MAURY USCG vessel records Sign in
← All vessels

KITTIWAKE

KITTIWAKE is a 1980 oil recovery. The Coast Guard has recorded 72 inspections since 1980, most recently in May 2026, along with 32 deficiencies.

Records from 1980 to 2026. Most recent: inspection, 29 May 2026.

Built
1980
Last inspected
29 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
366992180, 367147680 (licence lapsed)
Maury page id
psix-51957

Inspections, by type

…with no type recorded14
Years with a record 36 calendar years (1980–2026)
The 72 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)264.0 ft × 50.0 ft × 11.4 ft
Registered tonnagegross 1,259 / net 1,259
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBERGERON SHIPYARD INC · BRAITHWAITE, LA, UNITED STATES · built 1980
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portKODIAK, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 December 2025 · expires 31 December 2026
Service, as the file records itOil Recovery
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1259 - Regulatory (Subpart C or D), Gross Ton
1259 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD4658MMSI 367147680 · cancelled · compulsorily equipped · granted 31 October 2006, cancelled 13 July 2016
WBE8323MMSI 366992180 · expired · voluntarily equipped · granted 6 August 1998, cancelled 20 December 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 72

29 May 2026 Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 8383723
3 October 2025 Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 8245747
20 June 2025 Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 8163340
29 October 2024 Deficiency Check
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 8029590
20 June 2024 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7937066
29 August 2023 Hull Examination · Drydock Exam · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7780716
27 March 2023 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7654690
15 March 2022 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7412572
8 November 2021 Deficiency Check
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7348337
6 August 2021 Administrative Inspection · Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7279357
18 September 2020 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7073568
8 June 2020 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6972556
12 June 2019 Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6724519
8 August 2018 Internal Structural Exam · Cargo Tank Internal · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6504808
8 August 2016 COI Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 5960916
2 August 2016 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5960873
1 October 2010 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3861395
13 April 2009 MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3452025
9 April 2008 Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3180904
24 April 2007 Annual Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2915321
19 May 2006 MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2653645
15 May 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2649687
27 January 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2574477
4 November 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2528174
3 June 2005 Underwater Inspection in lieu of Drydock · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2378464
9 May 2005 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2352990
23 March 2005 Annual Inspection · MTSA Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2317994
25 March 2004 Periodic Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2031379
30 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1999638
2 June 2003 Hull Examination · Cargo Tank Internal · Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1807838
17 March 2003 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1760936
15 April 2002 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1604997
11 April 2001 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1410525
27 June 2000 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1053343
6 April 2000 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1415341
6 April 2000 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1415342
6 May 1999 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1378655
15 April 1998 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1452397
6 April 1998 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1402638
3 April 1997 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1398659
16 April 1996 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1463957
4 April 1995 Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1396267
5 May 1994 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1168554
22 April 1994 Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1400012
21 October 1992 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1391793
10 July 1992 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 946648
27 December 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 959142
30 May 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1218877
11 April 1991 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 936267
15 March 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 922873
15 March 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1234405
15 March 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1306894
4 March 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 920924
6 December 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1230071
26 November 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 924308
24 October 1990 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 911297
2 April 1990 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 906291
20 October 1989 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 538658
2 October 1989 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1317739
1 June 1989 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1351981
28 March 1989 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1194138
18 February 1989 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 441596
19 July 1988 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 523220
23 May 1988 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1353143
16 May 1988 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1349508
23 January 1988 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 509892
27 April 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 491637
27 March 1987 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1324651
4 November 1986 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1013126
1 May 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 995585
14 December 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967620
25 September 1980 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971616

