MAURY USCG vessel records Sign in
← All vessels

KRISTINA

KRISTINA is a 1979 passenger vessel (inspected). The Coast Guard has recorded 90 inspections since 1984, most recently in December 2025, along with 95 deficiencies, 3 operational controls and 2 casualty investigations between 2013 and 2014.

Records from 1984 to 2025. Most recent: inspection, 1 December 2025.

Built
1979
Last inspected
1 December 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI5000
Flag
UNITED STATES
367704150
Maury page id
psix-52048

Inspections, by type

…with no type recorded6
Years with a record 39 calendar years (1984–2025)
The 90 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)77.9 ft × 20.6 ft × 8.3 ft
Registered tonnagegross 59 / net 40
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOLBERG INC · STOCKTON, CA, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLOS ANGELES-LONG BEACH, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 28 August 2026 · expires 30 September 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it59 - Regulatory (Subpart C or D), Gross Ton
40 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI5000MMSI 367704150 · active · compulsorily equipped · granted 27 November 2025, expires 21 November 2035
WDC2526MMSI 366994330 · expired · compulsorily equipped · granted 30 November 2004, cancelled 31 January 2015
WCY6431MMSI not assigned · expired · compulsorily equipped · granted 19 August 1998, cancelled 25 October 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 90

1 December 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8256608
6 November 2024 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8017356
15 October 2024 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7996431
2 June 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7918006
20 November 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7816748
8 May 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7675411
18 October 2022 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7572198
1 September 2022 COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7471104
2 December 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7348435
8 March 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7152348
8 January 2021 Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7121593
1 December 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7103963
20 October 2020 Internal Structural Exam · Administrative Inspection · Drydock Extension
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7082043
19 September 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6816122
9 September 2019 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6766426
9 October 2018 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6557546
4 September 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6511941
28 November 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6314274
20 September 2017 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6278138
5 September 2017 COI Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6251559
1 December 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6045384
26 October 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6028825
9 December 2015 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5778681
9 November 2015 Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5760558
22 June 2012 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4002227
30 November 2010 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3897583
3 November 2010 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3882358
11 January 2010 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3662070
1 December 2009 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3628350
13 February 2009 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3423988
3 December 2008 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3365042
29 April 2008 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3158915
2 October 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3068654
6 September 2007 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3044425
4 April 2006 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2606710
18 November 2005 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2537227
30 November 2004 Annual Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2248334
17 September 2004 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2198356
12 April 2004 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2040205
5 February 2004 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2001227
4 December 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1956900
19 December 2002 In-Service Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1721553
18 October 2002 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1692043
3 September 2002 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1668815
19 March 2002 Construction Oversight
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1618600
17 January 2002 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1479718
17 October 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1417395
21 February 2001 Deadweight Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1445855
7 February 2001 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1403294
21 September 2000 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1373213
9 September 1999 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1119671
11 January 1999 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 787847
11 January 1999 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1456661
22 September 1998 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 800631
2 September 1998 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 797694
23 September 1997 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1117442
3 January 1997 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1409614
20 December 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1093612
18 December 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1094556
13 September 1996 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1360627
15 September 1995 Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 880273
15 February 1995 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1159304
16 September 1994 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 861436
9 November 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 830390
25 October 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1140416
17 September 1993 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 839493
8 January 1993 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 826434
23 October 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1261537
14 October 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1266346
18 September 1992 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 957477
