILLS TO BE WITNESSED BY USCG.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Lifesaving
Issued 21 October 1998
Resolved
MARK REMOTE VENT SHUTDOWN SWITCH ON MAIN DECK JUST OUTSIDE MAIN HOUSE AFT SIDE.
Condition: Unknown
Due 27 October 1998
Resolved 27 October 1998
Unknown
Issued 10 July 1998
Resolved
Provide certification of pressure testing on each breathing supply hose with serial numbers 1040 and DW07 prior to commencing dive operations.
Condition: Unknown
Due 11 July 1998
Resolved 21 July 1998
Unknown
Issued 10 July 1998
Resolved
Provide air quality certification on compressor units; serial numbers 20- 325-01, 20-325-02, and 20-325-03. Submit to [name withheld] prior to commencing dive operations.
Condition: Unknown
Due 11 July 1998
Resolved 21 July 1998
Unknown
Issued 10 July 1998
Resolved
Install proper safety relief valve on main volume tank or remove tank from service.
Condition: Unknown
Due 11 July 1998
Resolved 21 July 1998
Unknown
Issued 10 July 1998
Resolved
Calibrate depth gauges and test per 46 CFR 197.458.
Condition: Unknown
Due 11 July 1998
Resolved 21 July 1998
Construction/Loadline
Issued 26 March 1998
Resolved
Complete permanent reapirs to preload tank shell plating and bottom, side and deck stiffeners in accordance with ABS and Coast Guard worklist issued during Phase I (topside portion) of SEILODD on 26MAR98.
Condition: Unknown
Due 26 March 1998
Resolved 26 March 1998
Construction/Loadline
Issued 26 March 1998
Resolved
Conduct Phase II (underwater leg-to-can critical weld connection NDT and diver swim-by) of SEILODD.
Condition: Unknown
Due 26 March 1998
Resolved 26 March 1998
Construction/Loadline
Issued 26 March 1998
Resolved
Prove proper operation of every remote operated valve (bilge suction, preload fill and dump valves, preload equalizing valves, etc.). Must be opoerable by one man without the use of a breaker bar or other leveraging device; replace missing/broken handwheels.
Condition: Unknown
Due 29 June 1998
Resolved 29 June 1998
Construction/Loadline
Issued 26 March 1998
Resolved
Properly clean (wirewheel) valve gate and valve gate seat on every preload tank thru-bulkhead equalizer valve; clean threads and swing hinges on preload tank overboard check valve caps; free-up all overboard check valvesand counterweights._x001C_
Condition: Unknown
Due 29 June 1998
Resolved 29 June 1998
Accommodation/Occupational Safety
Issued 4 December 1996
Resolved
Repipe pressure relief valve inlet piping on #1 and #6 bulk tanks to accomodate the 2 inch diameter relief valves without reduction in piping size (restriction of flow); or submit calculations showing the currently restricted piping has SCFM flow capabilities for output of bulk air compres
Condition: Unknown
Due 4 December 1996
Resolved 4 December 1996
Accommodation/Occupational Safety
Issued 1 November 1996
Resolved
Re-string helo deck perimeter safety netting (guy wire to weave between chain link fence sections) at more freqent intervals.
Condition: Unknown
Due 1 November 1996
Resolved 1 November 1996
Accommodation/Occupational Safety
Issued 1 November 1996
Resolved
Test all rig air receiver and bulk tank (P-tank) relief valves in presence of CG inspector or change out with new or rebuilt relief valves with certification from ASME coded rebuild facility.
Condition: Unknown
Due 1 November 1996
Resolved 1 November 1996
Electrical
Issued 1 November 1996
Resolved
Properly terminate dead-end electrical cable (former welding machine installation location) in a junction box or remove cable all the way back to switchboard or controller.
Condition: Unknown
Due 1 November 1996
Resolved 1 November 1996
Lifesaving
Issued 1 November 1996
Resolved
Provide proper amount of survival drinking water on each lifeboat (3 qts/person/boat).
Condition: Unknown
Due 8 November 1996
Resolved 12 November 1996
Lifesaving
Issued 1 November 1996
Resolved
Renew or replace first aid hoisting litter on stbd side main deck.
Condition: Unknown
Due 1 November 1996
Resolved 1 November 1996
Lifesaving
Issued 1 November 1996
Resolved
Renew liferaft davit cable (falls) and conduct light weight and full loaded(100 percent) weight test in presence of CG inspector.