Deficiency record · 32

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 20 June 2024 Resolved
A pressure gauge shall be installed for each pump discharge, and it shall be located at a point visible with respect to the pump controls. Vessel's pressure gauges are out for calibration. 46 CFR 32.50-5
Action required: 705 - Other - as specified
Resolved 29 October 2024
Resolution: Inspected and verified calibration of Gauges.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 20 June 2024 Resolved
During transfer of bulk cargo while fast to a dock, a red signal flag by day shall be placed so that it is visible on all sides. Vessel does not have a red flag. Obtain red flag prior to daytime cargo operations. 46 CFR 35.30-1
Action required: 705 - Other - as specified
Resolved 24 June 2024
Resolution: Red flag has been obtained.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 June 2024 Resolved
All lifesaving appliances and arrangements on tank vessels must be in accordance with subchapter W. Vessel's ring life buoys are becoming non-serviceable. Replace ring life buoys. 46 CFR 31.36-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2024
Resolved 24 June 2024
Resolution: Life rings were replaced.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 28 March 2023 Resolved
A pressure gauge shall be installed for each pump discharge, and it shall be located at a point visible with respect to the pump controls. Vessel's pressure gauges are out for calibration. Prior to using cargo system. 46 CFR 32.50-5.
Action required: 705 - Other - as specified
Resolved 8 May 2023
Resolution: Cargo gauges were calibrated.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 March 2023 Resolved
Approved portable extinguishers must be installed in accordance with table 34.50-10(a) of this section. Vessel currently has 03 40B:C and 01 10B:C extinguishers. Vessel required 04 extinguishers; 02 40B:C for genset and spare extinguisher and an additional 02 for cargo operations. Prior to using cargo system
Action required: 705 - Other - as specified
Resolved 8 May 2023
Resolution: 4th 40 B:C was on board and mounted.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 28 March 2023 Resolved
Each transfer system relief must open at or below the pressure at which it is set to open. For vessels, this shall be tested annually. Vessel has not had their relief valve tested. Prior to using cargo system. 33 CFR 156.170(f)(1)
Action required: 705 - Other - as specified
Resolved 8 May 2023
Resolution: Cargo relief valves were tested and within tolerance.
01 - Certificates & Documentation › 013 - Documents › SOPEP
Issued 27 March 2023 Resolved
Vessel required to maintain SOPEP. Vessel did not have current copy of SOPEP. Provide current copy of SOPEP. 33 CFR 151.09(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2023
Resolved 8 May 2023
Resolution: Vessel had SOPEP on board. Approved through 2027.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 March 2022 Resolved
Approved portable extinguishers must be installed in accordance with table 34.50-10(a) of this section. Vessel currently has 03 40B:C and 01 10B:C extinguishers. Vessel required 04 40B:C extinguishers. 46 CFR 34.50-10(a)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 21 March 2022
Resolution: Vessel has on board the required 04 40B:C extinguishers.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 August 2021 Resolved
Containment must have a mechanical means of closing each drain and scupper in the container. The containment drain plug next to FWD cargo pump would not thread into place. 33 CFR 155.310(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2021
Resolved 24 August 2021
Resolution: Vessel provided proper drain plug.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 6 August 2021 Resolved
A pressure gage shall be installed for each pump discharge, and it shall be located at a point visible with respect to the pump controls. Vessel does not have pressure gages on board. Vessel shall provide a calibrated gage for each cargo pump prior to cargo operations. 46 CFR 32.50-5
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 8 November 2021
Resolution: Vessel had calibrated gauges on each cargo pump.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 August 2021 Resolved
Actions and observations noted in 46 CFR 35.07-10 shall be entered into the vessel's log book. Vessel does not maintain a log book in accordance with 46 CFR 35.07-10(c). 46 CFR 35.07-10
