SPARTAN II

SPARTAN II is a 1980 tank barge. The Coast Guard has recorded 78 inspections since 1985, most recently in March 2026, along with 63 deficiencies and 4 casualty investigations between 2011 and 2017.

Records from 1985 to 2026. Most recent: inspection, 20 March 2026.

Built
1980
Last inspected
20 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 20 March 2026
…with no type recorded23
Operational controls None recorded without a removal date
Years with a record 34 calendar years (1985–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-52092

Documentation record

Registered dimensions (L × B × D)407.1 ft × 60.1 ft × 20.0 ft
Registered tonnagegross 3,126 / net 3,126
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBAY SHIPBUILDING CORP. · STURGEON BAY, WI, UNITED STATES · built 1980
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLUDINGTON, MI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 9 September 2025 · expires 30 September 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3126 - Regulatory (Subpart C or D), Gross Ton
3126 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SPARTAN Towing Vessel · MISLE 99789 · 10 September 2019 · activity 6826254SPARTAN Towing Vessel · MISLE 99789 · 15 October 2011 · activity 4169698SPARTAN Towing Vessel · MISLE 99789 · 6 July 2011 · activity 4071848SPARTAN Towing Vessel · MISLE 99789 · 31 October 2000 · activity 2085SPARTAN Towing Vessel · MISLE 99789 · 17 July 1999 · activity 16866

Inspection history · 78

20 March 2026 Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 8329279
20 October 2020 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7081063
19 September 2019 Type not recorded
No type recorded · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6837309
10 September 2019 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6826254
21 April 2017 Type not recorded
No type recorded · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6129557
28 May 2015 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5142070
11 June 2014 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4886297
1 June 2013 Damage Survey
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4609702
23 June 2012 Type not recorded
No type recorded · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 4353536
15 October 2011 Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4169698
6 July 2011 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4071848
27 December 2010 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3918950
22 November 2010 Cargo Tank Internal · Administrative Inspection · Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3896816
16 February 2010 Load Line/Change of Employment
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3679283
7 January 2009 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3389973
4 January 2009 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3388231
13 December 2007 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3114830
27 November 2007 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3105277
5 October 2007 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3073446
24 August 2006 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 2762740
7 April 2006 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2619173
9 November 2005 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2531820
31 August 2005 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2456851
17 June 2005 Administrative Inspection
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2393647
2 June 2005 MTSA Verification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2377270
21 October 2004 Administrative Inspection
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2225636
19 October 2004 Damage Survey
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2223612
27 September 2004 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2206531
17 August 2004 Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2168462
1 October 2003 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1917229
18 April 2003 Examination of Repairs
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1780375
22 November 2002 Administrative Inspection
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1709542
16 September 2002 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1675182
20 August 2001 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1376706
31 October 2000 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 2085
16 October 1999 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1440208
30 September 1999 Hull Examination · COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1468093
12 September 1999 Type not recorded
No type recorded · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 87958
17 July 1999 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 16866
24 March 1999 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1113999
30 October 1998 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 804844
17 September 1998 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1364854
23 January 1998 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 780254
18 November 1997 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 773217
3 October 1997 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1445271
18 December 1996 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 671472
1 October 1996 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 214383
1 October 1996 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1377876
11 October 1995 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1431568
22 October 1994 Re-Inspection · Deficiency Check · Examination of Repairs · Hull Examination
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1436918
4 November 1993 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 671473
3 November 1993 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 488593
2 November 1993 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1464488
19 November 1992 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1139174
9 July 1992 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1397817
20 December 1991 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1259512
15 November 1991 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1249291
15 November 1991 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1249777
22 September 1991 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 469939
19 April 1991 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1221025
10 January 1991 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 906400
12 August 1990 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 447958
19 July 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 905413
16 June 1990 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 464312
9 April 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1221529
13 March 1990 Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 904006
18 December 1989 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 917635
16 February 1989 Permit to Proceed
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1346225
7 May 1988 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 499784
16 February 1988 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1329470
6 August 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 509615
30 June 1987 Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1026897
16 March 1987 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 515418
15 October 1986 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1319082
19 September 1986 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 444879
30 January 1986 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1305544
22 January 1986 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 995495
30 December 1985 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1303273