10 July 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1268844
24 October 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1247697
3 October 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1247941
23 September 1991 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1249196
23 January 1991 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1214108
23 November 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1223352
9 October 1990 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1221945
28 August 1990 Drydock Extension
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1234600
12 December 1989 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 926816
10 October 1989 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1337516
24 February 1989 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1203502
11 October 1988 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1193962
20 July 1988 Drydock Extension
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1033608
10 February 1988 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1023738
13 October 1987 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1322346
25 February 1987 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1324030
23 October 1986 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1015025
23 October 1985 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1304087
22 February 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 978419
23 October 1984 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 974732

Deficiency record · 95

11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 1 December 2025 Resolved
The life line shall be properly secured around the sides and ends of the life float or buoyant apparatus, festooned in bights not longer than 3 feet, with a size and strength not less than 3/8-inch diameter manila. MI observed deteriorated life lines on both forward buoyant apparatuses. Replace Life lines and make available for inspection to the attending marine inspector. 46CFR180.15-5a
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2025
Resolved 11 December 2025
Resolution: Repairs completed to forward lifefloat grab lines. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 December 2025 Resolved
Each life preserver carried on a vessel after june 30,1980, must have at lease 200 sq. cm (31 sq. in.) of retro reflective material attached on its front side, at least 200 sq. cm on its back side, and at least 200 sq. cm of material on each of its reversible sides. MI observed 16 life preservers with worn retro reflective tape. Deficiency was rectified on the spot. 46CFR180.25-25
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 December 2025
Resolved 1 December 2025
Resolution: Retro was replaced during the inspection. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 November 2024 Resolved
Piping, valves, and fittings in a fire main system must comply with subpart G, part 182, of this chapter. Materials used in piping systems must meet the requirements of this subpart and be otherwise acceptable to the cognizant [name withheld] deck #2 fire hydrant found leaking at the valve stem. 46 CFR 181.310(b) 46 CFR 182.700
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2024
Resolved 21 November 2024
Resolution: Received photo from operator of renewed valve stem for the #2 fire hydrant.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 6 November 2024 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. Port side E/R vent closure does not completely close. 46 CFR 182.460(l)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2024
Resolved 21 November 2024
Resolution: Received photo from operator of completely closed port side E/R vent closure.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 November 2024 Resolved
The use of twist-on type wire nuts is permitted under the following conditions: The connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration. MI identified wire nut connections not in an enclosure located under steering console. 46 CFR 183.340(i)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2024
Resolved 21 November 2024
Resolution: Received photo from operator of wire nut connections properly stowed in an enclosure located under steering console.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 15 October 2024 Resolved
Repair wasted bulkhead sections on four (4) windows and two (2) doors of flying bridge operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2024
Resolved 11 December 2024
Resolution: All wasted areas on flying bridge repaired to the satisfaction of the MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 June 2024 Resolved
Flexible nonmetallic hose may be used in lube oil, fuel oil and fluid power systems, subject to the following requirements. Flexible hose on hydraulic pump for steering degraded, small leak in vicinity.46CFR182.720(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2024
Resolved 11 June 2024
Resolution: Replaced hose, witnessed operating for 5 minutes, no drips.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 June 2024 Resolved
All electrical equipment and circuits must be clearly marked and identified. Circuit breaker in engine room for #2 air compressor cover with red tape in the off position. 46CFR183.220(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2024
Resolved 11 June 2024
Resolution: Red tape removed, proper label affixed.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 20 November 2023 Resolved
The float free link required by 180.130(a)(1) must be: of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag. MI discovered life floats on top of bridge did not have identification tag. 46 CFR 180.137(b)(2)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2023
Resolved 22 November 2023
Resolution: Recieved picture proof of replacement from vessel operator.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 20 November 2023 Resolved
Each lifefloat must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Life floats on top of bridge are only equipped with one paddle per lifefloat. 46 CFR 180.175(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2023
Resolved 22 November 2023
Resolution: Received picture proof of replacement from vessel operator.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 September 2022 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in servicable condition must be repaired or replaced. Vessel must submit plans for repair/replacement. Lifefloats were deteriorated. 46 CFR 176.808(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2022
Resolved 30 September 2022
Resolution: Vessel submitted plan for refurbishment of lifesaving..."We are planning to refurbishing the external foam protection from the 2 life rafts at the factory location in North Hollywood when they have available time slots."
