Inspection history · 19
25 June 2026
Administrative Inspection · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8413861
20 January 2026
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8300027
19 June 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8165678
7 March 2024
COI Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7875616
28 February 2024
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7871464
29 January 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7857126
16 August 2023
Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7769535
20 July 2023
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7747516
1 February 2023
Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7630430
14 July 2022
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7506303
1 February 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7388807
20 July 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7256338
21 July 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7010188
16 March 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6925988
18 April 2019
DAPI Audit · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6665070
8 March 2018
DAPI Audit · Hull Examination · Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6368064
16 May 2017
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6144903
29 April 2016
Deficiency Check · Internal Structural Exam · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5865012
18 March 2016
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5835810
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 June 2026
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel missed annual inspection window. Vessel must undergo a COI Inspection prior to the carriage of passengers.
46 CFR 176.500(b)(1)
701c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2026
Resolution: Vessel had COI inspection, new anniversary date on the COI.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 June 2025
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel missed annual inspection window. Vessel must undergo a COI Inspection prior to the carriage of passengers.
46 CFR 176.500(b)(1)
701c
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 June 2025
Resolved 25 June 2025
Resolution: Completed annual inspection. Cleared outstanding def.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 7 March 2024
Resolved
Vessel had expired radiotelephone certificate. Vessel is restricted to 1NM operations until valid certificate is issued.
46 CFR 184.520
47 CFR 80.903
Action required: 705 - Other - as specified
Resolved 23 March 2024
Resolution: Received a FCC Radiotelephony Certificate issued 23MAR2024 and expires 23MAR2029.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 14 July 2022
Resolved
A vsl must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission. Vessel certificated Oceans Route and was operating over 20 nm from shore with no installed and certificated MF radio onboard. Install and have MF radio certificated by FCC.
Action required: 705 - Other - as specified
Due 14 July 2022
Resolved 20 July 2023
Resolution: USCG no longer monitors MF frequencies. Vessel has satellite phone as well.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 July 2022
Resolved
Abandon ship, man overboard drills, training shall be logged or otherwise documented for review by the CG upon request. The drill entry shall include the ff info: 1) Date of the drill and training; and (2) General description of the drill scenario and training topics. No records of required emergency drills were recorded and available during inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2022
Resolved 28 July 2022
Resolution: Received documents from Master with regards to documentation for required drills, all sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 July 2022
Resolved
The EPIRB test required shall be logged or otherwise documented, as applicable. No records of required EPIRB testing were available during inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2022
Resolved 28 July 2022
Resolution: Received documents from Master with regards to documentation for EPIRB monthly test, all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 July 2022
Resolved
Each package shall be enclosed in a jacket of tough, transparent material, properly sealed, which shall meet the watertight requirements. Carton & contents shall conform to the requirements of Federal Specification. Replace broken & incomplete First Aid kit onboard.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2022
Resolved 28 July 2022
Resolution: Received photo documentation that master bought new First aid kit, all sat.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 14 July 2022
Resolved
The operator must secure each Type III device in a manner which prevents discharge of sewage through an acceptable methods of securing the device. The macerator pump does not comply with Type II MSD requirements and MSD is therefore considered Type III. Although the current installation of the pump preclude the vessel from discharging the effluent on the side without turning the pump "on", Environmental Protection Agency requires that all valve leading to an overboard discharge was secured. During the inspection, the discharge valve was left in the "open" position. Note that in order to access the valve, one must open the hatch located at the operator station first. Below are acceptable methods of securing the device:
(1) Closing each valve leading to an overboard discharge and removing the handle; (2) Padlocking each valve leading to an overboard discharge in the closed position; or (3) Using a non-releasable wire-tie to hold each valve leading to an overboard discharge in the closed position.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2022
Resolved 8 August 2022
Resolution: Master provided photo evidence that MSD Type III meets the requirement for securing the device.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 20 July 2021
Resolved
Bilge pump in engine compartment not secured permanently. Secure pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2021
Resolved 26 July 2021
Resolution: Received photograph of secured pump.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 20 July 2021
Resolved
Gasket on lazarette deck hatch came off. Repair/replace gasket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2021
Resolved 29 July 2021
Resolution: O/O submitted sufficient photos to clear def.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 July 2021
Resolved
FCC Marine Operator permit not onboard. Provide copy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2021
Resolved 26 July 2021
Resolution: Received Copy of valid FCC Marine Operator Permit.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 July 2020
Resolved
Replace expired asprin, eye wash, and moist burn pads in first aid kit 46CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 10 August 2020
Resolution: Owner provided photos of replacement first aid kit items.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 21 July 2020
Resolved
Improper line material on life float floating water light. Replace with appropriate line. 46 CFR 180.175f.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 10 August 2020
Resolution: Owner provided photographs of replacment line installed on floating water light.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 July 2020
Resolved
Floating water light for the ring buoy did not energize. Replace floating light. Vessel is restricted to daytime operations.