Deficiency record · 63

Stability › Incline Test › General
Issued 27 December 2010 Resolved
Vessel required by MSC, MSU Chicago (and agreement w/ABS) to conduct the deadweight stability test and submit calculations to MSC for review by 01 June 2011. See Act# 3918950
Action required: 705 - Other - as specified
Due 1 June 2011
Resolved 18 April 2011
Resolution: Deadweight survey conducted. Loading manual and stability letter issued and uploaded into MISLE
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 5 October 2007 Resolved
Properly service or replace CO2 extinguishers (3) on barge with currently serviced portables.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2007
Resolution: Retrieved extras from towboat
Communications › Visual Communication › Warning Sign (gangway)
Issued 5 October 2007 Resolved
Renew warning signs painted on hull IAW 35.30-1.
Due 17 December 2007
Resolved 13 December 2007
Electrical › Electric Supply System (service) › Cable
Issued 5 October 2007 Resolved
Renew insulation at terminals on compressor motor starter.
Due 17 December 2007
Resolved 13 December 2007
Construction/Loadline › Structures › Trunk
Issued 5 October 2007 Resolved
Install wingnuts where missing on forward vent, generator space exhaust
Due 17 December 2007
Resolved 13 December 2007
Construction/Loadline › Structures › Scuttle
Issued 5 October 2007 Resolved
Reinstall watertight cover on gooseneck vent, ballast tank #4 stbd.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2007
Resolution: Cover found and reinstalled
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 5 October 2007 Resolved
Police forward machinery space, to include removal of excess waste, securing extra batteries, wiping excess oil from all diesel engines.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 October 2007 Resolved
Install hazard guard on bowthruster horizontal drive shaft, fwd machinery space.
Due 17 December 2007
Resolved 13 December 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 October 2007 Resolved
Reinstall cover on forward end of generator.
Due 17 December 2007
Resolved 13 December 2007
Electrical › Electrical Distribution System (service) › Panelboard
Issued 5 October 2007 Resolved
Install blank on circuit #23, forward machinery space distribution panel
Due 17 December 2007
Resolved 13 December 2007
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 5 October 2007 Resolved
Install protective cover over wiring junction box, forward side of bow thruster diesel engine.
Due 17 December 2007
Resolved 13 December 2007
Electrical › Electric Supply System (service) › Cable
Issued 5 October 2007 Resolved
Replace wire nuts with mechanical or crimp fittings in circuit for bowthruster starter.
Due 17 December 2007
Resolved 13 December 2007
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 5 October 2007 Resolved
Renew lettering on emergency shutdown pull cord station.
Due 17 December 2007
Resolved 13 December 2007
Communications › Visual Communication › Red Warning Signal
Issued 5 October 2007 Resolved
Replace lens on loading light.
Due 17 December 2007
Resolved 13 December 2007
Construction/Loadline › Markings › Load Line Mark
Issued 5 October 2007 Resolved
Renew loadline on starboard side midbody.
Due 17 December 2007
Resolved 13 December 2007
Engineering › Compressed Air System (control) › Compressor
Issued 5 October 2007 Resolved
Prove proper operation of tachometer, compressor diesel engine.
Due 17 December 2007
Resolved 14 December 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 September 2005 Resolved
Provide operation of aft Navigation light in accordance with 33 CFR subchapter D and Navigation Rules prior to getting underway.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 September 2005
Resolution: Fixed while in attendance.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 September 2005 Resolved
Provide operation of two navigation lights amidships in accordance with navigation rules or remove.
Action required: 705 - Other - as specified
Due 16 December 2005