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 1 September 2022 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust ducts discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Port side vent was unable to fully close. 46 CFR 182.465(h)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2022
Resolved 30 September 2022
Resolution: Viewed pictures of ventilation in the open and flush closed position to cut off air supply.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 1 September 2022 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and far inboard in the bulkhead as practicable and made watertight. Cable run in fore and aft bulkhead of fuel tank compartment was not fully sealed. 46 CFR 179.320(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2022
Resolved 30 September 2022
Resolution: Bulkhead penetration forward and aft in fuel tank compartment filled with fire proof foam.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 8 March 2021 Resolved
Each survival craft required on a vessel must meet this part. Limited Coastwise life floats. Vessel only has installed and serviceable life floats for 94. Vessel restricted to 94 total persons when operating on a Limited Coastwise route.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2021
Resolved 16 April 2021
Resolution: Vessel properly installed 2 life floats. Vessel can operate at full capacity.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 8 March 2021 Resolved
Rails may not be required where all or part of the space below the upper rail courses fitted with a bulwark, chain link fencing, wire mesh, or equivalent. Wire mesh on port side, forward, is corroded. Vessel has a temporary repair. Vessel to provide permanent repair. (OLD T: 46 CFR 177.35-1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2021
Resolved 16 April 2021
Resolution: Vessel welded steel brackets on steel mesh and welded that to the railing. Permanent repair complete.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 December 2020 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel is overdue for Annual Inspection. Vessel must complete satisfactory Annual Inspection prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2021
Resolution: Completed satisfactory annual inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 December 2020 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel has not completed drydock examination IAW the required timeline. Vessel must complete an examination for credit drydock prior to the carriage of passengers. 46 CFR 176.600(c)(1); 701c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2021
Resolution: Conducted credit dry dock examination.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 19 September 2019 Resolved
Each survival craft required on a vessel must meet this part. Limited coastwise life floats. Vessel only has installed and serviceable life floats for 126. Vessel shall only carry 123 passengers while operating on a coastwise route. 46 CFR 180.200 (c)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 2 December 2021
Resolution: Verified the installation of all required life floats. Passenger count restored to XXX.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 September 2019 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Vessel operator has failed to maintain vessel IAW CFR and has subsequently failed the annual COI inspection. 46 CFR 185.100
Action required: 30 - Ship detained
Due 9 October 2019
Resolved 19 September 2019
Resolution: Vessel completed annual COI inspection, cleared 08 outstanding CG-835s, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 September 2019 Resolved
The minimum capacity of the power driven fire pump shall be 50 GPM at a pressure of not < 60 psi. Fire pump only produced < 40 psi. 46 CFR 181.10-1 (c)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 9 October 2019
Resolved 19 September 2019
Resolution: Fire pump replaced maintained 60 psi with both fire hoses operating, all sat.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 September 2019 Resolved
All vessels shall be provided with not less than 02 avenues of escape from where the crew is normally employed. The aft emergency escape hatch from the engine room was inoperable from inside as the operations was fouled by securing cable. 46 CFR 177.15-1 (a)
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 September 2019
Resolution: Securing cable removed and operation tested from inside engine room.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 September 2019 Resolved
Visual and audible alarms must be provided at the operating station to indicate high water level in each of the following unmanned spaces. Aft lazarette and steering spaces alarms indicate on the same light on the bridge. 46 CFR 182.530 (a)
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 10 October 2019
Resolved 19 September 2019
Resolution: Vessel replaced all bilge alarms with float switches (previously pneumatic installed) and new indicating panel on bridge for all 6 subdivided compartments, witnessed operation test, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 September 2019 Resolved
Machinery, equipment may be inspected IAW good marine practice. Both steering actuators are leaking under operating conditions. 46 CFR 176.800
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 10 October 2019
Resolved 19 September 2019
Resolution: Both steering rams serviced and seals replaced, conducted op test, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 9 September 2019 Resolved
Survival craft on a vessel must meet one of the following. 00 of 07 required life floats are serviceable or properly installed. 46 CFR 180.200 (a)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 10 October 2019
Resolved 19 September 2019
Resolution: 06 life floats for 126 installed and servicable. Cleared 705c CG-835 issued.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 September 2019 Resolved
The owner or operator must conduct all tests as required by the OCMI, and make the vessel available for all specific inspections and drills required by subpart H of this part. In addition, the OCMI may require the vessel to get underway. Perform fire and man overboard drills to the satisfaction of the attending Marine Inspector. 46 CFR 176.404 (a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 October 2019
Resolved 19 September 2019
Resolution: Vessel completed satisfactory fire and man overboard drills, all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 9 September 2019 Resolved
Any vessel of at least 5 net tons which engages in coastwise trade, unless exempt under §67.9(c), must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. Vessel does not have a current COD onboard. 46 CFR 67.7
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 October 2019
Resolved 19 September 2019
Resolution: Valid COD on board 14SEP19- 30SEP20.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 9 September 2019 Resolved
Design of all exhaust systems must ensure minimum risk of injury to personnel. Port main engine outboard turbo exhaust lagging is missing. 46 CFR 182.430 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2019
Resolved 19 September 2019
Resolution: Exhaust lagging on turbo installed, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 September 2019 Resolved
A power-driven vessel underway shall exhibit a stern light. Stern light was found to be inoperable. 33 CFR 83.23 (a) (iv)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 September 2019
Resolution: Bulb replaced, test sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 September 2019 Resolved
Each ring life buoy on a vessel must be approved in accordance with §160.050 in subchapter Q of this chapter. 02 ring buoys grab lines parted when pulled. 46 CFR 180.70 (b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 September 2019
Resolution: Grab lines replaced.
