PROVINCETOWN II

PROVINCETOWN II is a 1980 passenger vessel (inspected). The Coast Guard has recorded 110 inspections since 1985, most recently in May 2026, along with 105 deficiencies and 2 casualty investigations between 2013 and 2018.

Records from 1985 to 2026. Most recent: inspection, 28 May 2026.

Built
1980
Last inspected
28 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE2425
Flag
UNITED STATES
367325010
Maury page id
psix-51962

Inspections, by type

…with no type recorded16
Years with a record 41 calendar years (1985–2026)
The 110 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)176.8 ft × 32.0 ft × 7.7 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJAKOBSON SHIPYARD INC · OYSTER BAY, NY, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 9 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE2425MMSI 367325010 · active · compulsorily equipped · granted 16 September 2017, expires 1 December 2027
WYQ8368MMSI not assigned · expired · compulsorily equipped · granted 21 November 1997, cancelled 26 January 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PROVINCETOWN IV Passenger (Inspected) · MISLE 1211168 · 8 September 2018 · activity 6536194

Inspection history · 110

28 May 2026 Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8376427
20 May 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8140448
13 February 2025 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8075003
29 May 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7897601
24 May 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7685167
9 March 2023 Internal Structural Exam · Plan Review (Other than "T") · Examination of Repairs · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7642822
1 August 2022 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7521935
1 March 2022 Deficiency Check · Internal Structural Exam · COI Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7396712
9 October 2021 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7331159
18 May 2021 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7199913
22 December 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7103993
27 August 2020 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7043645
28 May 2020 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6962764
20 March 2020 Drydock Extension
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6929438
1 November 2019 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6847165
11 April 2019 Annual Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6660603
10 September 2018 Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6537102
8 September 2018 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6536194
19 April 2018 MTSA Verification · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6394539
29 March 2018 Internal Structural Exam · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6372477
3 March 2017 COI Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6097245
25 March 2016 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5842960
8 March 2016 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5828970
3 March 2016 MTSA Verification · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5826411
2 August 2015 Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5205140
14 March 2014 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4815978
12 March 2014 MTSA Verification · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4814539
25 January 2012 Drydock Extension
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4231287
19 December 2011 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4210950
16 March 2010 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3696597
19 January 2010 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3663150
2 April 2009 MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3444927
8 May 2008 Annual Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3201981
11 December 2007 Deficiency Check · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3114014
8 November 2007 Internal Structural Exam · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3095180
23 March 2007 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2893498
28 March 2006 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2610903
8 March 2006 Internal Structural Exam · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2598394
29 March 2005 MTSA Verification · Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2322361
9 April 2004 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2040875
1 April 2004 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2034891
22 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1971948
17 July 2003 Administrative Inspection
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1848931
22 June 2003 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1890717
4 June 2003 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1890723
1 June 2003 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1816463
26 March 2003 Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1763664
9 October 2002 Security Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1687194
26 September 2002 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1680509
23 August 2002 Administrative Inspection
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1665377
3 April 2002 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1597713
11 March 2002 Deficiency Check · COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1492730
20 March 2001 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1437881
1 June 2000 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1050005
11 April 2000 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1429323
30 March 2000 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1444301
19 November 1999 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 810510
25 March 1999 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 778843
24 April 1998 Excursion Permit
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1124110
9 April 1998 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 789303
27 March 1998 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 787007
19 March 1998 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 775315
8 August 1997 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 29242
20 July 1997 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 84560
10 June 1997 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1112027
27 March 1997 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1097102
20 March 1997 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1104146
21 June 1996 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 77715
3 May 1996 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1083902
24 April 1996 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1081849