Resolved 26 September 2016
Resolution: Witnessed proper operation of navigation lights, all sat.
Deck/Cargo › Holds/Tanks › Hatch
Issued 9 September 2005 Resolved
Replace missing dog on #3 void hatch port side in 46 CFR 42.15.
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 21 November 2005
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 9 September 2005 Resolved
Replace flame screen on #4 void port side in accordance with 46 CFR 32.20-10.
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 21 November 2005
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 9 September 2005 Resolved
Replace all gaskets on stbd side and #5 void on port side.
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 21 November 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 September 2005 Resolved
Remove three batteries in bow thruster room not being used in accordance with 46 CFR 111.15.
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 21 November 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 September 2005 Resolved
Cover battery bank on port side aft in bow thruster room in accordance with 46 CFR 111.15.
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 21 November 2005
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 9 September 2005 Resolved
Provide non conductive mat under distribution panel in accordance with 46 CFR111.12.
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 21 November 2005
Electrical › Electrical Distribution System (service) › Switchboard
Issued 9 September 2005 Resolved
Replace voltage and amperage gauge on switchboard in accordance with 46 CFR 111.30 in bow thruster room.
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 21 November 2005
Engineering › Diesel Engine (auxiliary) › Governor
Issued 9 September 2005 Resolved
Replace RPM gauge on diesel engine prime mover for air compressor engine in bow thruster room.
Action required: 705 - Other - as specified
Due 16 December 2005
Resolved 7 April 2006
Engineering › Diesel Engine (auxiliary) › Piping (air intake)
Issued 9 September 2005 Resolved
Supply double clamps on diesel engine for air compressor engine in bow thruster room 46 CFR 111.25.
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 21 November 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 9 September 2005 Resolved
Provide new labels for cargo hoses in accordance with 33 CFR 154.500.
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 21 November 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 9 September 2005 Resolved
Remove or properly test oil service hose in accordance with 33 CFR 154.500.
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 21 November 2005
Resolution: Removed oil service hose from barge, all sat.
Deck/Cargo › Ballast › Pumps
Issued 9 September 2005 Resolved
Provide RPM gauge on port side ballast pump in accordance with 46 CFR 111.12.
Action required: 705 - Other - as specified
Due 16 December 2005
Resolved 7 April 2006
Deck/Cargo › Holds/Tanks › Cargo Tank Drainage
Issued 17 August 2004 Resolved
Repair and prove proper operation of all cargo tank stripping piping in order to carry cargos listed on the Cargo Authority Attachment.
Action required: 705 - Other - as specified
Due 21 October 2004
Resolved 21 October 2004
Resolution: Ammended the COI to carriage of calcium chloride limited to densties less than or equal to 14.3 pounds per gallon and urea ammonium nitrate solution containing less than two percent ammonia.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 17 August 2004 Resolved
Provide plans to the cognizant OCMI for approval and installation of restricted cargo tank gauging devices on all cargo tanks per 46 CFR 151.15-10(b).
Action required: 705 - Other - as specified
Due 21 October 2004
Resolved 21 October 2004
Resolution: Ammended the COI to carriage of calcium chloride limited to densties less than or equal to 14.3 pounds per gallon and urea ammonium nitrate solution containing less than two percent ammonia.
Deck/Cargo › Cargo Heating › General