Condition: Unknown
Due 1 November 1996
Resolved 1 November 1996
Construction/Loadline
Issued 29 January 1996
Resolved
CROP AND RENEW WASTED STIFFENER AROUND CIRCULAR VOID SPACE INSIDE PRELOAD TANK P-6C.
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Electrical
Issued 29 January 1996
Resolved
RENEW WASTED JUNCTION BOX AT ACCESS TO PRELOAD TANK P-7C.
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Construction/Loadline
Issued 29 January 1996
Resolved
CROP AND RENEW UNDERDECK LONGITUDINAL STIFFENERS AS NEEDED IN PRELOAD TANK P-2. PERFORM PLATE THICKNESS GUAGING ON DECK PLATE IN AREA OF WASTED INTERNALS.
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Construction/Loadline
Issued 29 January 1996
Resolved
OPEN AND MAKE READY FOR INSPECITON MUD PIT MASTER DUMP VALVE.
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Construction/Loadline
Issued 29 January 1996
Resolved
RENEW GATE ON DUMP VALVE IN TANK V-10.
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Construction/Loadline
Issued 29 January 1996
Resolved
CROP AND RENEW WASTED ANGLE IRON STIFFENER AT ENTRANCE TO PRELOAD TANK _x001C_ P-4C.
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Construction/Loadline
Issued 29 January 1996
Resolved
REPAIR WELD FRACTURE ON INBOARD GUSSET TO MAIN DECK CONNECTION ON PORT LEG.
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Construction/Loadline
Issued 29 January 1996
Resolved
OPEN AND MAKE READY FOR INSPECTION PRELOAD TANK P-1.
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Construction/Loadline
Issued 29 January 1996
Resolved
PERFORM SPUD CAN CRITICAL CONNECTION INSPECTION AT NEXT RIG MOVE.
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Construction/Loadline
Issued 29 January 1996
Resolved
REPLACE LADDERS IN PRELOAD TANKS P-6D AND P-7C.
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Lifesaving
Issued 30 November 1995
Resolved
PROVIDE SEA ANCHORS FOR ALL LIFEBOATS.
Condition: Unknown
Due 30 November 1995
Resolved 30 November 1995
Lifesaving
Issued 30 November 1995
Resolved
PROVIDE ONBOARD SECOND OXYGEN/EXPLOSIVE GAS DETECTOR.
Condition: Unknown
Due 30 November 1995
Resolved 30 November 1995
Electrical
Issued 30 November 1995
Resolved
PROOF TEST TOTAL RIG SHUTDOWN DEVICE.
Condition: Unknown
Due 30 November 1995
Resolved 30 November 1995
Construction/Loadline
Issued 29 April 1993
Resolved
REPLACE MAIN SEA SUCTION VALVE - 6" GLOBE VALVE_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 April 1993
Resolved 29 April 1993
Construction/Loadline
Issued 29 April 1993
Resolved
CONDUCT LEF TO CAN CONNECITON INSPECTION ON BOW, PORT, STBD LEG AT NEXT RIGMOVE BUT NOT LATER THAN COMPLIANCE DATE IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR._x001C_ _x001C_
Condition: Unknown
Due 29 April 1993
Resolved 29 April 1993
Fire Fighting
Issued 22 November 1992
Resolved
PROVIDE A COPY OF FIRE FIGHTING FOAM ANALYSIS IAW 46 CFR 107.235(b)(2) FOR MUD PIT ROOM FOAM SYSTEM.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Fire Fighting
Issued 22 November 1992
Resolved
PROVE PROPER OPERATION OF A-1 GAS DETECTOR SYSTEM AND LOSS OF VENTILATION ALARM IN SHAKER HOUSE.
Condition: Unknown
Due 22 November 1992
Resolved 22 November 1992
Lifesaving
Issued 22 November 1992
Resolved
PROVIDE PROPER SPRINKLER MODIFICATION ON ALL (4) 28-MAN CAPSULES THAT WOULDBE COMPATABLE WITH INSTALLED SELF RIGHTING KITS IAW 46 CFR 108.503(C).