29 March 1996 MARPOL Annex V Examination · COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 884812
3 September 1995 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 179060
7 May 1995 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 69622
21 March 1995 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1132981
9 September 1994 Excursion Permit
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 864462
4 May 1994 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 860268
18 April 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 859991
30 March 1994 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1166817
23 March 1994 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1166128
6 October 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1158642
26 July 1993 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 847310
21 June 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1153931
6 June 1993 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 146427
11 May 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1142037
10 May 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1138781
4 May 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1150299
23 March 1993 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1142152
12 August 1992 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1268089
27 May 1992 Examination of Repairs
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 960211
26 March 1992 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 943585
19 March 1992 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 960333
3 December 1991 Drydock Extension
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1257367
27 November 1991 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1251139
11 April 1991 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1216786
11 April 1991 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1244441
28 March 1991 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 909734
31 October 1990 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 925820
9 May 1990 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 900033
28 March 1990 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 915952
29 March 1989 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1351647
16 March 1989 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1205693
30 March 1988 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1300877
25 March 1988 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1337848
22 April 1987 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1319387
14 April 1987 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1000767
18 March 1987 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1016314
27 March 1986 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 997643
11 March 1986 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1300070
15 March 1985 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1287935
30 January 1985 Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1287647

Deficiency record · 105

07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 20 May 2025 Resolved
Shutoff valves, installed so as to close against the fuel flow must be manually operable from outside the compartment in which the valve is located. The shutoff valves could not be closed during testing without the retrieval of a wrench from another space. Temporary solution was provided by leaving a wrench at each of the two valve shutoff locations. Conduct permanent repairs to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 May 2025
Resolution: Operator fixed valve
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 May 2025 Resolved
Fire extinguishing equipment installed on a vessel in excess of the requirements must be designed, constructed, installed, and maintained in a manner acceptable to the Commandant. The smoke detectors in the engine room and bridge were expired. Replace to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 May 2025
Resolution: Operator replaced smoke detectors.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 May 2025 Resolved
Each item of lifesaving equipment carried on board a vessel but not required under this part, must be of an approved type. The water light on the ring life buoy located on the aft main deck was inoperable. Repair/replace to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 May 2025
Resolution: Operator replaced water light
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 20 May 2025 Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. 01 life float waterlight was cracked. Replace to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 May 2025
Resolution: Operator replaced water light
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 20 May 2025 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Placards were missing from several of the accommodation spaces. Add placards to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 May 2025
Resolution: Operator added appropriate number of placards.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 May 2024 Resolved
At all inspections the attending marine inspector shall ensure that all observed unsafe practices are corrected. 02 electrical junction boxes were found to be missing protective covers. O/O is to repair or replace junction box covers to satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2024
Resolved 26 June 2024
Resolution: Operator installed protective covers
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 May 2024 Resolved
Gauges to indicate engine cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines and located so as to be in the view of the operator. Oil pressure gauges for both main diesel engines at the operating station were inoperable. O/O is to provide working oil pressure gauges at operating station to the satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2024
Resolved 26 June 2024
Resolution: Gauge was replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 29 May 2024 Resolved
Rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crew. Second deck port side mid-ship access fence was torn open causing a potential falling hazard/unsafe condition. O/O is to repair or replace fence rail guard to satisfaction of attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2024
Resolved 26 June 2024
Resolution: Operator repaired rail.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 24 May 2023 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board an FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. EPIRB was found with expired batteries. Vessel is restricted to 3 NM from coastline until fully operational EPIRB is onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2023
Resolved 7 June 2023
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 May 2023 Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. Lube oil and jacket water gauges were found inoperable in the pilot house.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2023