Lifesaving › Lifefloat › Serviceable
Issued 5 September 2017 Resolved
Repair spidering patches on lifefloat.
Condition: Improper/Lack of Maintenance
Due 19 September 2017
Resolved 4 October 2017
Resolution: Removed lifefloat with inadequate repairs from vessel.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 5 September 2017 Resolved
Make engine room vent closures work. Foam gasket added to damper plates for engine room ventilation were preventing the dampers from fully closing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 September 2017
Resolved 5 September 2017
Resolution: Foam blocking was removed on the spot, allowing plates to seat.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 5 September 2017 Resolved
Repair lifejacket retro-reflective tape. 03 Lifejackets had retro-reflective tape that was wasted and/or falling off.
Condition: Improper/Lack of Maintenance
Due 5 September 2017
Resolved 5 September 2017
Resolution: Retro-tape was renewed on 03 lifejackets, on the spot.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 24 November 2015 Resolved
Provide retroreflective tape for 57 adult and 5 child lifejackets
Action required: 705 - Other - as specified
Due 29 December 2015
Resolved 9 December 2015
Resolution: Retroreflective tape applied to 57 adult and 5 child lifejackets
Documentation › Markings/Placards › Capacity Marking
Issued 24 November 2015 Resolved
Provide upper deak passenger count limit placard with updated count of 108.
Action required: 705 - Other - as specified
Due 29 December 2015
Resolved 9 December 2015
Resolution: Upper deck passenger count placard updated to 108.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 30 November 2010 Resolved
Replace the worn out retroreflective material on the life jacket IAW 185.604(h).
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 30 November 2010
Resolution: Operator taped new retroreflective tape on top of the existing retroreflective tape.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 30 November 2010 Resolved
Mark the number of lifejacket on each lifejacket storage container IAW 46 CFR 185.604(f).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 30 November 2010
Resolution: The number of lifejacket was marked on each lifejacket storage container by the operator.
Construction/Loadline › Hull › Keel Plate
Issued 3 November 2010 Resolved
-
Due 3 November 2010
Resolved 3 November 2010
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 December 2009 Resolved
Provide navigation lights that meet UL 1104 IAW 46 CFR 183.420.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 January 2010
Resolved 1 December 2009
Resolution: New lights installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 1 December 2009 Resolved
Cap unused exhaust system piping.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 January 2010
Resolved 1 December 2009
Resolution: Piping removed and ends blanked off.
Fire Fighting › Nozzles › Type
Issued 3 December 2008 Resolved
Provide a brass or other suitable corrosion-resistant material that complies with NFPA standards, fire nozzle for upper deck fire station as required by 46 CFR 181.320(b)(3).
Action required: 705 - Other - as specified
Due 2 February 2009
Resolved 1 February 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 September 2007 Resolved
Replace insulation on all wires within battery boxes in engine room.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 October 2007
Resolved 2 October 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder
Issued 6 September 2007 Resolved
Clean bilges, remove oil absorption pads from bilges and under oil filter for starboard generator. General housekeeping and maintenance of engine room to be completed to minimize leaks.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 October 2007
Resolved 2 October 2007
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 30 November 2004 Resolved
Properly mounted waterlight for vessels lifefloat missing.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 December 2004
Resolved 3 December 2004
Resolution: New waterlight and mounting bracket was purchased and installed to the satisfaction of the attending Marine Inspector.
Fire Fighting › Remote Fuel Shutoff › General
Issued 30 November 2004 Resolved
Emergency fuel shut off valve not labeled IAW 46CFR185.608.
Action required: 705 - Other - as specified
Due 17 December 2004
Resolved 3 December 2004
Resolution: Emergency fuel shut off valve placard purchased and installed on overhead, above the subject valve, and IAW 46CFR185.608.
