OCEAN ODYSSEY is a 1980 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 2016, most recently in June 2026, along with 12 deficiencies and 4 casualty investigations between 2006 and 2022.
Records from 2006 to 2026. Most recent: inspection, 11 June 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
DocumentationValid · issued 29 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton 67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 27
11 June 2026Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8405546
30 October 2025In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8267319
4 June 2025Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8152081
16 January 2025Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8056841
8 October 2024In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8016209
6 June 2024Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8015818
6 June 2023COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7683657
8 February 2023Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7568246
20 July 2022Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7530089
7 June 2022Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7470747
21 January 2022In-Service Inspection · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7393690
11 August 2021In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7285187
7 June 2021Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7222571
3 June 2021Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7214295
6 April 2021Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7169685
8 June 2020Annual Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6971300
30 March 2020Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6932519
27 March 2020Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6933241
24 January 2020Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6902321
4 October 2019In-Service Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6828110
24 June 2019Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6724404
4 June 2019Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6696927
26 September 2018Administrative Inspection
Administrative · Navigation Center · Activity 6548927
5 June 2018COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6427715
2 November 2017Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6299068
5 June 2017Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6166131
3 June 2016Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5896205
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2022Resolved
STBD Generator electrical control panel not properly sealed; 1 inch hole opening. Install knockout seal.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 14 June 2022
Resolution: Installed knock-out seal.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2022Resolved
Engine room switchboard panel transfer switch loose and not properly sealed. Repair.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 14 June 2022
Resolution: Re-secured and installed seal over switch unit.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2022Resolved
Engine room STBD outboard pump motor controller bottom panel cable penetration not sealed. Repair.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 14 June 2022
Resolution: Installed cable seal.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2022Resolved
Engine room AFT bulkhead STBD side electrical panel not
sealed; 1/2 inch hole opening on right side. Repair.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 14 June 2022
Resolution: Installed knock-out seal.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2022Resolved
Steering gear room STBD side overhead light fixture not properly mounted; missing securing hardware. Repair.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 14 June 2022
Resolution: Installed fixture mounting hardware and re-secured light fixture.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 June 2021Resolved
EPRIRB failed during integrated test. The master of the vessel shall ensure that:(a) Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. Repair or replace EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 June 2021
Resolved 11 June 2021
Resolution: Received documentation of new EPIRB to include EPIRB Registration, and witnessed satisfactory test.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 8 June 2020Resolved
02 twelve (12) man life floats were significantly damaged. Repair or replace the two damaged life floats. Total person count reduced to 62 until this deficiency is corrected.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 6 April 2021
Resolution: View activity narrative for details.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 October 2019Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessel's electrical plans on file. Provide an up-to-date one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 4 January 2020
Resolved 4 February 2020
Resolution: Verified.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 4 October 2019Resolved
Complete & simple instructions for the operation of the E/R CO2 system must be located each pull box. Label is now faded. Properly label instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2019
Resolved 4 February 2020
Resolution: Cleared on earlier date.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 October 2019Resolved
All escape hatches must be marked "EMERGENCY EXIT - KEEP CLEAR" on both sides of the exit. Properly mark.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2019
Resolved 24 January 2020
Resolution: Verified.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 October 2019Resolved
Adequate emergency lighting automatically actuated upon power failure shall be fitted along the line of escape in below deck passenger accommodations. Add one emergency light near top of aft accommodation emergency exit.
Action required: 705 - Other - as specified
Due 4 December 2019
Resolved 24 January 2020
Resolution: Verified.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 26 September 2018Resolved
ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 10 May 2019
15 October 2006Routine · role: Involved in a Marine Casualty · 1 injured · activity 2804522
25 August 2012Routine · role: Involved in a Marine Casualty · activity 4423592
3 October 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4998594
20 July 2022Routine · role: Involved in a Marine Casualty · 1 injured · activity 7530089
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.