Records from 1980 to 2025. Most recent: inspection, 15 October 2025.
Inspection history · 75
15 October 2025
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8253190
22 August 2023
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7774014
25 July 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7516234
19 July 2022
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7511018
12 July 2022
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7504408
3 June 2021
Administrative Inspection · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7214260
8 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108372
26 May 2020
Hull Examination · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6960512
23 September 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6795137
11 July 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6473983
22 June 2018
Drydock Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6452630
3 November 2017
Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6302744
19 September 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6270443
16 August 2016
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5974240
28 June 2016
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5921637
20 June 2016
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5913442
13 March 2014
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4814786
5 March 2014
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4809126
27 February 2012
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4250312
19 January 2012
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4227674
13 July 2011
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4080171
25 February 2010
Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3685667
20 July 2009
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3540769
14 April 2009
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3452185
15 October 2008
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3345415
16 April 2008
Annual Inspection · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3185381
2 May 2007
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2922361
17 May 2006
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2651581
12 August 2005
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2460908
22 September 2003
Internal Structural Exam · Examination of Repairs · COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1969214
24 January 2002
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1481187
29 August 2001
Re-Inspection · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1445866
5 June 2000
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427835
30 June 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1411928
22 February 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 130108
15 July 1998
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1437417
31 March 1998
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 786864
10 December 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1114128
9 July 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364237
14 March 1997
Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1095904
26 June 1996
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1425769
28 June 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403970
1 September 1994
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 867834
26 August 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 66786
26 August 1994
Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1465162
5 August 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1178485
22 June 1994
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1450863
6 February 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 163135
10 August 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1472099
23 May 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 32113
1 April 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 164567
1 April 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 665574
25 September 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 185168
12 August 1992
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1445935
6 June 1991
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 934855
28 February 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 929347
28 February 1991
Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1237606
6 February 1991
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1303382
18 June 1990
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 919072
7 June 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 907675
18 July 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1203674
9 June 1989
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1200297
20 January 1989
Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1201170
8 December 1988
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1210662
3 June 1988
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1204368
5 June 1987
COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1310542
13 November 1986
Drydock Extension
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1019973
4 June 1986
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 987880
5 June 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1289881
14 September 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 976869
11 October 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967689
15 September 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969754
12 November 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 971655
12 November 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272895
21 November 1980
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271233
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 September 2023
Resolved
Except as otherwise provided in this section, all vessels shall be provided with not less than two avenues of escape from all general areas accessible to the passengers or where the crew may be quartered or normally employed. Marine Inspector identified the emergency escape from the generator room, engine room, and rudder room were seized and not water tight.
46 CFR 177.15-1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2023
Resolution: Vessel Rep sent video evidence of repaired emergency hatch gasket and actuation handle.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2023
Resolved
All safety and relief valves for use on pressure vessels or piping systems shall be designed to meet the protection and service requirements for which they are intended and shall be set to relief at a pressure that does not exceed the maximum allowable working pressure of the pressure vessel or piping system. Relief valve was set at 190 psi which exceeds the MAWP of 200 psi.
46 CFR 54.15-10(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2023
Resolution: Vessel rep sent photos of relaced safety relief valves with appropriate pressure relief settings.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 19 September 2023
Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. The windings on the generators were coated with oil and dust. Clean windings and identify the source of the oil. Report back to the Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2023
Resolution: Vessel rep sent in photos of cleaned generator windings.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 September 2023
Resolved
Insulations of power fire-pumps, fire-main systems, and fixed fire extinguishing systems on vessels contracted before June 1, 1958 shall meet the requirements of this part insofar as deemed reasonable and practical by the Officer in Charge, Marine Inspection. Marine Inspector identified the pneumatic switch used to discharge the CO2 system was not welded to the bulkhead due to broken welds.
46 CFR 181.01-1(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2023
Resolution: Vessel Rep sent video evidence of repair made to the CO2 system.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 September 2023
Resolved
Electrical equipment and circuits which are a necessary part of any system vital to the safe navigational of the vessel, such as propulsion and steering systems, will be given special consideration and shall be subject to certain additional requirements as determined by the Officer in Charge, Marine Inspections. The vessel’s navigation lights were not on emergency power.
46 CFR 183.01-10(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2023
Resolved 20 September 2023
Resolution: Vessel Rep sent in photo evidence of Nav lights working on emergency power.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 September 2023
Resolved
Except as further modified in this section, where fire extinguishing systems or equipment are not required, but are installed, the system or equipment and its installation shall meet the requirements of this part. Marine Inspector identified the paint locker was not vapor tight preventing the CO2 system from working as intended. The portable fire extinguisher is not required to be hard piped into the paint locker.
46 CFR 181.05-5(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2023
Resolved 20 September 2023
Resolution: Vessel rep sent in photos of the hard piped CO2 system removed from the flame locker.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 September 2023
Resolved
At each initial and subsequent inspection for certification, re-inspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Marine Inspector found several broken guards over glass light fixtures. Must replace guards or install plastic light fixtures.