Communications › Radio Communications › EPIRB
Issued 30 November 2004 Resolved
Vessel could not provide proof of EPIRB registration with NOAA.
Due 17 December 2004
Resolved 3 December 2004
Resolution: Owner provided copy of 406MHz EPIRB registration form and the attending marine inspector verbally confirmed with NOAA help desk that the vessels EPIRB is valid until 02DEC06.
Lifesaving › Lifebuoys
Issued 4 December 2003 Resolved
Stern lifering buoy worn/peeling. Replaced with new lifering on the spot.
Due 4 December 2003
Resolved 4 December 2003
Lifesaving › Lifejacket/PFD (Type III) › Retroreflective Material
Issued 3 September 2002 Resolved
Discovered 20 adult PFD's with worn retro-reflective markings. Required owner to replace worn reflective tape with new retro-reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2002
Resolved 3 September 2002
Resolution: Owner replaced worn retro-reflective tape new retro-reflective tape prior to completion of inspection. All satisfactory.
Documentation
Issued 17 October 2001 Resolved
Provide an emergency evacuation plan as per 46 CFR 116.530.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 November 2001
Resolved 9 September 2002
Resolution: Owner posted an emergency evacuation plan as per 46 CFR 116.530.
Fire Fighting
Issued 17 October 2001 Resolved
Provide closures, operable from outside the engine room, for both the port and starboard engine room vents.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 November 2001
Resolved 9 September 2002
Resolution: Owner provided closures for the P&S ER vents. Closures are applied from the outside via vent covers and a long pole.
Documentation
Issued 17 October 2001 Resolved
Provide an emergency evacuation plan as per 46 CFR 116.520.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 November 2001
Resolved 9 September 2002
Resolution: Owner posted an emergency evacuation plan as per 46 CFR 116.520.
Lifesaving
Issued 21 February 2001 Resolved
Provide corrosion resistant clip for ring bouy light.
Condition: Unknown
Due 24 July 2001
Resolved 24 July 2001
Navigation
Issued 21 February 2001 Resolved
Provide orange storage box for flares.
Condition: Unknown
Due 24 July 2001
Resolved 24 July 2001
Construction/Loadline
Issued 11 January 1999 Resolved
REMOVE OILY WATER FROM ENGINE ROOM BILGES AND MAKE READY FOR INSPECTION.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Construction/Loadline
Issued 22 September 1998 Resolved
MAKE FOREPEAK AVAILABLE FOR INSPECTION AT NEXT DDX OR NO LATER THAN 31JAN99.
Condition: Unknown
Due 22 September 1998
Resolved 22 September 1998
Fire Fighting
Issued 18 December 1996 Resolved
INSTALL CLOSURE DEVICES FOR ENGINE ROOM VENTILATION SYSTEM TO MEET THE REQUIREMENTS OF 46 CFR 181.20-35.
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Fire Fighting
Issued 13 September 1996 Resolved
PROVIDE CERTIFICATION FOR OCT 96 CO2 BOTTLE HYDROSTATIC TESTING.
Condition: Unknown
Due 13 September 1996
Resolved 13 September 1996
Fire Fighting
Issued 13 September 1996 Resolved
PROVE PROPER SHUTDOWN OF ENGINEROOM VENTILATION. PRIOR TO INSTALLING DAMPER SYSTEM FOR PORT, AFT VENT, PROVIDE PLANS TO THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 13 September 1996
Resolved 13 September 1996
Electrical
Issued 15 September 1995 Resolved
PROPERLY SUPPORT WIRING IN OVERHEAD OF ENGINE ROOM.
Condition: Unknown
Due 26 January 1996
Resolved 26 January 1996
Engineering
Issued 15 September 1995 Resolved
PROVE PROPER OPERATION OF THE RELIEF VALVE FOR THE PORT START AIR RECEIVER.
Condition: Unknown
Due 31 January 1996
Resolved 26 January 1996
Construction/Loadline
Issued 15 February 1995 Resolved
MAKE AFT PORTSIDE DOOR ON DECK #1 OPERATIONAL AND WEATHERTIGHT
Condition: Unknown
Due 12 March 1995
Resolved 7 March 1995
Accommodation/Occupational Safety
Issued 15 February 1995 Resolved
REPAIR SEAL AROUND PILOTHOUSE WINDOW, PORTSIDE
Condition: Unknown
Due 12 March 1995
Resolved 7 March 1995
Engineering
Issued 16 September 1994 Resolved
PROVE THAT RACOR FUEL FILTERS DO NOT REQUIRE FLAME IMPINGEMENT BOWLS OR PROVIDE BOWLS.