Action required: 705 - Other - as specified
Resolved 10 August 2020
Resolution: Owner sent photographs of replacement floating water light for ring bouy
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 16 March 2020
Resolved
Clean paint and sealant from outboard port swim platform hull connection point. 46 CFR 176.610 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2020
Resolution: Removed connection point from swim platform. Area was sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 April 2019
Resolved
Replace life float to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2019
Resolved 14 May 2019
Resolution: O/O replaced life float
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 April 2019
Resolved
Life float paddles are unservicable and need replacement. Water light batteries expired. Vessel is restriceted to daytime operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2019
Resolved 7 May 2019
Resolution: O/O replaced water light batteries and purchased new life float paddles.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 18 April 2019
Resolved
VHF does not have GPS or MMSI information. This information needs to be added to VHF installation.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2019
Resolved 7 May 2019
Resolution: O/O programmed infomation into VHF radio
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 18 April 2019
Resolved
Install chain on port quarter to bring height of handrail to 36".
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2019
Resolved 7 May 2019
Resolution: O/O installed chain to make handrail height 36" as required.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 April 2019
Resolved
Label fuel oil shut off valves.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2019
Resolved 7 May 2019
Resolution: Fuel shut off valves have been labeled.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 23 April 2018
Resolved
Procure and install a new oil pollution placard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2018
Resolved 7 May 2018
Resolution: Discharge placard was installed.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 23 April 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2018
Resolved 7 May 2018
Resolution: Owner provided proof of members enrolment in his companies DAPI program. The documentation was uploaded into MISLE.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 8 March 2018
Resolved
Provide evidence of drug and alcohol training.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2018
Resolved 7 May 2018
Resolution: Owner provided DAPI training logs.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 16 May 2017
Resolved
MAB01: Provide documentation on specifications of fuel hoses/ Due 15JUN2017 Their fuel supply line had SAE J1527 written on them; other fuel lines aft (from fuel filter into engine) had nothing written on them, Operator said they have been that way since he's owned it.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 16 June 2017
Resolution: Recieved email with pictures and specs, all clear. Hoses were replaced
Lifesaving › Lifefloat › Serviceable
Issued 16 May 2017
Resolved
Repair life rafts IAW manufacturer's instructions. Due 15JUN2017
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 16 June 2017
Resolution: Recieved email with pictures, float was repaired with manufactre high vis paint. All sat.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 16 May 2017
Resolved
Provide corrosion resistant clip on life ring water light and lifeline. Due 15JUN2017
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 16 June 2017
Resolution: Recieved email of clip on life ring. All sat.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 29 April 2016
Resolved
JE01 Renew properly endorsed COD
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 May 2016
Resolved 9 June 2016
Resolution: Current COD was placed onboard vessel. Deficiency cleared.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 29 April 2016
Resolved
JE02 Provide drill / crew training log
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 9 June 2016
Resolution: Vessel log book was onboard. Deficiency cleared.
Lifesaving › Hand Flares › Expired
Issued 29 April 2016
Resolved
JE03 Provide sufficient hand flares for route
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 9 June 2016
Resolution: Sufficient hand flares were onboard vessel. Deficiency cleared.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 April 2016
Resolved
JE04 Provide proper first aid kit (asprin).
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 9 June 2016
Resolution: Complete first aid was onboard vessel. Deficiency cleared.
Lifesaving › Lifefloat › Serviceable
Issued 29 April 2016
Resolved
JE05 Renew condition of life floats to like new condition and replace water light battery.
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 9 June 2016
Resolution: Life floats were found in satisfactory condition. Deficiency cleared.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 29 April 2016
Resolved
JE06 Provide approved bracket for portable fire extingusher in cabin.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 9 June 2016
Resolution: Portable fire extingusher in cabin was mounted in an approved bracket. Deficiency cleared.
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 April 2016
Resolved
JE07 Repair high level bilge alarm in forward most compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Resolution: Corrected on the spot. Deficiency JE07 cleared.
Construction/Loadline › Penetrations › Gasket
Issued 29 April 2016
Resolved
JE08 Prevent excessive leak at rudder packing.
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Resolution: Packing was tightened to stop leak during inspection. Deficiency JE08 corrected on the spot and cleared.