Resolved 7 June 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 May 2023 Resolved
A door in a stair tower, stairway, and main vertical zone bulkhead must be of the self-closing type capable of closing against a 3.5 list of the vessel. One door was found with a broken latch and could not close securely.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2023
Resolved 7 June 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 May 2023 Resolved
A door in a stair tower, stairway, and main vertical zone bulkhead must be of the self-closing type capable of closing against a 3.5 list of the vessel. One door was found unable to securely close.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 May 2023
Resolution: Self-closing devices loosed so door closes completely.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 May 2023 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Each item of equipment carried must be secured properly. One water-light holder was found broken.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 May 2023
Resolution: Water-light holder was replaced with new.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 May 2023 Resolved
Each ring life buoy with a floating water-light must be secured around the body of the ring life buoy. Life ring on the second deck starboard side was found secured to lifeline.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 May 2023
Resolution: Water-light line secured around the body of life-ring.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 May 2023 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in 46CFR164.018 in subchapter Q of this chapter or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). Ring Buoy reflective tape damaged on port pilot house life ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 May 2023
Resolution: Renewed retro-reflective tape.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 May 2023 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. First-aid kit contains multiple expired products.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 May 2023
Resolution: Expired meds replaced with new meds.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 March 2022 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. The forward mast navigation light was inoperable.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2022
Resolved 10 March 2022
Resolution: Operator submitted photo of mast light operational at dusk.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 March 2022 Resolved
A door in a stairtower or stairway must be of the self-closing type capable of closing against a 3.5 list of the vessel. The port side fire door in the forward stairtower on the main deck, was not latching properly.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 1 March 2022
Resolution: Corrected on the spot
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 1 March 2022 Resolved
Each vessel operating on a limited coastwise or lakes, bays and sounds route in cold water, must be provided with life floats of an aggregate capacity that will accommodate at least 100% of person on board. Two of the vessel's buoyant apparatuses were taken out of service. Vessel is restricted to the carriage of 474 total persons when on such routes until replacements have been satisfactorily verified by a marine inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 27 May 2022
Resolution: Operator replaced two out of service bouyant apparatus' with two brand new Life-Floats.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 22 December 2020 Resolved
Provide documentation from Naval Architect that the vertical stiffeners in the wet and dry compartments do not have to be welded to the bottom hull plate or re-weld/weld all that are not welded completely or with cracked welds properly to the bottom hull plate. Snipe back bulkhead stiffeners as per bulkhead stifferner dwg. See attached.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 December 2020
Resolved 18 May 2021
Resolution: Inspected installation of stiffeners as per bulkhead stiffener dwg.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 December 2020 Resolved
Laz port fwd bulkhead, hydraulic line leaking at coupling, steering system. Make repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 December 2020
Resolved 18 May 2021
Resolution: Inspected installation of new piping in affected area in kind, sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 22 December 2020 Resolved
Aft superstructure bulkhead port and starboard corners wasted thru IWO main deck, not weather tight. Make repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 December 2020
Resolved 18 May 2021
Resolution: Cropped/renewed in kind, sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 22 December 2020 Resolved
Starboard fuel/oil containment drain, leaking at union into void space, termination penetrates transverse WT Bulkhead IWO Engine room, need to terminate pipe by welding or install a valve to maintain transverse bulkhead WT integrity.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 December 2020
Resolved 18 May 2021
Resolution: valve and cap, installed and inspected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 December 2020 Resolved
Start air center receiver PRV leaking by replace. Inboard and outboard start air tank pressure gauges not operational, replace or repair.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 December 2020
Resolved 18 May 2021
Resolution: Inspected installation of all 3 pressure vessel releive valves and gauges, sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 December 2020 Resolved
Engine room; Acrylic sight glass on the lube oil tank spliced with plastic hose, valves on tank are not automatic-closing. Replace with glass properly guarded sight glass and self-closing valve assembly.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 December 2020
Resolved 18 May 2021
Resolution: Inspected site glass installation, sat.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 28 May 2020 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, Noted wasted decking and a wasted centerline longitudinal frame underneath the vessels walk in refrigerator. Determine extent of material defect and submit repair proposal to Marine Inspector for approval
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2020
Resolved 18 May 2021
Resolution: replaced in kind; decking and frame.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 March 2020 Resolved
THE INTERVALS BETWEEN DRYDOCK AND INTERNAL STRUCTURAL EXAMINATIONS SPECIFIED IN 46CFR115.600 MAY BE EXTENDED BY THE COGNIZANT OCMI. THE VESSEL IS GRANTED A 7-MONTH EXTENSION OF ITS NEXT CREDIT DRYDOCK EXAM DUE DATE; NEXT CREDIT DRYDOCK EXAM DUE NO LATER THAN OCTOBER 31, 2020.