Condition: Unknown
Due 16 September 1994
Resolved 16 September 1994
Navigation
Issued 16 September 1994 Resolved
PROVIDE BINNACLE COVER.
Condition: Unknown
Due 16 September 1994
Resolved 16 September 1994
Lifesaving
Issued 16 September 1994 Resolved
APPLY RETROFLECTIVE TAPE TO ALL (3) BUOYANT APPARATUS'.
Condition: Unknown
Due 16 September 1994
Resolved 16 September 1994
Lifesaving
Issued 16 September 1994 Resolved
RENEW 100 FT PAINTER FOR BUOYANT APPRATUS', OPERATOR AGREED TO REPLACE WEAKLINK.
Condition: Unknown
Due 16 September 1994
Resolved 16 September 1994
Navigation
Issued 16 September 1994 Resolved
RENEW BULB FOR NAVIGATION LIGHT INDICATOR WARNING PANEL.
Condition: Unknown
Due 16 September 1994
Resolved 16 September 1994
Navigation
Issued 16 September 1994 Resolved
INVESTIGATE, FIND, AND CORRECT NOISE EMANATING FROM STEERING GEAR.
Condition: Unknown
Due 16 September 1994
Resolved 16 September 1994
Documentation
Issued 16 September 1994 Resolved
PROVE THE FOLLOWING AMPLYFYING INFORMATION FOR DRUG TEST PROGRAM: A) LIST OF DRUGS TESTED FOR PROGRAM, B) SMITH KLINE LAB ADDRESS AND PHONE NO.
Condition: Unknown
Due 16 September 1994
Resolved 16 September 1994
Engineering
Issued 17 September 1993 Resolved
PROVIDE PROPULSION ENGINE LUBRICATING OIL PRESSURE AND COOLING WATER TEMPERATURE GUAGES AT THE OPERATOR CONTROL STATION IN THE PILOTHOUSE.
Condition: Unknown
Due 17 September 1993
Resolved 17 September 1993
Engineering
Issued 17 September 1993 Resolved
REPAIR COOLANT LEAK ON STBD MAIN ENGINE TURBOCHARGER.
Condition: Unknown
Due 17 September 1993
Resolved 17 September 1993
Deck/Cargo
Issued 17 September 1993 Resolved
REPAIR ANCHOR TO ALLOW FREE MOVEMENT OF FLUKES. REPLACE ANCHOR LINE WITH A MINIMUM OF 300 FEET OF 1" DIAMETER NYLON RODE. REPLACE DETERIORATED THIMBLEAT LINE-TO-CHAIN CONNECTION.
Condition: Unknown
Due 17 September 1993
Resolved 17 September 1993
Documentation
Issued 17 September 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 September 1993
Resolved 17 September 1993
Engineering
Issued 17 September 1993 Resolved
REPAIR LEAK TO MAIN ENGINE DRY EXHAUST LINE IN STEERING GEAR COMPARTMENT.
Condition: Unknown
Due 17 September 1993
Resolved 17 September 1993
Construction/Loadline
Issued 17 September 1993 Resolved
INSTALL CAPTIVE DEVICES ON ALL HATCHES ON THE MAIN DECK.
Condition: Unknown
Due 17 September 1993
Resolved 17 September 1993
Construction/Loadline
Issued 17 September 1993 Resolved
REPLACE GASKET AROUND DOOR IN AFT TONNAGE OPENING.
Condition: Unknown
Due 17 September 1993
Resolved 17 September 1993
Construction/Loadline
Issued 17 September 1993 Resolved
REMOVE SEALANT FROM AFT TONNAGE OPENING.
Condition: Unknown
Due 17 September 1993
Resolved 17 September 1993
Accommodation/Occupational Safety
Issued 18 September 1992 Resolved
STENCIL EMERGENCY ESCAPE "KEEP CLEAR" ON ENGINE ROOM ESCAPE HATCH.
Condition: Unknown
Due 18 September 1992
Resolved 18 September 1992
Engineering
Issued 18 September 1992 Resolved
CLEAN HYDRAULIC OIL FROM #4 COMPARTMENT.