Issued 17 August 2004 Resolved
Provide a proposal to the cognizant OCMI that details means to satisfactorily disconnect the cargo tank heating coils per the requirements detailed in 46 CFR 151.50-81(a).
Action required: 705 - Other - as specified
Due 21 October 2004
Resolved 21 October 2004
Resolution: Ammended the COI to carriage of calcium chloride limited to densties less than or equal to 14.3 pounds per gallon and urea ammonium nitrate solution containing less than two percent ammonia.
Construction/Loadline › Hull › Bottom Plating
Issued 17 August 2004 Resolved
Make permanent repairs to bottom plate, #5 port ballast tank, frame 42 1/3, approx. 18" inboard of side shell. Remove temp box patch and insert at next drydock.
Action required: 705 - Other - as specified
Due 30 September 2014
Resolved 29 November 2010
Resolution: Area of damged bottom plate has been replaced.
Engineering › Diesel Engine (auxiliary)
Issued 1 October 2003 Resolved
Correct hydraulic leak on air compressor engine (piping misalignment)
Due 1 November 2003
Resolved 20 October 2003
Resolution: new gaskets installed no leaks found
Construction/Loadline › Structures
Issued 1 October 2003 Resolved
Replace broken dogs on void hatches, port side
Due 1 November 2003
Resolved 20 October 2003
Resolution: all hatches sat
Deck/Cargo › Cargo Stowage
Issued 1 October 2003 Resolved
Renew gauge hatches, clean seats of corrosion to achieve goo seal (small hatches set in cargo hatches). Vessel prohibited from carrying oils or hazardous materials pending completion. Note, Vessel normally carries calcium chloride, an non-hazardous material
Condition: Improper/Lack of Maintenance
Due 1 December 2003
Resolved 20 October 2003
Resolution: renewed all hatches and all gaskets.
Accommodation/Occupational Safety
Issued 1 October 2003 Resolved
Remove or repair all damaged & loose sheet metal over the steam piping lagging on deck (no longer used). Loose covering constitutes a personnel hazard in the form of considerable opportunity for someone to be cut.
Due 1 November 2003
Resolved 20 October 2003
Resolution: all lagging removed.
Deck/Cargo
Issued 30 September 1999 Resolved
Vessel is restricted from carrying Caustic soda solution (CSS) & Caustic potash solution (CPS) until proper cargo tank P/V valves are installed as per 46 CFR Table 151.05 & 46 CFR 151.56-1(j).
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Deck/Cargo
Issued 17 September 1998 Resolved
Vessel is precluded from carrying Benzene (BNZ) or Cyclopentadiene, Styrene, Benzene (CSB) mixture pending installation of closed gauging
Condition: Unknown
Due 17 September 1998
Resolved 17 September 1998
Documentation
Issued 17 September 1998 Resolved
Vessel is precluded from carrying cargoes requiring a Vessel Response Plan (oils & oil-like substances) pending production and approval of same.
Condition: Unknown
Due 17 September 1998
Resolved 17 September 1998
Electrical
Issued 17 September 1998 Resolved
Blank open in 120v power panel
Condition: Unknown
Due 17 September 1998
Resolved 17 September 1998
Electrical
Issued 17 September 1998 Resolved
Mount cabling over generator set with metallic wire ties
Condition: Unknown
Due 17 September 1998
Resolved 17 September 1998
Electrical
Issued 17 September 1998 Resolved
Replace two generator fuel hoses with proper type (existing are automotive hoses)
Condition: Unknown
Due 17 September 1998
Resolved 17 September 1998
Construction/Loadline
Issued 3 October 1997 Resolved
Prior to loading any flammble or combustible cargo, make permanet repairs to inspection ports on all tank hatch covers to the satisfaction of the cognizant OCMI and no later than 06 November 1997.
Condition: Unknown
Due 6 November 1997
Resolved 19 November 1997
Deck/Cargo
Issued 1 October 1996 Resolved
Refit port aft cargo containment drainage line to conform to the vessel's oil transfer procedures, or amend oil transfer procedures to accurately reflect all current containment drainage installations.
Condition: Unknown
Due 31 October 1996
Resolved 24 October 1996
Lifesaving