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 27 August 2020
Resolution: Issued no-sail deficiency to complete credit hull exam prior to carrying passengers.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 September 2018 Resolved
Vsl is broadcasting invalid MMSI and Invalid Call Sign
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 11 September 2018
Resolution: Received e-mail from vsl rep stating vsl information was updated. Checked in VIVS that AIS was broadcasting properly.
Engineering › Bilge Water Management System › Pump
Issued 3 March 2017 Resolved
Vessel rep. had bilge pump out for servicing. Prove proper operation of PTO bilge pump.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 March 2017
Resolution: Rep stated hand valves were repaired and operate properly now. PTO driven fire pump was tested in place SAT 60PSI+, pump was removed and overhauled, reviewed parts list with rep.
Engineering › Pressure Vessel › Shell Plate
Issued 3 March 2017 Resolved
Conduct 1.25 x MAWP hydrostatic test on 03 air receivers.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 15 March 2017
Resolution: All (3) air receivers were pressed up to 350PSI hydro with hand water pump and new 0 - 400PSI installed inline, PSI for 10 minutes, visual inspection of all fittings and welds SAT.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 11 December 2007 Resolved
Provide a list of personnel enrooled in campany drug testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2007
Lifesaving › Buoyant Apparatus › Lifeline
Issued 29 March 2005 Resolved
Replace wasted lifelines and painters as needed on all lifefloats and buoyant apparatus.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 8 April 2005
Resolution: All lifelines and painters replaced as needed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 March 2005 Resolved
Repair wire mesh between handrail courses on the portside, aft.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 8 April 2005
Resolution: Frame of the wire mesh rewelded to the fore and aft stanchions.
Deck/Cargo › Holds/Tanks › Scuttle
Issued 29 March 2005 Resolved
Provide retaining device for the forward scuttle cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 29 March 2005
Resolution: Retaining device installed
Navigation › Collision/Grounding Avoidance
Issued 26 March 2003 Resolved
Provide documentation that the vessels navigation light meet UL standard 1104 or install navigation lights that meet UL standard 1104. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 July 2003
Resolved 24 June 2003
Lifesaving › Buoyant Apparatus
Issued 11 March 2002 Resolved
Renew pendants on 2 buoyant apparatus. LEGACY COMPONENT DESC: pendants
Action required: 705 - Other - as specified
Due 23 March 2002
Resolved 23 March 2002
Resolution: Renewed pendants on 2 buoyant apparatus.
Lifesaving › Lifebuoys
Issued 11 March 2002 Resolved
Renew pendants on 2 liferings
Action required: 705 - Other - as specified
Due 23 March 2002
Resolved 23 March 2002
Resolution: Renewed pendants on 2 liferings.
Engineering
Issued 11 March 2002 Resolved
Provide proper penetration on Fwd bulkhead of AFT storeroom to greywater line. LEGACY COMPONENT DESC: greywater line
Action required: 705 - Other - as specified
Due 23 March 2002
Resolved 23 March 2002
Resolution: Changed penetration on Fwd bulkhead in AFT storeroom to a steel greywater line.
Electrical
Issued 20 March 2001 Resolved
BURNED ELECTRICAL OUTLET IN ENGINE ROOM.
Condition: Unknown
Due 20 March 2001
Resolved 5 April 2001
Lifesaving
Issued 20 March 2001 Resolved
REMOVE TAPE FROM BUOYANT APPARATUS PAINTER LINES TAPED TO THE RAILS.
Condition: Unknown
Due 20 March 2001
Resolved 5 April 2001
Documentation
Issued 30 March 2000 Resolved
VESSEL SHALL SUBMIT PLANS FOR NEW ENGINEROOM SEACHEST TO G-MSC AND RESOLVE ALL OUTSTANDING COMMENTS AS REQUIRED BY 46 CFR 116.202(a)(10) & (11) RESPECTIVELY.