Condition: Unknown
Due 22 November 1992
Resolved 22 November 1992
Lifesaving
Issued 22 November 1992
Resolved
PROPERLY REPAIR ALL MINOR FIBERGLASS DAMAGE ON ALL (4) SURVIVAL CAPSULES INWAY OF DOORS, DOOR COMBINGS AND STEP MOUNTING SILLS USING APPROVED REPAIR FACILITIES OR PROCEDURES.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Lifesaving
Issued 22 November 1992
Resolved
RENEW/REPLACE (2) MISSING SERVICE LINES FOR LINE THROWING APPLIANCE.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Navigation
Issued 22 November 1992
Resolved
PROPERLY REPAIR FOG HORN TO COMPLY WITH CFR REGULATION AND MANUFACTURERS DBRATING OF 116.9 DB @ 25FT. TO COMPLY WITH CLASS-A AID TO NAVIGATION RATING ASSIGNED TO VESSEL.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Electrical
Issued 22 November 1992
Resolved
RAISE/REMOUNT NON EXPLOSION PROOF LIGHT FIXTURES ON TOP OF DRILL FLOOR WINDWALL TO A MINIMUM OF 5 FEET ABOVE WIND WALL.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Deck/Cargo
Issued 22 November 1992
Resolved
REPLACE/RENEW ALL PRESSURE VESSEL RELIEF VALVES WITH ASME APPROVED RELIEF VALVES AND TEST TO INSURE PROPER RELIEF VALVE SETTINGS (+ - 10%).
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Fire Fighting
Issued 22 November 1992
Resolved
PROVE PROPER OPERATION OF EACH METHANE GAS DETECTOR SENSOR (3 EACH) IN MUD PIT ROOM. (A-1 GAS ALARM).
Condition: Unknown
Due 22 November 1992
Resolved 22 November 1992
Deck/Cargo
Issued 22 November 1992
Resolved
REPLACE/RENEW OUTBOARD HOTWATER HEATER PRESS/TEMP RELIEF VALVE, WITH ASME APPROVED PRESS/TEMP RELIEF VALVE (< 100 PSI/<210 DEGREES F).
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Electrical
Issued 6 November 1991
Resolved
PROVIDE EMERGENCY LIGHTING TO LIGHT LIFEBOATS DOWN TO WATER.
Condition: Unknown
Due 6 December 1991
Resolved 13 January 1992
Electrical
Issued 6 November 1991
Resolved
REPAIR RESET LEVER ON WINCH CONTROLLER FOR LIFEBOAT #1.
Condition: Unknown
Due 6 December 1991
Resolved 13 January 1992
Lifesaving
Issued 6 November 1991
Resolved
PROVIDE BOARDING LADDERS FOR ALL LIFEBOATS.
Condition: Unknown
Due 6 December 1991
Resolved 13 January 1992
Electrical
Issued 27 November 1990
Resolved
RELOCATE OR PROVIDE ADDITIONAL ROTATING BEACON FOR ENGINE ROOM.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Lifesaving
Issued 16 January 1990
Resolved
MAKE PERMANENT REPAIRS TO #2 LIFEBOAT CAPSULE ENGINE.
Condition: Unknown
Due 16 January 1990
Resolved 16 January 1990
Unknown
Issued 15 May 1989
Resolved
PROVIDE APPROVED DRAWINGS AND SATISFY ALL COMMENTS IN ACCORDANCE WITH NVIC 1-82 CHANGE 1 DATED APRIL 1985 FOR THE CHANGES TO THE DRILL FLOOR, DRILL FLOOR SUBSTRUCTURE, ELECTRICAL SYSTEMS INCLUDING LOAD ANALYSIS, EQUIPMENT LISTS AND ONE LINE.
Condition: Unknown
Due 15 May 1989
Resolved 15 May 1989
Fire Fighting
Issued 15 May 1989
Resolved
PROVIDE A COAST GUARD APPROVED FOAM SYSTEM FOR THE MUD PITS. SYSTEM THAT IS INSTALLED IS NOT APPROVED. ELECTRICAL POWER TO THE AGITATORS AND VENT FANS MUST SHUT DOWN UPON ACTIVATION OF THE SYSTEM.
Condition: Unknown
Due 15 May 1989
Resolved 15 May 1989
Unknown
Issued 15 May 1989
Resolved
UNTIL STABILITY CALCULATIONS ARE COMPLETED, THE VARIBLE DECK LOAD CANNOT EXCEED 3196 KIPS. THIS IS A ESTIMATE BASED ON THE EXTRA WEIGHT ON THE DRILL FLOOR AND SUBSTRUCTURE MODIFICATIONS.
