Records from 1987 to 2005. Most recent: inspection, 17 June 2005.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 28
17 June 2005
Administrative Inspection
Administrative · MSD SITKA · USCG Arctic District (CGD-A) · Activity 2393941
4 August 2004
Periodic Inspection
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 2156338
6 May 2004
Hull Examination · Internal Structural Exam
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 2062008
18 August 2003
Deficiency Check · Annual Inspection
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 1867828
16 June 2003
Examination of Repairs · Deficiency Check
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 1858625
4 March 2003
Deficiency Check
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 1753227
18 July 2002
Plan Review "T" Boat · Annual Inspection · Deficiency Check
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 1649009
26 April 2002
Hull Examination · Internal Structural Exam
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 1609927
19 November 2001
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 772661
31 August 2001
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 772442
31 July 2001
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1366558
30 March 2001
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1062399
18 August 2000
Type not recorded
No type recorded · MSD SITKA · USCG Arctic District (CGD-A) · Activity 149955
6 August 2000
Type not recorded
No type recorded · MSD SITKA · USCG Arctic District (CGD-A) · Activity 66078
12 June 2000
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 818934
28 April 2000
Hull Examination · COI Inspection · MARPOL Annex V Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1379052
9 July 1999
Type not recorded
No type recorded · MSD SITKA · USCG Arctic District (CGD-A) · Activity 726460
2 July 1999
Type not recorded
No type recorded · MSD SITKA · USCG Arctic District (CGD-A) · Activity 70750
2 July 1999
Type not recorded
No type recorded · MSD SITKA · USCG Arctic District (CGD-A) · Activity 220828
7 May 1999
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 794907
27 February 1999
Re-Inspection · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1440105
4 January 1999
Damage Survey · Examination of Repairs
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1473205
27 December 1998
Type not recorded
No type recorded · MSD SITKA · USCG Arctic District (CGD-A) · Activity 7814
27 April 1998
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1404688
9 June 1997
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1406125
27 February 1997
COI Inspection · MARPOL Annex I Examination · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1385907
5 March 1996
Inclining Experiment · Initial Certification
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 941869
13 July 1987
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1015938
Lifesaving › Buoyant Apparatus
Issued 18 August 2003
Resolved
Make repairs to both buoyant apparatus, to include:
Replacing lines with black or UV resistant floating line. Remove extensive mold on underside. Re-stencil vessel name. And, renew retro reflective tape. LEGACY COMPONENT DESC: Serviceability
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2003
Resolved 27 August 2003
Resolution: Repairs made
Communications › Alarms/Indicators
Issued 18 August 2003
Resolved
Prove proper operation of bilge high level alarm audible annunciator for engine room and provide bilge high level alarm for lazerette. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 September 2003
Resolved 27 August 2003
Resolution: New alarms installed and operable
Lifesaving › Buoyant Apparatus › Not on Board
Issued 16 June 2003
Resolved
The vessel is restricted from sailing with more than 6 passengers in Alaskan waters until provided inflatable buoyant apparatus for 100% of the persons allowed to be carried on the Certificate of Inspection in accordance with CGD17INST 16714.1 and Officer-in-Charge Marine Inspections Juneau policy. LEGACY COMPONENT DESC: Inflatable Buoyant Apparatus
Action required: 705 - Other - as specified
Due 16 June 2003
Resolved 25 June 2004
Documentation › Certificates/Documents
Issued 18 July 2002
Resolved
Locate and post current Certificate of Documentation. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Unknown
Due 19 August 2002
Resolved 9 August 2002
Resolution: Sighted new documentation
Documentation › Certificates/Documents
Issued 18 July 2002
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 19 August 2002
Resolved 9 August 2002
Resolution: Sighted proper FCC radio station license
Engineering › Bilge Water Management System
Issued 18 July 2002
Resolved
Provide a visual signal for the Lazerette High Water Alarm. LEGACY COMPONENT DESC: High water alarm
Condition: Improper Installation
Due 20 August 2002
Resolved 22 August 2002
Resolution: Tested new visual alarm.