Issued 1 October 1996 Resolved
Restencil or replace the warning signs required by 46 CFR 51-45-2(e) on both the port and starboard sides of the raised cargo tank top.
Condition: Unknown
Due 31 October 1996
Resolved 24 October 1996
Deck/Cargo
Issued 1 October 1996 Resolved
Replace caps on port and stbd dockside cargo stripping lines.
Condition: Unknown
Due 31 October 1996
Resolved 25 October 1996
Deck/Cargo
Issued 1 October 1996 Resolved
Prior to loading cargo, provide evidence of satisfactory completion of hydrostatic tests of all cargo hoses and piping.
Condition: Unknown
Due 31 October 1996
Resolved 24 October 1996
Documentation
Issued 22 October 1994 Resolved
Amend the oil transfer procedures on board the tank barge to include information applicable to the transfer of fuel oil or slops to or from the vessel as required by 33CFR155.750 prior to the compliance date.
Condition: Unknown
Due 22 October 1994
Resolved 22 October 1994
Engineering
Issued 2 November 1993 Resolved
PROVE PROPER OPERATION OF 3EA AIR RECEIVER RELIEF VALVES.
Condition: Unknown
Due 26 November 1993
Resolved 1 December 1993
Engineering
Issued 15 November 1991 Resolved
OPEN AIR RECEIVERS FOR INTERNAL EXAMINATION: 2 EA IN BOW THRUSTER/AIR COMPRESSOR ROOM, 1 EA ON PORT AFT MAIN DECK; AND LIFT THEIR RESPECTIVE RELIEF VALVES.
Condition: Unknown
Due 15 December 1991
Resolved 1 April 1992
Engineering
Issued 15 November 1991 Resolved
OPEN AND REMOVE ALL BOILER MOUNTINGS FOR INSPECTION BY A USCG INSPECTOR.
Condition: Unknown
Due 15 November 1991
Resolved 15 November 1991
Engineering
Issued 15 November 1991 Resolved
PROVE PROPER OPERATION OF VAPOR STEAM GENERATOR PRIOR TO USE FOR HEATING CARGO.
Condition: Unknown
Due 15 December 1991
Resolved 1 April 1992
Engineering
Issued 15 November 1991 Resolved
CONDUCT A HYDROSTATIC PRESSURE TEST @ 1 1/4 MAWP IN THE PRESENCE OF A USCG INSPECTOR.
Condition: Unknown
Due 15 November 1991
Resolved 15 November 1991
Engineering
Issued 15 November 1991 Resolved
OPEN THE FIRESIDES AND WATERSIDES FOR INSPECTION BY A USCG INSPECTOR.
Condition: Unknown
Due 15 November 1991
Resolved 15 November 1991
Unknown
Issued 18 December 1989 Resolved
THE FOLLOWING CARGOES ARE NOT TO BE CARRIED UNTIL AUTHORIZED BY COMMANDANT (G-MSC-3):CARBON TETRACHLORIDE, ETHYL BENZENE, ETHYLENE GLYCOL, AND TOLUENE.
Condition: Unknown
Due 18 December 1989
Resolved 18 December 1989
Deck/Cargo
Issued 30 December 1985 Resolved
STENCIL ALL EMERGENCY CARGO PUMP SHUTDOWNS. TO BE COMPLETED NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 30 December 1985
Resolved 30 December 1985
Navigation
Issued 30 December 1985 Resolved
REPLACE RELIEF VALVE ON MAIN AIR TANK AND TEST IN PRESENCE OF MARINE INSPECTOR. TO BE COMPLETED NO LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 30 December 1985
Resolved 30 December 1985
Navigation
Issued 30 December 1985 Resolved
REPAIR AND PROVE OPERATION OF THE BARGE NAVIGATION LIGHTS. TO BE COMPLETED NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 30 December 1985
Resolved 30 December 1985
Electrical
Issued 30 December 1985 Resolved
PROVIDE AND INSTALL MAT IN FRONT OF SWITCH BOARD. TO BE COMPLETED NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 30 December 1985
Resolved 30 December 1985
Deck/Cargo
Issued 30 December 1985 Resolved
REPAIR GASKET ON #1 PORT HATCH AND ULLAGE GASKET ON #3 PORT. TO BE COMPLETED NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 30 December 1985
Resolved 30 December 1985
Deck/Cargo
Issued 30 December 1985 Resolved
INSTALL ULLAGE SCREENS IN ALL OPENINGS. TO BE COMPLETED NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 30 December 1985
Resolved 30 December 1985

Casualty record · 4

6 July 2011Routine · role: Transiting Vicinity of Primary Subject · activity 4071848
15 October 2011Routine · role: Involved in a Marine Casualty · activity 4169698
23 June 2012Routine · role: Alleged Pollution Source · activity 4353536
21 April 2017Routine · role: Involved in a Marine Casualty · activity 6129557
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record