46 CFR 176.25-50(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2023
Resolved 20 September 2023
Resolution: Vessel rep sent in photos of relaced light globes with plastic covers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 September 2023
Resolved
At each initial and subsequent inspection for certification, re-inspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Hot water heater must drain directly into the bilge.
46 CFR 176.25-50(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2023
Resolved 20 September 2023
Resolution: Vessel rep sent in photo of the hot water heater draining directly into the blige.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 19 September 2023
Resolved
Vessels operated more than 100 nautical miles but not more than 200 nautical miles from the nearest land must:
Be equipped with an MF–DSC radiotelephone transmitter and receiver meeting the requirements of paragraph (a)(2) of this section, and A DSC-capable single sideband radiotelephone meeting the requirements of § 80.1101(c)(4) and capable of operating on all distress and safety frequencies in the medium frequency and high frequency bands listed in § 80.369(a) and (b), on all of the ship-to-shore calling frequencies in the high frequency bands
listed in § 80.369(d), and on at least four of the automated mutual-assistance vessel rescue (AMVER) system HF duplex channels, and be equipped with a NAVTEX receiver conforming to the following performance standards: IMO Resolution A.525(13), as revised by IMO Resolution MSC.148(77) and ITU–R M.540–2. Vessel single sideband radar and NAVTEX was inoperable. Vessel is restricted to operations less than 100 nm from shore until satisfactory repairs are made to the attending Marine Inspector.
47 CFR 80.905(a)(3)(ii)/(iii)(a)/(v)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 6 October 2023
Resolution: Vsl rep provided photo of installed SSR and Tech report of installation.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 19 September 2023
Resolved
The discharge end of vent pipes shall be fitted with removable flame screens. Marine Inspector found wasted flame screens. Vessel must replace all wasted flame screens.
46 CFR 182.20-35(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2023
Resolved 20 September 2023
Resolution: Vessel rep sent photos of all damaged flame screens replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 September 2023
Resolved
At each initial and subsequent inspection for certification, re-inspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Vessel was storing freezer on hatch preventing crew from investigating space in case of a bilge alarm sounding.
46 CFR 176.25-50(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2023
Resolved 20 September 2023
Resolution: Vessel rep sent in photo of corrected def.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 19 September 2023
No resolution recorded
A ship of 100 or more but less than 300 gross tons constructed after June 30, 1974 must have a fixed container or enclosed deck area under or around each fuel or bulk lubricating oil tank vent, or overflow, and fill pipe. Marine Inspector found that the provided containment was damaged and inadequate to hold the discharge of fuel oil. Conduct repairs at next dry dock.
33 CFR 155(b)(1)
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 July 2022
Resolved
Vessel shall be provided with satisfactory arrangement for draining watertight compartments. Pinhole leak found in bilge suction line.
Action required: 10 - Deficiency Rectified
Due 29 July 2022
Resolved 29 July 2022
Resolution: Bile suction line replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 25 July 2022
Resolved
All watertight doors and hatches must be watertight. Adjust all watertight doors and hatches to be watertight.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 July 2022
Resolved 30 July 2022
Resolution: Hatches and Doors adjusted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 July 2022
Resolved
Each portable extinguisher should be free of corrosion and be kept in general good order. Two fire extinguishers found with dry rotted hoses.
Action required: 10 - Deficiency Rectified
Due 29 July 2022
Resolved 29 July 2022
Resolution: Two extinguishers replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 25 July 2022
Resolved
Flexible nonmetallic hose must meet SAE J-1942. Main Oil Pressure and Gear Oil Pressure gauge lines were for air brake service. Not J-1942 approved for current use.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2022
Resolved 30 July 2022
Resolution: Hoses replaced.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 25 July 2022
No resolution recorded
Vessel must comply with radio installation requirements in 47 CFR part 80. Radio installations onboard not matching FCC Safety certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2022 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Compass correction log
Issued 3 June 2021
Resolved
Each vessel must have a current magnetic compass deviation table or graph or compass comparison record for the steering compass, in the wheelhouse. Master could not produce compass deviation table for inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2021
Resolved 23 June 2021
Resolution: Recieved proof of updated compass deviation table.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 3 June 2021
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment. Inspector discovered several temporary repairs made with epoxy to the ballast system piping. 46CFR182.25 (Old T)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2021
Resolved 23 June 2021
Resolution: Tech report provided for replacement piping/permanent repairs.
Construction/Loadline › Hull › Bottom Plating
Issued 6 November 2017
Resolved
Vessel's hull envelope became compromised due to wastage. Vessel failed to notify OCMI when temporary repairs were made and did not return to port to affect permenent repairs for approxiamately 30 days. Vessel must make permanent repairs prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 November 2017
Resolution: Permanent repairs were made and inspected by Coast Guard.