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2021
Resolved 24 August 2021
Resolution: Vessel provided and now maintains an official logbook.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 June 2020 Resolved
Barge does not have a red warning signal to signify transfer of bulk cargo. Provide a red signal (flag by day, and electric lantern at night)that will be visible on all sides while transferring bulk cargo.
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Resolved 9 June 2020
Resolution: Barge provided proper red warning signals.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 8 June 2020 Resolved
Cargo pump pressure gage shall be tested at least once a year for accuracy. Cargo pump gages have not been tested. Have gages tested by a third party to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Resolved 30 June 2020
Resolution: Vessel provided calibration certificates for all cargo pump pressure gauges.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 8 August 2016 Resolved
Vessel required to have SOPEP
Action required: 60 - Rectify deficiencies prior to movement
Due 23 August 2017
Resolved 8 August 2018
Resolution: SOPEP 70571 authorized in Homeport. Approval expires 11/29/2022.
Documentation › Certificates/Documents
Issued 25 March 2004 Resolved
Obtain and carry on board a valid load line certificate.
Condition: Improper/Lack of Maintenance
Due 19 April 2004
Resolved 3 May 2004
Electrical
Issued 6 April 2000 Resolved
PROVIDE PROPER LIGHTING FIXTURES IN ALL HAZARDOUS LOCATIONS OF BARGE IN ACCORDANCE WITH 46 CFR 32.45-1 AND 46 CFR 111.105-31(L).
Condition: Unknown
Due 31 July 2000
Resolved 3 June 2003
Resolution: Corrected.
Construction/Loadline
Issued 6 April 2000 Resolved
MAKE AFT AND AMIDSHIP MACHINERY SPACE HOUSING GASTIGHT IAW 46 CFR 32.60-20.
Condition: Unknown
Due 31 July 2000
Resolved 3 June 2003
Resolution: Corrected.
Unknown
Issued 6 April 2000 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Documentation
Issued 22 April 1994 Resolved
PROVIDE COPIES OF STABILITY LETTER AND LOAD LINE SURVEY.
Condition: Unknown
Due 13 July 1994
Resolved 13 July 1994
Deck/Cargo
Issued 2 April 1990 Resolved
HYDROSTATICALLY TEST ALL DECK CARGO HOSES.
Condition: Unknown
Due 2 April 1990
Resolved 2 April 1990
Deck/Cargo
Issued 2 April 1990 Resolved
REPLACE OR CALIBRATE CARGO PRESSURE GAUGES.
Condition: Unknown
Due 2 April 1990
Resolved 2 April 1990
Deck/Cargo
Issued 2 April 1990 Resolved
HYDROSTATICALLY TEST CARGO DECK PIPING AND RELIEF VALVES.
Condition: Unknown
Due 2 April 1990
Resolved 2 April 1990
Deck/Cargo
Issued 28 March 1989 Resolved
TEST CARGO PIPING RELIEF VALVE.
Condition: Unknown
Due 28 March 1989
Resolved 28 March 1989
Navigation
Issued 28 March 1989 Resolved
STRAIGHTEN PORT RUNNING LIGHT STANCHION.
Condition: Unknown
Due 28 March 1989
Resolved 28 March 1989
Construction/Loadline
Issued 28 March 1989 Resolved
MAKE PROPER REPAIRS TO 12" FRACTURE PORT, AFT CORNER JUST BELOW DECKLINE.
Condition: Unknown
Due 28 March 1989
Resolved 28 March 1989
Electrical
Issued 16 May 1988 Resolved
MAKE OPERABLE LOW LUBE OIL AND OVERSPEED SHUTDOWNS FOR S/S GENERATOR.
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Deck/Cargo
Issued 16 May 1988 Resolved
SEAL STEAM VENTS AS REQUIRED.
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Construction/Loadline
Issued 16 May 1988 Resolved
CROP AND INSERT MAIN DECK BENEATH STBD FOREWARD BITT AS PER CG REGULATIONS.
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Deck/Cargo
Issued 16 May 1988 Resolved
REPLACE FUEL OIL FLEX LINES ON S/S GEN AND BOTH DIESEL CARGO PUMPS WITH CG MARINE APPROVED TYPES.
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Electrical
Issued 16 May 1988 Resolved
REPLACE S/S GENERATOR BATTERY CHARGER WITH APPROVED MARINE ISOLATION TYPE.
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Deck/Cargo
Issued 16 May 1988 Resolved
INSTALL BALL CHECK VALVES ON FUEL OIL TANKS FOR DIESELS.
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Unknown
Issued 14 December 1982 Resolved
DRYDOCK VESSEL AND MAKE AVAILABLE TO A U.S. COAST GUARD INSPECTOR FOR DRY- DOCK EXAM AND CARGO TANK INTERNAL EXAM PRIOR TO PLACING VESSEL IN SERVICE.
Condition: Unknown
Due 14 December 1982
Resolved 14 December 1982

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.