MAURY USCG vessel records
← All vessels

MS DEE

MS DEE is a 1980 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in October 2025, along with 20 deficiencies — 2 with no resolution recorded —.

Records from 2016 to 2025. Most recent: inspection, 15 October 2025.

Built
1980
Last inspected
15 October 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 October 2025
…with no type recorded2
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC7960
Flag
UNITED STATES
Maury page id
psix-51947

Documentation record

Registered dimensions (L × B × D)117.0 ft × 24.2 ft × 5.8 ft
Registered tonnagegross 97 / net 31
ITC dimensions (L × B × D)117.0 ft × 24.2 ft × 5.8 ft
ITC tonnagegross 185 / net 55
BuilderSWIFTSHIPS INC · MORGAN CITY, LA, UNITED STATES · built 1980
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 29 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
185 - Convention (Subpart B), Gross Ton
31 - Regulatory (Subpart C or D), Net Ton
55 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 16

15 October 2025 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8253190
22 August 2023 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7774014
25 July 2022 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7516234
19 July 2022 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7511018
12 July 2022 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7504408
3 June 2021 Administrative Inspection · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7214260
8 December 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108372
26 May 2020 Hull Examination · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6960512
23 September 2019 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6795137
11 July 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6473983
22 June 2018 Drydock Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6452630
3 November 2017 Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6302744
19 September 2017 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6270443
16 August 2016 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5974240
28 June 2016 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5921637
20 June 2016 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5913442