Fire Fighting › Fire Main › Material
Issued 14 April 2009
Resolved
Spanner wrench not attached to fire main. Spanner wrench shall be permanantly attached to fire main IAW 46 CFR 181.15
Action required: 705 - Other - as specified
Due 24 May 2009
Resolved 23 April 2009
Resolution: Permanantly attached spanner wrench to fire main.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 14 April 2009
Resolved
All fuel vent flame screens have heavy corrosion and holes. Flame screens shall be replaced with 20 X 20 mesh flame screens IAW 46 CFR 182.20-35 d.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 May 2009
Resolved 16 April 2009
Resolution: Proper flame screens were installed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 May 2006
Resolved
Vessel original COI missing. Only copy of certificate onboard.
Condition: Unknown
Due 19 June 2006
Resolved 17 May 2006
Resolution: Issued Amended COI to vessel with current information.
Accommodation/Occupational Safety
Issued 29 August 2001
Resolved
Make repairs to fwd toilet to the satisfaction of an attending marine inspector.
Condition: Unknown
Due 2 November 2001
Resolved 24 January 2002
Resolution: Toilet repaired.
Engineering
Issued 26 August 1994
Resolved
EXHAUST PIPING ON #2 MDE SUPPORT BRACKET BROKEN.
Condition: Unknown
Due 2 September 1994
Resolved 16 September 1994
Engineering
Issued 26 August 1994
Resolved
#2 MDE DAMAGED BY FIRE DUE TO POSSIBLE LEAK IN HIGH PRESSURE FUEL LINE.
Condition: Unknown
Due 2 September 1994
Resolved 16 September 1994
Engineering
Issued 26 August 1994
Resolved
GAUGES IN ENGINE ROOM MELTED DURING ENGINE ROOM FIRE.
Condition: Unknown
Due 2 September 1994
Resolved 16 September 1994
Electrical
Issued 26 August 1994
Resolved
NUMEROUS WIRING SYSTEMS DAMAGED BY ENGINE ROOM FIRE.
Condition: Unknown
Due 2 September 1994
Resolved 16 September 1994
Electrical
Issued 26 August 1994
Resolved
LIGHTING FIXTURE GLOBES AND COVERS IN ENGINE ROOM MELTED DUE TO ENGINE ROOMFIRE.
Condition: Unknown
Due 2 September 1994
Resolved 16 September 1994
Electrical
Issued 26 August 1994
Resolved
NUMEROUS ADLE CLAMPS DAMAGED/DESTROYED IN ENGINE ROOM DURING ENGINE ROOM FIRE.
Condition: Unknown
Due 2 September 1994
Resolved 16 September 1994
Accommodation/Occupational Safety
Issued 12 August 1992
Resolved
REROUTE MSD HOLDING TANK VENT TO TERMINATE NO CLOSER THAN 10' FROM ANY COMPARTMENT INTAKE VENT AND PROVIDE FITTED FLAMESCREEN FOR SAME.
Condition: Unknown
Due 11 September 1992
Resolved 28 August 1992
Accommodation/Occupational Safety
Issued 12 August 1992
Resolved
REPAIR/RENEW MSD HOLDING TANK LEVEL INDICATOR IAW 33 CFR 159.83.
Condition: Unknown
Due 11 September 1992
Resolved 28 August 1992
Construction/Loadline
Issued 18 June 1990
Resolved
MAKE REPAIRS TO PORT SIDE, SIDE SHELL FWD OF THE FWD ENIGNE ROOM BULKHEAD. REPAIRS MUST BE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. VSL IS TO REMAIN WITHIN THE MORGAN CITY MARINE INSPECTION LIMITS. NOTIFY OCMI FOR A PERMIT TO PROCEED IF REPAIRS ARE TO BE MADE OUTSIDE THIS ZONE.
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Construction/Loadline
Issued 20 January 1989
Resolved
RENEW PORT INBOARD STRUT AND REINFORCEMENT PLATE AT NEXT CREDIT DRYDOCK.
Condition: Unknown
Due 20 January 1989
Resolved 20 January 1989
Deck/Cargo
Issued 3 June 1988
Resolved
MAKE PERMAMNENT REPAIRS TO THE ELECTRIC MOTOR ON DECK ANCHOR WINCH.
Condition: Unknown
Due 3 June 1988
Resolved 3 June 1988
Unknown
Issued 15 September 1983
Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE VESSEL TIFFANI BRUCE, DN629116.
Condition: Unknown
Due 15 September 1983
Resolved 15 September 1983
Accommodation/Occupational Safety
Issued 15 September 1983
Resolved
REPLACE PLASTIC STOVE VENT PIPING WITH METAL PIPING.
Condition: Unknown
Due 15 September 1983
Resolved 15 September 1983