Condition: Unknown
Due 30 March 2000
Resolved 30 March 2000
Engineering
Issued 19 March 1998 Resolved
INSTALL GUARDS OVER ROTATING AXLES ON FWD, LEFT SIDE OF EACH MDE.
Condition: Unknown
Due 27 March 1998
Resolved 30 March 1998
Fire Fighting
Issued 19 March 1998 Resolved
LABEL EMERGENCY FUEL SHUT OFF VALVES IN STBD HEAD.
Condition: Unknown
Due 27 March 1998
Resolved 30 March 1998
Lifesaving
Issued 19 March 1998 Resolved
CLEAN ALL PFDs AND MAKE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 27 March 1998
Resolved 30 March 1998
Fire Fighting
Issued 19 March 1998 Resolved
REPAIR LATCH ON STBD FORWARD FIRE DOOR ON MAIN DECK.
Condition: Unknown
Due 27 March 1998
Resolved 30 March 1998
Accommodation/Occupational Safety
Issued 19 March 1998 Resolved
RENEW LABEL FOR ENGINEROOM EMERGENCY ESCAPE HATCH.
Condition: Unknown
Due 27 March 1998
Resolved 30 March 1998
Lifesaving
Issued 19 March 1998 Resolved
PROVIDE PROOF OF COMPLIANCE WITH CHEMICAL TESTING PROGRAM.
Condition: Unknown
Due 27 March 1998
Resolved 30 March 1998
Lifesaving
Issued 27 March 1997 Resolved
Provide distress signal container of a bright color, and clearly mark in legible contrasting colors 1/2" high "DISTRESS SIGNALS" IAW 46CFR 185.614.
Condition: Unknown
Due 3 April 1997
Resolved 18 April 1997
Engineering
Issued 27 March 1997 Resolved
RENEW/REPAIR DEFECTIVE AIR RECEIVER RELIEF VALVE AND HYDRO TEST AIR RECEIVERS AT 1 1/4 X MAWP = 312 1/2 PSI.
Condition: Unknown
Due 7 April 1997
Resolved 18 April 1997
Lifesaving
Issued 27 March 1997 Resolved
CLEAN BUOYANT APPARATUS, REPAIR/RENEW BUOYANT APPARATUS IDENTIFIED WITH DETERIORATED PENDANTS AND LIFELINE WEBBING. PROVIDE ALL BOUYANT APPARATUS WITH RETRO-REFLECTIVE TAPE AS REQUIRED BY IMO RES. A658(16).
Condition: Unknown
Due 7 April 1997
Resolved 18 April 1997
Fire Fighting
Issued 20 March 1997 Resolved
PROVIDE A REMOTE VENTILATION SHUT DOWN FOR THE NEW GALLEY RANGE VENT SYSTEMIN THE PILOT HOUSE.
Condition: Unknown
Due 27 March 1997
Resolved 13 May 1997
Fire Fighting
Issued 20 March 1997 Resolved
PROVIDE COPY OF GALLEY RANGE HOOD FIRE EXTINGUISHING SYSTEM INSTALLATION CERTIFICATES.
Condition: Unknown
Due 27 March 1997
Resolved 13 May 1997
Fire Fighting
Issued 20 March 1997 Resolved
TEST THE GALLEY RANGE HOOD FIRE EXTINGUISHING SYSTEM IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 27 March 1997
Resolved 13 May 1997
Construction/Loadline
Issued 29 March 1996 Resolved
FREE-UP AND PROVE PROPER OPERATION OF ALL THROUGH HULL VALVES IN THE ENGINEROOM.