Electrical › Electrical Distribution System (service)
Issued 18 July 2002
Resolved
Replace inoperative ammeter for the generator power distribution panel LEGACY COMPONENT DESC: Ammeter
Action required: 705 - Other - as specified
Due 31 March 2003
Resolved 1 July 2003
Resolution: Replaced
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 18 July 2002
Resolved
Renew 3 class 100 fittings on Fixed CO2 System with proper class 300 fittings in accordance with Sub-chapter F, NFPA, and KIDDEE Installation Manual. LEGACY COMPONENT DESC: Fittings
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 September 2002
Resolved 7 November 2002
Resolution: New Fittings installed
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 18 July 2002
Resolved
Renew CO2 System or provide suitable alternative. 1990 cu. ft. space IAW plans requires minimum of 110 lbs CO2, not accounting for space permeability, and extra CO2 to quench the engines. Only 100 lbs. is provided. Vessel limited to the carriage of not more than 6 passengers until corrected. LEGACY COMPONENT DESC: Quantity of CO2
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2002
Resolved 9 August 2002
Resolution: Remeasured space as accurately as possible and allowed exemption of 100 cu. ft. for water tanks. Space now measures 1534 cu. ft. which is adequately serviced by 100 lbs. of CO2.
Engineering › Fuel Oil Service System
Issued 18 July 2002
Resolved
Provide 30 x 30 mesh flame screens for both port and starboard fuel tank vents. LEGACY COMPONENT DESC: Vent Pipe
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 August 2002
Resolved 22 August 2002
Resolution: Sighted newly installed 30 x 30 bronze screens.
Fire Fighting › Fixed Fire Detection System
Issued 26 April 2002
Resolved
Renew unapproved fixed fire detection system with one approved by the Coast Guard for use on a Small Passenger Vessel. LEGACY COMPONENT DESC: Unapproved system
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2002
Resolved 9 August 2002
Resolution: Plan review completed 08/08/02. New system testing and inspection completed 08/09/02.
Engineering › Shafting/Propeller Arrangements
Issued 26 April 2002
Resolved
Renew port Cutlass Bearing due to excessive wear. LEGACY COMPONENT DESC: Bearing
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2002
Resolved 29 April 2002
Resolution: Determined wear to be only at end due to fishing line, approved for continued use.
Engineering › Steering Gear System
Issued 26 April 2002
Resolved
Replace missing set screw to lower bearing on port rudder. LEGACY COMPONENT DESC: Rudder Bearing
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2002
Resolved 29 April 2002
Resolution: Installed
Construction/Loadline › Structures
Issued 26 April 2002
Resolved
Renew main deck forward, due to rotted wood substructure which was been improperly repaired w/o CG oversight. The due date is set for the end of the operating season. The vessel is restricted to operating not more than 3 miles from land on exposed waters and must make additional temporary repairs LEGACY COMPONENT DESC: Deck Plating
Action required: 705 - Other - as specified
Due 15 December 2002
Resolved 23 July 2003
Resolution: Deck renewed
Construction/Loadline › Structures
Issued 26 April 2002
Resolved
Renew main deck stbd side aft due to rotting wood substructure. The due date is set for the end of the operating season. LEGACY COMPONENT DESC: Deck Plating
Action required: 705 - Other - as specified
Due 15 December 2002
Resolved 23 July 2003
Resolution: Deck and affected structures renewed.
Construction/Loadline › Structures
Issued 26 April 2002
Resolved
Crop and renew areas of rot in collision bulkhead. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2002
Resolved 29 April 2002
Electrical › Electrical Distribution System (service)
Issued 26 April 2002
Resolved
Wrap household wire nuts in electrical tape and place in Junction boxes or renew with UL Marine grade crimp connectors through out vessel. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 May 2002
Resolved 30 April 2002
Resolution: Corrected.
Electrical › Electrical Distribution System (service)
Issued 26 April 2002
Resolved
Place improperly installed light switch in port accommodations closet into a suitable electrical box and mount on bulkhead. LEGACY COMPONENT DESC: Switch
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 May 2002
Resolved 29 April 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 26 April 2002
Resolved
Provide lagging for areas not insulated on dry exhaust or show proof of double insulation. LEGACY COMPONENT DESC: Exhaust Lagging
Action required: 705 - Other - as specified
Due 3 May 2002
Resolved 29 April 2002
Engineering › Bilge Water Management System
Issued 26 April 2002
Resolved
Replace "Bilgeflex" hose used in independent Rule bilge pumps with hose suitable for the service. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 May 2002
Resolved 29 April 2002
Resolution: Replaced
Electrical › Lighting (emergency)
Issued 26 April 2002
Resolved
Make repairs to lighting fixtures in engine room where missing covers. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 3 May 2002
Resolved 29 April 2002
Electrical › Electrical Distribution System (service)
Issued 26 April 2002
Resolved
Remove gang plug servicing 4ea. 1500 watt heaters used to defog pilot house windows. Electrical service can not support approx. 50 amps total load without tripping circuit breaker and wire is insufficient to carry the load. Provide proposal to alter present installation. LEGACY COMPONENT DESC: Improper distribution
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 May 2002
Resolved 29 April 2002
Resolution: Gang plug removed, owner researching alternatives as these heaters where used for deicing/defogging window.