Condition: Unknown
Due 15 May 1989
Resolved 15 May 1989
Unknown
Issued 15 May 1989
Resolved
PROVIDE A UPDATED FIRE SAFETY PLAN FOR APPROVAL TO [name withheld], LA.
Condition: Unknown
Due 15 May 1989
Resolved 15 May 1989
Unknown
Issued 15 May 1989
Resolved
PROVIDE A HAZARDOUS LOCATION REVISED DRAWING FOR APPROVAL TO THE [name withheld], LA.
Condition: Unknown
Due 15 May 1989
Resolved 15 May 1989
Construction/Loadline
Issued 26 January 1988
Resolved
REPAIR OR PROVIDE DOCUMENTATION FROM CLASS SOCIETY FOR APPROVAL OF THE TWO THROUGH DECK PENETRATIONS INTO THE MUD PIT ROOM.
Condition: Unknown
Due 26 January 1988
Resolved 26 January 1988
Electrical
Issued 26 January 1988
Resolved
MAKE PROPER PERMANENT REPAIRS TO THE WASTED RAW WATER PIPING THROUGHOUT THEMACHINERY SPACES.
Condition: Unknown
Due 26 January 1988
Resolved 26 January 1988
Construction/Loadline
Issued 26 January 1988
Resolved
MAKE PROPER REPAIRS TO THE WASTED BULKHEAD BETWEEN THE GENERATOR ROOM AND THE MUD PIT ROOM.
Condition: Unknown
Due 26 January 1988
Resolved 26 January 1988
Construction/Loadline
Issued 26 January 1988
Resolved
MAKE PROPER REPAIRS TO THE WASTED BULKHEAD BETWEEN THE MUD PUMP ROOM AND THE MUD PIT ROOM.
Condition: Unknown
Due 26 January 1988
Resolved 26 January 1988
Construction/Loadline
Issued 26 January 1988
Resolved
PROVIDE A GAUGING REPORT FOR THE MUD PUMP ROOM AFT DECK AREA BELOW THE SLOPED DECK.
Condition: Unknown
Due 26 January 1988
Resolved 26 January 1988
Construction/Loadline
Issued 26 January 1988
Resolved
REPLACE THE WASTED UPPER EIGHT FOOT SECTION OF LADDER IN NUMBER SEVEN PRELOAD TANK.
Condition: Unknown
Due 26 January 1988
Resolved 26 January 1988
Fire Fighting
Issued 26 January 1988
Resolved
INSTALL NEW FLANGED 90 DEGREE ELBOW WITH PRESSURE GAUGES ON THE DISCHARGE SIDE OF BOTH FIRE PUMPS.
Condition: Unknown
Due 26 January 1988
Resolved 26 January 1988
Electrical
Issued 26 January 1988
Resolved
CONDUCT TEST OF THE LOW LUBE OIL ALARM FOR THE NUMBER FOUR GENERATOR.
Condition: Unknown
Due 26 January 1988
Resolved 26 January 1988
Construction/Loadline
Issued 26 January 1988
Resolved
MAKE PROPER REPAIRS TO THE WASTED DECK BELOW THE STORAGE TANK LOCATED ABOVETHE DRAW WORKS.
Condition: Unknown
Due 26 January 1988
Resolved 26 January 1988
Electrical
Issued 30 December 1986
Resolved
IN THE PRESENCE OF A MARINE INSPECTOR TEST THE REVERSE POWER RELAYS ON THE MAIN SERVICE GENERATORS.
Condition: Unknown
Due 30 December 1986
Resolved 30 December 1986
Accommodation/Occupational Safety
Issued 30 December 1986
Resolved
MAKE ALL THE AIR RECEIVERS AND THE P-TANKS AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 30 December 1986
Resolved 30 December 1986
Accommodation/Occupational Safety
Issued 30 December 1986
Resolved
PROVIDE A COPY OF THE TEST REPORT FOR ALL THE RELIEF VALVES ON THE AIR RECEIVERS AND THE P-TANKS. THE VALVES MUST HAVE BEEN TESTED IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR TO RECEIVE CREDIT.