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Construction/Loadline
Issued 29 March 1996 Resolved
PROVIDE MEANS TO OPEN EMERGENCY ESCAPE HATCH IN ENGINE ROOM.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Fire Fighting
Issued 29 March 1996 Resolved
FREE-UP GATE VALVE TO FIREFIGHTING STATION ON DECK DECK PORT SIDE.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Lifesaving
Issued 29 March 1996 Resolved
INSTALL PROPER TYPE OF WEAK LINK TO BOTH BUOYANT APPARATUS SEA PAINTER LINES.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Lifesaving
Issued 29 March 1996 Resolved
RENEW 4 MALFUNCTIONING WATERLIGHTS FOR B/A.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Accommodation/Occupational Safety
Issued 29 March 1996 Resolved
PROVIDE AND INSTALL APPROVED PIPING TO SANITARY FEED LINE IN THE ENGINE ROOM.
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Deck/Cargo
Issued 29 March 1996 Resolved
PROVIDE PROCEDURES TO EFFECTIVELY AND SAFELY DEPLOY VESSEL'S 300 LB ANCHOR.
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Accommodation/Occupational Safety
Issued 29 March 1996 Resolved
PROVIDE AND INSTALL APPROVED PIPING TO SALT WATER PRESSURE TANK IN THE ENGINE ROOM.
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Fire Fighting
Issued 29 March 1996 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, AND NO LATER THAN 26 MARCH 96, SHOW PROPER WEIGHTS OF ALL CO2 CYLINDERS IN THE PRESENCE OF A COAST GUARD MARINEINSPECTOR.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Fire Fighting
Issued 29 March 1996 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, AND NO LATER THAN 01 APRIL 96, HYDROTEST, RECHARGE AND PROPERLY INSTALL C02 CYLINDER THAT WEIGHED LIGHT.
Condition: Unknown
Due 29 March 1996
Resolved 11 April 1996
Electrical
Issued 29 March 1996 Resolved
PROPERLY MOUNT ELECTRICAL BOX ON AFT BULKHEAD IN THE ENGINE ROOM AND REMOVEALL TEMPORARY EXTENSION CORDS.
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Lifesaving
Issued 29 March 1996 Resolved
RENEW 2 B/A WATERLIGHT BATTERIES WHERE DEAD.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Lifesaving
Issued 29 March 1996 Resolved
PROPERLY SECURE WATERLIGHT TO B/A WHERE DISCONNECTED.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Construction/Loadline
Issued 29 March 1996 Resolved
PROPERLY CONNECT FLEXIBLE HOSE PIECE FOR DECK DRAIN IN FORWARD STORE ROOM COMPARTMENT.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Lifesaving
Issued 29 March 1996 Resolved
RENEW IN KIND, ROTTED PENDANT LINE TO AFTERMOST BUOYANT APPARATUS.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Lifesaving
Issued 29 March 1996 Resolved
CLEAN ALL DIRTY AND SOILED ADULT AND CHILD LIFEJACKETS BEFORE RE-STOWING.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Electrical
Issued 29 March 1996 Resolved
PROPERLY LABEL CIRCUIT BREAKERS ON ENGINE ROOM PANELBOARD AND PROVIDE FRONTPANEL.
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Fire Fighting
Issued 29 March 1996 Resolved
PROPERLY MOUNT BII HAND PORTABLE FIRE EXTINGUISHER BRACKET IN CREW ACCOMMODATION SPACE.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Documentation
Issued 29 March 1996 Resolved
PROVIDE MOST RECENT EDITION OF RULES OF THE ROAD PUBLICATION ON BRIDGE.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Fire Fighting
Issued 29 March 1996 Resolved
PROPERLY LABEL FIREFIGHTING STATION ON DOOR TO ACCOMMODATION SPACE FF STATION.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Fire Fighting
Issued 29 March 1996 Resolved
PROVIDE ADEQUATE LIGHTING IN ACCOMMODATION SPACE FOR FIRESTATION.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Fire Fighting
Issued 29 March 1996 Resolved
PLACE LABEL FOR FIREFIGHTING STATION ON UPPERMOST DECK PORT SIDE.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Fire Fighting
Issued 29 March 1996 Resolved
PROVIDE A SPANNER WRENCH FOR EACH FIREFIGHTING STATION ON BOARD VESSEL.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Electrical
Issued 29 March 1996 Resolved
PROPERLY SPLICE/CONNECT WIRING THROUGHOUT VESSEL WHERE FITTED WITH UNAPPROVED WIRE NUT CONNECITONS.
