Records from 2016 to 2025. Most recent: inspection, 13 August 2025.
Inspection history · 24
13 August 2025
Examination of Repairs · Administrative Inspection · Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8212570
5 March 2025
Uninspected Passenger Vessel
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8091216
27 February 2025
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8085485
20 May 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7915567
14 August 2023
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7768310
27 May 2023
Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7697755
16 May 2023
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7690003
19 October 2022
Drydock Exam · Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7579880
2 October 2022
Damage Survey · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7570036
8 August 2022
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7528421
27 July 2022
Damage Survey · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7518567
27 June 2022
Deficiency Check · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7488748
6 April 2022
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7424734
14 July 2021
Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7256441
21 May 2021
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7202876
11 February 2021
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7139127
28 February 2020
Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6916573
16 May 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6683889
28 February 2019
Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6633112
22 March 2018
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6376427
7 October 2017
Administrative Inspection · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6288611
18 May 2017
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6148994
13 March 2017
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6103735
9 May 2016
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5872261
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 13 August 2025
No resolution recorded
Wood rot was found in the stern access door frame.
Action required: 705 - Other - as specified
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 May 2024
Resolved
For fixed-gas fire extinguishing systems, the owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Provide the most recent Fire-Boy pre-engineered fire suppression system service report with details of the testing and type of examination conducted by servicing company. 46 CFR 176.810 Code 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2024
Resolved 5 June 2024
Resolution: A new servicing certificate and report was provided, as contracted techinician did the servicing again.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 23 May 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2024
Resolved 6 June 2024
Resolution: A new FCC radio station license with correct ownership was issued by FCC and received in our office.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 May 2024
Resolved
A submersible electric bilge pump may be used as a power bilge pump and shall be permanently mounted. Forward engine room submersible electrical bilge pump was found not to be secured to the hull structure bottom. 46 CFR 180.520(e), Code 16C.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2024
Resolved 5 June 2024
Resolution: Pump was fixed to the vessel internal structure.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 May 2024
Resolved
Each life jacket carried carried on board must be marked with vessel name. Life jackets had an easily peel-off vessel name sticker and not permanent to the jacket. 46 CFR 180.71(e) 10C.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 23 May 2024
Resolution: All lifejackets had permanent marking prior finishing the exam. Label was removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 May 2024
Resolved
A vessel of more than 26 feet in length, but not more than 65 feet, must carry a minimum of one life buoy of not less than 24 inches in diameter. Lifering color was found faded. 46 CFR 180.70 Code 16C
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2024
Resolved 5 June 2024
Resolution: A new ring buoy was purchased, marked with vessel name and hailing port.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 May 2024
Resolved
A vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible, extracts for the areas to be transited may be provided instead of the complete publication. Nautical chart was not up-to-date and dated YR1998. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2024
Resolved 5 June 2024
Resolution: A new updated chart was purchased and placed on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 May 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure and personal injury. The following shall be corrected:
a. steering water intrusion at the rudder post assembly; b. remove oily absorbent materials found in bilges;
c. correct raw cooling water leak at the water pump and fire pump;
d. correct excessive diesel engine oil leaks as indicated and identified during the exam.
46 CFR 182.100, Code 16C
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2024
Resolved 5 June 2024
Resolution: Steering water intrusion was corrected by adjusting the packing, oily materials in bilge were removed and a mechanic conducted a tune up in the engine, replacing gaskets and sealing other components.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 23 May 2024
Resolved
A hatch exposed to the weather must be watertight and have securing devices. Steering compartment hatch is not watertight and needs to be secured to the vessel. 46 CFR 179.360, COde 16C.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2024
Resolved 5 June 2024
Resolution: A rubber gasket was installed and hatch secured to the internal framing.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 May 2024
Resolved
Provision must be made for closing all air supply for a space protected by a fixed gas extinguishing system. All three engine compartment hatch covers were found not to be airtight and with holes, allowing air to enter the space if Fire-Boy fire suppression system is activated allowing CO2 to escape the protected area, in an enclosed passenger accommodation area. 46 CFR 182.465 (h) Code 16C.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2024
Resolved 5 June 2024
Resolution: A rubber gasket was installed in all 3 hatches and made airtight.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2024
No resolution recorded
Electrical installation including, but not limited to:
(i) Elementary one-line diagram of the power system;
(ii) Cable lists;
(iii) Bills of materials;
(vi) Power, lighting, and interior communication panel boards with number of circuits and rating of energy
consuming devices;
(vii) Type of capacity of storage batteries;
(ix) Electrical plant load analysis.
Vessel does not have a current one line diagram and over
the years has had much work done without verifying gauge
of wiring installed or removing unused or extra wiring.