Condition: Unknown
Due 30 December 1986
Resolved 30 December 1986
Documentation
Issued 30 December 1986
Resolved
SUBMIT A PHOTOCOPY OF THE CERTIFICATE OF DOCUMENTATION SHOWING THE CORRECT OWNERSHIP DATA TO [name withheld] THE CERTIFICATE OF INSPECTION WILL BEAMENDED UPON RECEIPT.
Condition: Unknown
Due 30 December 1986
Resolved 30 December 1986
Lifesaving
Issued 30 December 1986
Resolved
RENEW THE PROPELLER SHAFT STUFFING BOX ON THE #2 LIFEBOAT.
Condition: Unknown
Due 30 December 1986
Resolved 30 December 1986
Lifesaving
Issued 17 July 1986
Resolved
REPLACE THE FOUR DETERIORATED RING BUOYS WITH FOUR COAST GUARD APPROVED RING BUOYS.
Condition: Unknown
Due 17 July 1986
Resolved 17 July 1986
Lifesaving
Issued 17 July 1986
Resolved
REMOVE THE FOUR UNSERVICABLE 20 MAN CANISTER TYPE LIFERAFTS FROM THE RIG.
Condition: Unknown
Due 17 July 1986
Resolved 17 July 1986
Fire Fighting
Issued 17 July 1986
Resolved
PROVIDE ONE ADDITIONAL LIFELINE FOR THE FIREMAN'S OUTFIT.
Condition: Unknown
Due 17 July 1986
Resolved 17 July 1986
Fire Fighting
Issued 17 July 1986
Resolved
HYDROSTATICALLY TEST THE TWO 150 LB CO2 BOTTLES WHICH ARE LOCATED IN THE MACHINERY SPACE.
Condition: Unknown
Due 17 July 1986
Resolved 17 July 1986
Fire Fighting
Issued 17 July 1986
Resolved
HYDROSTATICALLY TEST THE 150 LB NITROGEN BOTTLE WHICH IS PART OF THE FIXED DRY CHEMICAL SYSTEM LOCATED IN THE COMPRESSOR ROOM.
Condition: Unknown
Due 17 July 1986
Resolved 17 July 1986
Unknown
Issued 12 April 1985
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL, [name withheld], DN566083.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Accommodation/Occupational Safety
Issued 12 April 1985
Resolved
PROVIDE PROPER RELIEF VALVES THAT DO NOT EXCEED THE WORKING PRESSURE OF 40 PSI ON THE P-TANKS 1 THROUGH 6. 46 CFR 54.15-10.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Accommodation/Occupational Safety
Issued 12 April 1985
Resolved
PROVIDE A PROPER RELIEF VALVE THAT DOES NOT EXCEED THE WORKING PRESSURE OF 150 PSI ON AIR COMPRESSOR AIR RECEIVER. 46 CFR 54.15-10.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Electrical
Issued 7 January 1985
Resolved
PROVIDE HEAT RESISTANT GLASS FOR THE DAY TANK SIGHT GLASS. 46CFR58.50-10
Condition: Unknown
Due 7 January 1985
Resolved 7 January 1985
Electrical
Issued 7 January 1985
Resolved
REPAIR AND PROVIDE APPROVED LIGHT BULBS IN THE NAVIGATION LIGHTS. 46CFR111.75-17.
Condition: Unknown
Due 7 January 1985
Resolved 7 January 1985
Unknown
Issued 7 January 1985
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO [name withheld], DN566083.
Condition: Unknown
Due 7 January 1985
Resolved 7 January 1985
Lifesaving
Issued 7 January 1985
Resolved
PROVIDE NEW GASKETS FOR THE DOOR TO THE PAINT LOCKER AND VENT DOOR. 46CFR108.457
Condition: Unknown
Due 7 January 1985
Resolved 7 January 1985
Fire Fighting
Issued 7 January 1985
Resolved
PROVIDE GENERAL ALARM WARNING SIGNS FOR THE ENGINE ROOM,THE HALLIBURTON ROOM,THE FIREPUMP ROOM,THE MOTOR ROOM,THE MUD PIT ROOM, THE SHAKER ROOM ANDTHE DRILL FLOOR, AND THE MAIN DECK. 46CFR108.625.