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Electrical
Issued 29 March 1996 Resolved
PROPERLY SECURE AND MOUNT ELECTRICAL CABLE LEADS FROM BATTERIES TO GENERATORS IN ENGINE ROOM.
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Fire Fighting
Issued 23 March 1994 Resolved
PROVE PROPER OPERATION OF FIRE PUMP GUAGES.
Condition: Unknown
Due 23 April 1994
Resolved 28 March 1994
Accommodation/Occupational Safety
Issued 23 March 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE PROVE PROPER OPERATION OF ALL TOILETSAND WASH BASINS.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Construction/Loadline
Issued 23 March 1994 Resolved
REPLACE BILGE SUCTION STRAINER IN FORWARD STOREROOM.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Accommodation/Occupational Safety
Issued 26 July 1993 Resolved
IN ACCORDANCE WITH 46 CFR 171.119, 46 CFR 171.124 INSTALL DEADLIGHT COVERS FOR THE FORWARD FOUR (4) PORT AND STARBOARD MAIN DECK WINDOWS TO THE SATISFACTION OF AN ATTENDING U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 26 July 1993
Resolved 26 July 1993
Navigation
Issued 4 May 1993 Resolved
PRIOR TO PLACING VESSEL IN SERVICE ENSURE NAVIGATIONAL RUNNING LIGHT ARRANGEMENT CONFORMS WITH ANNEX 1, NAVIGATIONAL RULES OF THE ROAD. NEW ARRANGEMENT TO BE EXAMINED BY AN ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 15 May 1993
Resolved 10 May 1993
Fire Fighting
Issued 23 March 1993 Resolved
PRIOR TO PLACING VESSEL IN SERVICE WITH PASSENGERS LABEL FIXED CO2 SYSTEM IN ACCORDANCE WITH 46 CFR 181.20-15 TO THE SATISFACTION OF AN ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Fire Fighting
Issued 23 March 1993 Resolved
PRIOR TO PLACING VESSEL IN SERVICE WITH PASSENGERS PROVE PROPER OPERATION OF FIXED CO2 SYSTEM TIME DELAY AND MAIN VALVE TO THE SATISFACTION OF AN ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Fire Fighting
Issued 23 March 1993 Resolved
PRIOR TO PLACING VESSEL IN SERVICE WITH PASSENGERS REMOVE DOOR LATCHES FROMALL FIRE SCREEN DOORS TO THE SATISFACTION OF AN ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Electrical
Issued 23 March 1993 Resolved
PROVIDE AN APPROVED ELECTRICAL MAT IN VICINITY OF SWITCH BOARD IN ACCORDANCE WITH 46 CFR 183.10-15.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Fire Fighting
Issued 23 March 1993 Resolved
REPAIR AND PROVE PROPER OPERATION OF FIRE PUMP PRESSURE GAUGES TO THE SATISFACTION OF AN ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Unknown
Issued 23 March 1993 Resolved
THE MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODING,LOSS OF PROPULSION, AND ABANDON SHIP WITH ALL NORMALLY ASSIGNED VESSEL CREWMEMBERS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Fire Fighting
Issued 23 March 1993 Resolved
LABEL EMERGENCY ESCAPE TO ENGINE ROOM IN ACCORDANCE WITH 46 CFR 185.30-15 TO THE SATISFACTION OF AN ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Unknown
Issued 23 March 1993 Resolved