Operator shall identify all repairs and alterations work conducted without USCG approval and identifying the items listed. Submit an electrical One-Line Diagram to the USCG Marine Safety Center no later than 31JULY2024. Once approved, then conduct all necessary repairs according with such plan and 46 CFR 111 and 183. 46 CFR 177.202 COde 705C due in 31JULY2024.
Action required: 705 - Other - as specified
Due 31 July 2024 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 May 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel operator reported high engine temperature and heat exchanger not operating as intended. Vessel operator required to submit engine diagnostic report and repair proposal prior to beginning work. Vessel must conduct sea trial to the satisfaction of the attending marine inspector prior to operating commercially. 46 CFR 182.200(a)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2023
Resolution: A sea trial was conducted and vessel engine was found properly working.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 16 May 2023
Resolved
No marine employer shall engage or employ any individual to serve as a crew member unless the individual passes a chemical test for dangerous drugs for that employer. Captain could not present valid evidence of completing preemployment drug testing.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2023
Resolved 22 May 2023
Resolution: A chemical testing results have been provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 May 2023
Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Water light battery was not of the approved type and did not operate as designed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2023
Resolved 22 May 2023
Resolution: An approved type battery was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 May 2023
Resolved
Each ring life buoy on a vessel must:(1) Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Ring life buoy grab line is deteriorated and requires renewal.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2023
Resolved 22 May 2023
Resolution: Grabline was replaced by a new one.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 16 May 2023
Resolved
The cognizant OCMI may require that a vessel and its
equipment undergo any additional test or inspection
deemed reasonable and necessary to determine that the
vessel and its equipment are suitable for the service in
which they are to be employed. Vessel experienced
excessive water intrusion through rudder stock and shaft
penetration when in operation triggering electronic
bilge pump aft of main engine during entirety of
underway drills. Operator to assess cause of excessive
intrusion and prepare vessel for sea trial prior to
operating.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2023
Resolved 23 May 2023
Resolution: A new shaft packing was installed and adjusted the packing gland.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 May 2023
Resolved
A vessel must be provided with bilge pumps in accordance
with Table 182.520(a). A second power pump is an
acceptable alternative to a hand pump if it is supplied
by a source of power independent of the first power
bilge pump. Vessel has no hand pump.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 11 July 2023
Resolution: A new portable bilge handpump was located on board the vessel.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 May 2023
Resolved
Abandon ship and man overboard drills and training shall
be logged or otherwise documented for review by the
Coast Guard upon request. The drill entry shall include
the following information:(1) Date of the drill and
training; and (2) General description of the drill scenario and training topics. Drills not regularly logged or conducted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 19 July 2023
Resolution: Drills have been conducted and logged in appropriate format as required by CFR.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 May 2023
Resolved
Portable and semi-portable extinguishers must be
inspected and maintained in accordance with NFPA 10
(incorporated by reference, see § 175.600 of this
chapter) as amended here: (ii) Monthly inspections
required by NFPA 10 may be conducted by the owner,
operator, person-in-charge, or a designated member of
the crew. Inspect portable extinguishers monthly and log
in log book.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 19 July 2023
Resolution: Fire equipment was checked and logged in the vessel's logbook.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2023
Resolved
A suitable metal marine type strainer, meeting the
requirements of the engine manufacturer, must be fitted
in the fuel supply line in the engine compartment.
Installed filter had particulate matter in bottom and
was black in color. Conduct proper maintenance and
replace parts as needed. Not operating as intended.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 13 July 2023
Resolution: Fuel strainers have been cleaned.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 May 2023
Resolved
The discharge ends of fuel tank vent pipes must be
fitted with removable flame screens or flame arresters.
The flame screens must consist of a single screen of
corrosion resistant wire of at least 30 × 30 mesh. Fuel
tank did not have flame screen.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 11 July 2023
Resolution: A flame arrestor mesh was installed.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 16 May 2023
Resolved
A durable placard must be posted next to all
radiotelephone installations with the emergency
broadcast instructions and information, specific to the
individual vessel. Placard posted does not have
information specific to the vessel for master to utilize
in event of emergency.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 11 July 2023
Resolution: A FCC issued emergency boardcasting placard was located at the operating station, next to the radio.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2023
Resolved
Electrical installation including, but not limited to:
(i) Elementary one-line diagram of the power system;
(ii) Cable lists;
(iii) Bills of materials;
(vi) Power, lighting, and interior communication
panelboards with number of circuits and rating of energy
consuming devices;
(vii) Type of capacity of storage batteries;
(ix) Electrical plant load analysis.
Vessel does not have a current one line diagram and over
the years has had much work done without verifying gauge
of wiring installed or removing unused or extra wiring.