Condition: Unknown
Due 7 January 1985
Resolved 7 January 1985
Unknown
Issued 7 January 1985
Resolved
PROVIDE RELIEF VALVES RATED AT A LOWER PRESSURE THAN THE RATED PRESSURE OF THE RIGS AIR RECEIVERS. 46CFR54.15-1
Condition: Unknown
Due 7 January 1985
Resolved 7 January 1985
Accommodation/Occupational Safety
Issued 7 January 1985
Resolved
REPAIR ONE INOPERATIVE 3/4 INCH RELIEF VALVE. 46CFR54.15-10
Condition: Unknown
Due 7 January 1985
Resolved 7 January 1985
Electrical
Issued 7 January 1985
Resolved
PROVIDE ADDITIONAL EMERGENCY ESCAPE LIGHTING AT EACH ENTRANCE TO THE GENERATOR ROOM AND ACCESS STAIRS. 46CFR101.231
Condition: Unknown
Due 7 January 1985
Resolved 7 January 1985
Construction/Loadline
Issued 13 October 1984
Resolved
PERFORM NON-DESTRUCTIVE TESTING OF HIGH STRESS AREAS OF LEG TO SPUD CAN CONNECTIONS TO SATISFACTION OF THIS OFFICE AND COGNIZANT OCMI.
Condition: Unknown
Due 13 October 1984
Resolved 13 October 1984
Unknown
Issued 2 July 1984
Resolved
COMPLETE UNDERWATER INSPECTION OF SPUD CANS AND LEGS ON THE NEXT RIG MOVE- MENT.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Unknown
Issued 7 March 1983
Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE VESSEL [name withheld], DN566083.
Condition: Unknown
Due 7 March 1983
Resolved 7 March 1983
Electrical
Issued 7 March 1983
Resolved
PROVIDE AIR PURGING SYSTEM FOR DRILLER'S CONSOLE IN ACCORDANCE WITH NFPA 496, TYPE Z PURGING MAKE CONSOLE AVAILABLE FOR TESTING.
Condition: Unknown
Due 7 March 1983
Resolved 7 March 1983
Electrical
Issued 6 January 1983
Resolved
REPLACE COVER ON CIRCUIT PANEL IN ENGINE ROOM.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Electrical
Issued 6 January 1983
Resolved
PROPERLY SUSPEND WIRES IN ENGINE ROOM OVER LUBE OIL TANK.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Electrical
Issued 6 January 1983
Resolved
REPLACE GUARD OVER EXCITER COUPLING ON EMERGENCY GENERATOR.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Electrical
Issued 6 January 1983
Resolved
REPLACE SCREWS IN COVER PLATES OF EMERGENCY SHUT DOWN SWITCHES AT DRILLER'S CONSOLE.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Unknown
Issued 6 January 1983
Resolved
PROPERLY SUSPEND LOGGING WIRES IN MUD PUMP ROOM AND SACK ROOM.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Construction/Loadline
Issued 6 January 1983
Resolved
REPLACE ALL MISSING DOGS AND HINGE BOLTS AND ADJUST WATERTIGHT DOORS THROUGHOUT RIG AS REQUIRED.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Unknown
Issued 6 January 1983
Resolved
THE FOLLOWING DEFICIENIES PERTAIN TO THE VESSEL [name withheld], DN566083
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Unknown
Issued 6 January 1983
Resolved
REPLACE ALL MISSING PIPE BRACKETS ON MUD LINES IN MUD PUMP ROOM.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Unknown
Issued 6 January 1983
Resolved
MAKE THE FOLLOWING CORRECTIONS IN MUD PITS: REPLACE NON-EXPLOSION PROOF HORN WITH EXPLOSION PROOF TYPE, REPLACE NON-EXPLOSION PROOF LEVEL
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Unknown
Issued 6 January 1983
Resolved
(REQ. 4A CONTINUED) INDICATORS WITH EXPLOSION PROOF TYPE. CROP AND RENEW WASTED CATWALK OVER NO. 3 PIT.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Electrical
Issued 6 January 1983
Resolved
MAKE PERMANENT REPAIRS TO GENERATOR COOLING WATER LINE IN AIR COMPRESSOR ROOM.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Unknown
Issued 6 January 1983
Resolved
MAKE THE FOLLOWING EQUIPMENT AVAILABLE FOR TEST: MUD PUMP RELIEF VALVES, REVERSE POWER RELAYS ON SWITCHBOARD, RIG AIR RECEIVER UNDER FLOOR, AIR
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Unknown
Issued 6 January 1983
Resolved