Deficiency record · 20

07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 September 2023 Resolved
Except as otherwise provided in this section, all vessels shall be provided with not less than two avenues of escape from all general areas accessible to the passengers or where the crew may be quartered or normally employed. Marine Inspector identified the emergency escape from the generator room, engine room, and rudder room were seized and not water tight. 46 CFR 177.15-1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2023
Resolution: Vessel Rep sent video evidence of repaired emergency hatch gasket and actuation handle.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2023 Resolved
All safety and relief valves for use on pressure vessels or piping systems shall be designed to meet the protection and service requirements for which they are intended and shall be set to relief at a pressure that does not exceed the maximum allowable working pressure of the pressure vessel or piping system. Relief valve was set at 190 psi which exceeds the MAWP of 200 psi. 46 CFR 54.15-10(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2023
Resolution: Vessel rep sent photos of relaced safety relief valves with appropriate pressure relief settings.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 19 September 2023 Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. The windings on the generators were coated with oil and dust. Clean windings and identify the source of the oil. Report back to the Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2023
Resolution: Vessel rep sent in photos of cleaned generator windings.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 September 2023 Resolved
Insulations of power fire-pumps, fire-main systems, and fixed fire extinguishing systems on vessels contracted before June 1, 1958 shall meet the requirements of this part insofar as deemed reasonable and practical by the Officer in Charge, Marine Inspection. Marine Inspector identified the pneumatic switch used to discharge the CO2 system was not welded to the bulkhead due to broken welds. 46 CFR 181.01-1(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2023
Resolution: Vessel Rep sent video evidence of repair made to the CO2 system.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 September 2023 Resolved
Electrical equipment and circuits which are a necessary part of any system vital to the safe navigational of the vessel, such as propulsion and steering systems, will be given special consideration and shall be subject to certain additional requirements as determined by the Officer in Charge, Marine Inspections. The vessel’s navigation lights were not on emergency power. 46 CFR 183.01-10(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2023
Resolved 20 September 2023
Resolution: Vessel Rep sent in photo evidence of Nav lights working on emergency power.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 September 2023 Resolved
Except as further modified in this section, where fire extinguishing systems or equipment are not required, but are installed, the system or equipment and its installation shall meet the requirements of this part. Marine Inspector identified the paint locker was not vapor tight preventing the CO2 system from working as intended. The portable fire extinguisher is not required to be hard piped into the paint locker. 46 CFR 181.05-5(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2023
Resolved 20 September 2023
Resolution: Vessel rep sent in photos of the hard piped CO2 system removed from the flame locker.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 September 2023 Resolved
At each initial and subsequent inspection for certification, re-inspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Marine Inspector found several broken guards over glass light fixtures. Must replace guards or install plastic light fixtures. 46 CFR 176.25-50(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2023
Resolved 20 September 2023
Resolution: Vessel rep sent in photos of relaced light globes with plastic covers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 September 2023 Resolved
At each initial and subsequent inspection for certification, re-inspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Hot water heater must drain directly into the bilge. 46 CFR 176.25-50(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2023
Resolved 20 September 2023
Resolution: Vessel rep sent in photo of the hot water heater draining directly into the blige.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 19 September 2023 Resolved
Vessels operated more than 100 nautical miles but not more than 200 nautical miles from the nearest land must: Be equipped with an MF–DSC radiotelephone transmitter and receiver meeting the requirements of paragraph (a)(2) of this section, and A DSC-capable single sideband radiotelephone meeting the requirements of § 80.1101(c)(4) and capable of operating on all distress and safety frequencies in the medium frequency and high frequency bands listed in § 80.369(a) and (b), on all of the ship-to-shore calling frequencies in the high frequency bands listed in § 80.369(d), and on at least four of the automated mutual-assistance vessel rescue (AMVER) system HF duplex channels, and be equipped with a NAVTEX receiver conforming to the following performance standards: IMO Resolution A.525(13), as revised by IMO Resolution MSC.148(77) and ITU–R M.540–2. Vessel single sideband radar and NAVTEX was inoperable. Vessel is restricted to operations less than 100 nm from shore until satisfactory repairs are made to the attending Marine Inspector. 47 CFR 80.905(a)(3)(ii)/(iii)(a)/(v)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 6 October 2023
Resolution: Vsl rep provided photo of installed SSR and Tech report of installation.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 19 September 2023 Resolved
The discharge end of vent pipes shall be fitted with removable flame screens. Marine Inspector found wasted flame screens. Vessel must replace all wasted flame screens. 46 CFR 182.20-35(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2023
Resolved 20 September 2023
Resolution: Vessel rep sent photos of all damaged flame screens replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 September 2023 Resolved
At each initial and subsequent inspection for certification, re-inspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Vessel was storing freezer on hatch preventing crew from investigating space in case of a bilge alarm sounding. 46 CFR 176.25-50(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2023
Resolved 20 September 2023
Resolution: Vessel rep sent in photo of corrected def.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 19 September 2023 No resolution recorded
A ship of 100 or more but less than 300 gross tons constructed after June 30, 1974 must have a fixed container or enclosed deck area under or around each fuel or bulk lubricating oil tank vent, or overflow, and fill pipe. Marine Inspector found that the provided containment was damaged and inadequate to hold the discharge of fuel oil. Conduct repairs at next dry dock. 33 CFR 155(b)(1)
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 July 2022 Resolved
Vessel shall be provided with satisfactory arrangement for draining watertight compartments. Pinhole leak found in bilge suction line.
Action required: 10 - Deficiency Rectified
Due 29 July 2022
Resolved 29 July 2022
Resolution: Bile suction line replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 25 July 2022 Resolved
All watertight doors and hatches must be watertight. Adjust all watertight doors and hatches to be watertight.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 July 2022
Resolved 30 July 2022
Resolution: Hatches and Doors adjusted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 July 2022 Resolved
Each portable extinguisher should be free of corrosion and be kept in general good order. Two fire extinguishers found with dry rotted hoses.
Action required: 10 - Deficiency Rectified
Due 29 July 2022
Resolved 29 July 2022
Resolution: Two extinguishers replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 25 July 2022 Resolved
Flexible nonmetallic hose must meet SAE J-1942. Main Oil Pressure and Gear Oil Pressure gauge lines were for air brake service. Not J-1942 approved for current use.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2022
Resolved 30 July 2022
Resolution: Hoses replaced.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 25 July 2022 No resolution recorded
Vessel must comply with radio installation requirements in 47 CFR part 80. Radio installations onboard not matching FCC Safety certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2022 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Compass correction log
Issued 3 June 2021 Resolved
Each vessel must have a current magnetic compass deviation table or graph or compass comparison record for the steering compass, in the wheelhouse. Master could not produce compass deviation table for inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2021
Resolved 23 June 2021
Resolution: Recieved proof of updated compass deviation table.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 3 June 2021 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment. Inspector discovered several temporary repairs made with epoxy to the ballast system piping. 46CFR182.25 (Old T)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2021
Resolved 23 June 2021
Resolution: Tech report provided for replacement piping/permanent repairs.
Construction/Loadline › Hull › Bottom Plating
Issued 6 November 2017 Resolved
Vessel's hull envelope became compromised due to wastage. Vessel failed to notify OCMI when temporary repairs were made and did not return to port to affect permenent repairs for approxiamately 30 days. Vessel must make permanent repairs prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 November 2017
Resolution: Permanent repairs were made and inspected by Coast Guard.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.