Operator shall remove excess wiring and work to identify
the items listed
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 May 2023
Resolved 23 May 2024
Resolution: Deficiency has been reissued in a new CG835V Due in 31JULY2024 under activity 7915567.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 2 October 2022
Resolved
Vessel reporting vibrations in the shaft and damaged bearings.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2023
Resolution: Vesse received new shaft, propeller, stuffing box, cutlass bearings, and repaired the shaft log. All were replaced in kind. Successful sea trial conducted after full DE and ISE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 August 2022
Resolved
A vessel must have a reliable means for shutting down a propulsion engine at the main pilothouse control station. The engine stop button at the operating station was not capable of stopping the engine due to a worn spring within the governor.
Action required: 705 - Other - as specified
Due 15 August 2022
Resolved 16 August 2022
Resolution: Vessel adjusted the springs and terminals for the governor.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 29 July 2022
Resolved
At each inspection, the bilges and other spaces may be examined to see there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping system, or block escapes. Escessive oil was observed in the bilge and must be removed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2022
Resolution: Oily water in bilge was pumped out.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 July 2022
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Main engine was found leaking cooling water, further inspection is necessary to identify cause. Repair and conduct sea trial to the satisfaction of the attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2022
Resolution: Vessel resolved propulsion issues to the satisfaction of the OCMI.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 April 2022
Resolved
The cognizant OCMI may require a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. While testing the fire pump, the fire hose began leaking water between the coupling and outer jacket. Replace fire hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 April 2022
Resolution: Hose replaced and tested to satisfaction of OCMI.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 6 April 2022
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure all crew members are familiar with their duties during emergencies. No drill has been logged since May 21, 2021. Sufficient drills and training for emergencies shall be logged and available for review by the Coast Guard.
Action required: 10 - Deficiency Rectified
Resolved 6 April 2022
Resolution: Discussed drill requirements with Captain.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 May 2021
Resolved
Vessel must be equipped with an adult size life jacket for each person authorized. Vessel must also be equipped with child size life jackets equal to at least 10% of the maximum number of passengers permitted. All Life jackets found to be worn. Replace all required life jackets (28) adult and (03)child
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2021
Resolved 14 June 2021
Resolution: New life jackets received and installed on vessel
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 May 2021
Resolved
The fire pump outlet must be fitted with a pressure gauge. Fire pump outlet gauge was found to be cracked and inoperable. Requires replacement.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2021
Resolved 4 June 2021
Resolution: Outlet gauge replaced. Video attached in misle documents
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 May 2021
Resolved
All cable and wire must be not be installed with sharp bends or supported with plastic tie wraps. repair/replace wiring located in aft steering compartment installed with sharp bends and supported by plastic tie wraps.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2021
Resolved 10 June 2021
Resolution: Wires reconfigured without sharp bends and supported with a new bracket. pic included misle.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 May 2021
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must
be repaired or replaced. 05 life jackets determined not
to be in serviceable condition were replaced on the
spot.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 21 May 2021
Resolved 21 May 2021
Resolution: 05 Life jackets replaced with new life jackets during inspection.
Construction/Loadline › Hull › Bracket
Issued 14 March 2017
Resolved
Replace the wasted exhaust bracket in the engine room.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 16 March 2017
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 March 2017
Resolved
Address minor wood rot in various areas of engine room.
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 16 March 2017
Resolution: Sanded areas of angel hair rot back to good wood. No major rot discovered.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 14 March 2017
Resolved
Add securing bolts in two support columns.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 16 March 2017
Construction/Loadline › Penetrations › Valve Flange
Issued 14 March 2017
Resolved
Replace 2" through hull ball valve for the engine cooling water supply as the current one is hard to operate.
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 16 March 2017
Documentation › Markings/Placards › Warning Signs
Issued 14 March 2017
Resolved
Replace the lettering for the fire hose valve as letters are falling off the bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 16 March 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 March 2017
Resolved
Relocate the terminal block near the Fireboy system that is currently low in the bilge to a higher, drier, location.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 16 March 2017
Resolution: Moved the terminal block to a higher location.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 March 2017
Resolved
Replace the highly corroded electrical component located near the batteries.
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 26 April 2017
Resolution: The piece was found to not be needed and was removed from the system.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 14 March 2017
Resolved
Determine if the grounding strip aft of the engine is necesary, if it is, repair or replace it.
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 16 March 2017
Resolution: The grounding strip was determined to be not needed and removed.
Engineering › Engine Controls (Electric/Electronic) › Actuator
Issued 9 May 2016
Resolved
Prove proper operation of pre-engineered fire extinguishing system emergency overide.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2016
Resolved 10 May 2016
Resolution: Successfully tested the MDE emergency overide, after correcting a ground wire that was disconnected.
Engineering › Freshwater Generation System › Valve, Dump
Issued 9 May 2016
Resolved
Replace valve opening/closing lever on raw water intake.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 10 May 2016
Resolution: Lever was replaced with a new one.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 9 May 2016
Resolved
replace oil filter with suitable metal marine type strainer and filter
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 August 2016
Resolved 10 August 2016
Resolution: A new marine approved type fuel oil strainer and filter with a flame arrestor's cup was installed.