(REQ. 9A CONTINUED)RECEIVER ON FLOOR AND NB #177072 IN ENGINE ROOM FOR INTERNATIONAL EXAM.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Unknown
Issued 6 January 1983
Resolved
MAKE BILGE PUMP SYSTEM OPERATIONAL.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Fire Fighting
Issued 6 January 1983
Resolved
REPAIR OXYGEN/COMBUSTIBLE GAS METER.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Unknown
Issued 6 January 1983
Resolved
MAKE AVAILABLE FOR TESTING THE ROSS HILL PANEL AIR PURGE INTERLOCK AT THE DRILLER'S CONSOLE.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Unknown
Issued 6 January 1983
Resolved
CONDUCT A FIRE DRILL, ABANDON RIG DRILL AND CHECK ALL GENERAL ALARM BELLS.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Navigation
Issued 6 January 1983
Resolved
REPAIR/REPLACE FIVE LAMP CHANGERS ON FOLLOWING OBSTRUCTION LIGHTS; UPPER & LOWER BOW; UPPER AND LOWER STARBOARD; UPPER PORT.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Electrical
Issued 6 January 1983
Resolved
PROPERLY SEAL AND SUSPEND EXPLOSION PROOF JUNCTION BOX IN POWER LINE SWACO CHOKE.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Lifesaving
Issued 6 January 1983
Resolved
PROVIDE TWO ADDITIONAL PROJECTIVES TO LINE THROWING GUN OUTFIT.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Lifesaving
Issued 6 January 1983
Resolved
PROVIDE 12 PARACHUTE FLARES ABOARD RIG.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Lifesaving
Issued 6 January 1983
Resolved
PROVIDE 500 FEET AUXILIARY LINE FOR LINE THROWING GUN.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Lifesaving
Issued 6 January 1983
Resolved
PROVIDE TO NO. 1 LIFEBOAT: ONE HATCHET, SEA ANCHOR AND ONE HEAVING LINE.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Lifesaving
Issued 6 January 1983
Resolved
PROVIDE A SEA ANCHOR TO NO. 2 LIFEBOAT.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Navigation
Issued 6 January 1983
Resolved
CORRECT TIMING ON FOG HORN TO SOUND FOR 2 SECONDS EVERY 20 SECONDS.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Unknown
Issued 6 January 1983
Resolved
PROVIDE BULBS AND COVERS TO ALL BUNK LIGHTS AS REQUIRED.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Navigation
Issued 6 January 1983
Resolved
CLEAN PORT AND STARBOARD RUNNING LIGHT LENSES AND PAINT SCREENS FLAT BLACK.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Navigation
Issued 6 January 1983
Resolved
PROVIDE STERN LIGHT ABOARD RIG.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Electrical
Issued 6 January 1983
Resolved
PROPERLY MOUNT ELECTRICAL PLUG BOX ON INSIDE OF PAINT LOCKER NEXT TO VENT FAN.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Electrical
Issued 6 January 1983
Resolved
PROPERLY SUSPEND CABLE OUTSIDE PAINT LOCKER AND LABEL PAINT LOCKER VENTILATION FAN SWITCH.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Construction/Loadline
Issued 6 January 1983
Resolved
WELD HAND RAIL COURSE NEXT TO STARBOARD CRANE CONTROL SHACK.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Navigation
Issued 6 January 1983
Resolved
PROVIDE SHIPS BELL ABOARD RIG.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Electrical
Issued 6 January 1983
Resolved
PROPERLY SUSPEND AND ROUTE POWER CABLE ON TOP OF DRILL FLOOR ENCLOSURE.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Electrical
Issued 6 January 1983
Resolved
PROPERLY SUSPEND POWER CABLE NEAR REAR OF DRILL FLOOR ENCLOSURE AND PROPERLY MOUNT JUNCTION BOX ABOVE DRAWWORKS.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983
Electrical
Issued 6 January 1983
Resolved
REPLACE SCREWS IN FACE PLATES OF ELECTRICAL OUTLETS AT REAR OF DRILL FLOOR.
Condition: Unknown
Due 6 January 1983
Resolved 6 January 1983