PRIOR TO CARRYING PASSENGERS THE MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODING, LOSS OF PROPULSION, AND ABANDON SHIP WITH ALL NORMALLY ASSIGNED VESSEL CREWMEMBERS.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Documentation
Issued 23 March 1993 Resolved
PRIOR TO OPERATING MORE THAN 1000 FEET FROM LAND PROVIDE PROOF OF A CURRENTFCC RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Navigation
Issued 23 March 1993 Resolved
ARRANGE NAVIGATIONAL RUNNING LIGHTS TO CONFORM WITH ANNEX 1 NAVIGATIONAL RULES OF THE ROADS TO THE SATISFACTION OF AN ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Fire Fighting
Issued 26 March 1992 Resolved
PROVE PROPER OPERATION OF AUTOMATIC FIRE SCREEN DOOR CLOSURES PRIOR TO CARRYING PASSENGERS FOR HIRE
Condition: Unknown
Due 7 April 1992
Resolved 7 April 1992
Unknown
Issued 28 March 1991 Resolved
PRESSURE VESSELS DUE FOR INTERNAL EXAMINATION. VESSEL OPERATOR UNABLE AT TIME OF INSPECTION TO REMOVE PLUGS FOR EXAM. MAKE ALL PRESSUE VESSELS AVAILABLE FOR INTERNAL EXAM OR 1 1/4 HYDROSTATIC TEST PRIOR TO 9 APR 1991.
Condition: Unknown
Due 28 March 1991
Resolved 28 March 1991
Electrical
Issued 28 March 1990 Resolved
INSTALL TEMPORARY CEMENT PATCH TO GENERATOR KEEL COOLER OUTLET THRU HULL FITTING. VESSEL MUST BE DRY DOCKED AND PERMANENT REPARIS MADE PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 28 March 1990
Resolved 28 March 1990
Lifesaving
Issued 16 March 1989 Resolved
BECKECTON RING BOUY BROKEN. MAKE SUITABLE REPAIR TO BOUY OR RENEW BOUY WITH US COAST GUARD APPROVED BOUY.
Condition: Unknown
Due 16 March 1989
Resolved 16 March 1989
Fire Fighting
Issued 16 March 1989 Resolved
SERVICE ENGINEROOM FIXED CO2 SYSTEM
Condition: Unknown
Due 16 March 1989
Resolved 16 March 1989
Fire Fighting
Issued 25 March 1988 Resolved
THE TWO AFT FIRE DOORS ARE NOT OPERATIONAL.
Condition: Unknown
Due 25 March 1988
Resolved 25 March 1988
Accommodation/Occupational Safety
Issued 25 March 1988 Resolved
HYDROSTATICLY TEST OR OPEN FOR INSPECTION ALL PRESSURE VESSELS ON BOARD THEVESSELIN THE PRESENCE OF A CCCOAST GUARD INSPECTOR.
Condition: Unknown
Due 25 March 1988
Resolved 25 March 1988
Lifesaving
Issued 25 March 1988 Resolved
HAND LINES ON LIFE FLOATS ARE ROTTEN, RENEW IN KIND.
Condition: Unknown
Due 25 March 1988
Resolved 25 March 1988
Fire Fighting
Issued 25 March 1988 Resolved
WIEGH FIXED CO2 CYLINDERS.
Condition: Unknown
Due 25 March 1988
Resolved 25 March 1988
Fire Fighting
Issued 11 March 1986 Resolved
REPAIR AUTOMATIC SWITCH FOR 3 FIRE DOORS ON THE MAIN DECK
Condition: Unknown
Due 11 March 1986
Resolved 11 March 1986
Fire Fighting
Issued 11 March 1986 Resolved
TEST FIXED FIRE EXTINGUISHING SYSTEM
Condition: Unknown
Due 11 March 1986
Resolved 11 March 1986
Fire Fighting
Issued 11 March 1986 Resolved
MAKE REPAIRS TO COAMING AT STAIRWAY LEADING TO SECOND DECK AT 3 LOCATIONS
Condition: Unknown
Due 11 March 1986
Resolved 11 March 1986

Casualty record · 2

28 July 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 4670499
8 September 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 6536194
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.