Lifesaving
Issued 31 July 2001
Resolved
Ensure contents of first-aid kit meets the requirements of 46 CFR 184.710 and that expired contents are replaced.
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Electrical
Issued 31 July 2001
Resolved
Ensure emergency lighting is automatically actuated upon loss of normal power, is not portable, is connected to an automatic battery charger and has capacity for a minimum of 2 hours of continuous operations in accordance with 46 CFR 183.432.
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Documentation
Issued 31 July 2001
Resolved
Renew expired FCC Safety Radiotelophone Certificate.
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Accommodation/Occupational Safety
Issued 31 July 2001
Resolved
Install a pressure-temperature relief device on the water heater tank in accordance with 46 CFR 182.320.
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Lifesaving
Issued 31 July 2001
Resolved
Post placard that is accessible and visible to the crew and passengers containing instructions for the donning and use of each type of life jacketaboard the vessel in accordance with 46 CFR 185.516.
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Construction/Loadline
Issued 28 April 2000
Resolved
SECURE ELECTRIC BILGE PUMP IN FORWARD COMPARTMENT BILGE.
Condition: Unknown
Due 28 April 2000
Resolved 28 April 2000
Fire Fighting
Issued 28 April 2000
Resolved
PROVIDE PROOF OF SERVICING BY AN APPROVED SERVICING FACILITY FOR FIXED C02 FIRE EXTINGUISHING SYSTEM IN ACCORDANCE WITH 46 CFR 176.810.
Condition: Unknown
Due 28 April 2000
Resolved 28 April 2000
Lifesaving
Issued 28 April 2000
Resolved
POST LIFE PRESERVER DONNING PLACARDS IN ACCORDANCE WITH 46 CFR 185.516.
Condition: Unknown
Due 28 April 2000
Resolved 28 April 2000
Lifesaving
Issued 28 April 2000
Resolved
REPLACE BATTERIES IN WATER LIGHTS ATTACHED TO THE PORT BUOYANT APPARATUS AND PORT RING BUOY IN ACCORDANCE WITH 46 CFR 185.604.
Condition: Unknown
Due 28 April 2000
Resolved 28 April 2000
Fire Fighting
Issued 27 February 1999
Resolved
Install a smoke detector that complies with 46CFR181.450 in each overnight accomodation space, as required by 46CFR181.400(e). (Three sleeping areas were noted to require this installation.)
Condition: Unknown
Due 27 February 1999
Resolved 27 February 1999
Fire Fighting
Issued 27 February 1999
Resolved
Install fixed fire system as required by 46CFR181.400(a)(2).
Condition: Unknown
Due 27 February 1999
Resolved 27 February 1999
Lifesaving
Issued 27 February 1999
Resolved
As required by 46CFR185.420, 520 and 524, Conduct and log training in emergency instruction and drills to include abandon ship, man overboard andfire fighting.
Condition: Unknown
Due 27 February 1999
Resolved 27 February 1999
Construction/Loadline
Issued 27 February 1999
Resolved
Submit proposal to repair rotted cabin roof area in the overhang aft of thehouse. Per 46CFR177.100 this situation is unsafe and must be corrected.
Condition: Unknown
Due 27 February 1999
Resolved 27 February 1999
Construction/Loadline
Issued 27 February 1999
Resolved
As required by 46CFR182.422(b), install shut off valves where the keel cooler piping penetrates the hull. This is required on both engines and thecooler for the generator.
Condition: Unknown
Due 27 February 1999
Resolved 27 February 1999
Lifesaving
Issued 27 February 1999
Resolved
Install weak link approved under 46CFR160.073 on survival craft as requiredby 46CFR180.130(a)(1) and 137(b)(1).
Condition: Unknown
Due 27 February 1999
Resolved 27 February 1999
Engineering
Issued 27 February 1999
Resolved
Install shielding around exhaust pipe where it passes thru deck over each engine, as required by 46CFR182.430(g)(1). This must be corrected prior tooperations with passengers.
Condition: Unknown
Due 27 February 1999
Resolved 27 February 1999
Construction/Loadline
Issued 27 February 1997
Resolved
Renew the soft wood in way of the breast hook and under deck stiffeners in the forepeak.
Condition: Unknown
Due 27 February 1997
Resolved 27 February 1997
Construction/Loadline
Issued 27 February 1997
Resolved
Bed or through bolt stem guard to better secure it in place.
Condition: Unknown
Due 27 February 1997
Resolved 27 February 1997