Condition: Unknown
Due 18 September 1992
Resolved 18 September 1992
Electrical
Issued 18 September 1992 Resolved
INSTALL BLANKS ON OPENINGS TO SWITCHBOARD.
Condition: Unknown
Due 18 September 1992
Resolved 18 September 1992
Lifesaving
Issued 18 September 1992 Resolved
STENCIL VESSEL NAME ON BUOYANT APPARATUS.
Condition: Unknown
Due 18 September 1992
Resolved 18 September 1992
Engineering
Issued 18 September 1992 Resolved
REPAIR EXHAUST LEAK INWAY OF AFT COMPARTMENT.
Condition: Unknown
Due 18 September 1992
Resolved 18 September 1992
Lifesaving
Issued 18 September 1992 Resolved
INSTALL ALARMS OR GAUGES FOR GENERATORS ON BRIDGE AS PER 46 CFR 183 AND 46 CFR SUBCHAPTER J.
Condition: Unknown
Due 18 September 1992
Resolved 18 September 1992
Engineering
Issued 18 September 1992 Resolved
INSTALL SCREEN OVER ENGINE ROOM EXHAUST.
Condition: Unknown
Due 18 September 1992
Resolved 18 September 1992
Construction/Loadline
Issued 18 September 1992 Resolved
REPAIR ENGINE ROOM HATCH AND DOGGING DEVICE.
Condition: Unknown
Due 18 September 1992
Resolved 18 September 1992
Lifesaving
Issued 23 September 1991 Resolved
SEAL HOLES IN BUIYANT APPARATUS WHERE SEAGULLS HAVE EATEN INTO THEM.
Condition: Unknown
Due 23 October 1991
Resolved 8 October 1991
Deck/Cargo
Issued 23 September 1991 Resolved
FREE UP FLUKES AND SHACKLE ON THE ANCHOR SO THEY MOVE FREELY.
Condition: Unknown
Due 23 October 1991
Resolved 8 October 1991
Engineering
Issued 9 October 1990 Resolved
INSTALL REACH ROD FOR VALVE FORWARD OF COLLISION BULKHEAD SO AS TO BE OPERABLE FROM THE MAIN DECK.
Condition: Unknown
Due 9 October 1990
Resolved 9 October 1990
Construction/Loadline
Issued 9 October 1990 Resolved
RE-LABEL ENGINE SPACE EMERGENCY ESCAPE HATCH INSIDE AND OUT.
Condition: Unknown
Due 9 October 1990
Resolved 9 October 1990
Fire Fighting
Issued 9 October 1990 Resolved
REPAIR WASTED FIRE STATION BOX UPPER DECK STBD SIDE.
Condition: Unknown
Due 9 October 1990
Resolved 9 October 1990
Lifesaving
Issued 9 October 1990 Resolved
RE-LABEL LIFE JACKET STORAGE UPPER DECK TO REFLECT ACTUAL NUMBER OF JACKETS PER BOX.
Condition: Unknown
Due 9 October 1990
Resolved 9 October 1990
Electrical
Issued 9 October 1990 Resolved
RENEW ARMORED CABLE PORT SIDE MIDSHIPS UNDER BENCH SEAT IN WAY OF PLUG SOCKET.
Condition: Unknown
Due 9 October 1990
Resolved 9 October 1990
Engineering
Issued 9 October 1990 Resolved
RE-LABEL REMOTE FUEL SHUT-OFF.
Condition: Unknown
Due 9 October 1990
Resolved 9 October 1990
Lifesaving
Issued 9 October 1990 Resolved
MOUNT MAIN DECK RING LIFE BUOY IN AN ACCESSIBLE LOCATION.
Condition: Unknown
Due 9 October 1990
Resolved 9 October 1990
Accommodation/Occupational Safety
Issued 10 October 1989 Resolved
REMOVE, SEAL, OR OTHERWISE BLOCK MSD OVERFLOW LINE SO THAT OVERBOARD DISCHARGE THROUGH THIS LINE IS IMPOSSIBLE.
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Engineering
Issued 10 October 1989 Resolved
LOCATE AND REPAIR EXHAUST LEAK IN COMPARTMENT AFT OF E/R.
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989

Casualty record · 2

12 June 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4618404
26 April 2014Routine · role: Involved in a Marine Casualty · activity 4846147
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.